You are on page 1of 1

ACS

J5 J6 J7 J8

J11
FIRE ALARM ANNUNCIATOR
J10

DB9F- For printing to an EDP-listed printer or uploading/downloading


LOCAL SILENCE LOCAL SILENCE
J4
ALARM ZONE 1 AND
ACKNOWELDGE
AND
ACKNOWELDGE
KEYSWITCH
LAMP
TROUBLE / ON L INE TROUBLE / ON L INE POWER J9
ALARM ZONE 2 SUPERVISORY SUPERVISORY

ALARM ZONE 3

through a Personal Computer. 50-foot max within same room.


EIA-485 EIA-485 EIA-485 EIA-485
Mode
ALARM ZONE 4
Alarm Zone Alarm Zone Alarm Zone Alarm Zone SWITCH
ALARM ZONE 5 1 9 1 9 MATRIX
J1
ALARM ZONE 6 Alarm Zone Alarm Zone Alarm Zone Alarm Zone 90 1

(For conection to a 25-pin COM port, use DB9M to DB25F adapter)


SW1

78

23
2 10 2 10 456
ALARM ZONE 7 J2
90 1

78

23
Alarm Zone Alarm Zone Alarm Zone Alarm Zone SW2
ALARM ZONE 8
456

3 11 3 11

1
2
ALARM ZONE 9

3
SW3

Power-limited,

4
Alarm Zone Alarm Zone Alarm Zone Alarm Zone

5
6
ALARM ZONE 10 4 12 4 12

7
8
SW4
ALARM ZONE 11
Alarm Zone Alarm Zone Alarm Zone Alarm Zone
5 13 5 13
ALARM ZONE 12 TB2

supervised
ALARM ZONE 13 Alarm Zone Alarm Zone Alarm Zone Alarm Zone

EIA-232
6 14 6 14

24 VDC ALARM ZONE 14

ALARM ZONE 15

ALARM ZONE 16
24 VDC Alarm Zone
7
Alarm Zone
15 24 VDC Alarm Zone
7
Alarm Zone
15 24 VDC TB1

Alarm Zone Alarm Zone Alarm Zone Alarm Zone ON LINE

MS-9600 Basic System Connections


PRESS 8 16 8 16
SYSTEM TROUBLE TO

Control Module with two


SILENCE
ON LINE

Form-C Relays
AFM-16AF ACM Series AFM Series LDM-32F
15210 51480 15970 50055
Color Legend CRF-300
UNIVERSAL DIGITAL ALARM COMMUNICATOR/TRANSMITTER

(number) Installation Document Number 24 VDC Notification POWER

EIA-485
COMM. FAIL

KISS OFF
F300-04-00
Operating Power
Appliance Circuits 24 VDC
CLEAR

1
4
7
5
8
2
TEST

3
6
9
E
F

D
MODE

1st
EIA-485
Control Module for
EVENT

Communications Circuit Form-C Relays A O B C ENTER


STORE

Terminal Mode
NAC #1 activating Notification NAC
(text) Configuration Information (Programmable Alarm & Trouble) UDACT-F Power-limited, supervised Appliances
Style Y (shown) 24 VDC
50049 NFPA Style 4

24 VDC
or Style Z Contact Ratings:
DC Power Outputs (24 VDC) 3 amps max. NAC #2 SLCLoop CMF-300
2.0 amps @ 30 VDC (resistive)

EIA-485
Style Z (shown) F300-07-00
Supervise with a power supervision relay A77-716B 4.7K, ½W 0.5 amps @ 30 VAC (resistive)
ELR or Style Y Refer to the SLC Wiring Manual,
Nonresettable Power #2 - 24 VDC filtered, 3 amps max. Document 51309, for detailed
Contacts shown below in normal Ack/Step Silence Drill Reset

24 VDC
Hold 2 sec.

power-limited (3 amps max). Supervision + + condition (AC power with no alarm, information on wiring intelligent Monitor Module for
conventional Two-Wire IDC
required. Suitable for powering annunciators. trouble or supervisory activity). devices and the SLC Loop for

OUT
Smoke Detectors 24 VDC
NFPA Style 4, 6 and 7.
Nonresettable Power #1 - 24 VDC filtered, 24 VDC
O
N
1 2
FF O
O 1
F
F
2 3 4 5 6 7 8

Cable P/N:
+ + A Fail Safe Trouble NC NO C MMF-302

EIA-485 Return
power-limited (3 amps max). Supervision PRT/PK
relay switches to the F300-03-00
required. Suitable for powering annunciators. NO position during
Ack/Step Silence Drill
Hold 2 sec.
Reset

trouble conditions and ACM-8RF


Resettable Power - 24 VDC filtered, + 50362 LCD-80F Dual Monitor Module for IDC
+ under loss of all power. 51338 NFPA Style 6 Return conventional initiating
power-limited (3 amps max) to smoke

EIA-485
devices of the Normally
IDC

EIA-485
detectors (IDC). Supervision required. Alarm* Trouble Supervisory* Open Contact type
NO NC C NC NO C NO NC C R W G B
MDF-300
F300-09-00
+ - + - + - + + - - + + - - + - T R D G + - +
O
-
O
+ + - - shield
B A A B B A A B X C T N I I B A B A A B Monitor Module for conventional
TB3 V R D N N U U
TB4 TB5 TB6 TB7 T T TB8 initiating devices of the Normally
Open Contact type (pull stations,
IDC

JP3 (*Factory default relay programming heat detectors, 4-wire smokes, etc.)
Cut this jumper to disable the as shown on circuit board)
MS-9600 internal battery charger MMF-300
CUT TO
DISABLE when using an external charger. Cut this jumper to enable F300-02-00
LOCAL
CHARGER JP5 Supervisory relay when
JP6 4XTMF module is installed.
Photoelectric Smoke Detector and
Cut this jumper to supervise Photoelectric Smoke Detector with
Connectors for 4XTMF option module the 4XTMF module when Thermal element.
installed (see J10 & J11). SD350 & SD350T
J10 J11 F300-14-00

Ionization Detector

AC POWER MAINTENANCE CP350


FIRE ALARM ALARM F300-15-00
FIRE-LITE ALARMS INC SILENCED

SYSTEM ALL NORMAL SUPERVISORY DISABLED


10:00A 010801 TROUBLE BATTERY Heat Detector (fixed) and
To disable ground fault detection, Heat Detector with Rate-Of-Rise
remove jumper/shunt from JP2 GROUND
(located under membrane panel) H350 & H350R
JP2 F300-12-00 & F300-13-00

ACK/STEP
1 2 3 1st FIRE
DISABLE
GND FLT
J2 Connector for Optional 2nd
ABC DEF EVENT Manual Pull Station
OPT DACT ALARM
BD Signaling Line Circuit Module
SILENCE
4 5 6 CLR (Future Use)
SLC OPT BD

BG-12LX
ENTER
J16 & J17- Auxiliary Trouble GHI JKL MNO
SW1 - Flash Memory Load Enable Switch 51049
Bus Connection (located under J17 J16 DRILL (located under membrane panel)
7 8 9 ESC
membrane panel) J6 J8 SW1 UP is normal position for switch.
HOLD 2 SEC
DOWN position allows loading of
PRS TUV WXY
LCD DISPLAY
factory software upgrades.
KEYPAD I/F Duct Detector
MODE
* 0 # TB1 TB2 RESET
D350P & D350RP
QZ -/. F300-10-00 & F300-11-00
J3
RECALL

CB1 HOT NEUT EARTH +BATTERY- J7 Esc F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Print
Scrn
Scroll
Lock Pause
Num Caps Scroll
Lock Lock Lock

~ _ +
PS2 Keyboard Interface
! @ # $ % ^ & * ( ) Page
- Num

AC Power
= Backspace Insert -

Battery
1 4 5 6 8 9 0 Home /
` 2 3 7 Up
Lock *
Tab Q W E R T Y U I O P [
{
]
} | Delete Page
\ End Down
7 8 9
Caps :
+
A S D F G H J K L " Enter 5 6
Lock 4

CAUTION! HIGH VOLTAGE 120 VAC, 60 HZ, 3.2 amps


Shift
Ctrl
Z
Alt
X C V B N M
, . ?
Alt
Shift
Ctrl
1
0
2
.
3
Enter

24 VDC, 25 Amp Hour maximum

Filename: 51537-C0.cdr