J5 J6 J7 J8
J11
FIRE ALARM ANNUNCIATOR
J10
ALARM ZONE 3
78
23
2 10 2 10 456
ALARM ZONE 7 J2
90 1
78
23
Alarm Zone Alarm Zone Alarm Zone Alarm Zone SW2
ALARM ZONE 8
456
3 11 3 11
1
2
ALARM ZONE 9
3
SW3
Power-limited,
4
Alarm Zone Alarm Zone Alarm Zone Alarm Zone
5
6
ALARM ZONE 10 4 12 4 12
7
8
SW4
ALARM ZONE 11
Alarm Zone Alarm Zone Alarm Zone Alarm Zone
5 13 5 13
ALARM ZONE 12 TB2
supervised
ALARM ZONE 13 Alarm Zone Alarm Zone Alarm Zone Alarm Zone
EIA-232
6 14 6 14
ALARM ZONE 15
ALARM ZONE 16
24 VDC Alarm Zone
7
Alarm Zone
15 24 VDC Alarm Zone
7
Alarm Zone
15 24 VDC TB1
Form-C Relays
AFM-16AF ACM Series AFM Series LDM-32F
15210 51480 15970 50055
Color Legend CRF-300
UNIVERSAL DIGITAL ALARM COMMUNICATOR/TRANSMITTER
EIA-485
COMM. FAIL
KISS OFF
F300-04-00
Operating Power
Appliance Circuits 24 VDC
CLEAR
1
4
7
5
8
2
TEST
3
6
9
E
F
D
MODE
1st
EIA-485
Control Module for
EVENT
Terminal Mode
NAC #1 activating Notification NAC
(text) Configuration Information (Programmable Alarm & Trouble) UDACT-F Power-limited, supervised Appliances
Style Y (shown) 24 VDC
50049 NFPA Style 4
24 VDC
or Style Z Contact Ratings:
DC Power Outputs (24 VDC) 3 amps max. NAC #2 SLCLoop CMF-300
2.0 amps @ 30 VDC (resistive)
EIA-485
Style Z (shown) F300-07-00
Supervise with a power supervision relay A77-716B 4.7K, ½W 0.5 amps @ 30 VAC (resistive)
ELR or Style Y Refer to the SLC Wiring Manual,
Nonresettable Power #2 - 24 VDC filtered, 3 amps max. Document 51309, for detailed
Contacts shown below in normal Ack/Step Silence Drill Reset
24 VDC
Hold 2 sec.
power-limited (3 amps max). Supervision + + condition (AC power with no alarm, information on wiring intelligent Monitor Module for
conventional Two-Wire IDC
required. Suitable for powering annunciators. trouble or supervisory activity). devices and the SLC Loop for
OUT
Smoke Detectors 24 VDC
NFPA Style 4, 6 and 7.
Nonresettable Power #1 - 24 VDC filtered, 24 VDC
O
N
1 2
FF O
O 1
F
F
2 3 4 5 6 7 8
Cable P/N:
+ + A Fail Safe Trouble NC NO C MMF-302
EIA-485 Return
power-limited (3 amps max). Supervision PRT/PK
relay switches to the F300-03-00
required. Suitable for powering annunciators. NO position during
Ack/Step Silence Drill
Hold 2 sec.
Reset
EIA-485
devices of the Normally
IDC
EIA-485
detectors (IDC). Supervision required. Alarm* Trouble Supervisory* Open Contact type
NO NC C NC NO C NO NC C R W G B
MDF-300
F300-09-00
+ - + - + - + + - - + + - - + - T R D G + - +
O
-
O
+ + - - shield
B A A B B A A B X C T N I I B A B A A B Monitor Module for conventional
TB3 V R D N N U U
TB4 TB5 TB6 TB7 T T TB8 initiating devices of the Normally
Open Contact type (pull stations,
IDC
JP3 (*Factory default relay programming heat detectors, 4-wire smokes, etc.)
Cut this jumper to disable the as shown on circuit board)
MS-9600 internal battery charger MMF-300
CUT TO
DISABLE when using an external charger. Cut this jumper to enable F300-02-00
LOCAL
CHARGER JP5 Supervisory relay when
JP6 4XTMF module is installed.
Photoelectric Smoke Detector and
Cut this jumper to supervise Photoelectric Smoke Detector with
Connectors for 4XTMF option module the 4XTMF module when Thermal element.
installed (see J10 & J11). SD350 & SD350T
J10 J11 F300-14-00
Ionization Detector
ACK/STEP
1 2 3 1st FIRE
DISABLE
GND FLT
J2 Connector for Optional 2nd
ABC DEF EVENT Manual Pull Station
OPT DACT ALARM
BD Signaling Line Circuit Module
SILENCE
4 5 6 CLR (Future Use)
SLC OPT BD
BG-12LX
ENTER
J16 & J17- Auxiliary Trouble GHI JKL MNO
SW1 - Flash Memory Load Enable Switch 51049
Bus Connection (located under J17 J16 DRILL (located under membrane panel)
7 8 9 ESC
membrane panel) J6 J8 SW1 UP is normal position for switch.
HOLD 2 SEC
DOWN position allows loading of
PRS TUV WXY
LCD DISPLAY
factory software upgrades.
KEYPAD I/F Duct Detector
MODE
* 0 # TB1 TB2 RESET
D350P & D350RP
QZ -/. F300-10-00 & F300-11-00
J3
RECALL
CB1 HOT NEUT EARTH +BATTERY- J7 Esc F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Print
Scrn
Scroll
Lock Pause
Num Caps Scroll
Lock Lock Lock
~ _ +
PS2 Keyboard Interface
! @ # $ % ^ & * ( ) Page
- Num
AC Power
= Backspace Insert -
Battery
1 4 5 6 8 9 0 Home /
` 2 3 7 Up
Lock *
Tab Q W E R T Y U I O P [
{
]
} | Delete Page
\ End Down
7 8 9
Caps :
+
A S D F G H J K L " Enter 5 6
Lock 4
Filename: 51537-C0.cdr