You are on page 1of 1

Vishwa Samudra Engineering Standards QCDPIR-VSE-MEC-0013 Rev.

00

DYE PENETRENT TESTING REPORT


Project WLS Phase-1 Report No. DTIR/2018/031
Client KPCL, Nellore Date Of Inspection 05-12-2018
Light Intensity 1000 Lux Accessibility Good
Area / Location Silo-1 (SS-Vertical Stiffeners) Specification ASME Sec.V, AWS D1.1
Liquid Penetrant Testing Equipment:
Manufacturer Expiry Date Batch No.
Penetrant CHECKMATE July-2019 P-224
Cleaner CHECKMATE Aug-2019 C-286
Developer CHECKMATE Dec-2019 D-284
Method Description:
Non- Ambient Material
PT Technique 35°C 32°C
Fluorescent Temperature Temperature
Penetrant Developer
Penetrant Type Solvent Spray Spray
Application Application
Pre-Cleaning Developing
Solvent Cleaner Dwell Time 10 Min. 5 min.
Method Time
Testing Area: Flame Cutting Bevel Edges and Temporary Welds Grinding Area.
Material Surface Condition: Surface Grinded
Joint Material Total Testing Evaluation
Drawing No./ Item Description Thickness
No. Type Length/Area Result
192600001-DRW-ME-WLS-1010 SS-07 SS 75mm 16 mm See Comments
192600001-DRW-ME-WLS-1010 SS-14 SS 150mm 16 mm See Comments
192600001-DRW-ME-WLS-1010 SS-21 SS 100mm 16 mm See Comments

Joints Offered: 03. Joints Accepted: 03. Joints Rejected: 0.


Comments:

No Visible Discontinuities Found on Tested Area.

Vishwa Samudra Engineering TUV-SUD South Asia Pvt Ltd. Krishnapatnam Port Co Ltd.
QC
Pvt Ltd. (VSE) (TPI) (KPCL)
Name D HARI KISHORE K Siva Kumar K prudhvi
Signature
Date

You might also like