You are on page 1of 9

Borehole No. / Trial Pit No.

Issued by :

Checked by :
Sample Number

B - denotes bulk sample

S - denotes SPT sample


Sample Top Depth

FORM #: FO-EN-004
D - denotes disturbed sample
Sample Details

Specimen depth
FUGRO MIDDLE EAST
Schedule of Laboratory Tests

0
0
Moisture content ( BS 1377:P.2)

0
0
Density/ Unit weight (BS 1377:P.4)

0
0
Particle density (BS 1377:P2)

0
0
Atterberg limits (BS 1377:Part 2)

W- denotes water Sample


Classification

0
0
Sieve analysis (BS 1377:P2)

U- denotes undisturbed sample


0
0
Hydrometer analysis (BS 1377:P2)

0
0
Organic content (BS 1377:P3)

0
0
Water soluble Sulphate (BS 1377:P3)

0
0
Water Soluble Chloride ( BS 1377:P3)

0
0

Notes:
ph ( BS 1377:P3)

REV NO: 02
0
0
Acid Soluble Sulphate ( BS 1377:P3)
Chemical

0
0
Acid soluble Chloride ( BS 1377:P3)

0
0
Carbonate content ( BS 1377:P3)

Oedometer/Consolidation ( BS 1377:P5)

Triaxial test, UU 100mm single stage without

0
0
PP measurement (BS 1377:P7/P8)

Triaxial test , UU -38mm dia, multi stage


0
0

with PP measurement ( BS 1377:P7/8)

Page 1 of 2
Triaxial test, CU with PP measurement,
0
0

multi stage ( BS 1377:P7)


0
0

Direct Shear Test, 60 x 60mm ( BS 1377:P7)


Compressibility and Shear Strength

REV DATE: FEB '15


0
0

MDD/OMC - 4.5kg rammer (BS 1377:P4)


Client :
0
0

Project :
Compaction

CBR test (BS 1377:P4)


Project No :
0
0

UCS on rock ( ASTM D 7012)


Site/Location :

UCS on rock with deformation measurement


0
0

(ASTM D7012-14)
0
0

Point Load Index (ASTM D5731-95)


Rock testing
Other Tests

Total

To date
Previous

Date submitted :
BOQ quantities
Remarks

AUTHORISED BY: EM
Schedule No: 06
P24-01-PD Borehole No. / Trial Pit No.

Notes:
Issued by :

Checked by :
C9
C8
C7
C6
C5
C4
C3
C2
C1
Sample Number

C18
C17
C16
C15
C14
C13
C12
C11
C10

SPT7
SPT6
SPT5
SPT4
SPT3
SPT2
SPT1

011E41FO-EN-004 | Rev 03 | 07 January 2020


Sample Top Depth

SBL
SBL

8.85
8.50
7.00
5.50
4.00
2.50
1.00

28.00
26.50
25.00
23.50
22.26
22.00
20.50
19.00
17.90
17.50
16.00
14.90
14.50
13.00
11.50
10.00
Project No. : PU-21-0059-MV

Sample Bottom Depth

SBL

8.85
7.45
7.00
5.50
4.00
2.50
1.00

29.50
28.00
26.50
25.00
23.50
22.26
20.95
20.50
19.00
17.90
17.50
16.00
14.90
14.50
13.00
11.50
10.00
Sample Details

Specimen depth

5.20-5.45

25.30-25.55
Moisture content (ASTM D2216)

6
0
6
X
X
X
X
X
X

305
Bulk Density - Undisturbed Sample (ISO

0
0
0

305
17892:pt2)

6
0
6
X
X
X
X
X
X
Particle density (ASTM D854)

305
Project Title : Greater Male Connectivity Male to Thilafushi Link Project

Atterberg limits (ASTM D4318)

4
0
4
X
X
X
X

305
Classification

Sieve analysis, wet sieving

6
0
6
X
X
X
X
X
X

305
(ASTM D422)
Schedule of Laboratory Tests for Pre-Drill

particle size distribution of fine grained

4
0
4
X
X
X
X

305
soils by hydrometer method (ASTM D422)

-
0
0
0
pH value of soil/rock (IS 2720:pt26)

Total Sulphate content on soil/rock

-
0
0
0
(IS 2720:pt27)

Water soluble Sulphate

-
0
0
0
(IS 3025:pt24)
Water Soluble Chloride Soil/Rock

-
0
0
0
(IS 3025:pt32)
Carbonate content Soil/Rock

7
0
7
X
X
X
X
X
X
X

1140
(IS 2720:pt23)

-
0
0
0
Organic Matter Content (IS 3025:pt18)
Chemical

Magnesium content in 2:1 water-soil extract

-
0
0
0
(IS 3025:pt46)
Mass loss on ignition

-
0
0
0
(BS 1377:pt3, Clause 4)

011E41
Electrical Conductivity/

-
0
0
0
Resistivity of fine grained soils
(IS 3025:pt14)
Redox potential

-
0
0
0
(BS 1377:pt3, clause11)

-
0
0
0
Total Dissolved solids (BS 1377:pt3)

Direct shear strength test on soil sample

-
0
0
0
Client

(IS 2720:pt13)

Protocr Test Modified/Standard

-
0
0
0

(ASTM D1557/698
Compaction Test

California Bearing Ratio [CBR]


-
0
0
0
Soil Strength Tests /

(ASTM D1883)
Location : Male, Maldives

-
0
0
0

Natural water Content (IS 13030)

Porosity/bulk and intact dry density


-
0
0
0

(IS 13030)
: Afcons Infrastructure Limited

Rock Testing

-
0
0
0

Specific gravity of solids (IS 1122)

UCS on rock with deformation


0
0
0

342

measurement (IS 9143 & IS9221)

Lab Slaking Test on rock sample


0
0
0

342

(IS 10050)
Diametral Point Load Strenght Test
1
0
1
X

342

(IS 18764)
Axial Point Load Strenght Test
0
0
0

342

(IS 18764)
Brazilian Tensile Strength Test
-
0
0
0

S - denotes SPT sample


B - denotes bulk sample

(IS 10082)
D - denotes disturbed sample
2
0
2
X
X

Slake Durability (IS 10050)


342
2
0
2
X
X

Jar Slake Durability


342

Determination of Rock Hardness by


2
0
2
X
X

732

Rebound Hammer Method


8
1
1
0

pH (IS 3025:pt11)
8
0
0
0

Salinity (IS 3025:pt32)


8
0
0
0

Sulfates (SO4 2), mg/L (IS 3025:pt11)

Magnesium (Mg2+), mg/L (IS


8
0
0
0
Date submitted to lab

3025:pt46)
Date submitted to client :
:

8
0
0
0

Total Dissolved Salts (TDS)


Ground Water Testing

Electrical Conductivity, mS/m (IS


8
0
0
0

C - denotes core samples

3025:pt14)
W- denotes water sample
U - denotes undisturbed sample
P24-01-PD Borehole No. / Trial Pit No.

Notes:
Issued by :

Checked by :
Sample Number

C41
C40
C39
C38
C37
C36
C35
C34
C33
C32
C31
C30
C29
C28
C27
C26
C25
C24
C23
C22
C21
C20
C19

SPT9
SPT8

011E41FO-EN-004 | Rev 03 | 07 January 2020


Sample Top Depth

64.00
62.50
61.00
59.50
58.00
56.50
55.00
53.50
52.00
50.50
49.00
47.50
46.00
44.50
43.00
41.50
40.00
38.50
37.00
35.50
34.25
34.00
32.50
31.00
29.50

0
0
Project No. : PU-21-0059-MV

Sample Bottom Depth

65.50
64.00
62.50
61.00
59.50
58.00
56.50
55.00
53.50
52.00
50.50
49.00
47.50
46.00
44.50
43.00
41.50
40.00
38.50
37.00
35.50
34.25
32.95
32.50
31.00
Sample Details

Specimen depth

64.85-65.05
60.10-60.35
52.70-53.10
50.95-51.15
49.70-50.25
Moisture content (ASTM D2216)

8
6
2
X
X

305
Bulk Density - Undisturbed Sample (ISO

0
0
0

305
17892:pt2)

7
6
1
X

Particle density (ASTM D854)

305
Project Title : Greater Male Connectivity Male to Thilafushi Link Project

Atterberg limits (ASTM D4318)

6
4
2
X
X

305
Classification

Sieve analysis, wet sieving

8
6
2
X
X

305
(ASTM D422)
Schedule of Laboratory Tests for Pre-Drill

particle size distribution of fine grained

7
4
3
X
X
X

305
soils by hydrometer method (ASTM D422)

-
0
0
0
pH value of soil/rock (IS 2720:pt26)

Total Sulphate content on soil/rock

-
0
0
0
(IS 2720:pt27)

Water soluble Sulphate

-
0
0
0
(IS 3025:pt24)
Water Soluble Chloride Soil/Rock

-
0
0
0
(IS 3025:pt32)
Carbonate content Soil/Rock

7
7
X
X
X
X
X
X
X

14
1140
(IS 2720:pt23)

-
0
0
0
Organic Matter Content (IS 3025:pt18)
Chemical

Magnesium content in 2:1 water-soil extract

-
0
0
0
(IS 3025:pt46)
Mass loss on ignition

-
0
0
0
(BS 1377:pt3, Clause 4)

011E41
Electrical Conductivity/

-
0
0
0
Resistivity of fine grained soils
(IS 3025:pt14)
Redox potential

-
0
0
0
(BS 1377:pt3, clause11)

-
0
0
0
Total Dissolved solids (BS 1377:pt3)

Direct shear strength test on soil sample

-
0
0
0
Client

(IS 2720:pt13)

- Protocr Test Modified/Standard


0
0
0

(ASTM D1557/698
Compaction Test

California Bearing Ratio [CBR]


-
0
0
0
Soil Strength Tests /

(ASTM D1883)
Location : Male, Maldives

-
0
0
0

Natural water Content (IS 13030)

Porosity/bulk and intact dry density


-
0
0
0

(IS 13030)
: Afcons Infrastructure Limited

-
0
0
0

Specific gravity of solids (IS 1122)

UCS on rock with deformation


3
0
3
X
X
X

342

measurement (IS 9143 & IS9221)

Lab Slaking Test on rock sample


0
0
0

342

(IS 10050)
Diametral Point Load Strenght Test
3
1
2
X
X

342

(IS 18764)
Axial Point Load Strenght Test
2
0
2
X
X
Rock Testing

342

(IS 18764)
Brazilian Tensile Strength Test
-
0
0
0

S - denotes SPT sample


B - denotes bulk sample

(IS 10082)
D - denotes disturbed sample
5
2
3
X
X
X

Slake Durability (IS 10050)


342
4
2
2
X
X

Jar Slake Durability


342

Determination of Rock Hardness by


5
2
3
X
X
X

732

Rebound Hammer Method


8
1
1
0

pH (IS 3025:pt11)
8
0
0
0

Salinity (IS 3025:pt32)


8
0
0
0

Sulfates (SO4 2), mg/L (IS 3025:pt11)

Magnesium (Mg2+), mg/L (IS


8
0
0
0
Date submitted to lab

3025:pt46)
Date submitted to client :
:

8
0
0
0

Total Dissolved Salts (TDS)


Ground Water Testing

Electrical Conductivity, mS/m (IS


8
0
0
0

C - denotes core samples

3025:pt14)
W- denotes water sample
U - denotes undisturbed sample
P24-01-PD Borehole No. / Trial Pit No.

Notes:
Issued by :

Checked by :
Sample Number

C48
C47
C46
C45
C44
C43
C42

011E41FO-EN-004 | Rev 03 | 07 January 2020


Sample Top Depth

74.50
73.00
71.50
70.00
68.50
67.00
65.50

0
0
Project No. : PU-21-0059-MV

Sample Bottom Depth

76.00
74.50
73.00
71.50
70.00
68.50
67.00
Sample Details

Specimen depth

72.30-72.60
70.90-71.10
Moisture content (ASTM D2216)

8
8
0

305
Bulk Density - Undisturbed Sample (ISO

0
0
0

305
17892:pt2)

7
7
0
Particle density (ASTM D854)

305
Project Title : Greater Male Connectivity Male to Thilafushi Link Project

Atterberg limits (ASTM D4318)

6
6
0

305
Classification

Sieve analysis, wet sieving

8
8
0

305
(ASTM D422)
Schedule of Laboratory Tests for Pre-Drill

particle size distribution of fine grained

7
7
0

305
soils by hydrometer method (ASTM D422)

-
0
0
0
pH value of soil/rock (IS 2720:pt26)

Total Sulphate content on soil/rock

-
0
0
0
(IS 2720:pt27)

Water soluble Sulphate

-
0
0
0
(IS 3025:pt24)
Water Soluble Chloride Soil/Rock

-
0
0
0
(IS 3025:pt32)
Carbonate content Soil/Rock

2
X
X

16
14

1140
(IS 2720:pt23)

-
0
0
0
Organic Matter Content (IS 3025:pt18)
Chemical

Magnesium content in 2:1 water-soil extract

-
0
0
0
(IS 3025:pt46)
Mass loss on ignition

-
0
0
0
(BS 1377:pt3, Clause 4)

011E41
Electrical Conductivity/

-
0
0
0
Resistivity of fine grained soils
(IS 3025:pt14)
Redox potential

-
0
0
0
(BS 1377:pt3, clause11)

-
0
0
0
Total Dissolved solids (BS 1377:pt3)

Direct shear strength test on soil sample

-
0
0
0
Client

(IS 2720:pt13)

- Protocr Test Modified/Standard


0
0
0

(ASTM D1557/698
Compaction Test

California Bearing Ratio [CBR]


-
0
0
0
Soil Strength Tests /

(ASTM D1883)
Location : Male, Maldives

-
0
0
0

Natural water Content (IS 13030)

Porosity/bulk and intact dry density


-
0
0
0

(IS 13030)
: Afcons Infrastructure Limited

-
0
0
0

Specific gravity of solids (IS 1122)

UCS on rock with deformation


5
3
2
X
X

342

measurement (IS 9143 & IS9221)

Lab Slaking Test on rock sample


0
0
0

342

(IS 10050)
Diametral Point Load Strenght Test
5
3
2
X
X

342

(IS 18764)
Axial Point Load Strenght Test
2
2
0
Rock Testing

342

(IS 18764)
Brazilian Tensile Strength Test
-
0
0
0

S - denotes SPT sample


B - denotes bulk sample

(IS 10082)
D - denotes disturbed sample
7
5
2
X
X

Slake Durability (IS 10050)


342
4
4
0

Jar Slake Durability


342

Determination of Rock Hardness by


5
5
0

732

Rebound Hammer Method


8
1
1
0

pH (IS 3025:pt11)
8
0
0
0

Salinity (IS 3025:pt32)


8
0
0
0

Sulfates (SO4 2), mg/L (IS 3025:pt11)

Magnesium (Mg2+), mg/L (IS


8
0
0
0
Date submitted to lab

3025:pt46)
Date submitted to client :
:

8
0
0
0

Total Dissolved Salts (TDS)


Ground Water Testing

Electrical Conductivity, mS/m (IS


8
0
0
0

C - denotes core samples

3025:pt14)
W- denotes water sample
U - denotes undisturbed sample
Date submitted to client :
Date submitted to lab :

Schedule No: 01

Remarks/
Strata Description

Total
Previous
To date
BOQ quantities
W- denotes water sample
U - denotes undisturbed sample
C - denotes core samples

011E41FO-EN-004 | Rev 03 | 07 January 2020 011E41


Date submitted to client :
Date submitted to lab :

Schedule No: 01

Remarks/
Strata Description

Total
Previous
To date
BOQ quantities
W- denotes water sample
U - denotes undisturbed sample
C - denotes core samples

011E41FO-EN-004 | Rev 03 | 07 January 2020 011E41


Date submitted to client :
Date submitted to lab :

Schedule No: 01

Remarks/
Strata Description

Total
Previous
To date
BOQ quantities
W- denotes water sample
U - denotes undisturbed sample
C - denotes core samples

011E41FO-EN-004 | Rev 03 | 07 January 2020 011E41


P24-01-PD Borehole No.

Notes:
Issued by :

Checked by :
Sample Number

Sample Top Depth

0
0
Sample Bottom Depth
Project No. : PU-21-0059-MV

Sample Details

011E41FO-EN-004 | Rev 03 | 07 January 2020


Specimen depth

CU or CD Triaxial Compression with PP

-
0
0
0
measurement, single stage (IS 2720:pt12)

CU or CD Triaxial Compression with PP

-
0
0
0
measurement, 3 sample multi stage (IS
2720:pt12)
Cyclic Triaxial Test on soil sample
Compaction Test

-
0
0
0
Soil Strength Tests /

(ASTM D5311-13&
Project Title : Greater Male Connectivity Male to Thilafushi Link Project

ASTM D3999-11)

Triaxial Test on Rock Sample

0
0
0

342
(IS 13047)

Direct Shear Strength Test on Rock samples

-
0
0
0
along natural discontinuity single stage
(IS 12634)
Direct Shear Strength Test on Rock samples

-
0
0
0
along natural discontinuity (set of 3 samples at
Schedule of Laboratory Special Tests for Pre-Drill

different confining pressures) (IS 12634)

Lab Swelling Test on rock sample

0
0
0
Rock testing

342
Client

(IS 14396:pt1-4 & ISRM)

Cyclic Triaxial Test on rock sample

-
0
0
0
(ASTM D5311-13 & ASTM D3999-11)

-
0
0
0

011E41
Petrographic Testing (BS 12407)
Location : Male, Maldives

8
0
0
0
Calcium (Ca2), mg/L

S - denotes SPT sample


B - denotes bulk sample
D - denotes disturbed sample
8
0
0
0
Sodium (IS 3025:pt45)
: Afcons Infrastructure Limited

Alkalinity HCO3-, mg/L

8
0
0
0
HCO3- or mEq/L (IS 3025:pt23)

8
0
0
0
Total Hardness (IS 3025:pt21)

8
0
0
0
Aggressive CO2, mg/L

8
0
0
0
Ammonium (NH4), mg/L
Ground water Testing

8
0
0
0
Dissolved Oxygen
Date submitted to lab

8
0
0
0
Chloride (Cl-), mg/L (IS 3025:pt32)
:
Date submitted to client :

Electrical Conductivity, mS/m (IS

8
0
0
0

C - denotes core samples


3025:pt14)

W- denotes water sample


U - denotes undisturbed sample
Total

To date
Previous

BOQ quantities
Remarks/
Schedule No: 01

Strata Description
P24-01-PD Borehole No.

Notes:
Issued by :

Checked by :
Sample Number

Sample Top Depth

0
0
Sample Bottom Depth
Project No. : PU-21-0059-MV

Sample Details

011E41FO-EN-004 | Rev 03 | 07 January 2020


Specimen depth

CU or CD Triaxial Compression with PP

-
0
0
0
measurement, single stage (IS 2720:pt12)

CU or CD Triaxial Compression with PP

-
0
0
0
measurement, 3 sample multi stage (IS
2720:pt12)
Cyclic Triaxial Test on soil sample
Compaction Test

-
0
0
0
Soil Strength Tests /

(ASTM D5311-13&
Project Title : Greater Male Connectivity Male to Thilafushi Link Project

ASTM D3999-11)

Triaxial Test on Rock Sample

0
0
0

342
(IS 13047)

Direct Shear Strength Test on Rock samples

-
0
0
0
along natural discontinuity single stage
(IS 12634)
Direct Shear Strength Test on Rock samples
along natural discontinuity (set of 3

-
0
0
0
Schedule of Laboratory Special Tests for Pre-Drill

samples at different confining pressures) (IS


12634)
Lab Swelling Test on rock sample

0
0
0
Rock testing

342
Client

(IS 14396:pt1-4 & ISRM)

Cyclic Triaxial Test on rock sample

-
0
0
0
(ASTM D5311-13 & ASTM D3999-11)

-
0
0
0

011E41
Petrographic Testing (BS 12407)
Location : Male, Maldives

8
0
0
0
Calcium (Ca2), mg/L

S - denotes SPT sample


B - denotes bulk sample
D - denotes disturbed sample
8
0
0
0
Sodium (IS 3025:pt45)
: Afcons Infrastructure Limited

Alkalinity HCO3-, mg/L

8
0
0
0
HCO3- or mEq/L (IS 3025:pt23)

8
0
0
0
Total Hardness (IS 3025:pt21)

8
0
0
0
Aggressive CO2, mg/L

8
0
0
0
Ammonium (NH4), mg/L
Ground water Testing

8
0
0
0
Dissolved Oxygen
Date submitted to lab

8
0
0
0
Chloride (Cl-), mg/L (IS 3025:pt32)
:
Date submitted to client :

Electrical Conductivity, mS/m (IS

8
0
0
0

C - denotes core samples


3025:pt14)

W- denotes water sample


U - denotes undisturbed sample
Total

To date
Previous

BOQ quantities
Remarks/
Schedule No: 01

Strata Description