Professional Documents
Culture Documents
Diagrama Eléctrico Jumbo Sandvik dd321
Diagrama Eléctrico Jumbo Sandvik dd321
TABLE OF CONTENTS
SHEET REVISION CONTENTS REVISION INFO
1 CONTENTS AND INDEX LIST
2 F MAIN CABINETS WIRING 2010-11-16 PCH Cables 3x1.5 & 2x1.5 replaced by 3x1 & 2x1
3 B E.S. BUTTON AND SWITCHES 2007-09-06 PCH Bridge over 1SH78 added
4 H POWER SUPPLY OF CONTROL SYSTEM 2012-03-08 GSN Modification button S6 by 3 positions
5 G EXTERNAL PUMP BUTTON 2011-10-05 PLE Added the by pass Safety trip wire
6 D 1-BOOM HOLDING MAGNETS 2009-01-28 PYM Wiring modification QN-H126 added
QN
SW
MP
W42
1W94
1W93
7x0.5+C
50x1.0
3x1.0
1W102 36x1.5
1X102
1JB102
WY40
1WS126 2x1.0
1WS190 2x1.0
1WY47
WY41
1WS80
1WS81
WS24
3x0.75
3x0.75
3x0.75
4x0.75+C
4x0.75+C
2x1.0
p p
1S126
1S190
1Y47
Y40
Y41
1S80
1S81
DCM
PRESS.SW. (OPTION)
AMORTISSEMENT STABILATOR (OPTION)
PERCUSSION HOURMETER
HORAMETRE FRAPPE
CONTROL PANEL
BUTTON OF
EMERGENCY STOP
POSTE OPERATEUR
D’URGENCE
BOUTON ARRET
AUTO/MANUAL USE
WATER PUMP CONTROL
POMPE A EAU
COMMANDE AUTO/MANU
AUTO/MANU USE
COMPRESSOR CONTROL
COMPRESSEUR
COMMANDE AUTO/MANU
RESET
PRESSURE SWITCH
PRESSOSTATS
REMISE A ZERO
SWITCH
START-STOP
POWERPACK
POWERPACK
MARCHE-ARRET
COMMUTATEUR
MP
X500 526 X500 577 X500 506 X500 510 X500 509 X500 512 X500 511 X500 513 X110 17 1X110 131 1X110 130 X500 501
1W102 01 1W102 02 1W102 03 1W102 17 1W102 18 1W102 19 1W102 20 1W102 21 1W102 04 1W102 06 1W102 05 1W102 24
1X102 A11X102 A21X102 A3 1X102 B71X102 B8 1X102 B91X102 B10 1X102 C1 1X102 A41X102 A6 1X102 A51X102 C2 1X102 C4
A1 A2 A3 B7 B8 B9 B10 C1 A4 A6 A5 C2 C4
1X1 1 1X1 2 1X1 3 1X1 17 1X1 18 1X1 19 1X1 20 1X1 21 1X1 4 1X1 6 1X1 5 1X1 22 1X1 24
+1JB102
1W94 01 1W94 02 1W94 03 1W94 17 1W94 18 1W94 19 1W94 20 1W94 21 1W94 04 1W94 06 1W94 05 1W94 22 1W94 24
1X94 1 1X94 2 1X94 3 1X94 17 1X94 18 1X94 19 1X94 20 1X94 21 1X94 4 1X94 6 1X94 5 1X94 22 1X94 24
1 2 3 17 18 19 20 21 4 6 5 22 24
24
5/25
+1JB94
1 2
3 1
SH501 0 STOP
SH502 1 RUNNING
1S78 S START
4 2
BY ELEC/DIESEL
DRILLING POWERED
ELEC/DIESEL
FORATION MODE
SWITCH GEAR
OF MAIN
CONTROL FUSES
PRINCIPALE
DE L’ARMOIRE
DISJONCTEURS
HOURMETER
PERCUSSION
FRAPPE
HORAMETRE
1X102
MP-1X110 122 1W102 07 A7 A7 1X1 16 1/710
6/11
1X94 16
1X102 B4 B6 C2
1X1 13
1JB94
OPTION DIESEL/DIESEL-ELEC
16
B4 B6 C2
1WS190 01
1THC- S534
13
3 3
1S190 p 3 1
3 1
1X1 34 1X1 35 1X1 36 14
4 4
1WS190 02
1JB102 +24VDC 1X1 14
37 38
1X94 37 38
MAIN PANEL POWER SUPPLY
-0VDC
1W94 37 38
1W94 34 1W94 35 1W94 36 1X102
MP-1X110 124 1W102 11 B1 B1
ALTERNATIVES
1.4 2.4
S6 2 2
1X102
1W102 13 B3 B3
BU BU
1JB94 1X102 WY40 BU
S6 13 23 MP-X500 501 1W102 12 B2 B2 1X1 12 WY41 BU 1/702
DRILLING POWERED 6/11
1 X BY DIESEL ENGINE W94 12
0 12 12 2/702
DRILLING POWERED
2 X BY ELECTRIC MOTOR 1JB94-1X94
14 24
(OPTION)
EXTERNAL PUMP
(OPTION)
POMPE EXTERNE
(OPTION)
TEST
EXTERNAL PUMP
(OPTION)
EXTERNE
TEST POMPE
(OPTION)
BY PASS
SAFETY TRIP WIRE
(OPTION)
A CABLE
BY PASS A.U.
(OPTION)
LAZER FOR TCAD
(OPTION)
LASER POUR TCAD
MP +DCM
X500 539 X500 541 X500 591 X500 544 X500 508 X500 547 X500 546 X500 595 579 X500 578 506
X901 922
WS24 02
1W102 26 1W102 27 1W102 28 1W102 29 1W102 30 1W102 31 1W102 32 1W102 34 23 1W102 36 35
1X1 40
C6 C7 C8 C9 C10 D1 D2 D4 C3 D6 D5 JB102
1X102 1X102 1X102 1X102 1X102 1X102 1X102 1X102 1X102
C6 C7 C8 C9 C10 D1 D2 D4 C3 D6 D5
1W94 40
JB102 1X1 26 1X1 27 1X1 28 1X1 29 1X1 30 1X1 31 1X1 32 1X1 48 47 1X1 50 49
40
1X94
40
JB94
S24
1 2 1.3
1W94 26 1W94 27 1W94 28 1W94 29 1W94 30 1W94 31 1W94 32 1W94 48 47 1W94 50 49
1.4
1X94 39
39
1X1 39
S503 1.3 2.1
S504 2.3 1.1 1.1 2.3 3.X1 JB102
0 1 S 1 0 2 SH66
WS24 01
1.4 2.2 2.4 1.2 1.2 2.4 3.X2
24 3/30
+DCM
X901 927
1 2 2 1
S503 3 1 S504 3 1
0 STOP 2
1 RUNNING 0
S START 1
4 2 4 2
(OPTION)
INDICATOR LIGHT
SLU OIL FLOW
(OPTION)
HUILE SLU
VOYANT DEBIT
PERCUSSION
FRAPPE
FEED
POUSSEE
ROTATION
ROTATION
FRONT LIMIT
LIMITE AVANT
BACK LIMIT
LIMITE ARRIERE
(OPTION)
PRESS.SW.
STABILATOR
AMORTISSEMENT
PRESSOSTAT
(OPTION)
SLU OIL FLOW
DEBIT HUILE SLU
1/8
4/30
1/710 1X1 16
4/30
24VDC 1X1 7
IS NOT
ONLY IF STAB.
1K70 Settings: 1W94 07
11
Multi timer 1K74 1JB94 1X94 7
-> Range= 0.1-1s 28 7 1WS80 03 1WS81 03
-> Setting= 2 12 14 1 2
1S73 3 1 1S73
-> Function= C 2.1 1.3
1S80 1S81
M M A B 2 3 2 3
A X p p
B XX 2.2 1.4 1 1
IS NOT
ONLY IF SLU
4 2
9 10
1K73 11
RETURN AUTO 1X94 9 1X94 10
29
M=OFF 1W94 09 1W94 10 1WS80 01 1WS81 01
12 14 A=RETURN AUTO 1X1 9
B=FORCED RETURN 11
1K72
27
14 12
15 11
1
1K70 1K71 1WS126 01
23 1XV1 25
18 16 2 14 12
5
1XV2 1S126 13
1X1 11 3 4 1X1 8 1XV3
p
1W93 01 1W93 02
6 1XV4
1X1 10 7 8 14
1JB93 1WY47 BR
1 1JB93-1X1 1 1JB93-1X1 2
W42 04 W42 01
-1X1 1Y47 BR
1S70 1S71 1S72 1WS126 02
10 BK BK BK BK BK BK 1 Y1 A1 A1 A1
24 20
QN- QN- 1XV5 1K70 1K71 1K72
H126 1H72 9 2 A2 A2 A2
BK BK BK BK BK BK
31 31 0.2s
1JB93 1JB93 1JB93 BU
-1X1 3 -1X1 3 -1X1 3
1K74 A1 A1
+1THC 1WY47 BU 1K73
DP-BOX
1W93 03 A2 A2
W42 07 TMS DD/DDS/DDSS
OPTION
1/702 1X1 12
4/30
18 15 15 14 11 23 14 11 19 14 11 13 14 11 13
ELECTRO-AIMANTS DE MAINTIEN DES JOYSTICKS
16 12 12 12 12
HOLDING MAGNETS OF THE JOYSTICKS
1K70 1K71 1K72 1K74 1K73