Maintenance costs
Image: CSD 125 T SFC
Energy costs
Energy cost savings
through system optimisation Potential energy cost savings
2 3
www.kaeser.com
CSD(X) series
KAESER quality and efficiency
for every need
Name:
Level:
Valid until:
4 5
www.kaeser.com
CSD(X) T series
Premium compressed air quality
with an integrated refrigeration
dryer
Switching KAESER refrigeration dryer energy saving control
performance Conventional refrigeration dryers with continuous control
KAESER energy saving
10 12 18 20 Time (min)
3.5 kg
3.0 kg
2.5 kg
2.0 kg
1.5 kg
1.0 kg
0.5 kg
0 kg
CSD 85 T CSD 105 T CSD 125 T CSD 125 T
(8 bar) (11/15 bar)
New Until now
6 7
www.kaeser.com
Specific power
(kW/m³/min) Conventional speed control
8 9
www.kaeser.com
CSD(X) series
25 %
100 %
ambient heat
Use heat, reduce costs
total electrical power
consumption
25 %
compressed
air energy
potential
Approx. 5 %
heat dissipation
from the Approx. 2 %
drive motor heat dissipated
by the compressor
into the ambient air
+70 °C 96%
Approx. 96 %
recoverable heat energy
hot recoverable
Process, heating and service water Heat recovery a win
Hot water – up to 70 °C – can be produced from reus- Amazingly, 100 percent of the electrical drive energy
able compressor heat via the heat exchanger system. input to a compressor is converted into heat. From
Please contact KAESER regarding higher tempera- that, up to 96 percent is available for heat recovery
ture requirements. purposes. Use this potential to your advantage!
10 11
www.kaeser.com
12 13
www.kaeser.com
Equipment Design
Complete unit
Ready-to-run, fully automatic, super- Standard version
silenced, vibration damped, all panels
powder coated. Suitable for use in Inlet filter
ambient temperatures up to +45°C. Inlet valve
Airend
Sound insulation Drive motor
Panels lined with laminated mineral Fluid separator tank
wool.
Compressed air aftercooler
KAESER centrifugal separator
Vibration dampening
ECO-DRAIN condensate drain
Double insulated anti-vibration Fluid cooler
mountings using rubber bonded metal
Electronic Thermal Management
elements.
Fluid filter
Radial fan
Airend
Genuine KAESER rotary screw, single
stage airend with energy-saving
SIGMA PROFILE rotors and cooling
fluid injection for optimised rotor
cooling. 1:1 direct drive.
Drive
Rotary screw airend with energy-saving SIGMA PROFILE rotors
Direct, high-flex coupling,
without gearing.
14 15
www.kaeser.com
CSD 85 10 6.89 12 45 1760 x 1110 x 1900 G2 70 1250 CSD 85 T 10 6.89 12 45 0.8 2160 x 1110 x 1900 G2 70 1410
13 5.50 15 13 5.50 15
CSD 105 10 8.18 12 55 1760 x 1110 x 1900 G2 71 1290 CSD 105 T 10 8.18 12 55 0.8 2160 x 1110 x 1900 G2 71 1450
13 6.74 15 13 6.74 15
CSD 125 10 10.04 12 75 1760 x 1110 x 1900 G2 72 1320 CSD 125 T 10 10.04 12 75 2160 x 1110 x 1900 G2 72 1510
0.8
13 8.06 15 13 8.06 15
1900 1110
SFC - Version with variable speed drive T SFC - Version with variable speed drive and integrated refrigeration dryer
Model
Modell Working
Betriebs- Flow rate* overall
Liefermenge * Max.
max. Rated motor
Motornenn- Dimensions
Abmessungen Compressed Sound
Anschluss Schalldruck- Mass
Masse Model
Modell Working
Betriebs- Flow rate* overall
Liefermenge * Max.
max. Rated motor
Motornenn- Dryer
Kältetrockner- Dimensions
Abmessungen Compressed Sound
Anschluss Schalldruck- Mass
Masse
pressure
überdruck machine at bei
Gesamtanlage working
Überdruck power
leistung W
B x TD xx HH air
Druckluft pressure
pegel ** pressure
über- machine at bei
Gesamtanlage working
Überdruck power
leistung power
leistungs- W
B x TD xx HH air
Druckluft pressure
pegel **
working pressure
Betriebsüberdruck pressure connection level ** druck working pressure
Betriebsüberdruck pressure consumption
aufnahmen connection level **
CSD 85 SFC 10 1.48 - 6.91 12 45 1760 x 1110 x 1900 G2 72 1260 CSD 85 T SFC 10 1.48 - 6.91 12 45 0.8 2160 x 1100 x 1900 G2 71 1420
CSD 105 SFC 10 1.90 - 8.35 12 55 1760 x 1110 x 1900 G2 73 1380 CSD 105 T SFC 10 1.90 - 8.35 12 55 0.8 2160 x 1110 x 1900 G2 72 1540
CSD 125 SFC 10 2.05 - 10.53 12 75 1760 x 1110 x 1900 G2 74 1400 CSD 125 T SFC 10 2.05 - 10.53 12 75 2160 x 1110 x 1900 G2 73 1590
0.8
13 1.79 - 8.75 15 13 1.79 - 8.75 15
1900 1110
* Flow rate in accordance with ISO 1217: 2009, Annex C: Absolute intake pressure 1 bar (a), cooling and air intake temperature 20 °C
** Sound pressure level as per ISO 2151 and basic standard ISO 9614-2, operation at maximum working pressure and maximum speed; tolerance: ± 3 dB (A)
16 17
www.kaeser.com
CSDX 140 10 11.83 12 75 2110 x 1290 x 1950 G2 71 1830 CSDX 140 T 10 11.83 12 75 1.2 2510 x 1290 x 1950 G2 71 2045
13 9.86 15 13 9.86 15
CSDX 165 10 13.53 12 90 2110 x 1290 x 1950 G2 72 1925 CSDX 165 T 10 13.53 12 90 1.2 2510 x 1290 x 1950 G2 72 2140
13 11.49 15 13 11.49 15
1950 1950
SFC - Version with variable speed drive T SFC - Version with variable speed drive and integrated refrigeration dryer
Model
Modell Working
Betriebs- Flow rate* overall
Liefermenge * Max.
max. Rated motor
Motornenn- Dimensions
Abmessungen Compressed Sound
Anschluss Schalldruck- Mass
Masse Model
Modell Working
Betriebs- Flow rate* overall
Liefermenge * Max.
max. Rated motor
Motornenn- Dryer
Kältetrockner- Dimensions
Abmessungen Compressed Sound
Anschluss Schalldruck- Mass
Masse
pressure
überdruck machine at bei
Gesamtanlage working
Überdruck power
leistung W
B x TD xx HH air
Druckluft pressure
pegel ** pressure
über- machine at bei
Gesamtanlage working
Überdruck power
leistung power
leistungs- W
B x TD xx HH air
Druckluft pressure
pegel **
working pressure
Betriebsüberdruck pressure connection level ** druck working pressure
Betriebsüberdruck pressure consumption
aufnahmen connection level **
CSDX 140 SFC 10 2.81 - 11.33 12 75 2110 x 1290 x 1950 G2 72 1835 CSDX 140 T SFC 10 2.81 - 11.33 12 75 1.2 2510 x 1290 x 1950 G2 72 2050
CSDX 165 SFC 10 3.29 - 13.84 12 90 2110 x 1290 x 1950 G2 73 2025 CSDX 165 T SFC 10 3.29 - 13.84 12 90 1.2 2510 x 1290 x 1950 G2 73 2240
1950 1950
* Flow rate in accordance with ISO 1217: 2009, Annex C: Absolute intake pressure 1 bar (a), cooling and air intake temperature 20 °C
** Sound pressure level as per ISO 2151 and basic standard ISO 9614-2, operation at maximum working pressure and maximum speed; tolerance: ± 3 dB (A)
18 19
www.kaeser.com
Choose the required grade of treatment according to your field of application: Explanation
Air treatment using a refrigeration dryer (pressure dew point +3°C) ACT Activated carbon adsorber
Application examples: Selection of treatment classes to ISO 8573-1 (2010) AQUAMAT AQUAMAT
Installation for heavily
DD Desiccant dryer
Solids Water Oil
fluctuating air demand
DHS Air-main charging system
DHS FF
Pure air and clean-room AR Air receiver
technology, dairies, breweries 1 4 1
ED ECO DRAIN
DHS FE FD ACT FF FB / FC Pre-filter
Foodstuff production FD Particulate filter
2 4 1 Optional
AR filtration RD* ZK FE / FF Microfilter
DHS FFG Activated carbon and microfilter combination
Very clean conveying air,
chemical plants 3 4 1 FG Activated carbon filter
RD Refrigeration dryer
DHS FF FFG THNF Bag filter
Pharmaceutical industry
1 4 1 AR ZK Centrifugal separator