You are on page 1of 3

MGB MGB

9
A - ROW 1 - B A - ROW 2 - B A - ROW 3 - B A - ROW 4 - B A - ROW 5 - B A - ROW 6 - B
1000

600

1 2
150 PDB / FO.R 150 PDB / FO.R

ROUTER
EQPT
IDF

FDF
3

FIBERHOME

FIBERHOME
600

EQPT

EQPT

DWDM

DWDM
EQPT
NEC

NEC

RACK

RACK
NEC
600 600

FDF
4 600

FDF
5

DDN EQPT
FDF
10

FIBERHOME
300

FIBERHOME
600

FDF
EQPT
NEC

DWDM
DWDM

RACK
RACK
600 600
DDF

2400

FDB

HUAWEI
FDB

EQPT
600

HUAWEI
EQPT
600

SDH STM 16
FIBERHOME

FIBERHOME
600

DWDM
RACK
600 600

FDF

FDF
300

HUAWEI
EQPT
FIBERHOME
IBAS 180A 600

ALCATEL
U-NODE
6000

FDB

FDB

EQPT

EQPT
600 600 600

FDF
PDB / FO.R
600

FDF
6

HALON
GAS
7 8
2967

PWR B PWR A

Legend : 6 PROPOSED NEW BLOCK FOR CLIENT AT ROW 3B/R8/BLK 3 & 4

1 PROPOSED NEW DWDM RACK 1 PSS-32 AT ROW 4A/ R1A


TM JASIN 7 PROPOSED NEW DCPDB & BREAKER (100A X 1)(63A X 4) FOR POWER A
(2ND FLOOR) 2 PROPOSED NEW DWDM RACK 2 PSS-8 AT ROW 4B/R1B

8 PROPOSED NEW DCPDB & BREAKER (100A X 1)(63A X 4) FOR POWER B


3 RESERVED 1 PORT FOR LINE TO TGK AT ROW 3B/R1/BLK 3
9 RESERVED 2 PORT FOR GROUNDING AT EXISTING MGB

4 RESERVED 1 PORT FOR LINE TO AG AT ROW 3B/R2/BLK 4

10 RESERVED 1 PORT FOR LAN CABLE AT EXISTING ROUTER RACK


5 RESERVED 1 PORT FOR LINE TO ML AT ROW 3B/R3/BLK 2

STATION : TM JASIN PREPARED BY NORSYUHADA

PROJECT NAME : GALACTIC – 3C CHECKED BY

CONTENT : SITE SURVEY DRAWING SCALE : 3 cm : 500mm APPROVED BY


MGB MGB

9
A - ROW 1 - B A - ROW 2 - B A - ROW 3 - B A - ROW 4 - B A - ROW 5 - B A - ROW 6 - B

1 2
PDB / FO.R PDB / FO.R

ROUTER
EQPT
IDF

FDF
3

FIBERHOME

FIBERHOME
EQPT

EQPT

DWDM

DWDM
EQPT
NEC

NEC

RACK

RACK
NEC

FDF
4

FDF
5

DDN EQPT
FDF
10

FIBERHOME
FIBERHOME
FDF
EQPT
NEC

DWDM
DWDM

RACK
RACK
DDF

FDB

HUAWEI
FDB

EQPT
HUAWEI
EQPT
SDH STM 16
FIBERHOME

FIBERHOME
DWDM
RACK
FDF
FDF

HUAWEI
EQPT
FIBERHOME
IBAS 180A

ALCATEL
U-NODE
FDB
FDB

EQPT

EQPT
FDF
PDB / FO.R

FDF
6

HALON
GAS
7 8

PWR B PWR A

Legend : 6 PROPOSED NEW BLOCK FOR CLIENT AT ROW 3B/R8/BLK 3 & 4

1 PROPOSED NEW DWDM RACK 1 PSS-32 AT ROW 4A/ R1A


TM JASIN 7 PROPOSED NEW DCPDB & BREAKER (100A X 1)(63A X 4) FOR POWER A
(2ND FLOOR) 2 PROPOSED NEW DWDM RACK 2 PSS-8 AT ROW 4B/R1B

8 PROPOSED NEW DCPDB & BREAKER (100A X 1)(63A X 4) FOR POWER B


3 RESERVED 1 PORT FOR LINE TO TGK AT ROW 3B/R1/BLK 3
EXISTING CABLE RACK
9 RESERVED 2 PORT FOR GROUNDING AT EXISTING MGB

4 RESERVED 1 PORT FOR LINE TO AG AT ROW 3B/R2/BLK 4

10 RESERVED 1 PORT FOR LAN CABLE AT EXISTING ROUTER RACK


5 RESERVED 1 PORT FOR LINE TO ML AT ROW 3B/R3/BLK 2

STATION : TM JASIN PREPARED BY NORSYUHADA

PROJECT NAME : GALACTIC – 3C CHECKED BY

CONTENT : SITE SURVEY DRAWING SCALE : 3 cm : 500mm APPROVED BY


MGB MGB

9
A - ROW 1 - B A - ROW 2 - B A - ROW 3 - B A - ROW 4 - B A - ROW 5 - B A - ROW 6 - B

1 2
PDB / FO.R PDB / FO.R

ROUTER
EQPT
IDF

FDF
3

FIBERHOME

FIBERHOME
EQPT

EQPT

DWDM

DWDM
EQPT
NEC

NEC

RACK

RACK
NEC

FDF
4

FDF
5

DDN EQPT
FDF
10

FIBERHOME
FIBERHOME
FDF
EQPT
NEC

DWDM
DWDM

RACK
RACK
DDF

FDB

HUAWEI
FDB

EQPT
HUAWEI
EQPT
FIBERHOME
SDH STM 16

FIBERHOME
DWDM
RACK
FDF
FDF

HUAWEI
EQPT
FIBERHOME
IBAS 180A

ALCATEL
U-NODE
FDB
FDB

EQPT

EQPT
FDF
PDB / FO.R

FDF
6

HALON
GAS
7 8

PWR B PWR A

Legend : 6 PROPOSED NEW BLOCK FOR CLIENT AT ROW 3B/R8/BLK 3 & 4


CABLE POWER A &B
1 PROPOSED NEW DWDM RACK 1 PSS-32 AT ROW 4A/ R1A
TM JASIN 7 PROPOSED NEW DCPDB & BREAKER (100A X 1)(63A X 4) FOR POWER A
PATCH CORD / FIBER CABLE

(2ND FLOOR) 2 PROPOSED NEW DWDM RACK 2 PSS-8 AT ROW 4B/R1B


GROUNDING CABLE
ROUTER
8 PROPOSED NEW DCPDB & BREAKER (100A X 1)(63A X 4) FOR POWER B
3 RESERVED 1 PORT FOR LINE TO TGK AT ROW 3B/R1/BLK 3
9 RESERVED 2 PORT FOR GROUNDING AT EXISTING MGB

4 RESERVED 1 PORT FOR LINE TO AG AT ROW 3B/R2/BLK 4

10 RESERVED 1 PORT FOR LAN CABLE AT EXISTING ROUTER RACK


5 RESERVED 1 PORT FOR LINE TO ML AT ROW 3B/R3/BLK 2

STATION : TM JASIN PREPARED BY NORSYUHADA

PROJECT NAME : GALACTIC – 3C CHECKED BY

CONTENT : SITE SURVEY DRAWING SCALE : 3 cm : 500mm APPROVED BY

You might also like