CLIENT:

N.H.A.
NATIONAL HIGHW AY AUTHOR ITY
27 Mauve Area Kashmir Hwy,
Islam abad

CONCESSIONA IRE:

LSMIM
LA HORE-SIA LKOT
MOTORWA Y
INFRA STRUCTURE
MANA GEM ENT (Pvt. Ltd)

INDEPENDENT ENGINEER:

300 SHOULDER
SBP
(NOTE-7)
VARIES
E.P.C. EXECUTING A GENC Y:
1 ROUNDING VARIES (4000 min.)
SHOULDER
1000
F.W.O.
Front ier Works Organ izat ion
(Headquarter 509, Kash mir Road ,
STUBS AT 10m INTERVALS AND DRY RIPRAP (CLASS "B) R.A. Bazar Rawalp indi.
AT THE ENDS OF PROTECTION
NSL OR AS DIRECTED BY E.P.C. CONSULTA NT :
THE ENGINEER
(SEE NOTE-4) Riprap stone of variable size as per adjustment DIRECTORATE OF DESIGN
PLACE RIPRAP AGAINST 1 & CONSULTANCY
UNDISTURBED MATERIAL FRONT OFFICE (M.C.E.)
3 (SEE NOTE-4)
500 NISAR ROAD,
1 RISALPUR CANTONMENT

1
PROJECT
GROUTED STONE RIPRAP PROTECTION DRY RIPRAP PROTECTION
(EP-1) (EP-2) LAHORE-SIALKOT MOTORWAY
(B.O.T.)

REV. REVISION/ ISSUE DATE

SHOULDER PAVEMENT
SBP
(NOTE-7)

2
1 GABION MATTRESS
EMBANKMENT FILL
50x50x6 STEEL ANGLE STAKES
2000 LONG AT 2000 c/c IN BOTH
GRANULAR PALTFORM DIRECTIONS (SEE NOTE-3)
NSL NSL
2
(SEE NOTE-5)
1 150 THICK GRAVEL
2000
AND SAND FILTER LAYER
500

GRANULAR PLATFORM EARTHEN DOWEL GABION MATTRESS PROTECTION


(EP-4) (EP-3)

DRAW ING TITLE:

LIMITS OF PROTECTION (SEE NOTE - 4)


CONCRETE CHUTE
PROTECTION
10000(max) 10000(max) WORK DETAIL
SPACING SPACING EMBANKMENT FILL
INTERMEDIATE DESIGN BY:
END STUB STUB
NSL NSL GRANULAR PALTFORM
DR. WA SIM / DR.ANWAA R / A BID A LI
DRAW N BY:

RAJA FA RHA T
EXCAVATE TO NEAT LINES, PLACE 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
500 600 500 600 CHECKED BY:
THE STONES AND GROUT. 2. EXPANSION JOINT IN GROUTED RIPRAP SHALL BE PROVIDED AT A MAXIMUM INTERVAL
OF 10m AT NO EXTRA COST TO THE EMPLOYER. DR. A NWAA R
EXPANSION JOINT
3. SUPPLY AND ERECTION OF STEEL ANGLE STAKES SHALL BE CONSIDERED SUBSIDIARY
(SEE NOTE-2) APPROVED BY:
WORK TO THE VARIOUS PAY ITEMS OF BOQ AND SHALL NOT BE PAID SEPARATELY.
4. IN CASE ROCK IS ENCOUNTERED, DEPTH AND W IDTH OF PROTECTION WORKS SHALL DR. WA SIM
SECTION A - A SECTION B - B BE ADJUSTED AS DIRECTED BY ENGINEER.
SCA LE:
5. LOCATION, TYPE & HEGHT / DEPTH OF PROTECTION WORKS SHALL BE SHOWN ON
DRAW INGS AND / OR AS DIRECTED BY THE ENGINEER N.T.S.
6. PROVIDE GABION MATTERN PROTECTION AT LOCATION INDICATED ON PLAN OR AS
DATE:
DIRECTED BY THE ENGINEER.
7. SBP = SHOULDER BREAK POINT. JULY, 2017

CA D FILE NAM E:

DD&C/LSM/GEN/10