030-300380 Rev. B, August 2005
- Installation Guide -
DSAWM-204PBI2 4-Slot-Mounting Kit with Lightning Protection
1. GENERAL
- NOTE -
Hereafter, the DSAWM-204PBI2 4-Slot-Mounting Protection
Kit may be referred to as the Protect 4" kit or mounting.
- PRECAUTIONARY STATEMENT -
- Never install telephone wiring during a lightning storm.
Network
- Never install telephone jacks in wet locations unless the jack is Area/Side
specifically designed for wet locations.
- Never touch uninsulated telephone wires or terminals unless
the telephone line has been disconnected at the network
interface.
- Use caution when installing or modifying telephone lines.
- This equipment is intended to be used behind devices that
provide primary lightning protection.
- This installation should conform to Local Codes and NEC 4-slot
Mounting
requirements. Assembly
- This equipment is to be installed in a restricted access location.
CAUTION
Risk of electric shock. Voltages up to 140 VDC (with reference to
ground) may be present on telecommunications circuits.
Customer
Area/Side
Important Safety Instructions (Please Save)
When using your telephone/telecommunications equipment, al-
ways follow basic safety instructions to reduce risk of fire,
electric shock, and injury to person, including the following: Lightning
Kit Mounting Protector RJ48 RJ48 Mounting Holes
Plate Block** Switches Jacks (4)
A. Read and understand all instructions. (4)
** Protector Modules not provided.
B. Follow all warnings and instructions marked on product.
C. Do not place this product on an unstable cart, stand or table: the Figure 2. Protect 4 Kit Front View & Features
product may fall, causing serious damage to product.
D. Slots and openings are provided for ventilation. To protect from
overheating, these openings must not be blocked or covered. This
product should never be placed near or over a radiator or heat reg-
ister. This product should not be placed in a built-in installation Non-combustible
unless proper ventilation is provided. backboard
E. This product should be operated only from the type of power Mounting
source indicated on the marking label. Screws (4)
F. Never push objects into this product through assembly slots as they
may touch dangerous voltage points or short out parts that could
result in the risk of fire or electrical shock. Never spill liquid of any
kind on the product.
G. For mounting by trained service personnel in restricted access loca-
tions only. Kit
2.3 Determining the Mounting Location & Type 4. Partially install the mounting screws or wall fasteners.
Verify that the mounting screw head (or toggle bolt head)
can fit through the round, largest part of the key-hole
The kit should be installed by authorized trained personnel in re- shaped mounting hole in the kit mounting plate. Partially
stricted access locations only. In accordance with UL 60950, this install all screws (or wall fasteners), leaving approximately
equipment is suitable for mounting on concrete or other non- ¼-inch of the screw protruding from the wall.
combustible surfaces only. It is recommended that adequate
horizontal and vertical space be left between multiple installa- 5. Attach kit to wall (hang the kit on the screws).
tions to allow for unobstructed personnel access, proper cable Lift the kit and align the kit’s mounting plate holes with the
access, and ventilation. Select a location on a wall which insures protruding screws on the wall, then carefully hang the kit on
maximum and adequate lighting, air flow, and heat dissipation. the screws.
The distance from the cable entry point should be consistent
with local installation practices. 6. Finish driving screws.
While holding the kit in place, immediately finish driving all
screws the remaining distance until flush against the wall.
Do not turn the screws too tight.
2.4 Mounting on a Wall
2.5 Making Ground Connections
The kit can be directly mounted to a wall. The wall type may be
wood, drywall, or a noncombustible surface such as concrete. Ground connections are made via #6 AWG wire either to the
The Protect 4 kit should be installed according to local company ground lug located in the top right-hand corner of the kit plate
practices; however, if none exist, the kit may be installed as de- or to the ground stud located in the top left-hand corner of the
scribed in the following steps. Refer to Figure 3 as needed. kit plate. This will provide a common ground for the mounting.
1. Determine the exact mounted location on wall. 2.6 Making Installer Wiring Connections
Review Paragraph 2.3 and also note that the kit should be
installed so that the module assembly is in the upright (ver-
2.6.1 Network Side Connections. Network side wiring con-
tical) position.
nections are made to a terminal block or strip located at the top
of the kit. Circuit 1 is on the left side of the strip/block, and Cir-
2. Mark the mounting hole locations to be drilled. cuits 4 is on the right side. Strip an adequate length of #12-24
Using the kit itself as a template, lift the kit to the desired AWG wire, then secure and tighten each wire under the ap-
location and mark the exact mounting hole locations to be propriate screw head. The terminal strip/block is prewired to
drilled for the mounting hardware. The installer may the lightning protector block, which is prewired to the module
choose from eight mounting holes, for mounting flexibility. mounting assembly. See Figure 4 and Table 1 for circuit/block
Set aside the kit. position details.