Professional Documents
Culture Documents
Hull Inspection Reportwbt-1s
Hull Inspection Reportwbt-1s
SIMA
2009-11-19
Nauticus Hull Integrity Report
SIMA– No.1 W.B.T. (S)
1 STATEMENT OF FACTS
Tank No.1 W.B.T. (S) onboard the SIMA, was inspected on 2009-11-19 by Chief Officer
FATHI.
2.1 Coating
Coating found in general INTACT condition. The following coating failures were found:
General Edge Weld Cracking Blistering Flaking
No No No No No No
2.2 Anodes
The general condition of anodes was found to be: 0 - No weardown.
2.3 Structure
The tank was “credited” on an overall level when ‘0’ is given for the different structural
failure types below, but check for any deviations in chapter 4:
Corrosion Pitting Deformations Crack Outfitting
0 - No corrosion 0 - No pitting 0 - No 0 - No visible 0 - No
deformation cracks
2.4 Sediments
The amount of sediments (mud/sludge) was evaluated to be: No sediments.
Page 3 of 10
Nauticus Hull Integrity Report
SIMA– No.1 W.B.T. (S)
Page 4 of 10
Nauticus Hull Integrity Report
SIMA– No.1 W.B.T. (S)
3 INSPECTION FORM
The details for each reporting cell were as follows:
Coating Structure
Failure mode
Deformations
Corrosion 2)
Outfitting 6)
Blistering
Cracking
Inspected
Pitting 3)
General
Flaking
Location
Crack 5)
Status
Cell No
Edge
Weld
Anodes
1)
4)
Upper
0 - No
1 part #87- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#88
Upper
0 - No
2 part #88- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#89
Upper
0 - No
3 part #89- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#90
Upper
0 - No
4 part #90- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#91
Upper
0 - No
5 part #91- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#92
Upper
0 - No
6 part #92- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#93
7 Upper Yes INTACT No No No No No No 0 - No 0 0 0 0 0
Page 5 of 10
Nauticus Hull Integrity Report
SIMA– No.1 W.B.T. (S)
Coating Structure
Failure mode
Deformations
Corrosion 2)
Outfitting 6)
Blistering
Cracking
Inspected
Pitting 3)
General
Flaking
Location
Crack 5)
Status
Cell No
Edge
Weld
Anodes
1)
4)
part #93- weardown
#94
Middle
part, 2 nd 0 - No
8 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #93- weardown
#94
Middle
part, 2 nd 0 - No
9 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #92- weardown
#93
Middle
part, 2 nd 0 - No
10 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #91- weardown
#92
Middle
part, 2 nd 0 - No
11 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #90- weardown
#91
Middle
part, 2 nd 0 - No
12 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #89- weardown
#90
Middle 0 - No
13 Yes INTACT No No No No No No 0 0 0 0 0
part, 2 nd weardown
Page 6 of 10
Nauticus Hull Integrity Report
SIMA– No.1 W.B.T. (S)
Coating Structure
Failure mode
Deformations
Corrosion 2)
Outfitting 6)
Blistering
Cracking
Inspected
Pitting 3)
General
Flaking
Location
Crack 5)
Status
Cell No
Edge
Weld
Anodes
1)
4)
lvl. #88-
#89
Middle
part, 2 nd 0 - No
14 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #87- weardown
#88
Middle
part, 1 st 0 - No
15 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #87- weardown
#88
Middle
part, 1 st 0 - No
16 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #88- weardown
#89
Middle
part, 1 st 0 - No
17 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #89- weardown
#90
Middle
part, 1 st 0 - No
18 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #90- weardown
#91
Middle 0 - No
19 Yes INTACT No No No No No No 0 0 0 0 0
part, 1 st weardown
Page 7 of 10
Nauticus Hull Integrity Report
SIMA– No.1 W.B.T. (S)
Coating Structure
Failure mode
Deformations
Corrosion 2)
Outfitting 6)
Blistering
Cracking
Inspected
Pitting 3)
General
Flaking
Location
Crack 5)
Status
Cell No
Edge
Weld
Anodes
1)
4)
lvl. #91-
#92
Middle
part, 1 st 0 - No
20 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #92- weardown
#93
Middle
part, 1 st 0 - No
21 Yes INTACT No No No No No No 0 0 0 0 0
lvl. #93- weardown
#94
Lower
0 - No
22 part #93- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#94
Lower
0 - No
23 part #92- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#93
Lower
0 - No
24 part #91- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#92
Lower
0 - No
25 part #90- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#91
Lower 0 - No
26 Yes INTACT No No No No No No 0 0 0 0 0
part #89- weardown
Page 8 of 10
Nauticus Hull Integrity Report
SIMA– No.1 W.B.T. (S)
Coating Structure
Failure mode
Deformations
Corrosion 2)
Outfitting 6)
Blistering
Cracking
Inspected
Pitting 3)
General
Flaking
Location
Crack 5)
Status
Cell No
Edge
Weld
Anodes
1)
4)
#90
Lower
0 - No
27 part #88- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#89
Lower
0 - No
28 part #87- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#88
Lower
0 - No
29 part #87- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#88
Lower
0 - No
30 part #88- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#89
Lower
0 - No
31 part #89- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#90
Lower
0 - No
32 part #90- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#91
Lower
0 - No
33 part #91- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#92
Lower 0 - No
34 Yes INTACT No No No No No No 0 0 0 0 0
part #92- weardown
Page 9 of 10
Nauticus Hull Integrity Report
SIMA– No.1 W.B.T. (S)
Coating Structure
Failure mode
Deformations
Corrosion 2)
Outfitting 6)
Blistering
Cracking
Inspected
Pitting 3)
General
Flaking
Location
Crack 5)
Status
Cell No
Edge
Weld
Anodes
1)
4)
#93
Lower
0 - No
35 part #93- Yes INTACT No No No No No No 0 0 0 0 0
weardown
#94
Page 10 of 10