You are on page 1of 24

HV

VAC && Refriggeration Systemms for Maarine annd Offshhore

PRODUCT CATALOGUE

CENTRIFUGAL
FANS
CENTRIFUGAL 
!

" # $ % & "


'

(
! )

* +

,+( -../01..2
PRODUCT CATALOGUE

73-16 CENTRIFUGAL FANS

CONTENT PAGE

1. CENTRIFUGAL FANS WITH STANDARD MOTOR – TN, HN ......................................................4


2. MARINE CENTRIFUGAL FANS – WPM ........................................................................................11
3. MARINE ALUMINUM CENTRIFUGAL FANS – WPMA ..............................................................17
4. MARINE CENTRIFUGAL RECIRCULATION FANS – WPM/R ...................................................20
5. MARINE PORTABLE CENTRIFUGAL FANS – WPMA/P-140 .....................................................21

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
CENTRIFUGAL FANS 73-16-100
WITH STANDARD MOTOR – TN, HN 2013

DESCRIPTION

TN/HN direct driven fans are designed for light industrial applications. They are used to convey clean or
lightly polluted air and non-aggressive gases. The fan casings are not gas tight. The permissible
temperature range of the conveyed medium is -30oC to +60oC. The housing of the fans is made of
galvanized sheet steel. Painted or powder coated casings are available. The TN type unit has forward-
curved impellers which are made of galvanized steel, designed for high circumferential speed. The inlet
cones are manufactured from galvanised steel or glass fibre reinforced polyamide. The HN type unit has
backward-curved impellers are made of seawater proof aluminium. Their low mass moment of inertia
allows reducing motor sizes. The inlet cones are made of galvanised steel. All fan impellers are statically
and dynamically balanced in two plains to quality level G 2.5 (DIN ISO 1940). All fans are also
equipped with standard IEC-motors of flange or foot type. Protection class is IP55 and isolation class F.
The permissible ambient temperature range is -20oC to 40oC. Up to motor size 100, voltage controllable
motors are available. All units can be executed as fitted type fans with a B5 flange motor (TNF/HNF).
The side plates and the scroll plate are joined together by a standing seam. The mounting feet are
screwed to the fan casing. The discharge orientation can therefore easily changed in step of 90o.
The TNQ/HNQ type fans feature a square side plate that allows the installation of a B3 foot motor.
The side plates and scroll are riveted. All presented data accords to 50Hz supply.

DIMENSIONS

Dimensions [mm]
Type Size
A B C D F H I J d max
TNF-2 160 306 154 158 159 128 359 156 129 240
HNF-2 180 337 467 172 172 143 394 168 141 269
160 306 154 158 159 128 359 156 129 210
180 337 467 172 172 143 394 168 141 210
TNF-4
200 367 179 196 189 157 433 181 154 210
HNF-4
225 405 195 212 205 176 476 196 169 269
250 442 211 235 218 194 515 216 187 326
TNF-6 250 442 211 235 218 194 515 216 187 210
HNF-6 280 487 229 262 243 216 573 236 212 269

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
CENTRIFUGAL FANS 73-16-100
WITH STANDARD MOTOR – TN, HN 2013

Dimensions [mm]
Type Size
A B C D E F G H
200 75 233 85 180 263 233 75 66
TNQ-2
225 100 220 82 205 280 220 138 170
HNQ-2
250 116 220 97 205 300 220 163 199
200 75 233 85 180 263 233 75 166
225 100 220 82 205 280 220 138 170
250 116 220 97 205 300 220 163 199
TNQ-4 280 50 400 105 280 321 440 84 219
HNQ-4 315 52 440 110 230 365 440 120 256
355 80 440 137 255 392 440 159 288
400 125 417 151 305 416 417 125 299
450 111 503 146 305 503 606 111 333
250 116 220 97 205 300 220 163 199
280 50 400 105 280 321 440 84 219
315 52 440 110 230 365 440 120 256
TNQ-6 355 80 440 137 255 392 440 159 288
HNQ-6 400 125 417 151 305 416 417 125 299
450 111 503 146 305 503 606 111 333
500 152 496 177 305 537 614 152 387
560 169 554 216 305 591 692 169 443

Discharge orientation viewed from drive side

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
CENTRIFUGAL FANS 73-16-100
WITH STANDARD MOTOR – TN, HN 2013

TECHNICAL SPECIFICATION

Relative octave sound power level, A – weighted


HN… dB(A) LwA 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz
outlet 0 -23 -15 -7 -2 -3 -7 -10
2-pol
inlet -3 -19 -14 -10 -9 -7 -8 -14
outlet 0 -22 -13 -5 -4 -7 -8 -15
4-pol
inlet -3 -21 -16 -12 -8 -8 -12 -18

HN…-2; 50Hz

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
CENTRIFUGAL FANS 73-16-100
WITH STANDARD MOTOR – TN, HN 2013

HN…-4; 50Hz

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
CENTRIFUGAL FANS 73-16-100
WITH STANDARD MOTOR – TN, HN 2013

Relative octave sound power level, A – weighted


TN… dB(A) LwA 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz
outlet 0 -23 -11 -2 -5 -6 -12 -22
2-pol
inlet -3 -18 -12 -7 -5 -9 -11 -20
outlet 0 -18 -8 -8 -7 -12 -20 -26
4-pol
inlet -3 -19 -13 -8 -10 -11 -18 -25
outlet 0 -16 -10 -10 -9 -17 -23 -30
6-pol
inlet -3 -19 -13 -10 -12 -14 -23 -31

TN…-2; 50Hz

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
CENTRIFUGAL FANS 73-16-100
WITH STANDARD MOTOR – TN, HN 2013

TN…-4; 50Hz

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
CENTRIFUGAL FANS 73-16-100
WITH STANDARD MOTOR – TN, HN 2013

TN…-6; 50Hz

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
73-16-200
MARINE CENTRIFUGAL FANS – WPM
2013

DESCRIPTION

Marine centrifugal fans WPM are destined for operation in the ventilation systems of seagoing ships
with unrestricted cruising area as well as offshore objects. They may be used as exhaust or supply fans
and be installed inside the compartments. WPM fans are of compact, sturdy construction and equipped
with high efficient impeller with backward-curved blades. Working parameters of fans are shown on
performance curves Pt=f(V) with respect to inert gas of specific density =1,2kg/m3 and temperature
t= 20oC, where:
Pt (Pa) – fan total pressure,
V (m3/s) – air displacement.
Allowable tolerances of working parameters of fans (air displacement, pressure, power consumption and
efficiency) are in accordance with standard PN-77/M-43021. Temperature of conveyed medium should
not exceed +45oC, dust contents 0,3g/m3. Surface treatment – hot-dip galvanized.
Housing is made of carbon steel. Impeller is made of sea water resistant aluminum alloys. Electric motor
is executed as marine, induction, squirrel-cage and three-phase. It is suitable for 50 or 60Hz electric
installation. Smaller motors are coupled directly to fan casings, larger fitted on supporting pedestal. Fans
in explosion-proof execution are fitted with brass lining on inner surface of housing in way of impeller.
On request fans may be supplied with flanged flexible connections for inlet and/or outlet and set of
shock absorbers.

MARKING

Example: WPM type fan of nominal diameter DN=160, with impeller speed 3500 min-1, with RD0
position: WPM 160/4-RD0

TECHNICAL SPECIFICATION & DIMENSIONS

Impeller speed:
1 – 1450 min-1 (50 Hz)
2 – 2900 min-1 (50 Hz)
3 – 1750 min-1 (60 Hz)
4 – 3500 min-1 (60 Hz)

Discharge orientation viewed from drive side

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
73-16-200
MARINE CENTRIFUGAL FANS – WPM
2013

Nominal airflow Total nominal Impeller speed Maximum noise


Fan type Supply [V/Hz]
[m3/s] pressure [Pa] [1/min] level [dB(A)]
160/1 0.085 145 1340 71
160A/1 0.12 185 1340 73
200/1 0.17 230 1400 78
200A/1 0.24 290 1400 79
250/1 0.34 360 1400 84
250A/1 0.49 450 1420 85
315/1 0.69 565 1420 92
315A/1 0.97 705 1420 93
400/1 1.37 880 1430 98
400A/1 1.92 1100 1435 99 3x380/50
450A/1 2.65 1350 1450 104
125A/2 0.11 435 2800 84
160/2 0.16 540 2800 87
160A/2 0.23 690 2820 90
200/2 0.33 870 2820 94
200A/2 0.47 1120 2820 96
250/2 0.66 1380 2860 99
250A/2 0.95 1750 2910 101
315/2 1.32 2170 2910 105
160/3 0.10 210 1610 73
160A/3 0.14 265 1610 76
200/3 0.20 335 1700 82
200A/3 0.29 415 1700 84
250/3 0.41 525 1720 88
250A/3 0.58 660 1720 89
315/3 0.83 830 1710 96
315A/3 1.18 1040 1720 97
3x440/60
400/3 1.65 1310 1720 103
400A/3 2.38 1660 1755 104
125A/4 0.146 675 3400 88
160/4 0.21 850 3400 90
160A/4 0.29 1060 3400 92
200/4 0.41 1320 3400 98
200A/4 0.58 1660 3450 100
250/4 0.79 2050 3500 104

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
73-16-200
MARINE CENTRIFUGAL FANS – WPM
2013

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
73-16-200
MARINE CENTRIFUGAL FANS – WPM
2013

Fan type 125A 160 160A 200 200A 250 250A 315 315A 400 400A 450A
DN 125 160 200 250 315 400 450
A 170 216 270 335 420 535 600
A1 125 160 200 245 310 390 435
B 210 262 327 402 505 632 703
C 90 100 110 120 130 150 165 190 205 240 260 295
D3 - - - 320 330 420 450 520 465 490 580 650
D5 230 275 285 300 310 320 350 390 420 500 - -
E 117 150 187 234 295 374 420
H2 150 190 240 295 370 470 530
I 160 200 250 315 400 500 560
J 164 180 196 214 234 266 290 308 338 382 412 468
Dimensions [mm]

K - - - 112 123 133 146 158 173 190 210 234


L - - - 110 120 130 143 150 165 185 200 230
M - - 150 200 200 250 280
N - - 250 315 400 500 560
ØD 12 12 12 15 15 15 15
a 184 224 280 336 420 516 566
b 166 206 260 316 396 492 542
c 140 180 225 280 355 450 500
e 170 172 186 216 236 256 282 316 336 382 422 468
f 152 154 169 196 216 236 262 292 322 358 398 444
g 120 125 140 160 180 200 225 250 280 315 355 400
h 200 225 280 370 440 540 600
j 180 210 260 340 410 510 570
k 160 190 240 306 380 480 540
nxØp 4x7 8x7 8x9 10x9 10x9 16x9 14x9
mxØr 6x7 8x7 8x9 8x9 12x9 16x9 16x9

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
73-16-200
MARINE CENTRIFUGAL FANS – WPM
2013

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
73-16-200
MARINE CENTRIFUGAL FANS – WPM
2013

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
73-16-210
MARINE ALUMINUM CENTRIFUGAL FANS – WPMA
2013

DESCRIPTION

Aluminum marine centrifugal fans WPMA are destined for operation in ventilation and air conditioning
systems of seagoing vessels and offshore objects. Operating data of fans are presented on enclosed
performance curves Pt=f(V), where:
Pt – total pressure, Pa,
V – airflow, m3/s.
Allowable tolerances of operating conditions (airflow, pressure, power consumption and efficiency)
comply with the standard PN-77/M-43021. Temperature of conveyed medium must not exceed +45oC,
dust contents 0,15g/m3. Housing and impeller of WPMA fans are made of sea water resistant aluminum
alloy, welded. Electric motor is executed as induction, marine type, squirrel cage, three-phase.
It’s supply: 50 or 60Hz.

MARKING

Example: WPMA type fan of nominal diameter 140mm, with type 1 impeller and position RD0:
WPMA-140/1-RD0

TECHNICAL SPECIFICATION & DIMENSIONS

Nominal airflow Total nominal Impeller speed Maximum noise


Fan type Supply [V/Hz]
[m3/s] pressure [Pa] [1/min] level [dB(A)]
140/1 0.10 1500 2820 90
140/2 0.25 1500 2780 94 3x380/50
160/1 0.33 2000 2835 96
140/1 0.12 2160 3400 96
140/2 0.30 2160 3440 98 3x440/60
160/1 0.40 2880 3455 101

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
73-16-210
MARINE ALUMINUM CENTRIFUGAL FANS – WPMA
2013

Dimensions [mm]
Fan type
A B C D E F G H J K L M N O
140/1 140 100 120 235 195 215 255 71 195 245 90 100 90 112
50Hz 140/2 140 100 120 235 195 215 255 80 195 270 90 105 100 125
160/1 160 110 160 270 218 244 296 90 216 315 95 117 100 140
140/1 140 100 120 235 195 215 255 80 140 250 90 105 100 125
60Hz 140/2 140 100 120 235 195 215 255 90 140 310 90 110 100 140
160/1 160 110 160 270 218 244 296 90 216 340 95 117 125 140

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
73-16-210
MARINE ALUMINUM CENTRIFUGAL FANS – WPMA
2013

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
73-16-220
MARINE CENTRIFUGAL FANS – WPM/R
2013

DESCRIPTION

Marine centrifugal fans WPM/R are destined for recirculation of air in ro-ro holds, engine rooms etc.
They are provided with distributing box with studs for connection of spiral ductwork terminated with
diffuser nozzles. Marine centrifugal fans WPM/R consist of marine centrifugal fan WPM, noise silencer
with protecting wire guard (13x13mm) fitted on the inlet and the distributing box with studs for
connection of spiral pipes on outlet. Fan is resiliently seated on foundation frame by means of rubber
shock absorbers. Electric motor is in marine execution, explosion proof on request. Surface treatment:
hot-dip galvanized. For determining of fan working parameters see 73-16-200.

MARKING

Example: WPM/R type fan of nominal diameter DN=200mm, in left position L (see drawing below), in
Ex non-sparking execution: WPM/R-200-L-Ex

TECHNICAL SPECIFICATION & DIMENSIONS

Fan Dimensions [mm] Weight


type A B C D F G H J K L [kg]
200 270 400 325 260 440 395 200 400 300 50 92
250 340 445 445 300 555 470 250 490 390 50 122

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
MARINE PORTABLE 73-16-230
CENTRIFUGAL FANS – WPMA/P-140 2013

DESCRIPTION

Marine aluminum portable centrifugal fans WPMA/P-140 are destined for supply or extract of air from
spaces of seagoing ships or offshore object, that are not provided with forced ventilation system.
Operating data of fans are presented on enclosed performance curves Pt=f(V), where:
Pt – total pressure, Pa,
V – airflow, m3/s.
Allowable tolerances of operating conditions (airflow, pressure, power consumption and efficiency)
comply with the standard PN-77/M-43021. Temperature of conveyed medium must not exceed +45oC,
dust contents 0,15g/m3. Housing and impeller of WPMA/P fans are made of sea water resistant
aluminum alloy, welded. Electric motor is induction type, squirrel cage, three-phase, in marine
execution. Electric supply: 50 or 60Hz. Fans are provided with WPD-381 start/stop switch and 20m long
supply cable without terminal connector. Accessories: storage aluminum box (standard outfitting),
DN160 flexible hoses (number of hoses must be specified at the order).

MARKING

Example: WPMA/P-140 destined for operation in 50Hz electrical installation: WPMA/P-140-50 Hz

TECHNICAL SPECIFICATION & DIMENSIONS

Nominal airflow Nominal total Impeller speed Maximum noise


Fan type Supply [V/Hz]
[m3/s] pressure [Pa] [1/min] level [dB(A)]
140/2 0.25 1500 2780 94 3x380/50
140/2 0.30 2160 3440 98 3x440/60

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
MARINE PORTABLE 73-16-230
CENTRIFUGAL FANS – WPMA/P-140 2013

Heating, Ventilation, Air Condition & Refrigeration Systems for Marine and Offshore Purposes www.teknotherm.pl
! " # $

%%% # & ' (


' &) # & '

! !" # $ # % % #

You might also like