BOREHOLE Nº :
Client: PACKER TEST
Client: PACKER TEST
Lumina Copper SAC FORM
Project Number:
Project Number: Task
Task 2000:
Geotechnical and Hydrogeological Subsurface Investigation
FORM PT-
PT-1
GENERAL INFORMATION BOREHOLE INFORMATION TEST INFORMATION
GENERAL INFORMATION BOREHOLE INFORMATION TEST INFORMATION
Contractor Company:
Contractor Company: North
North (m):
(m): - Inclination/H
Inclination/H (α):
( ) : 70 Depth of the Test From (m):
Depth of the Test: From (m)
30.00 to (m): 35.00 RQD%:
to (m)
Field
FieldResponsible ofContractor:
Responsible of Contractor: East
East (m):
(m): - Location:
Location: UNC Initial
Initial Hour:
Hour: 11:30 d top: 30.00d top:m. h soil (m):
Field
Field Engineer MWH: Maldonado Lopez, Carlos Alonso
ofMWH: Elevation (m): - BarehoIe Diameter (2r): 9.61 End
End Hour: 1:30 d bottom: 35.00 m. h rock (m):
Engineer of Elevation(m): Borehole Diameter (2 r) : cm Hour: d bottom:
Date:
Date: 26-Jun-2017 Turn Day/Night: Day Azimuth:
Azimuth: N315 GWI (m): 34 hm
hm(m):
(m): 0.35 L (m): 5.00
L: a (m):
GWL (m) :
Packer Inflation Pressure = Pp
Pressure Gauge Flowmeter Expansion Cylinder
Valves 1. Ph = (d top + a) psi Hydrostatic Pressure on the Packer & Convert 1psi = 0
Pump 2. Pw 200 psi Packer Working Pressure
3. Pp = (Ph + Pw)*1.2 psi Packer Inflation Pressure
105.94 ft
1.15 ft
101.32 ft
(satured test)
G.W.L.
HSoil 6. PM = % Pmax wich is dependant on RQD
If RQD is >75% in the test zone then: P M1 = 25% Pmax P M2 = 50% Pm
104.79
(dry test) 6. Packer can only be setted in rock that has an RQD > 60%
7. soil = 100 pcf
100.17 ft
1.- σt =
(0.62 x 100 + 99.55 x 140)
= 97.22 ft . Psi
PM : Surface Gauge Pressure
144 RFlowmeter : Flow Meter Reading
q : Change in Flow Meter Reading
Hw : D e p t h f r o m G W L t o L / 2 ( S a t u r e d T e s t )
2.- u =
(0.62 + 99.55) - 104.79
= -2 ft . Psi a : Heigth of casing above the ground (stick up)
144
PACKER TEST
C
ce Investigation
FORM
TEST INFORMATION
PT-1
TEST INFORMATION
76
Depth of the Test: From (m) to (m)
Initial Hour: d top: 0.20
32.30
r) : cm End Hour: d bottom:
hm (m): L: 2.1
= 43.27 psi
-------------
23.00
23.00
23.00
23.00
23.00
Revision Date: February 17, 2010
Revised by: K. Gudenkauf
Checked by: C. Brueckman PACKER TEST 0
Reviewed by: H. Ramirez
FLOW METER
PRESSURE GAUGE
hm = Height of the Gauge Pressure 0.35 m.
a = Height above of the surface 2.10 m.
G.W.L. = Ground Water Level 34.00 m.
Pump
H(Gravity) = Distance from ground-water level to swivel 34.95 m.
hm dTOP = Depth from ground surface to top of testing zone 30.00 m.
H(Gravity)
a dBOTTOM = Depth from ground surface to bottom of testing zone 35.00 m.
If G.W.L. is above test = Inclination with the horizontal 70 deg
zone
G.W.L. H(Gravity) corrected = SIN x H(Gravity) 32.84 m.
L = Length of the portion of the hole tested 5.00 m.
dTOP H(Gravity) If G.W.L.is 2r = Two times the radius of hole tested (Diameter) 9.61 cm.
below test zone PM = Gauge Pressure
G.W.L. Dp = Head Loss
q = Volume in liters during the test
L
K(cm/s)
L/2 0.000E+00 5.000E-05 1.000E-04 1.500E-04
d BOTTOM
1
2r
2
30.00
Grouting," A.C. Houlsby 73.64 25.8
20.00
10.00 59.64 23.0
0.00
22.0 23.0 24.0 25.0 Q (l/min)
26.0 27.0 28.0 29.0