0% found this document useful (0 votes)
177 views9 pages

Cyclone Design and Efficiency Guide

The document discusses the design of cyclone separators. Cyclones can operate at gravity forces from 2500 to 5 times normal, depending on their size and resistance. Their efficiency depends on particle size, with smaller particles like 5 micrometers being less efficient than larger particles like 200 micrometers. Cyclones can remove both solids and liquids from gases, operating at temperatures up to 1000°C and pressures up to 50,700 kPa. The tangential velocity in the cylindrical portion of cyclones ranges from the radius of the gas outlet pipe to the radius of the collector.

Uploaded by

frilymarina
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
177 views9 pages

Cyclone Design and Efficiency Guide

The document discusses the design of cyclone separators. Cyclones can operate at gravity forces from 2500 to 5 times normal, depending on their size and resistance. Their efficiency depends on particle size, with smaller particles like 5 micrometers being less efficient than larger particles like 200 micrometers. Cyclones can remove both solids and liquids from gases, operating at temperatures up to 1000°C and pressures up to 50,700 kPa. The tangential velocity in the cylindrical portion of cyclones ranges from the radius of the gas outlet pipe to the radius of the collector.

Uploaded by

frilymarina
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd

Cara desain Cyclone

Kondisi operasi umumnya dari 5 times gravity in very large diameter,low – resistence cyclone, - 2500
times gravity in very small, high resistance unit. The immediate entrance to a cyclone is usually
rectangular.

Efisiensi untuk ukuran partikel lebih rendah yaitu 5μm, sedangkan yang lebih besar menggunakan
ukuran partikel 200 μm.

In certain instances efficiensu as high as 98% have been attained on dust having ultimate particle size
of 0.1 – 2.0 μm predominant effect of flocculation. Cyclones are used to remove both solids and
liquids from gases and

have been operated at temperatures as high as 1000°C and pressures

as high as 50,700 kPa (500 atm).


Menemukan 0.25 for tangential velocity measured in the cylindrical portion of the

cyclone at positions ranging from the radius of the gas-outlet pipe to

the radius of the collector.