Professional Documents
Culture Documents
3900 Series NodeB Product Description PDF
3900 Series NodeB Product Description PDF
Issue V4.0
Date 2011-02-10
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
1 Introduction.................................................................................................................................... 5
1.1 Product Positioning .......................................................................................................................................... 5
1.2 Product Features ............................................................................................................................................... 6
1 Introduction
2 System Architecture
2.2 BBU3900
2.2.1 Appearance of the BBU3900
The BBU3900 features a compact case structure that requires a 19-inch-wide and 2 U-high
space. It can be installed on a wall, on a staircase, in a storeroom, or in an outdoor cabinet in
the existing network. Figure 2-1 shows the BBU3900.
N x M = sector x carrier. For example, 3 x 1 indicates that each of the three sectors has one carrier.
USCU GPS antenna port 1 SMA connector Port for RF signal input from the satellite
card
RGPS port 2 PCB welded wiring Connecting to the RGPS signal cable
terminal
TOD port 2 RJ-45 connector Connecting to the TOD equipment
M-1PPS port 1 SMA connector Connecting to the Metro 1000 equipment
BITS port 1 SMA connector Connecting to the BITS clock
UTRP E1/T1 port 2 DB26 connector Providing eight ATM over E1s/T1s or eight
IP over E1s/T1s
Unchannelized 1 SFP connector Providing one unchannelized STM-1/OC-3
STM-1/OC-3 port port
FE/GE electrical 4 RJ-45 connector Providing four 10M/100M/1000M Ethernet
port electrical ports
The UEIU is a monitoring and dry contact extension board for the UPEU.
2.3 RRU
The RRU is the outdoor remote radio unit. The RRU is the RF module of the distributed
NodeB and is installed close to the antenna.
RRU3806 80 W 4
RRU3908 2×40W 4
2.4 WRFU
The WCDMA Radio Filter Unit (WRFU) is an indoor RF unit and is the RF module of the
macro NodeB.
Power supply socket 3V3 connector 1 Port for –48 V DC power input
Port for transceiving DIN female connector 2 Port for connecting the antenna system
antenna signals
2.5.1 APM30H
The advanced power module APM30H is an outdoor power backup system. The APM30H
provides –48 V DC power and backup power for distributed NodeBs, outdoor macro NodeBs,
and mini NodeBs. In addition, it provides installation space for the BBU3900 and customer
equipment.
The APM30H features a compact and lightweight design. It can be installed on a pole or on
the ground. Figure 2-4 shows the structure of the APM30H.
2.5.2 TMC11H
The TMC11H provides installation space for the BBU3900 and transmission equipment, thus
meeting the requirements of quick network construction. The TMC11H is applied to outdoor
scenarios with adverse environment. It features compact design and easy transport. Figure 2-5
shows the structure of the TMC11H.
(1) Fan (internal recycling) (2) CMUA (Central Monitoring Unit type A)
(3) PDU-03 (4) Door status sensor
(5) ELU (6) Fan (external recycling)
(7) Heat exchanger core (8) AC power distribution box
2.5.4 IBBS200D
The IBBS200D is a battery cabinet applied to outdoor scenarios. It features compact design
and easy transport. The IBBS200D can be configured with batteries of different capacity as
required, such as 48 V 92 Ah, and 48 V 184 Ah. Figure 2-7 shows the IBBS200D.
2.5.7 PS4890
The PS4890, an indoor power cabinet, provides DC power and power backup for the
distributed NodeBs or BTS3900s. The PS4890 also provides installation space for the
BBU3900 and transmission equipment.
The PS4890 features compact design and light weight. It can be installed on a pole or on the
ground. In addition, the PS4890 houses the batteries. Figure 2-10 shows the structure of the
PS4890.
2.5.8 OMB
The OMB provides functions such as power distribution and surge protection for the
BBU3900. When the BBU3900 is installed in an outdoor mini cabinet, it works as a
component of the compact mini NodeB in outdoor application.
The OMB has a built-in heat exchanger. If the AC power is used, the cabinet must be
configured with an EPS30-4815A and an SPD (AC); if the DC power is used, the cabinet
must be configured with a DC power distribution box. Figure 2-11 shows the internal
structure of the outdoor mini NodeB in different power configurations.
2.5.9 SLPU
The SLPU provides the signal surge protection for the NodeB. Figure 2-12 shows the SLPU.
3 Application Scenarios
3.1 Overview
Huawei 3900 series NodeB products can be configured in different ways. Therefore, these
products can be deployed in different application scenarios, thus providing a perfect
whole-network solution for operators. The Huawei 3900 series NodeBs consist of the indoor
macro NodeB (BTS3900 and BTS3900L), outdoor macro NodeB (BTS3900A), distributed
NodeB (DBS3900), and mini NodeB (BTS3900C).
The application scenarios are as follows:
The BTS3900 and BTS3900L are mainly applicable to indoor installation scenarios
where traffic is heavy, equipment room rental is high, and space is limited.
The BTS3900A is mainly applicable to outdoor scenarios where large-capacity coverage
is required in urban, suburban, and rural areas.
The DBS3900 is mainly applicable to outdoor application scenarios where wide
coverage is required and site construction is difficult.
The BTS3900C is mainly applicable to outdoor coverage and hot-spot coverage.
4 Technical Specifications
Item Specification
Capacity 24 cells
Maximum configuration: 6 x 4, 3 x 8
Uplink: 1536 CEs
Downlink: 1536 CEs
Output power 80 W WRFU The WRFU supports four carriers, and its output power at the antenna
port reaches 80 W.
The carrier supports a maximum of 60 W in case of 1-carrier
configuration.
Each carrier supports a maximum of 40 W in case of 2-carrier
configuration. *
Each carrier a maximum of 20 W in case of 3-carrier or 4-carrier
configuration.
Uneven power configuration is supported.
40 W WRFU The WRFU supports two carriers, and its output power at the antenna
port reaches 40 W.
Item Specification
–126.5** –129.3** –132.0**
850 MHz*** –125.6* –128.4* –131.1*
–126.3** –129.1** –131.8**
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
***: Measurement value of the sub-band at 850 MHz.
Transmission port Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock, OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions BTS3900 without the base: 900 mm x 600 mm x 450 mm
(height x width x Base: 40 mm x 600 mm x 420 mm
depth)
Weight Empty cabinet: ≤ 70 kg
BTS3900 in 3 x 1 configuration: ≤ 120 kg
BTS3900 in full configuration: ≤ 160 kg
Input power –48 V DC, permissible voltage range: –38.4 V DC to –57 V DC
+24 V DC, permissible voltage range: +21.6 V DC to +29 V DC
220 V AC single-phase, rated voltage range: 220 V AC to 240 V AC; permissible voltage
range: 176 V AC to 290 V AC
220 V AC three-phase, rated voltage range: 220/346 V AC to 240/415 V AC; permissible
voltage range: 176/304 V AC to 290/500 V AC
110 V AC dual-live-wire power cable:
− Rated voltage: 100/200 V AC to 120/240 V AC; permissible voltage range: 90/180 V
AC to 135/270 V AC
− Rated voltage: 120/208 V AC to 127/220 V AC; permissible voltage range: 105/176 V
AC to 150/260 V AC
Power Power consumption (W) Power backup duration based on
consumption new batteries and typical power
consumption (hour)
Configuration Typical power Maximum power 92 Ah 184Ah
consumption consumption
3×1 410 520 10.8 21.5
3×2 470 670 9.2 18.8
3×3 610 830 6.9 14.5
Item Specification
3×4 760 1110 5.1 11.62
The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900 works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier
is 20 W and the BTS3900 works with a 100% load at 25°C ambient temperature.
Power consumption in the table above is determined on the basis of a NodeB configured with the
WBBPb.
Item Specification
40 W WRFU The WRFU supports two carriers, and its output power at the antenna
port reaches 40 W.
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
***: Measurement value of the sub-band at 850 MHz.
Item Specification
Transmission port Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock, OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions BTS3900L without the base: 1600 mm x 600 mm x 450 mm
(height x width x Base: 40 mm x 600 mm x 450 mm
depth)
Weight Empty cabinet: ≤ 75 kg
Cabinet in 3 x 1 configuration: ≤ 140 kg
Cabinet in full configuration: ≤ 235 kg
Input power –48 V DC, permissible voltage range: –38.4 V DC to –57 V DC
Power Configuration Typical power consumption (W) Maximum power consumption (W)
consumption
3×1 430 570
3×2 500 720
3×3 640 880
3×4 790 1170
The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900L works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier
is 20 W and the BTS3900L works with a 100% load at 25°C ambient temperature.
Power consumption in the table above is determined on the basis of a NodeB configured with the
WBBPb.
Item Specification
EMC The BTS3900 meets the Electromagnetic compatibility (EMC) requirements and complies
with the following standards:
CISPR 22 (1997)
EN 55022 (1998)
EN 301 489-23 V1.2.1 (2002-11)
CISPR 24 (1998)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-29
ETSI 301 489-1 V1.3.1 (2001-09)
FCC Part 15
The BTS3900L is CE certified.
Item Specification
Band Frequency band RX Band (MHz) TX Band (MHz)
2100 MHz 1920 to 1980 2110 to 2170
850 MHz 824 to 835 869 to 880
Capacity 24 cells
Maximum configuration: 6 x 4, 3 x 8
Uplink: 1536 CEs
Downlink: 1536 CEs
Item Specification
O WRFU
80 W The WRFU supports four carriers, and its output power at the antenna
u port reaches 80 W.
t The carrier a maximum of 60 W in case of 1-carrier configuration.
p
Each carrier supports a maximum of 40 W in case of 2-carrier
u
t configuration. *
Each carrier a maximum of 20 W in case of 3-carrier or 4-carrier
p configuration.
o Uneven power configuration is supported.
w
e
Maximum output power = Maximum output power of the PA - Internal losses.
r
The maximum output power is measured at the antenna port of the RF module.
* indicates the maximum output power in the typical configuration.
40 W WRFU The WRFU supports two carriers, and its output power at the antenna
port reaches 40 W.
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
***: Measurement value of the sub-band at 850 MHz.
Transmission port Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock, OCXO free-run clock, IP clock, and
synchronization BITS clock
Accuracy: 0.05 ppm
Dimensions RF cabinet/APM30H/TMC/BBC:
(height x width x Without the base: 700 mm x 600 mm x 480 mm
depth)
Base: 200 mm x 600 mm x 480 mm
Item Specification
Weight RF cabinet: ≤ 55 kg
APM30H cabinet: ≤ 65 kg
BTS3900A in typical 3 x 1 configuration: ≤ 165 kg (without batteries)
BTS3900A in full configuration: ≤ 210 kg (RF cabinet with 6 RFUs and without
batteries)
Input power –48 V DC, permissible voltage range: –38.4 V DC to –57 V DC
220 V AC single-phase: rated voltage: 220 V AC to 240 V AC; permissible voltage
range: 176 V AC to 290 V AC
220V AC three-phase: rated voltage: 220/346 V AC to 240/415 V AC; permissible
voltage range: 176/304 V AC to 290/500 V AC
110 V AC dual-live-wire power cable:
− Rated voltage: 100/200 V AC to 120/240 V AC; permissible voltage range: 90/180 V
AC to 135/270 V AC
− Rated voltage: 120/208 V AC to 127/220 V AC; permissible voltage range: 105/176
V AC to 150/260 V AC
Power Power consumption (W) Power backup duration based on the
consumption battery capacity and typical power
consumption (hour)
Configuration Typical Maximum 92 Ah 184 Ah
power power
consumption consumption
3×1 455 525 9.5 19.4
3×2 525 690 8.2 16.8
3×3 680 870 6.0 13.0
3×4 845 1180 4.5 10.5
The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900A works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier
is 20 W and the BTS3900A works with a 100% load at 25°C ambient temperature.
Power consumption in the table above is determined on the basis of a NodeB configured with the
WBBPb.
Item Specification
Transportation ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation"
Anti-seismic IEC 60068-2-57 (1999-11) Environmental testing - Part 2-57: Tests – Test Ff: Vibration –
performance Time-history method.
EMC The BTS3900A meets the EMC requirements and complies with the following standards:
CISPR 22 (1997)
EN 55022 (1998)
EN 301 489-23 V1.2.1 (2002-11)
CISPR 24 (1998)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-29
ETSI 301 489-1 V1.3.1 (2001-09)
FCC Part 15
The BTS3900A is CE certified.
Item Specification
Band DC RRU3804 Frequency RX band (MHz) TX band (MHz)
band
2100 MHz 1920 to 1980 2110 to 2170
1900 MHz 1850 to 1910 1930 to 1990
AWS 1710 to 1755 2110 to 2155
850 MHz 824 to 849 869 to 894
AC RRU3804 Frequency RX band (MHz) TX band (MHz)
band
2100 MHz 1920 to 1980 2110 to 2170
Item Specification
Capacity 24 cells
Maximum configuration: 6 x 4, 3 x 8
Uplink: 1536 CEs
Downlink: 1536 CEs
Output power A single RRU3804 supports up to four carriers with a 60 W output power at the antenna
port with four carriers.
One-carrier configuration: maximum output power of 60 W per carrier
Two-carrier configuration: maximum output power of 30 W per carrier
Three-carrier configuration: maximum output power of 20 W per carrier
Four-carrier configuration: maximum output power of 15 W per carrier
Supporting differentiated power configured for different carriers
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output
power is measured at the antenna port of the RF module.
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the
antenna port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is
within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that
the AMR service at 12.2 kbit/s is used and the BER is within 0.001.
***: Measurement value of the sub-band at 850 MHz.
Transmission port Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Item Specification
Dimensions BBU3900: 86 mm x 442 mm x 310 mm
(height x width x DC RRU3804
depth)
− 480 mm x 270 mm x 140 mm (without housing and connectors)
− 485 mm x 285 mm x 170 mm (with housing)
AC RRU3804
− 480 mm x 270 mm x 220 mm (without housing and connectors)
− 485 mm x 285 mm x 250 mm (with housing)
Weight BBU3900
− In full configuration: 11 kg
− In typical configuration (1 PSU, 1 WBBP, 1 WMPT): 7 kg
DC RRU3804
− Without housing: 15 kg
− With housing: 17 kg
AC RRU3804
− Without housing: 20.5 kg
− With housing: 22.5 kg
Input voltage BBU3900:
− +24V DC, voltage range: +21.6 V DC to +29 V DC
− -48V DC, voltage range: –38.4 V DC to –57 V DC
RRU3804
− –48 V DC, voltage range: –36 V DC to –57 V DC
− 200 V AC to 240 V AC single phase, voltage range: 176 V AC to 290 V AC
− 100/200 V AC to 120/240 V AC two phases, voltage range: 90/180 V AC to 135/270
V AC
Power DC RRU3804 Power consumption (W) Power backup duration based on
consumption the battery capacity and typical
power consumption (hour)
Configuration Typical power Maximum 24 Ah 92 Ah
consumption power
(40% load) consumption
(100% load)
3×1 390 480 2.4 11.3
3×2 480 650 1.7 9.0
3×3 630 860 1.2 6.7
3×4 630 860 1.2 6.7
AC RRU3804 Power consumption (W) Power backup duration based on
the battery capacity and typical
power consumption (hour)
Item Specification
Configuration Typical power Maximum 24 Ah 92 Ah
consumption power
(40% load) consumption
(100% load)
3×1 435 540 2.0 10.1
3×2 555 740 1.5 7.8
3×3 720 980 1.0 5.6
3×4 720 980 1.0 5.6
NOTE
The typical power consumption is reached when the output power at the antenna port per carrier is
20 W and the DBS3900 works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier
is 20 W and the DBS3900 works with a 100% load at 25°C ambient temperature.
In 3 x4 configurations, the typical and maximum power consumption are reached when the output
power per carrier at the antenna port is 15 W
Item Specification
EMC The NodeB meets the EMC requirements and complies with the following standards:
CISPR 22 (1997)
EN 55022 (1998)
EN 301 489-23 V1.2.1 (2002-11)
CISPR 24 (1998)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-29
ETSI 301 489-1 V1.3.1 (2001-09)
FCC Part 15
The DBS3900 is CE certified.
Item Specification
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power
is measured at the antenna port of the RF module.
Item Specification
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE optical
port
Clock Clock on the Iub interface, GPS clock, OCXO free-run clock, IP clock, BITS clock
synchronization Accuracy: 0.05 ppm
Dimensions BBU3900: 86 mm x 442 mm x 310 mm
(height x width DC RRU3801E:
x depth)
− 480 mm x 270 mm x 140 mm (without housing and connectors)
− 485 mm x 285 mm x 170 mm (with housing)
Weight BBU3900
− In full configuration: 11 kg
− In typical configuration (1 PSU, 1 WBBP, and 1 WMPT): 7 kg
DC RRU3801E
− Without housing: 15 kg
− With housing: 17 kg
Input power BBU3900
− +24 V DC, voltage range: +21.6 V DC to +29 V DC
− –48 V DC, voltage range: –38.4 V DC to –57 V DC
RRU3801E
− –48 V DC, voltage range: –36 V DC to –57 V DC
Power Power consumption (W) Power backup duration based on the
consumption battery capacity and typical power
consumption (hour)
Configuration Typical power Maximum 24 Ah 92 Ah
consumption power
(40% load) consumption
(100% load)
3×1 390 480 2.4 11.3
3×2 480 650 1.7 9.0
The typical power consumption is reached when the output power at the antenna port per carrier is 20 W
and the DBS3900 works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the DBS3900 works with a 100% load at 25°C ambient temperature.
Item Specification
Temperature BBU3900: –20°C to +55°C
RRU3801E:
− –40°C to +50°C (with 1120 W/m2 solar radiation)
− –40°C to +55°C (without solar radiation)
Relative BBU3900: 5% RH to 95% RH
humidity RRU3801E: 5% RH to 100% RH
Absolute BBU3900: 1–25 g/m3
humidity RRU3801E: 1–30 g/m3
Air pressure 70 kPa to 106 kPa
IP rating BBU3900: IP20
DC RRU3801E: IP65
Storage ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weather protected, not
temperature-controlled storage locations"
Transportation ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation"
Anti-seismic IEC 60068-2-57 (1999-11) Environmental testing – Part 2-57: Tests – Test Ff: Vibration –
performance Time-history method.
EMC The DBS3900 meets the EMC requirements and complies with the following standards:
CISPR 22 (1997)
EN 55022 (1998)
EN 301 489-23 V1.2.1 (2002-11)
CISPR 24 (1998)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-29
ETSI 301 489-1 V1.3.1 (2001-09)
FCC Part 15
The DBS3900 is CE certified.
Item Specification
Item Specification
1900 MHz 1850 to 1910 1930 to 1990
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power
is measured at the antenna port of the RF module.
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock on the Iub interface, GPS clock, OCXO free-run clock, IP clock, and BITS clock
synchronization Accuracy: 0.05 ppm
Dimensions BBU3900: 86 mm x 442 mm x 310 mm
(height x width RRU3801C
x depth)
− 480 mm x 365 mm x 145 mm (without rack and housing)
− 610 mm x 380 mm x 200 mm (with rack and housing)
Item Specification
Weight BBU3900
− In full configuration: 11 kg
− In typical configuration (1 PSU, 1 WBBP, and 1 WMPT): 7 kg
RRU3801C
− Without housing: 20 kg
− With housing: 22 kg
Input power BBU3900
− +24 V DC, voltage range: +21.6 V DC to +29 V DC
− –48 V DC, voltage range: –38.4 V DC to –57 V DC
RRU3801C
− –48 V DC, voltage range: –40 V DC to –60 V DC
− 200 V AC to 240 V AC single phase, voltage range: 150 V AC to 300 V AC
Power Power consumption (W) Power backup duration based on the
consumption battery capacity and typical power
consumption (hour)
Configuration Typical power Maximum 24 Ah 92 Ah
consumption power
(50% load) consumption
(100% load)
3x1 540 620 1.5 8.0
3x2 680 830 1.1 5.9
The typical power consumption is reached when the output power at the antenna port per carrier is 20 W
and the DBS3900 works with a 50% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the DBS3900 works with a 100% load at 25°C ambient temperature.
Item Specification
Transportation ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation"
Anti-seismic IEC 60068-2-57 (1999-11) Environmental testing – Part 2-57: Tests – Test Ff: Vibration –
performance Time-history method.
EMC The DBS3900 meets the EMC requirements and complies with the following standards:
CISPR 22 (1997)
EN 55022 (1998)
EN 301 489-23 V1.2.1 (2002-11)
CISPR 24 (1998)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-29
ETSI 301 489-1 V1.3.1 (2001-09)
FCC Part 15
The DBS3900 is CE certified.
Item Specification
Band Frequency band RX band (MHz) TX band (MHz)
2100 MHz 1920 to 1980 2110 to 2170
AWS 1710~1755 2110~2155
Capacity 24 cells
Maximum configuration in the case of one TX channel and two RX channels: 6 x 2, 3 x 8
Maximum configuration in the case of MIMO: 6 x 2, 3 x 4
Uplink: 1536 CEs
Downlink: 1536 CEs
Item Specification
Output power One RRU3808 supports four carriers with 2*40 W output power at the antenna port of the
RF module.
The RRU3808 supports one TX channel, MIMO, and combination of one TX channel and
MIMO.
− One TX channel: maximum output power of a TX channel reaching 40 W
− MIMO: maximum output power reaching 40 W + 40 W
− Combination of one TX channel and MIMO: maximum output power of a TX channel
reaching 40 W
The RRU3808 supports differentiated power configured for each carrier.
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power
is measured at the antenna port of the RF module.
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock on the Iub interface, GPS clock, OCXO free-run clock, IP clock, and BITS clock
synchronization Accuracy: 0.05 ppm
Dimensions BBU3900: 86 mm x 442 mm x 310 mm
(height x width RRU3808
x depth)
− 480 mm x 270 mm x 140 mm (without connectors and housing)
− 485 mm x 285 mm x 170 mm (with connectors)
Weight BBU3900
− In full configuration: 11 kg
− In typical configuration (1 PSU, 1 WBBP, and 1 WMPT): 7 kg
RRU3808
− Without housing: 17 kg
− With housing: 19 kg
Item Specification
Input power BBU3900
− +24 V DC, voltage range: +21.6 V DC to +29 V DC
− –48 V DC, voltage range: –38.4 V DC to –57 V DC
RRU3808
− –48 V DC, voltage range: –36 V DC to –57 V DC
Power Power consumption in MIMO configuration (W) Power backup duration based on the
consumption battery capacity and typical power
consumption (hour)
Configuration Typical Maximum 92 Ah
power power
consumption consumption
(40% load) (100% load)
The typical power consumption is reached when the output power at the antenna port per carrier is 10
W + 10 W and the DBS3900 works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier is
10 W + 10 W and the DBS3900 works with a 100% load at 25°C ambient temperature.
The typical power consumption is reached when the output power at the antenna port per carrier is 20 W
and the DBS3900 works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the DBS3900 works with a 100% load at 25°C ambient temperature.
Item Specification
Temperature BBU3900: –20°C to +55°C
RRU3808
− –40°C to +50°C (with 1120 W/m2 solar radiation)
− –40°C to +55°C (without solar radiation)
Relative BBU3900: 5% RH to 95% RH
humidity RRU3808: 5% RH to 100% RH
Absolute BBU3900: 1–25 g/m3
humidity RRU3808: 1–30 g/m3
Air pressure 70 kPa to 106 kPa
IP rating BBU3900: IP20
RRU3808: IP65
Storage ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weather protected, not
temperature-controlled storage locations"
Transportation ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation"
Anti-seismic IEC 60068-2-57 (1999-11) Environmental testing – Part 2-57: Tests – Test Ff: Vibration –
performance Time-history method.
EMC The DBS3900 meets the EMC requirements and complies with the following standards:
CISPR 22 (1997)
EN 55022 (1998)
EN 301 489-23 V1.2.1 (2002-11)
CISPR 24 (1998)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-29
ETSI 301 489-1 V1.3.1 (2001-09)
FCC Part 15
The DBS3900 is CE certified.
Item Specification
Band Frequency band RX band (MHz) TX band (MHz)
2100MHz 1920 to 1980 2110 to 2170
Capacity 24 cells
Maximum configuration:6 x 4, 3 x 8
Uplink: 1,536 CEs
Downlink:1,536 CEs
Output power The RRU3806 supports four carriers, and its output power at the antenna connector
reaches 80 W.
The carrier a maximum of 80 W in case of 1-carrier configuration.
Each carrier a maximum of 40 W in case of 2-carrier configuration.
Each carrier a maximum of 26 W in case of 3-carrier configuration.
Each carrier a maximum of 20 W in case of 4-carrier configuration.
Uneven power configuration is supported.
Maximum output power = Maximum output power of the PA - Internal losses. The maximum
output power is measured at the antenna port of the RF module.
Receiver sensitivity Frequency band 1-way receiver 2-way receiver 4-way receiver
sensitivity (dBm) sensitivity (dBm) sensitivity
(dBm)
2100 MHz –125.8* –128.6* –131.3*
–126.5** –129.3** –132.0**
The receiver sensitivity is measured, as recommended in 3GPP TS 25.104, over the full band
at the antenna connector provided that the channel rate reaches 12.2 kbit/s and the Bit Error
Rate (BER) does not exceed 0.001.
The receiver sensitivity is measured on the center frequency at the antenna connector provided
that 12.2 kbit/s Adaptive Multi Rate (AMR) service is in progress and the BER does not
exceed 0.001.
Transmission port Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
Optional hardware units provide unchannelized STM-1 port, GE electrical port, and
GE optical port
Clock synchronization Line clock extracted from the Iub interface, GPS clock, BITS clock, clock of the
OCXO in free-run mode, and IP clock
Precision:0.05 ppm
Dimensions (height x BBU3900:86 mm x 442 mm x 310 mm
width x depth) RRU3806:
480 mm x 270 mm x 140 mm (without housing and connectors)
485 mm x 285 mm x 170 mm (with housing)
Weight BBU3900
− In full configuration: 11 kg
− In typical configuration (1 PSU, 1 WBBP, and 1 WMPT): 7 kg
RRU3806
− Without housing: 15 kg
− With housing: 17 kg
The typical power consumption is reached when the output power at the antenna port per
carrier is 20 W and the equipment works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power each carrier at the
antenna port is 20 W, the equipment works with 100% load, and the ambient temperature is
25°C.
Anti-seismic IEC 60068-2-57 (1999-11) Environmental testing – Part 2-57: Tests – Test Ff:
performance Vibration – Time-history method.
YD5083-99:Interim Provisions for Test of Anti-seismic Performances of
Telecommunications Equipment (telecom industry standard in People's Republic of
China)
EMC The DBS3900 (BBU3900+RRU3806) meets the EMC requirements and complies
with the following standards:
CISPR 22 (1997)
EN 55022 (1998)
EN 301 489-23 V1.2.1 (2002-11)
CISPR 24 (1998)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-29
GB 9254-1998
ETSI 301 489-1 V1.3.1 (2001-09)
FCC Part 15
The DBS3900 is CE certified.
Item Specification
Item Specification
Output power One RRU3908 supports four carriers with 2*40 W output power at the antenna port of the
RF module.
The RRU3908 supports one TX channel, MIMO, and combination of one TX channel and
MIMO.
One TX channel: maximum output power of a TX channel reaching 40 W
MIMO: maximum output power reaching 40 W + 40 W
Combination of one TX channel and MIMO: maximum output power of a TX channel
reaching 40 W
The RRU3908 supports differentiated power configured for each carrier.
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power
is measured at the antenna port of the RF module.
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock on the Iub interface, GPS clock, OCXO free-run clock, IP clock, and BITS clock
synchronizatio Accuracy: 0.05 ppm
n
Dimensions BBU3900: 86 mm x 442 mm x 310 mm
(height x width RRU3908
x depth)
− 485mm x 380 mm x 170 mm (without connectors and housing)
− 480 mm x 356 mm x 140 mm (with connectors)
Weight BBU3900
− In full configuration: 11 kg
− In typical configuration (1 PSU, 1 WBBP, and 1 WMPT): 7 kg
RRU3908
− Without housing: 21 kg
− With housing: 23 kg
Item Specification
Input power BBU3900
− +24 V DC, voltage range: +21.6 V DC to +29 V DC
− –48 V DC, voltage range: –38.4 V DC to –57 V DC
RRU3908
− –48 V DC, voltage range: –36 V DC to –57 V DC
Power Power consumption in MIMO configuration (W) Power backup duration based on the
consumption battery capacity and typical power
consumption (hour)
Configuration Typical Maximum 92 Ah
power power
consumption consumption
(40% load) (100% load)
The typical power consumption is reached when the output power at the antenna port per carrier is 20 W
and the DBS3900 works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the DBS3900 works with a 100% load at 25°C ambient temperature.
The typical power consumption is reached when the output power at the antenna port per carrier is 20 W
and the DBS3900 works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier is 20 W
and the DBS3900 works with a 100% load at 25°C ambient temperature.
Item Specification
Temperature BBU3900: –20°C to +55°C
RRU3908
− –40°C to +50°C (with 1120 W/m2 solar radiation)
− –40°C to +55°C (without solar radiation)
Relative BBU3900: 5% RH to 95% RH
humidity RRU3908: 5% RH to 100% RH
Absolute BBU3900: 1–25 g/m3
humidity RRU3808: 1–30 g/m3
Air pressure 70 kPa to 106 kPa
IP rating BBU3900: IP20
RRU3908: IP65
Storage ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weather protected, not
temperature-controlled storage locations"
Transportation ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation"
Anti-seismic IEC 60068-2-57 (1999-11) Environmental testing – Part 2-57: Tests – Test Ff: Vibration –
performance Time-history method.
YD5083-99:Interim Provisions for Test of Anti-seismic Performances of
Telecommunications Equipment (telecom industry standard in People's Republic of China)
EMC The DBS3900 meets the EMC requirements and complies with the following standards:
CISPR 22 (1997)
EN 55022 (1998)
EN 301 489-23 V1.2.1 (2002-11)
CISPR 24 (1998)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-29
GB 9254-1998
ETSI 301 489-1 V1.3.1 (2001-09)
FCC Part 15
The DBS3900 is CE certified.
Item Specification
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output
power is measured at the antenna port of the RF module.
* refers to the maximum output power in typical configurations.
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
***: Measurement value of the sub-band at 850 MHz.
Item Specification
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions BTS3900C: 600 mm x 400 mm x 390 mm
(height x width x OMB: 600 mm x 240 mm x 390 mm
depth)
Weight AC BTS3900C: ≤ 50 kg
DC BTS3900C: ≤ 48 kg
Input voltage –48 V DC, voltage range: –38.4 V DC to –57 V DC
200 V AC to 240 V AC single phase, voltage range: 176 V AC to 290 V AC
100/200 V AC to 120/240 V AC dual-live-wire power cable; voltage range: 90/180 V AC
to 135/270 V AC
Power Configuration Typical power Maximum power consumption
consumption consumption
The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900C works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the BTS3900C works with a 100% load at 25°C ambient temperature.
Item Specification
EMC The BTS3900C meets the EMC requirements and complies with the following standards:
CISPR 22 (1997)
EN 55022 (1998)
EN 301 489-23 V1.2.1 (2002-11)
CISPR 24 (1998)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-29
ETSI 301 489-1 V1.3.1 (2001-09)
FCC Part 15
The BTS3900C is CE certified.
Item Specification
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output
power is measured at the antenna port of the RF module.
* refers to the maximum output power in typical configurations.
Item Specification
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
***: Measurement value of the sub-band at 850 MHz.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions BTS3900C: 600 mm x 400 mm x 390 mm
(height x width x OMB: 600 mm x 240 mm x 390 mm
depth)
Weight AC BTS3900C: ≤ 50 kg
DC BTS3900C: ≤ 48 kg
Input voltage –48 V DC, voltage range: –38.4 V DC to –57 V DC
200 V AC to 240 V AC single phase, voltage range: 176 V AC to 290 V AC
100/200 V AC to 120/240 V AC dual-live-wire power cable; voltage range: 90/180 V AC
to 135/270 V AC
Power Configuration Typical power consumption Maximum power
consumption consumption
The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900C works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the BTS3900C works with a 100% load at 25°C ambient temperature.
Item Specification
Storage ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weather protected, not
temperature-controlled storage locations".
Transportation ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation"
Anti-seismic IEC 60068-2-57 (1999-11) Environmental testing – Part 2-57: Tests – Test Ff: Vibration –
performance Time-history method.
EMC The BTS3900C meets the EMC requirements and complies with the following standards:
CISPR 22 (1997)
EN 55022 (1998)
EN 301 489-23 V1.2.1 (2002-11)
CISPR 24 (1998)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-29
ETSI 301 489-1 V1.3.1 (2001-09)
FCC Part 15
The BTS3900C is CE certified.
Item Specification
Band Frequency band RX band (MHz) TX band (MHz)
2100 MHz 1920 to 1980 2110 to 2170
1900 MHz 1850 to 1910 1930 to 1990
1800 MHz 1710 to 1785 1805 to 1880
AWS 1710 to 1755 2110 to 2155
850 MHz 824 to 834 869 to 879
850 MHz 839 to 849 884 to 894
900 MHz 880 to 915 925 to 960
Capacity Two cells
Maximum configuration: 1 x 2
Uplink: 384 CEs
Downlink: 384 CEs
Item Specification
Output power The RRU3801C supports two carriers with a 40 W output power at the antenna port.
One-carrier configuration: maximum output power of 40 W per carrier
Two-carrier configuration: maximum output power of 20 W per carrier
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power
is measured at the antenna port of the RF module.
*: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
**: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions BTS3900C: 600 mm x 400 mm x 390 mm
(height x width x OMB: 600 mm x 240 mm x 390 mm
depth)
Weight AC BTS3900C: ≤ 55 kg
DC BTS3900C: ≤ 53 kg
Input voltage –48 V DC, voltage range: –38.4 V DC to –57 V DC
200 V AC to 240 V AC single phase, voltage range: 176 V AC to 290 V AC
100/200 V AC to 120/240 V AC dual-live-wire power cable; voltage range: 90/180 V AC
to 135/270 V AC
Power Configuration Typical power Maximum power consumption
consumption consumption
1x1 280 W 300 W
1x2 320 W 370 W
Item Specification
The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900C works with a 50% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the BTS3900C works with a 100% load at 25°C ambient temperature.
Item Specification
Band Frequency band RX Band (MHz) TX Band (MHz)
2100 MHz 1920 to 1980 2110 to 2170
Item Specification
Capacity 3 cells
Maximum configuration:1 x 3
Uplink: 384 CEs
Downlink:384 CEs
Output power The RRU3806 supports four carriers, and its output power at the antenna connector reaches
80 W.
The carrier a maximum of 80 W in case of 1-carrier configuration.
Each carrier a maximum of 40 W in case of 2-carrier configuration.
Each carrier a maximum of 26 W in case of 3-carrier configuration.
Each carrier a maximum of 20 W in case of 4-carrier configuration.
Uneven power configuration is supported.
Maximum output power = Maximum output power of the PA - Internal losses. The maximum output
power is measured at the antenna port of the RF module.
The receiver sensitivity is measured, as recommended in 3GPP TS 25.104, over the full band at the
antenna connector provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) does
not exceed 0.001.
The receiver sensitivity is measured on the center frequency at the antenna connector provided that
12.2 kbit/s Adaptive Multi Rate (AMR) service is in progress and the BER does not exceed 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Line clock extracted from the Iub interface, GPS clock, BITS clock, clock of the OCXO in
synchronization free-run mode, and IP clock
Precision:0.05 ppm
Dimensions 600 mm x 400 mm x 390 mm
(height x width x OMB: 600 mm x 240 mm x 390 mm
depth)
Weight AC BTS3900C: ≤ 50 kg
DC BTS3900C: ≤ 48 kg
Input voltage –48 V DC, voltage range: –38.4 V DC to –57 V DC
200 V AC to 240 V AC single-phase power cable, voltage range: 176 V AC to 290 V AC
100/200 V AC to 120/240 V AC dual live line power cable, voltage range: 90/180 V AC to
135/270 V AC
Power Configuration Typical power consumption Maximum power consumption
Item Specification
consumption 1×1 190 240
1×2 220 290
1×3 260 350
The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the equipment works with a 40% load at 25°C ambient temperature.
The maximum power consumption is reached when the output power each carrier at the antenna port
is 20 W, the equipment works with 100% load, and the ambient temperature is 25°C.