You are on page 1of 12

BL_MV1S_01:BL.AFD.01.

qxd 6/24/2009 12:24 PM Page 1


BL_MV1S_01:BL.AFD.01.qxd 6/24/2009 12:24 PM Page 2

Yaskawa products are being used in an expanding range of environments and applications. In 1996, Yaskawa introduced Japan’s first
commercially produced PWM, medium-voltage AC inverter with multi-output connected in series. Building on this high-level technique,
Yaskawa is manufacturing an easy to operate, highly reliable medium-voltage adjustable frequency drive.

Yaskawa is the world leader in quality and reliability. Over 1000 medium-voltage installations with zero downtime. This commitment to
quality is directly related to customer satisfaction.

With an ISO 9000 system, a Supplier Rating Program, and rigorous testing, Yaskawa ensures that quality and reliability are designed and
built in. Field data confirms that calculated MTBF targets are exceeded in actual production units. Yaskawa is the only manufacturer in
our field to receive the Deming Prize for quality.

Earned in 1984 and maintained ever since

New Features New Features


- Instantaneous speed search during momentary Easy to manage power cell structure, and
power loss improved monitoring for reduced downtime
- Input current waveforms virtually without harmonics
Each individual power cell can be removed for
- Sinusoidal output voltage waveforms
maintenance, and the enhanced trace function also
- Low torque ripple
simplifies maintenance and monitoring.
- Highly efficient V/f patterns
- Constant or variable torque operation for the
flexibility to handle all industrial applications
- Automatic switching between AC inverter and
commercial power source
- Energy $avings
- Multiple motor operation
- Long motor lead length
- Existing motor friendly

2
BL_MV1S_01:BL.AFD.01.qxd 6/24/2009 12:25 PM Page 3

Sophisticated flux vector control improves the starting torque characteristics


and responsiveness to fluctuations in the load without using a pulse Motor Torque
generator. Maintains stable operation even with load fluctuations.

Motor Speed

Motor Current

Easy Monitoring of Operation Status


The enhanced trace function and
LAN compatibility enable you
to easily monitor the operation
status for preventive maintenance
and service.

Controlled and Secure Operation at Momentary Power Loss


The MV1S continues to operate during a Instantaneous Searching Function KEB Function*2
Input Voltage Input Voltage
momentary power loss of several cycles*1.
The MV1S re-accelerates to the reference Motor Speed Motor Speed
speed almost at the same time as the power
is restored to ensure smooth starts. Speed Reference Speed Reference

*1 : Load dependent
Motor Current Motor Current

250 ms
*2 : Function
KEB (Kinetic Energy Braking) Function:
to continue operation without
base-blocking during momentary
power loss.

Stable Deceleration Operation


A function to prevent excessive deceleration Function to Prevent Excessive Deceleration
has been added to avoid nuisance Maintains the speed reference
overvoltage trips during deceleration. to avoid overvoltage
Output
If the DC bus voltage rises above a preset Frequency
Restarts deceleration after the
limit during deceleration, the inverter stops DC bus voltage drops to normal.
decelerating. This prevents a DC bus
overvoltage trip from occurring, and enables
continuous operation.
Time
Deceleration Time (Set Value)

3
BL_MV1S_01:BL.AFD.01.qxd 6/24/2009 12:25 PM Page 4

The Most Efficient Use of Energy Easy Application to Existing Motors


Since this Inverter is a direct medium-voltage inverter By employing multiple PWM control, a nearly sinusoidal
that does not need an output transformer, it can main- waveform is applied to the motor without a filter.
tain a power conversion efficiency of approx. 97% so as This provides the following benefits:
not to waste energy. Free from oscillation surge voltage affecting the motor
Power factor is always kept at approx. 0.95. (reflected wave phenomenon)
Since the power factor does not change even if the Low torque ripple
motor speed changes, no power factor correction Audible noise as low as commercial power supply
capacitors are needed. operation
The existing motors and cabling can be used
Power Conversion Efficiency Ratio without modification.
100
Output Waveform
Power Conversion Efficiency
90 (approx. 97%)
Efficiency and Power Factor (%)

Power Supply Power Factor


(0.95 or more)
Voltage
80

70
Current

60

50 60 70 80 90 100
Speed (%)

Easy Maintenance
Easy to manage power cell structure, and improved monitoring for reduced downtime.
Individual Cell Maintenance (140 A or Less)
Each individual cell can be removed for replacement or maintenance.
This structure shortens replacement time and simplifies maintenance.

Perfect Harmonics Measure


The input waveform is virtually sinusoidal with very
Input Waveform
low harmonics. Therefore, the MV1S passes the
IEEE 519-1992 harmonic guideline specification so Voltage
that harmonic filters or active filters are not required.

MV1S (3.3 kV, 690 kW, 60 Hz) compared to IEEE 519-1992


and measured value of harmonics in input current of MV1S Current
(In case of 3.3 kV, 630 kW, 60 Hz, all-load contract demand 630 kW)

5th 7th 11th 13th 17th 19th 23rd 25th 29th 31st
IEEE519 Guideline
(Isc/II<20, TDD 5%) 4.00 4.00 2.00 2.00 1.50 1.50 0.60 0.60 0.60 0.60
MV1S Drive
Measured Value 1.07 0.53 0.90 0.49 0.78 0.76 0.06 0.26 0.11 0.07
(Unit : %)

4
BL_MV1S_01:BL.AFD.01.qxd 6/24/2009 12:26 PM Page 5

Components
Transformer Section
• Input power terminals, output
power terminals, and input multi-
phase transformer
• Air cooled, dry-type transformer*
utilized
Power Cell Section
• 3, 4, or 6 cells connected in series
per inverter output phase
• Output phases are connected to
output 3, 4.16, or 6kV directly
Control Section
• Control board for multiple PWM
output
• Communication with power cells
via optical cable

* : Transformer in-rush current flows when the


input power supply is turned ON. Transformer Section Power Cell Control
Section Section

Circuit Configuration
The MV1S uses PWM control with multiple outputs connected
in series, using 3, 4, or 6 (single phase) power cells per output 4 Power Cells
per Phase U
phase.
U1

Example of 4.16 kV U2
2940 V
Transformer Cell Phase Voltage
U3 4160 V
Line Voltage
U1 U4
V1
W1 W4 N V4
U2 W3 V3
V2 W2 V2
Controller

W1 V1
Input W2
4.16 kV U3 W V
V3
W3
U4 Configuration of One Power Cell
V4
W4

Q1 Q3

Motor
R
Power L1

Supply S Output
Input L2
T

Q2 Q4

5
BL_MV1S_01:BL.AFD.01.qxd 6/24/2009 12:26 PM Page 6

Rotating Direction Display


FWD : LED lights at forward run.
REV : LED lights at reverse run.
Remote Mode
Lights when selecting input mode from the control
Mode Display circuit terminal.
SEQ : LED lights when selecting run command from
DRIVE : LED lights at Drive Mode.
control circuit terminal.
REF : LED lights when selecting frequency reference
QUICK : LED lights at Quick
from control circuit terminals A1, A2, and A3.
Programming Mode.

ADV : LED lights at Advanced


Programming Mode.

A. TUNE : LED lights at


Autotuning Mode.

Operation Mode Selection Key


The operation mode is
alternated with REMOTE
(control circuit terminal) and
LOCAL (digital operator)
(When run command and
frequency reference are set
at control circuit terminal.)
Menu Key
Changes the display of operation
and programming mode.
Run Command Keys
.............................................................
Run command keys for use Escape Key
by digital operator. Enabled
only in the drive mode. Returns to the status entered
before [DATA/ENTER] key
was pressed.
JOG : Jog run is enabled
while depressing DATA/ENTER Key
this key. Selects mode, group, function
FWD/REV : Selects forward or or parameter name. Displays
reverse run. each parameter set value while
Forward and reverse displaying a parameter name.
run is alternated. By pressing this key again, the
RUN : Red LED lights by set value is written in.
depressing RUN.
STOP : Red LED lights by : Increment Key
depressing STOP. : Decrement Key
Selects mode, group,
function, parameter name or
set value.
Shift/Reset Key
Selects a digit of a set value
to be changed. The selected
digit blinks.
(Resets operation at faults.)

6
BL_MV1S_01:BL.AFD.01.qxd 6/24/2009 12:26 PM Page 7

FSDrive-MV1S
Power R U
S V IM
Supply T Digital Operator W

The MV1S adjustable frequency drive Digital Input Analog Output

incorporates a variety of application features.


Select the correct function from a multitude of Pulse Input
possibilities to optimize the MV1S to your Communication
Option Card
application. Digital Output
Analog Input

Input Option Output Option

Function Application Description of Function


Adjusts motor voltage as function of load and speed for most efficient
Energy Saving Control Most efficient operation
operation (includes automatic temperature compensation).

Starts the MV1S at a selected frequency, reduces output frequency


Speed Search Function Start into spinning motor until synchronized with motor, applies full excitation to bring motor to
operating speed. No speed detector required.

Automatically switches motor from Switching from drive to line is automatic for optimum efficiency
Line Bypass Function
MV1S to AC lines at full speed.

STOP RUN
S1
RUN
Choice of configuration for control Either 2-wire (contact closure) or S2
2-wire or 3-wire Sequence STOP
circuit 3-wire (Start-stop PB) are standard. S5
FWD/REV
SC

Quick Stop without DC injection braking function DC injection braking can be performed from top speed. 5% duty cycle.
Dynamic Braking included Provided 50-70% of full load torque for braking.

Torque Limit Protects machine, eliminates The MV1S will coast (or reduce speed) when it reaches a preset torque limit.
(Droop Function) nuisance trips Useful in fan and pump applications.

Upper/Lower Frequency Defines operating range of the Upper and lower limits of motor speed, reference bias, and gain can
Limit Setting motor be independently set within the drive.

Avoid mechanical resonance in The motor passes through the selected speed but will not operate there.
Jump Frequency Control
the machine This avoids operation at speeds coincident with mechanical resonance.

Low Voltage Signal System protection for undervoltage Closed when tripped by a (adjustable) low voltage. Can be used as a
power loss detection relay for control of other equipment.

At Speed Signal Reference speed interlock Closed when speed matches a preset frequency reference.

Base Block Signal Operation interlock Closed when MV1S output is off.

Frequency Reference Closed when frequency reference suddenly drops to 10% or less of
Reliability improvement
Sudden Change Detection the set value. Useful for loss of reference detection.

Multi-function Can be used as supplemental speed reference or to adjust other


Flexible operation
Analog Input functions while in operation - overtorque detection, for example.

Multi-function Use two of the following: frequency meter, ammeter, voltmeter,


Monitor function enhancement
Analog Output wattmeter or frequency reference monitor.

7
BL_MV1S_01:BL.AFD.01.qxd 6/24/2009 12:27 PM Page 8

Standard Specifications
Model: CIMR-MV1S A 132 200 315 450 630 900 13C 15C 18C 25C
Nominal Capacity (kVA) 200 285 400 570 800 1150 1500 1900 2300 3000
3 kV Maximum Applicable Motor Capacity (kW)*1 132 200 315 450 630 900 1250 1500 1800 2500
Class Output Rated Output Current (A) 35 50 70 100 140 200 260 330 400 520
Rating Rated Output Voltage 3-phase, 3/3.3 kV (sinusoidal wave)
Main Circuit Power Supply 3-phase, 3/3.3 kV ±10%, 50/60 Hz ±5%
Model: CIMR-MV1S B 570 800 11C 15C 23C 29C
Nominal Capacity (kVA) 720 1000 1440 1875 2900 3750
4.16 kV Maximum Applicable Motor Capacity (kW)*1 570 800 1150 1500 2300 2900
Class Output Rated Output Current (A) 100 140 200 260 400 520
Rating Rated Output Voltage 3-phase, 4.16 kV (sinusoidal wave)
Main Circuit Power Supply 3-phase, 4.16 kV ±10%, 50/60 Hz ±5%
Model: CIMR-MV1S C 250 400 630 900 13C 18C 25C 30C 36C 43C 50C
Nominal Capacity (kVA) 400 570 800 1150 1600 2300 3000 3800 4600 5300 6000
6 kV Maximum Applicable Motor Capacity (kW)*1 250 400 630 900 1250 1800 2500 3000 3600 4300 5000
Class Output Rated Output Current (A) 35 50 70 100 140 200 260 330 400 460 520
Rating Rated Output Voltage 3-phase, 6/6.6 kV (sinusoidal wave)
Main Circuit Power Supply 3-phase, 6/6.6 kV ±10%, 50/60 Hz ±5%
MV1S Efficiency / Power Factor Efficiency: Approx. 97% (at rated speed and 100% load), Power Factor: 0.95 or more
Over Load Tolerance 110% / 60 seconds, 120% / 15 seconds
Cooling Method Forced air-cooling by fan (with failure detection)
Control Power Supply 3-phase, 200/220 V or 380/400/440 V ±10% at 50/60 Hz ±5%, 3 kVA or more (Control Power by others)
Control Method Open-loop vector control, flux vector control, V/f control
Main Circuit Voltage type PWM control with multi-output connected in series
Frequency Control Range 0.01 to 120 Hz
Control Frequency Control Accuracy ±0.5%
Specifications Analog Input Resolution 0.03 Hz
Accel/Decel Time 0.1 to 6000 seconds
Restart after momentary power loss*2, torque limit, acceleration stall prevention, speed search, jump frequencies,
Main Control Functions
S-curve accel/decel, multi-step speed control, KEB (kinetic energy braking) function, Energy saving control, etc.
Overcurrent, overvoltage, undervoltage, output ground fault, output open-phase, cooling fan error,
Protective Functions
overload, motor overheat, etc.
Communications Function (optional) Modbus, CP-215 and CP-218 (Ethernet), Profibus
Digital Operator Status display, fault display, run command, parameter setting, parameter reference
Maintainability Display Tools on PC Trend display, data analysis tool
Main Circuit Modular configuration
Input Transformer Class H type, Nominal +5% /+10% tap, secondary multi-phase winding
No. of I/O Terminals Digital input: 10 points; digital output: 8 points; analog inputs: 2; analog outputs: 2
Temperature Protection Power cells: protected by thermistor; Transformer: protected by thermostat

Environmental Conditions
Applicable Standards JIS, JEM, JEC, CSA
Atmosphere General environmental conditions (free from dust, saline and corrosive gases)
Environment

Ambient Temperature -5 to +40°C


Relative Humidity 95% RH or less (without condensation)
Storage Temperature 0 to +50°C
Altitude 1000 m or less for 3 or 6 kV class, 2000 m or less for 4.16 kV class
Cabinet Form Frame and panel construction, vertical-stand alone, with protective inner front panel
Specifications Painting Munsell 5Y7/1 semi-gloss both for inner and outer surfaces
Enclosure IP 40 (dustproof type) for 3 kV and 6 kV class, NEMA 1 for 4.16 kV class
Notes:
*1: Maximum motor output listed is based on Yaskawa standard four-pole motors.
*2: Auto restart after momentary power loss requires an uninterruptive power supply for control power, by others.

8
BL_MV1S_01:BL.AFD.01.qxd 6/24/2009 12:27 PM Page 9

Sugar and Alcohol Steel


The MV1S suits the sugar and alcohol market by providing The MV1S is perfect for the multitude of tasks motors need
a flexible product for both Variable Torque (VT) and to perform when making steel.
Constant Torque (CT) applications in the same package.
Applications:
Applications: - ID and FD Fans
- Screw Conveyor - Pump
- Belt Conveyor - Compressor
- Bulk Material Transfer - Exhaust Fan
- Centrifuge - Strip Mill
- Boiler ID and FD Fans - Winder
- Mills

Water Treatment
Oil and Gas The MV1S is the best solution for water treatment because
The MV1S fits many applications in this market due to its of its features that optimize efficiency in pumping
excellent output waveform. (Better waveform = more applications.
production per kW applied to the motor).
Applications:
Applications: - Booster Pumps
- Electrical Submersible - Influent Pumps
Pump (ESP) - Aeration Systems
- Water Injection Pump - Lift Stations
- Screw Pump (PCP) - Effluent Pumps

Aggregate Mining
The MV1S serves the aggregate market due to its The MV1S helps companies mine gold, silver, copper,
performance flexibility – diamonds, salt and coal.
energy saving for fans and pumps and vector control for
rugged applications, all Applications:
in the same package. - Mills
- Crushers
Applications: - Dredges
- Kilns - Fans
- Crushers - Pumps
- Conveyors - Conveyors
- Fans

9
BL_MV1S_01:BL.AFD.01.qxd 6/24/2009 12:27 PM Page 10

Fig.1 Fig.2
H2

H2
H

H
H1

H1

W Max.685 D W Max.785 D
Dimension with door open Dimension with door open

Fig.3
H2
H
H1

W Max.785 D
Dimension with door open

Fig.4
H2
H
H1

W Max.785 D
Dimension with door open

Fig.5
H2
H
H1

W Max.685 D
Dimension with door open

Units: mm

10
BL_MV1S_01:BL.AFD.01.qxd 10/20/2009 10:40 AM Page 11

Model Dimensions mm Approx. Mass*2


Figure
CIMR-MV1S_ _ W H H1 H2 D kg
132 2000
2300
200 2200
315 Fig. 1 1000 2500
3 kV Class

450 2400 2800


630 3500
2900 2400 500
900 4400
3200 1200
13C 4900
Fig. 2
15C 5300
3600*1
18C 1400 6400
25C Fig. 4 5600*1 9500
570
Fig. 1 3400 1200 3700
800
4.16 kV
Class

11C 2900 2400 500 5500


4900 1400
15C Fig. 2 5900
23C 5500 1600 8100
250 2900
1000
400 3200
630 Fig. 2 3400 3700
900 1200 4500
6 kV Class

13C 5300
18C Fig. 3 4600*1 2900 500 7000
2400 1400
25C 5500*1 8700
30C Fig. 4 9400
6500*1
36C 12000
1600
43C 13600
Fig. 5 8000*1
50C 3150 750 16000
*1: Block construction.
*2: A value for the approx. mass shows the maximum value.

CIMR - MV1S

Inverter Nominal Motor Capacity (kW)


132 (132kW) 450 (450kW) 11C (1150kW) 29C (2900kW)
200 (200kW) 570 (570kW) 13C (1250kW) 30C (3000kW)
250 (250kW) 630 (630kW) 15C (1500kW) 36C (3600kW)
315 (315kW) 800 (800kW) 18C (1800kW) 43C (4300kW)
MV Drive series 400 (400kW) 900 (900kW) 23C (2300kW) 50C (5000kW)
25C (2500kW)

Input voltage, Frequency Nominal output voltage

A: 3.3kV, 60Hz B: 3kV, 50Hz A: 3/3.3kV


C: 6.6kV, 60Hz D: 6kV, 50Hz B: 4.16kV
E: 3.3kV, 50Hz F: 6.6kV, 50Hz C: 6/6.6kV
H: 10.5kV, 50-60Hz (in development) H: 10.5kV
L: 4.16kV, 50-60Hz

11
BL_MV1S_01:BL.AFD.01.qxd 6/24/2009 12:23 PM Page 16

Distributed by:

Enertia Engineering Ltd.


#105, 117 Pembina Road
Sherwood Park, AB
T8H 0J4 Canada
Phone: 780-467-0303
Fax: 780-401-3519
Toll-Free: 1-866-796-0303

Yaskawa Motoman Canada


298 Labrosse
Pointe-Claire, Quebec H9R 5L8
800-854-4124 Fax: 514-693-9212
Bulletin BL.MV1S.01 © 2009 Yaskawa Motoman Canada 10/15/09