You are on page 1of 86

“B

106,0 “K
(4.17) ga

25,0
Piston Pumps
Technical Focus

M-Series Mobile
Variable Displacement
Introduction

M Series mobile pumps are open circuit, axial piston Mounting flanges are offered in SAE and ISO config-
designs. A variety of controls provides the ability to urations, and ports are offered in SAE, ISO, and BSPP
match the pumps to each application. Efficiency of the in both tube and flange versions. This provides a
pump controls allows down-sizing of system cooling wide variety of installation opportunities for global
needs, allowing a smaller and less expensive design to machine design.
be used. Alternatively, cooling capacity could be kept
Side- or end-ported models are available to facilitate
the same and the flow capability of the system
plumbing and help fit the pump to your machine space
increased, thus improving performance and customer
needs. Multiple drain ports allow many mounting
satisfaction.
orientations, reducing installed costs.
A strong proven rotating group allows the pumps to
M Series pumps are capable of operating with many
handle pressures to 280 bar (4000 psi) continuous and
types of hydraulic fluids used in industrial and mobile
320 bar (4600 psi) intermittent – with less maintenance
systems. High-water-content and phosphate ester
cost. High-load bearings and a stiff drive shaft help
fluids can be accommodated, in addition to the typical
provide a pump life of 5000 hours at rated mobile
petroleum based and synthetic fluids.
conditions, reducing operating costs and extending
operating life.
M Series pumps feature a saddle-type yoke with
steel-backed polymer bearings. The stiff yoke reduces
deflection and allows even loading of bearings, Typical Applications Features and Benefits
improving life. A single control piston reduces loading • Loader backhoes • Long pump life
on the yoke, resulting in reduced pump size which • Vibratory cable plows • Quiet pump operation
allows installation in tighter locations. • Mining machinery • Inlet and outlet gauge ports
• Dump truck lifts
and adjustable maximum
M Series pumps operate at a level of quietness that displacement stops –
exceeds the requirements of today’s demanding work • Agriculture tractors standards
conditions. The pumps feature a unique three-piece • Chemical applicator trucks • Astonishingly low 4%
envelope (flange, housing and valve block) specifically • Railroad equipment pressure ripple
created for low fluid-borne and structure-borne noise • Container handling, all-terrain, • Low installed and
levels. Another pump feature – a bimetal timing plate – and truck cranes operating costs
improves pump filling characteristics which, in turn, • Vibratory cable plows • Reduced maintenance
reduce fluid-borne noise and extend pump life. • Mining machinery and tunnel • Flexibility in machine design
boring equipment • Compact size saves space
Proximity of the pump to the vehicle operator
• Utility boom, off-road dump, • Design promotes leak-free
demands a low noise level in the cab. M Series pumps and refuse trucks system
reduce, or in some cases remove, the need for damp-
• Material handling trucks and
ing barriers between the noise source and the opera- rough terrain fork lifts
tor. This saves money on the installed cost of the
• Concrete and asphalt pavers
system while improving customer comfort.
• Feller/bunchers, forwarders,
An adjustable maximum stop provides a means of and log loaders
tuning flow to your system, while gauge ports allow • Crawler dozers
monitoring of inlet and outlet conditions. These stan- • Articulate haulers
dard features reduce system complexity and cost. • Mini-excavators

2 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Table of Contents

Model Code Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4


Model Code Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Specifications and Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Control Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Performance
PVM018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PVM020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
PVM045 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
PVM050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
PVM057 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
PVM063 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
PVM074. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
PVM081 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
PVM098 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
PVM106. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
PVM131 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
PVM141. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Dimensions
PVM018/020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PVM045/050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
PVM057/063 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
PVM074/081 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
PVM098/106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
PVM131/141 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Mounting Flange Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Shaft Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Input Shaft Selection Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Port Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Operating Requirements and Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Installation and Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 3
Model Code
Selection

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
P V M 0 1 8 M R 0 1 A E 0 1 A A A 2 8 0 0 0 0 0 0 A 0 A

1,2,3 – Product Series 17 – Control


PVM – M Series Variable Piston Pump 0 – None
A – Pressure Compensator
4,5,6 – Displacement B – Pressure and Flow Compensator with Bleed Orifice
Fourteen displacements available C – Pressure and Flow Compensator with Plugged Orifice
230 bar and 280 bar continuous ratings E – Industrial Control (57cc through 141 cc only)

7 – Valve Plate 18,19 – Pressure Compensator Setting


M – Mobile Equipment Speeds 00 – None
07 – 70 bar (Adjustable between 40 bar and 130 bar)
8 – Input Rotation 23 – 230 bar (Adjustable between 130 bar and 320 bar)
28 – 280 bar (Adjustable between 130 bar and 320 bar)
R – Clockwise (Righthand)
L – Counter-clockwise (Lefthand)
20,21 – Flow Compensator Setting
9,10 – Input Shaft 00 – None
11 – 11 bar setting
Standard SAE and ISO splined versions
20 – 20-20 bar setting
(Other configurations optional)
24 – 24-24 bar setting
11 – Mounting Flange
22,23 – Torque Limiter Setting
Thirteen options in SAE and ISO mounts
00 – None (Not available on M Series)
12 – Main Port Location
24 – Compensator Special Features
E – End Ported
0 – None
S – Side Ported
25 – Auxiliary Mounting Pad
13,14 – Main Port Type
0 – None
SAE & ISO tube ports and 4-bolt flange
(Auxiliary mounting available on all frame sizes)
(Other configurations optional)
26 – Paint
15,16 – Pump Special Features
0 – No Paint
00 – None
A – Standard Blue Paint
AA – Adjustable Maximum Displacement Stop and
single shaft (standard)
27 – Customer Identification
AB – Double Shaft Seal, Two Way
0 – None (Contact Eaton for Options)

28 – Design Code
A – A (Initial Release)

4 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Model Code
Options

4,5,6 MAXIMUM GEOMETRIC DISPLACEMENT

Displacement Code 018 020 045 050 057 063 074 081 098 106 131 141
cm3/r 18,0 21,1 45,1 50,0 57,4 63,1 73,7 81,0 98,3 106,5 131,1 141,0
in3/r 1.1 1.29 2.75 3.05 3.50 3.85 4.50 4.94 6.00 6.50 8.00 8.60

9, 10 SHAFT-END TYPE AT PRIME MOVER END

Shaft Code
PVM PVM PVM PVM PVM PVM
Description 018/020 045/050 057/063 074/081 098/106 131/141
SAE J744-16-1, SAE A, Straight Keyed 01 – – – – –
SAE J744-19-1, SAE 19-1, Straight Keyed 02 – – – – –
SAE J744-16-4, SAE A, 9T Spline 03 – – – – –
SAE J744-16-4, SAE A, 11T Spline 04 – – – – –
SAE J744-22-1, SAE B, Straight Keyed 05 05 – – – –
SAE J744-25-1, SAE B-B, Straight Keyed 06 06 06 – – –
SAE J744-22-4, SAE B, 13T Spline 07 07 07 – – –
SAE J744-25-4, SAE B-B, 15T Spline 08 08 08 – – –
SAE J744-32-1, SAE C, Straight Keyed – – 09 09 09 09
SAE J744-38-1, SAE C-C, Straight Keyed – – – 10 10 10
SAE J744-32-4, SAE C, 14T Spline – – 11 11 11 11
SAE J744-38-4, SAE C-C, 17T Spline – – – 12 12 12
SAE J744-44-1, SAE D, Straight Keyed – – – – – 13
SAE J744-44-4, SAE D, 13T Spline – – – – – 14
ISO 3019/2 E20N,
Straight Keyed 15 – – – – –
ISO 3019/2 E25N,
Straight Keyed, Short Spigot 16 – – – – –
ISO 3019/2 E25N,
Straight Keyed 17 17 17 – – –
ISO 3019/2 E32N,
Straight Keyed, Short Spigot – – 18 18 18 18
ISO 3019/2 E40N,
Straight Keyed, Short Spigot – – – 19 19 19

11 MOUNTING FLANGE SPECIFICATIONS

Code Description PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141


A SAE J744-82-2 (A, 2-bolt) ● ● ● ● ● ●
B ISO 3019/2-80A2HW ● ● ● ● ● ●
C SAE J744-101-2 (B, 2-bolt) ● ● ● ● ● ●
D ISO 3019/2-100A2HW ● ● ● ● ● ●
E SAE J744-127-2 (C, 2-bolt) ● ● ● ● ● ●
F ISO 3019/2-125 A2HW ● ● ● ● ● ●
G SAE J744-127-4 (C, 4-bolt) ● ● ● ● ● ●
H ISO 3019/2-125B4HW ● ● ● ● ● ●
J SAE J744-152-4 (D, 4-bolt) ● ● ● ● ● ●
K ISO 3019/2-160B4HW ● ● ● ● ● ●
● = Available
● = Not Available

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 5
Model Code
Options

13,14 MAIN PORT OPTIONS

Inlet/
Code Description Outlet PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141
–24
Inlet –20 –24 – – –
SAE J514 (End ports only)
01
Tube Ports –16
Outlet –12 –16 (End ports only) – – –
SAE J518 Inlet 1.25 inch 2.0 inch 2.0 inch 2.0 inch 2.5 inch 2.5 inch
02
Flange Ports Outlet 0.75 inch 1.0 inch 1.0 inch 1.0 inch 1.0 inch 1.25 inch*
M48
Inlet M42 M48 (End ports only) – – –
ISO 6149-1
03
Tube Ports M33
Outlet M27 M33 – – –
(End ports only)
ISO 6162 Inlet 32mm 51mm 51mm 51mm 64mm 64mm
04
Flange Ports Outlet 19mm 25mm 25mm 25mm 25mm 32mm*
British Standard
05 Parallel Pipe – Inlet G 1-1/4 G 1-1/2 – – – –
Tube Ports Outlet G 3/4 G1 – – – –
*SAE Code 62, high pressure series, or ISO 400 bar. Other flange ports are SAE Code 61, standard pressure series, or ISO 25-350 bar.

25 THRU-DRIVE OPTIONS

Code Description PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141


O Single pump,
non-thru-drive ● ● ● ● ● ●
A SAE A, 2-bolt,
9T spline ● ● ● ● ● ●
B SAE A, 2-bolt,
11T spline ● ● ● ● ● ●
C SAE B, 2-/4-bolt,
13T spline ● ● ● ● ● ●
D SAE B-B, 2-/4-bolt,
15T spline ● ● ● ● ● ●
E SAE C, 2-/4-bolt,
14T spline ● ● ● ● ● ●
F SAE C-C, 2-/4-bolt,
17T spline ● ● ● ● ● ●
G ISO 80-A2HW,
9T SAE spline ● ● ● ● ● ●
H ISO 80-A2HW,
11T SAE spline ● ● ● ● ● ●
J ISO 100-A2/B4HW,
13T SAE spline ● ● ● ● ● ●
K ISO 100-A2/B4HW,
15T SAE spline ● ● ● ● ● ●
L ISO 125-A2/B4HW,
14T SAE spline ● ● ● ● ● ●
M ISO 125-A2/B4HW,
17T SAE spline ● ● ● ● ● ●
● = Available
● = Not Available

6 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Specifications
and Performance

DISPLACEMENT, PRESSURE AND FLOW RATINGS At 93°C (200°F), SAE 10W oil, 1 bar absolute (0 psig) inlet

Geometric Maximum Pressure bar (psi) Maximum Flow at 280 bar (4000 psi)
Displacement Flange Ports Tube Ports
Model Series cm3/r (in3/r) Continuous Intermittent* Peak** l/min (USgpm) @ 1 bar inlet l/min (USgpm) @ 1 bar inlet
PVM018 18,0 (1.10) 280 (4000) 320 (4600) 350 (5000) 46 (12) @ 2800 r/min 46 (12) @ 2800 r/min
PVM020 20,1 (1.22) 230 (3300) 250 (3600) 280 (4000) 53 (14) @ 2800 r/min 53 (14) @ 2800 r/min
PVM045 45,1 (2.75) 280 (4000) 320 (4600) 350 (5000) 115 (30) @ 2600 r/min 106 (28) @ 2400 r/min
PVM050 50,0 (3.05) 230 (3300) 250 (3600) 280 (4000) 125 (33) @ 2600 r/min 116 (31) @ 2400 r/min
PVM057 57,4 (3.50) 280 (4000) 320 (4600) 350 (5000) 140 (37) @ 2500 r/min 128 (34) @ 2300 r/min
PVM063 63,1 (3.85) 230 (3300) 250 (3600) 280 (4000) 150 (40) @ 2500 r/min 140 (37) @ 2400 r/min
PVM074 73,7 (4.50) 280 (4000) 320 (4600) 350 (5000) 163 (43) @ 2400 r/min –
PVM081 81,0 (4.94) 230 (3300) 250 (3600) 280 (4000) 181 (48) @ 2400 r/min –
PVM098 98,3 (6.00) 280 (4000) 320 (4600) 350 (5000) 200 (53) @ 2200 r/min –
PVM106 106,5 (6.50) 230 (3300) 250 (3600) 280 (4000) 222 (59) @ 2200 r/min –
PVM131 131,1 (8.00) 280 (4000) 320 (4600) 350 (5000) 233 (62) @ 2000 r/min –
PVM141 141,0 (8.60) 230 (3300) 250 (3600) 280 (4000) 258 (68) @ 2000 r/min –
**Less than 10% of duty cycle.
**Less than 0.5 second.

STANDARD RESPONSE TIMES* STANDARD RESPONSE TIMES*

Model Series On Stroke (msec) Off Stroke (msec) Model Series On Stroke (msec) Off Stroke (msec)
PVM018 50 20 PVM074 95 30
PVM020 57 22 PVM081 135 30
PVM045 140 40 PVM098 85 24
PVM050 140 23 PVM106 90 25
PVM057 65 20 PVM131 100 30
PVM063 94 20 PVM141 128 28
*Values with pressure compensator control.

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 7
Specifications
and Performance

SPEED, INPUT POWER AND TORQUE RATINGS At 93°C (200°F), SAE 10W oil, 1 bar absolute (0 psig) inlet

Minimum Operating Speed and Pressure r/min


Max. Input Power at Max. Torque at Approximate
1 bar Inlet 0,85 bar Inlet Max. Speed and 280 bar 280 bar (4000 psi) Weight (dry)
Model Series Flange Ports Tube Ports Flange Ports (4000 psi) kW (hp) Nm (lb-ft) kg (lbs)
2800 r/min 24 (32)
PVM018 2800 r/min 24 (32) 82 (60) 15 (33)
2600 r/min 22 (30)
2800 r/min 21 (28)
PVM020 2800 r/min 21 (28) 72 (53) 15 (33)
2600 r/min 20 (27)
2600 r/min 56 (75)
PVM045 2400 r/min 53 (71) 198 (46) 24 (52)
2200 r/min 48 (64)
2600 r/min 51 (68)
PVM050 2400 r/min 48 (64) 204 (150) 24 (52)
2200 r/min 44 (59)
2500 r/min 68 (91)
PVM057 2300 r/min 62 (83) 262 (193) 36 (79)
2100 r/min 56 (75)
2500 r/min 59 (79)
PVM063 2400 r/min 57 (76) 225 (166) 36 (79)
2200 r/min 52 (69)
2400 r/min 84 (113)
PVM074 334 (246) 45 (99)
1900 r/min 69 (93)
2400 r/min 69 (93)
PVM081 276 (204) 45 (99)
1900 r/min 55 (74)
2200 r/min 105 (141)
PVM098 457 (337) 55 (121)
1800 r/min 86 (115)
2200 r/min 87 (117)
PVM106 377 (278) 55 (121)
1800 r/min 70 (94)
2000 r/min 122 (164)
PVM131 581 (429) 66 (145)
1600 r/min 98 (131)
2000 r/min 102 (137)
PVM141 483 (356) 66 (145)
1600 r/min 81 (109)

8 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Control Options

Pressure Compensator
Control – Code A See model code on page 5 for
spring (pressure) adjustment ranges.
The pump will provide a con-
tinuously modulated flow to “B” inlet
meet changing load demands
at a pre-adjusted compensator “F” case drain
pressure. At pressures below • •
the compensator setting, the
pump will operate at maximum “K” inlet •
+
displacement. See model code gage port
on page 4 for compensator
pressure ranges.
Warning: The pressure compen-
sator may be adjusted beyond
the rated pressure of the pump.
When adjusting the pressure • •
limiter, install a 0-350 bar
(0-5000 psi) gage in the outlet “K” outlet •
+

gage port and limit the pressure gage port


setting to the continuous rated
pressure for the pump displace-
“C” outlet
ment shown on page 7.
To load
Pressure Cut-off
Characteristics of Pressure Change in
Compensator Control at Pressure A
93°C (200°F), static conditions. Q

Change
Outlet Flow

in Flow B

Outlet Pressure P

PRESSURE CUT-OFF CHARACTERISTICS OF PRESSURE COMPENSATOR CONTROL @ 93°C (200°F), STATIC CONDITIONS

“P” Outlet
Rated Speed “Q” Outlet Flow Pressure A B
Model Series r/min l/min (USgpm) bar (psi) bar (psi) L/min (USgpm)
PVM018 2800 42 (11) 280 (4000) 2,8 (40) 4,5 (1.2)
PVM020 2800 52 (14) 230 (3300) 2,8 (41) 4,5 (1.2)
PVM045 2600 115 (30) 280 (4000) 10 (150) 4,5 (1.2)
PVM050 2600 125 (33) 230 (3300) 10 (150) 4,5 (1.2)
PVM057 2500 140 (37) 280 (4000) 3,5 (50) 14 (3.7)
PVM063 2500 159 (42) 230 (3300) 7,4 (107) 11,4 (3.00)
PVM074 2400 174 (46) 280 (4000) 1,5 (20) 37 (9.8)
PVM081 2400 185 (49) 230 (3300) 1,5 (22) 37 (9.8)
PVM098 2200 217 (57) 280 (4000) 1,5 (20) 32 (8.4)
PVM106 2200 234 (62) 230 (3300) 1,5 (22) 24 (6.33)
PVM131 2000 253 (67) 280 (4000) 1,0 (15) 23 (6.0)
PVM141 2000 258 (68) 230 (3300) 7,0 (100) 14 (3.70)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 9
Control Options

Load Sensing and Pressure


Compensator Control – Optional bleed-down orifice in
Code B or C Code B control. ∅ 0,4 mm (.015 in.).
Orifice is plugged for no bleed down in
The pump will provide power control Code C.
matching of pump output to
system load demand, maximizing “B” inlet
efficiency and improving load
metering characteristics of any “F” case drain
directional control valve installed
between the pump and the load.
Load sensing ensures that the
pump always provides only the “K” inlet “J” load
amount of flow needed by the gage port sense
load. At the same time, the signal
pump operating pressure adjusts port
to the actual load pressure plus a
pressure differential required for
the control action. When the
system is not demanding power,
the load sense control will oper-
ate in an energy-saving stand-by
“K”outlet
mode. gage port
Typically, the differential
pressure is that between the
pressure inlet and service port of “C” outlet
a proportionally controlled direc-
tional valve, or a load sensing To load
directional control valve. See the
model code on page 4 for differ-
ential pressure settings for load
sensing.
If the load pressure exceeds
the system pressure setting,
the pressure compensator
de-strokes the pump. The load
sensing line must be as short as
possible and can also be used for
remote control or unloading of
the pump pressure. For remote
control purposes, it is recom-
mended that you contact
your Eaton Representative for
the correct configuration of the
control.
Warning: The pressure com-
pensator may be adjusted
beyond the rated pressure of the
pump. When adjusting the pres-
sure limiter, install a
0-350 bar (0-5000 psi) gage
in the outlet gage port and
limit the pressure setting to the
continuous rated pressure for the
pump displacement shown on
page 7.

10 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM018 Typical Noise Levels


Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
(Sound pressure data equivalent to NFPA)
76
2800 r/min
Max. Flow
72

68
Noise Level – dBA

64

60 2800 r/min
Min. Flow
56
600 r/min
52 Max. Flow

48

44 600 r/min
Min. Flow
40
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)

Overall Efficiency Versus Speed


at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
95

90

100 bar
Efficiency – %

(1500 psi)
85
150 bar
(2200 psi)
200 bar
80 (2900 psi)
250 bar
(3600 psi)
75 280 bar
(4000 psi)
320 bar
(4600 psi)
70
0 500 1000 1500 2000 2500 3000
Speed – r/min

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 11
Performance

PVM018 Delivery and Case Flow Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
50 (13.2)

45 (11.9) 25 bar (365 psi),


Delivery
Delivery – l/min (USgpm)

40 (10.6)

35 (9.2)
250 bar (3600 psi),
30 (7.9) Delivery

Case Flow – l/min (USgpm)


25 (5.3)

20 (5.3) 4,0 (1.1)

15 (4.0) 3,0 (.8)


250 bar (3600 psi), Case flow
10 (2.6) 2,0 (.5)

5 (1.3) 1,0 (.3)


25 bar (365 psi), Case flow
0 0
0 500 1000 1500 2000 2500 3000
Speed – r/min

Input Torque Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
110 (973)

100 (885)
320 bar (4600 psi)
90 (796)
Input Torque – Nm (in.lb.)

280 bar (4000 psi)


80 (708)
250 bar (3600 psi)
70 (619)
200 bar (2900 psi)
60 (531)

50 (442) 150 bar (2200 psi)


40 (354)
100 bar (1500 psi)
30 (265)

20 (177)
25 bar (365 psi)
10 (88)

0
0 500 1000 1500 2000 2500 3000
Speed – r/min

12 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM018 Input Power Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
28 (37.5)
320 bar
26 (34.9) (4600 psi)
Input Power @ Full Flow – kW (hp)

24 (32.2) 280 bar


(4000 psi)
22 (29.5)
250 bar
20 (26.8) (3600 psi)
18 (24.1) 200 bar
(2900 psi)
16 (21.4)
14 (18.8) 150 bar
12 (16.1) (2200 psi)
10 (13.4) 100 bar
8 (10.7) (1500 psi)
6 (8.0)
4 (5.4)
25 bar
2 (2.7) (365 psi)
0
0 500 1000 1500 2000 2500 3000
Speed – r/min

Input Torque and Case Flow Versus Speed Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby @ 93°C (200°F), cut-off and 1.0 bar absolute
and 1.0 bar absolute (0 psi gauge) inlet (0 psi gauge) inlet
3 (27) 50 (442)
280 bar (4000 psi)
Input Torque - Nm (in.lb.)

45 (398)
Case Flow (l/min (USgpm)

Input Torque – Nm (in.lb.)

Input Torque
40 (354)
2 (18) 35 (310)
20 bar (300 psi) 30 (265)
differential, 25 (221)
Input Torque 20 bar (300 psi)
differential, 150 bar (2200 psi)
1 (9) Case Flow 5 (1.32) 20 (177) Input Torque
11 bar (160 psi) 4 (1.06) 15 (135) 9 (2.4)
differential, 3 (0.79) 280 bar (4000 psi), Case Flow
Input Torque 11 bar (160 psi) 2 (0.53) 10 (88) 6 (1.6)
differential, 1 (0.26)
0 Case Flow 5 (45) 150 bar (2200 psi) 3 (0.8)
0
0 500 1000 1500 2000 2500 3000 0 Case Flow 0
Speed – r/min 0 500 1000 1500 2000 2500
Speed – r/min

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 13
Performance

PVM020 Typical Noise Levels at 2800 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
77
2800 r/min
74 max. flow
71
68
2800 r/min
min. flow
Noise Level – dBA

65
62
59
56
53
50 600 r/min
47 max. flow
600 r/min
min. flow
44
41
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)

Overall Efficiency versus Speed Delivery and Case Flow versus Speed at 93°C (200°F),
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet Full Flow 1.0 bar absolute (0 psi gauge) inlet
100 60 (15.9)

Case Flow – l/min (USgpm)


95 55 (14.5)
150 bar
(2200 psi) 50 (13.2)
90
Delivery – l/min (USgpm)

210 bar (3000 psi) 45 (11.9)


50 bar (725
Overall Efficiency (%)

85 100 bar (1500 psi) 40 (10.6) psi) Delivery


80 35 (9.2)
50 bar (700 psi) 210 bar (3000
30 (7.9) psi) Delivery
75
230 bar (3300 psi) 25 (6.6)
70
20 (5.3) 4 (1.06)
65
15 (4.0) 3 (0.79)
60 10 (2.6) 210 bar (3000 psi) Case Flow 2 (0.53)
55 5 (1.3) 50 bar (725 psi) Case Flow
1 (0.26)
50 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed – r/min Speed (r/min)

14 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM020

Input Torque versus Speed at 93°C (200°F), Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet Full Flow and 1.0 bar absolute (0 psi gauge) Inlet

110 (973) 24 (32)


230 bar (3300 psi)
100 (885) 22 (30)
90 (796) 20 (27)
Input Torque – Nm (lb.in.)

230 bar (3300 psi) 210 bar (3000 psi)

Input Power – kW (hp)


80 (708) 18 (24)
70 (619) 16 (21)
210 bar (3000 psi)
60 (531) 14 (19)
150 bar (2200 psi) 150 bar (2200 psi)
12 (16)
50 (442)
10 (13)
40 (354) 100 bar (1500 psi) 100 bar (1500 psi)
8 (11)
30 (265)
50 bar (725 psi) 6 (8)
20 (177) 50 bar (725 psi)
4 (5)
10 (88) 2 (3)
0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)

Input Torque and Case Flow versus Speed at Input Torque and Case Flow versus Speed
93°C (200°F), Load Sense Standby and 1.0 bar at 93°C (200°F), Pressure Limit Cut-off and
absolute (0 psi gauge) Inlet 1.0 bar absolute (0 psi gauge) Inlet
3.2 (28) 30 (265)
3.0 (27)
2.8 (25) 27 (239) 210 bar (3000 psi)
Input Torque – Nm (lb.in.)
Input Torque – Nm (lb.in.)

20 bar (290 psi) diff. 24 (212) Input Torque


2.6 (23) Input Torque
2.4 (21) 21 (186)
2.2 (19)
2 (18) 11 bar (160 psi) diff. 18 (159)
1.8 (16) Input Torque
1.6 (14) Case Flow 15 (133) Case
l/min 150 bar Flow l/min
1.4 (12) 12 (106) (2200 psi)
(USgpm) (USgpm)
1.2 (11) Input Torque
1 (9) 5.0 (1.32) 9 (80) 9 (2.4)
.8 (7) 4.0 (1.06)
11 bar (160 psi) diff. 6 (53) 6 (1.6)
Case Flow 3.0 (.79) 210 bar (3000 psi) Case Flow
.6 (5)
20 bar (290 psi) diff. 2.0 (.53)
.4 (4) Case Flow 3 (27) 150 bar (2200 psi) Case Flow 3 (0.8)
.2 (2) 1.0 (.26)
0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 15
Performance

PVM045 Typical Noise Levels


Petroleum Oil (10W) at 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
(Sound pressure data equivalent to NFPA)
82
2600 r/min
Max. Flow
78
Noise Level – dBA

74

70
600 r/min
2600 r/min Min. Flow
66 Min. Flow

62

58
600 r/min
Max. Flow
54

50
0 50 100 150 200 250 300
(700) (1500) (2200) (2900) (3600) (4400)
Outlet Pressure – bar (psi)

Overall Efficiency Versus Speed


at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
95

100 bar
(1500 psi)
90
150 bar
(2200 psi)
Efficiency – %

85 50 bar
200 bar (700 psi)
(2900 psi)

80
250 bar
(3600 psi)
75 17 bar
(250 psi)
280 bar
(4000 psi)
70
0 500 1000 1500 2000 2500 3000
Speed – r/min

16 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM045 Delivery and Case Flow Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
120 (32)
110 (29) 50 bar (700 psi),
Delivery
Delivery – l/min (USgpm)

100 (26)
90 (24)
280 bar (4000 psi),
80 (21) Delivery

70 (18)

Case Flow – l/min (USgpm)


60 (16)
50 (13) 2,5 (.7)

40 (11) 280 bar (4000 psi), 2,0 (.5)


Case flow
30 (8) 1,5 (.4)

20 (5) 1,0 (.3)


50 bar (700 psi),
10 (3) Case flow 0,5 (.1)
0 0
0 500 1000 1500 2000 2500 3000
Speed – r/min

Input Torque Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
225 (1991)
210 (1858) 280 bar (4000 psi)
195 (1726)
250 bar (3600 psi)
180 (1593)
Input Torque – Nm (in.lb.)

165 (1460)
200 bar (2900 psi)
150 (1327)
135 (1195) 150 bar (2200 psi)
120 (1062)
105 (929) 100 bar (1500 psi)
90 (796)
75 (664)
60 (531) 50 bar (700 psi)
45 (398) 25 bar (365 psi)
30 (265)
17 bar (250 psi)
0
0 500 1000 1500 2000 2500 3000
Speed – r/min

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 17
Performance

PVM045 Input Power Versus Speed


93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
56 (75)
280 (4000)
52 (70)
250 (3600)
48 (64)
Input Power @ Full Flow – kW (hp)

44 (59)
40 (54) 200 (2900)

Pressure – bar (psi)


36 (48)
32 (43)
150 (2200)
28 (38)
24 (32)
100 (1500)
20 (27)
16 (21)
12 (16) 50 (700)
8 (11) 25 (365)
4 (5) 17 (250)
0
0 500 1000 1500 2000 2500 3000
Speed – r/min
Case Flow – l/min (USgpm)

1.Case Flow at 2600 r/min, Full Flow


93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
6 (1.6)
5 (1.3)
4 (1.1)
3 (0.8)
2 (0.5)
1 (0.3)
0
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Case Flow at Cutoff at 2600 r/min
Case Flow – l/min (USgpm)

93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet


42 (11.1)
38 (10.0)
34 (9.0)
30 (7.9)
26 (6.9)
22 (5.8)
18 (4.8)
14 (3.7)
10 (2.6)
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)

18 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM050 Typical Noise Levels at 2600 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
88
86
84
82
Noise Level – dBA

2600 r/min
max. flow
80
78 2600 r/min
min. flow
76
74
72 600 r/min
max. flow
70
68
66 600 r/min
min. flow
64
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)

Overall Efficiency versus Speed Delivery and Case Flow versus Speed at 93°C (200°F),
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet Full Flow and 1.0 bar absolute (0 psi gauge) inlet
100

Case Flow – l/min (USgpm)


140 (37)
95 130 (34)
100 bar (1500 psi) 120 (32)
90 110 (29) 50 bar (725
Overall Efficiency (%)

psi) Delivery
Delivery – l/min (USgpm)

85 200 bar 100 (26)


(2900 psi) 210 bar (3000
90 (24) psi) Delivery
80 80 (21)
75 70 (18)
210 bar (3000 psi)
60 (16)
70 210 bar (3000
230 bar (3300 psi) 50 (13) psi) Case Flow 5 (1.32)
65 40 (11) 4 (1.06)
60 30 (8) 3 (0.79)
20 (5) 50 bar (725 psi) 2 (0.53)
55 10 (3) Case Flow 1 (0.26)
0
50 0 500 1000 1500 2000 2500 3000
0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 19
Performance

PVM050

Input Torque versus Speed at 93°C (200°F), Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet Full Flow and 1.0 bar absolute (0 psi gauge) Inlet

300 (2655) 60 (80)


275 (2434) 55 (74) 230 bar (3300 psi)
250 (2212) 230 bar 50 (67) 210 bar (3000 psi)
200 bar (2900 psi)
Input Torque – Nm (in.lb.)

(3300 psi)

Input Power – kW (hp)


225 (1991) 210 bar 45 (60)
(3000 psi)
200 (1770) 40 (54)
175 (1549) 35 (47)
200 bar (2900 psi)
150 (1327) 30 (40)
100 bar (1500 psi)
125 (1106) 25 (34)
100 (885) 20 (27)
100 bar (1500 psi) 15 (20)
75 (664)
50 (442) 10 (13)
17 bar (250 psi) 17 bar (250 psi)
25 (221) 5 (7)

0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)

Input Torque and Case Flow versus Speed at Input Torque and Case Flow versus Speed
93°C (200°F), Load Sense Standby and 1.0 bar at 93°C (200°F), Pressure Limit Cut-off and
absolute (0 psi gauge) Inlet 1.0 bar absolute (0 psi gauge) Inlet
8 (71)
55 (487)

7 (62) 50 (442)
20 bar (300 psi) diff. Case Flow 210 bar (3000 psi) Input Torque
Input Torque 45 (398)
l/min
Input Torque – Nm (in.lb.)

6 (53)
Input Torque – Nm (in.lb.)

(USgpm 40 (354)
210 bar
5 (44) 5.0 (1.32) 35 (310) (3000 psi)
11 bar (160 psi) diff.
Input Torque 30 (265) Case Flow Case
4 (35) 4.0 (1.06) Flow l/min
25 (221) (USgpm)
3 (27) 3.0 (.79) 20 (177) 12 (3.2)
20 bar (300 psi)
diff. Case Flow 15 (133) 150 bar (2200 psi) 9 (2.4)
2 (18) 2.0 (.53) Input Torque
11 bar (160 psi)
diff.Case Flow 10 (88) 6 (1.6)
1 (9) 1.0 (.26) 150 bar (2200 psi) Case Flow
5 (44) 3 (0.8)
0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)

20 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM057 Typical Noise Levels


Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
82

78 2500 r/min
Max. Flow 2500 r/min
74 Min. Flow
Noise Level – dBA

70

66

62
600 r/min
Max. Flow
58
600 r/min
Min. Flow
54

50
0 50 100 150 200 250 300
(Sound pressure (700) (1500) (2200) (2900) (3600) (4400)
data equivalent to NFPA) Outlet Pressure – bar (psi)

Overall Efficiency Versus Speed


at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
95
50 bar
(700 psi)
90
100 bar
(1500 psi)
150 bar
Efficiency – %

85
(2200 psi)
200 bar
80 (2900psi)

75
250 bar
(3600 psi)
70
280 bar
(4000 psi)
65
0 500 1000 1500 2000 2500
Speed – r/min

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 21
Performance

PVM057 Delivery and Case Flow Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
150 (40)
140 (37)
50 bar (700 psi),
130 (34) Delivery
120 (32)
110 (29)
100 (26)
90 (24) 280 bar (4000 psi),
80 (21) Delivery

Case Flow – l/min (USgpm)


70 (18)
60 (16) 280 bar (4000 psi), 6,0 (1.6)
Case flow
50 (13) 5,0 (1.3)
40 (11) 4,0 (1.1)
30 (8) 3,0 (0.8)
20 (5) 50 bar (700 psi), 2,0 (0.5)
Case flow
10 (3) 1,0 (0.3)
0 0
0 500 1000 1500 2000 2500
Speed – r/min

Input Torque Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
320 (2832)
300 (2655) 320 bar
(4600 psi)
280 (2478)
Input Torque – Nm (in.lb.)

260 (1858) 280 bar


(4000 psi)
240 (2124)
250 bar
220 (1947) (3600 psi)
200 (1770)
200 bar
180 (1593) (2900 psi)
160 (1416)
150 bar
140 (1239) (2200 psi)
120 (1062)
100 (885) 100 bar
(1500 psi)
80 (708)
60 (531) 50 bar
(700 psi)
40 (354)
20 (177) 17 bar
(250 psi)
0
0 500 1000 1500 2000 2500 3000
Speed – r/min
22 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM057 Input Power Versus Speed


93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
Input Power @ Full Flow – kW (hp)

78 (105) 320 (4600)


72 (97)
280 (4000)
66 (89)
60 (80) 250 (3600)

Pressure – bar (psi)


54 (72)
200 (2900)
48 (64)
42 (56)
150 (2200)
36 (48)
30 (40)
100 (1500)
24 (32)
18 (24)
50 (700)
12 (16)
6 (8) 17 (250)
0
0 500 1000 1500 2000 2500
Speed – r/min
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
Input Torque – Nm (in.lb.)

Case Flow – l/min (USgpm)


6 (53)
20 bar (300 psi)
5 (44) differential,
11 bar (160 psi) Input Torque
4 (35) differential, 8.0 (2.11)
Input Torque
3 (27) 6.0 (1.58)
2 (18) 4.0 (1.06)
1 (9) 11 bar (160 psi) differential, Case Flow 2.0 (0.53)
20 bar (300 psi) differential, Case Flow
0 0
0 500 1000 1500 2000 2500
Speed – r/min
Input Torque and Case Flow Versus Speed
@ 93°C (200°F), cut-off and 1.0 bar absolute (0 psi gauge) inlet
100 (885)
Input Torque – Nm (in.lb.)

90 (796) 280 bar (4000 psi)


Case Flow – l/min (USgpm)

80 (708) Input Torque


70 (619)
280 bar
60 (531)
(4000 psi)
50 (442) Case Flow 10 (2.6)
40 (354) 8 (2.1)
30 (265) 150 bar (2200 psi), Case Flow 6 (1.6)
20 (177) 4 (1.1)
150 bar (2200 psi), Input Torque
10 (88) 2 (0.5)
0 500 1000 1500 2000 2500
Speed – r/min

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 23
Performance

PVM063 Typical Noise Levels at 2500 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
85
2500 r/min
min. flow
80
2500 r/min
max. flow
Noise Level – dBA

75

70

65
600 r/min
max. flow
60
600 r/min
55 min. flow

50
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)

Overall Efficiency versus Speed Delivery and Case Flow versus Speed at 93°C (200°F),
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet Full Flow 1.0 bar absolute (0 psi gauge) Inlet

160 (42)
100
95 140 (37)
50 bar (725 psi)
50 bar (725 psi)
90 120 (32) Delivery
Delivery – l/min (USgpm)

100 bar
85 (1450 psi) 100 (26)
Overall Efficiency (%)

Case Flow – l/min (USgpm)

80 210 bar (3000 psi)


80 (21) Delivery
75 150 bar
(2200 psi) 60 (16) 8 (2.11)
70
65 6 (1.59)
230 bar (3300 psi) 40 (11)
210 bar (3000 psi) Case Flow
60 210 bar 4 (1.06)
(3000 psi) 20 (5)
50 bar (725 psi) Case Flow 2 (0.53)
55
0
50
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed – r/min Speed (r/min)

24 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM063

Input Torque versus Speed at 93°C (200°F), Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet Full Flow and 1.0 bar absolute (0 psi gauge) Inlet

300 (2655) 100 (134)

90 (121)
250 (2212) 80 (107)
230 bar (3300 psi)
Input Torque – Nm (in.lb.)

210 bar (3000 psi) 230 bar (3300 psi)

Input Power – kW (hp)


70 (94) 210 bar (3000 psi)
200 (1770)
60 (80)
150 bar (2200 psi)
150 (1327) 50 (67)
150 bar (2200 psi)
40 (54)
100 bar (1500 psi)
100 (885)
30 (40) 100 bar (1500 psi)
50 bar (725 psi) 20 (27)
50 (442) 50 bar (725 psi)
17 bar (250 psi) 10 (13)
17 bar (250 psi)
0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)

Input Torque and Case Flow versus Speed Input Torque and Case Flow versus Speed
at 93°C (200°F), Load Sense Standby and at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar
1.0 bar absolute (0 psi gauge) Inlet absolute (0 psi gauge) Inlet
8 (71) 20.0 (5.28) 80 (708) 20.0 (5.28)
18.0 (4.76) 210 bar (3000 psi) Input Torque 18.0 (4.76)
7 (62) 70 (619)
16.0 (4.23) 16.0 (4.23)
Case Flow – l/min (USgpm)

20 bar (300 psi) 210 bar (3000 psi) Case Flow Case Flow – l/min (USgpm)
Input Torque – Nm (in.lb.)

6 (53) 60 (531)
diff. Input Torque
Input Torque – Nm (in.lb.)

14.0 (3.70) 14.0 (3.70)


5 (44) 50 (442)
12.0 (3.17) 12.0 (3.17)
150 bar (2200 psi)
40 (354)
4 (35) 11 bar (160 psi) diff. 10.0 (2.64) Case Flow 10.0 (2.64)
Input Torque
8.0 (2.11) 30 (265) 8.0 (2.11)
3 (27)
20 bar (300 psi) 6.0 (1.59)
diff. Case Flow 6.0 (1.59)
2 (18) 20 (177)
4.0 (1.06) 150 bar (2200 psi) Input Torque 4.0 (1.06)
11 bar (160 psi) diff.
1 (9) Case Flow 10 (88)
2.0 (.53) 2.0 (.53)
0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 25
Performance

PVM074 Typical Noise Levels


Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
(Sound pressure data equivalent to NFPA)
84

80
2400 r/min
Min. Flow
76
2400 r/min
72 Max. Flow
Noise Level – dBA

68
600 r/min
64
Min. Flow
60 600 r/min
Max. Flow
56

52
0 50 100 150 200 250 300
(700) (1500) (2200) (2900) (3600) (4400)
Outlet Pressure – bar (psi)

Overall Efficiency Versus Speed


at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
95

90
50 bar
(700 psi)
85 100 bar
Efficiency – %

(1500 psi)
80 150 bar
(2200 psi)
200 bar
75 (2900psi)
250 bar
70 (3600 psi)
280 bar
(4000 psi)
65
320 bar
(4600 psi)
60
0 500 1000 1500 2000 2500
Speed – r/min

26 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM074 Delivery and Case Flow Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
180 (48)
Delivery – l/min (USgpm)

160 (42) 50 bar (700 psi),


Delivery

Case Flow – l/min (USgpm)


140 (37)
120 (32)
280 bar (4000 psi),
100 (26) Delivery
80 (21) 8 (2.1)
60 (16) 280 bar (4000 psi), Case flow 6 (1.6)
40 (11) 4 (1.1)
20 (5) 50 bar (700 psi), Case flow
2 (0.5)
0 0
0 500 1000 1500 2000 2500
Speed – r/min

Input Torque Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
400 (3540)
Input Torque – Nm (in.lb.)

320 bar (4600 psi)


350 (3097)

Pressure – bar (psi)


280 bar (4000 psi)
300 (2655)
250 bar (3600 psi)
250 (2212)
200 bar (2900 psi)
200 (1770)
150 (1327) 150 bar (2200 psi)
100 bar (1500 psi)
100 (885)
50 bar (700 psi)
50 (442)
17 bar (250 psi)
0
0 500 1000 1500 2000 2500
Speed – r/min

Input Power Versus Speed


Input Power @ Full Flow – kW (hp)

93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet


100 (134)
320 (4600)
90 (121)
Pressure – bar (psi)

80 (107) 280 (4000)


70 (94) 250 (3600)
60 (80) 200 (2900)
50 (67)
150 (2200)
40 (54)
30 (40) 100 (1500)
20 (27) 50 (700)
10 (13)
17 (250)
0
0 500 1000 1500 2000 2500
Speed – r/min

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 27
Performance

PVM074 Input Torque and Case Flow Versus Speed


@ 93°C (200°F), load sense standby and 1.0 bar absolute (0 psi gauge) inlet
7 (62)
20 bar (300 psi) differential,
Input Torque
6 (53)
Input Torque – Nm (in.lb.)

5 (44)

Case Flow – l/min (USgpm)


4 (35) 11 bar (160) differential 8.0 (2.11)
Input Torque
3 (27) 6.0 (1.58)
20 bar (300 psi) differential
2 (18) Case Flow
4.0 (1.06)

1 (9) 2.0 (0.53)


11 bar (160 psi) differential
Case Flow
0 0
0 500 1000 1500 2000 2500
Speed – r/min

Input Torque and Case Flow Versus Speed


@ 93°C (200°F), cut-off and 1.0 bar absolute (0 psi gauge) inlet
160 (1416)
280 bar (4000 psi),
140 (1239) Input Torque

120 (1062)
Input Torque – Nm (in.lb.)

100 (885)
Case Flow – l/min (USgpm)

80 (708)
150 bar (2200 psi),
Input Torque
60 (531) 30 (7.9)
280 bar (4000 psi), Case Flow
40 (354) 20 (5.3)

20 (177) 10 (2.6)
150 bar (2200 psi), Case Flow
0 0
0 500 1000 1500 2000 2500
Speed – r/min
28 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM081 Typical Noise Levels at 2400 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
82
2400 r/min
max. flow
78
2400 r/min
min. flow
Noise Level – dBA

74

70

66
600 r/min
max. flow
62 600 r/min
min. flow

58

54
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)

Overall Efficiency versus Speed Delivery and Case Flow versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet at 93°C (200°F), Full Flow 1.0 bar absolute (0 psi gauge) Inlet

100 100 bar 200 (53)


150 bar (1450 psi) 50 bar (725 psi)
95 (2200 psi) 180 (48)
160 (42)
90
140 (37) 50 bar (725
Delivery – l/min (USgpm)

85
Overall Efficiency (%)

psi) Delivery
80 120 (32) 210 bar (3000 Case Flow
230 bar (3300 psi) psi) Delivery l/min
75 100 (26) (USgpm)
70 200 bar 80 (21) 210 bar (3000 psi) Case Flow 8 (2.11)
(2900 psi)
65 60 (16) 6 (1.59)
60 4 (1.06)
40 (11)
55 50 bar (725 psi) Case Flow 2 (0.53)
20 (5)
50 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed – r/min Speed (r/min)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 29
Performance

PVM081

Input Torque versus Speed at 93°C (200°F), Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet Full Flow and 1.0 bar absolute (0 psi gauge) Inlet

350 (2655) 100 (134)

300 (2655) 230 bar (3300 psi) 90 (121)


80 (107)
Input Torque – Nm (in.lb.)

250 (2212) 210 bar (3000 psi) 230 bar (3300 psi)

Input Power – kW (hp)


70 (94)
200 bar (2900 psi)
200 (1770) 150 bar (2200 psi) 60 (80)
50 (67) 150 bar (2200 psi)
150 (1327)
100 bar (1500 psi) 40 (54)
100 bar (1500 psi)
100 (885) 30 (40)

50 bar (725 psi) 20 (27) 50 bar (725 psi)


50 (442)
17 bar (250 psi) 10 (13) 17 bar (250 psi)
0
0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)

Input Torque and Case Flow versus Speed at 93°C Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet (0 psi gauge) Inlet

9 (80)
80 (708) Case Flow – l/min (USgpm)
20 bar (300 psi) 70 (619)
8 (71) diff. Input Torque 210 bar (3000 psi) Input Torque
Input Torque – Nm (in.lb.)

150 bar
Input Torque – Nm (in.lb.)

7 (62) 60 (531) (2200 psi)


11 bar (160 psi) diff. Input
6 (53) Input Torque Case 50 (442) Torque
Flow l/min
5 (44) (USgpm)
40 (354)
210 bar
4 (35) 10.0 (2.64) (3000 psi)
30 (265) Case 8.0 (2.11)
20 bar (300 psi) 8.0 (2.11) Flow
3 (27) 6.0 (1.59)
diff. Case Flow 20 (177)
2 (18) 6.0 (1.59)
11 bar (160 psi) diff. 150 bar 4.0 (1.06)
Case Flow 4.0 (1.06) 10 (88) (2200 psi)
1 (9) 2.0 (.53)
Case Flow
2.0 (0.53)
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)

30 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM098 Typical Noise Levels at 2000 and 600 r/min


with petroleum oil (10 W) @ 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) inlet
86
84 2000 r/min
Min. flow
82
2000 r/min
80 Max. flow
Noise Level – dBA

78
76
74
600 r/min
72 Max. flow
70 600 r/min
Min. flow
68
66
64
0 50 100 150 200 250 300
Sound pressure (700) (1500) (2200) (2900) (3600) (4400)
data equivalent to NFP Outlet Pressure – bar (psi)

Overall Efficiency Versus Speed


@ 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
95

90
Overall Efficiency (%)

85 100 bar (1500 psi)


150 bar (2200 psi)
50 bar (700 psi)
80 200 bar (2900 psi)

250 bar (3600 psi)


75
280 bar (4000 psi)

320 bar (4600 psi)


70
0 500 1000 1500 2000 2500
Speed – r/min

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 31
Performance

PVM098 Delivery and Case Flow Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
220 (58)

200 (53) 50 bar (700 psi),


Delivery
180 (48)
Delivery – l/min (USgpm)

160 (42)

140 (37) 280 bar (4000 psi),


Delivery
120 (32)

Case Flow – l/min (USgpm)


100 (26)
280 bar (4000 psi),
80 (21) Case flow 8 (2.1)
60 (16) 6 (1.6)
40 (11) 50 bar (700 psi), 4 (1.1)
Case flow
20 (5) 2 (0.5)
0 0
0 500 1000 1500 2000 2500
Speed – r/min

Input Torque Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
600 (5310)

540 (4779)
320 bar (4600 psi)
480 (4248)
Input Torque – Nm (in.lb.)

280 bar (4000 psi)


420 (3717)
250 bar (3600 psi)
360 (3186)
200 bar (2900 psi)
300 (2655)
240 (2124) 150 bar (2200 psi)

180 (1593) 100 bar (1500 psi)

120 (1062)
50 bar (700 psi)
60 (531)
17 bar (250 psi)
0
500 1000 1500 2000 2500 3000
Speed – r/min

32 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM098 Input Power Versus Speed


@93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
130 (174)
120 (161) 320 bar (4600 psi)
110 (148)
100 (134) 280 bar (4000 psi)
Input Power – KW (hp)

250 bar (3600 psi)


90 (121)
80 (107)
200 bar (2900 psi)
70 (94)
60 (80)
150 bar (2200 psi)
50 (67)
40 (54) 100 bar (1500 psi)
30 (40)
20 (27) 50 bar (700 psi)
10 (13) 17 bar (250 psi)
0
500 1000 1500 2000 2500 3000
Speed – r/min

Input Torque and Case Flow Versus Speed


@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
11 (77)
10 (88) 20 bar (300) differential
Input Torque
9 (80)
Input Torque – Nm (in.lb.)

8 (71) 9.0 (2.38) Case Flow (l/min (USgpm)

7 (62) 11 bar (160) differential 8.5 (2.25)


Input Torque
6 (53) 8.0 (2.11)
5 (44) 20 bar (300) differential 7.5 (1.98)
Case Flow
4 (35) 7.0 (1.85)
3 (27) 6.5 (1.72)
11 bar (160) differential
2 (18) Case Flow 6.0 (1.59)
1 (9) 5.5 (1.45)
0 500 1000 1500 2000 2500
Speed – r/min

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 33
Performance

PVM098 Input Torque and Case Flow Versus Speed


@ 93°C (200°F), cut-off and 1.0 bar absolute (0 psi gauge) inlet
240 (2124)
220 (1947) 280 bar (4000 psi)
Input Torque
Input Torque – Nm (lb.in.)

200 (1770)
180 (1593)

Case Flow – l/min (USgpm)


160 (1416)
140 (1239)
120 (1062) 280 bar (4000 psi) 30 (7.9)
100 (885) Case Flow
25 (6.6)
80 (708) 20 (5.3)
60 (531) 150 bar (2200 psi) 150 bar (2200 psi), Case Flow 15 (4.0)
Input Torque
40 (354) 10 (2.6)
20 (177) 5 (1.3)
0 500 1000 1500 2000 2500
Speed – r/min

Case Flow at 2200 r/min, Full Flow


93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
Case Flow – l/min (USgpm)

16 (4.2)
14 (3.7)
12 (3.2)
10 (2.6)
8 (2.1)
6 (1.6)
4 (1.0)
2 (0.5)
0
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Case Flow – l/min (USgpm)

Case Flow at 2200 r/min, Minimum Flow


935C (2005F), 1.0 bar absolute (0 psi gauge) Inlet
32 (8.4)
28 (7.4)
24 (6.3)
20 (5.3)
16 (4.2)
12 (3.2)
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)

34 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM106 Typical Noise Levels at 2200 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
86

82
2200 r/min
max. flow 2200 r/min
78 min. flow
Noise Level – dBA

74

70
600 r/min
min. flow
66
600 r/min
62 max. flow

58

54
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)

Overall Efficiency versus Speed at Delivery and Case Flow versus Speed at 93°C (200°F),
93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet Full Flow 1.0 bar absolute (0 psi gauge) Inlet
240 (63)
100 220 (58)
100 bar 50 bar (725
95 150 bar (1450 psi) 200 (53) psi) Delivery
(2200 psi) 180 (48)
90
Delivery – l/min (USgpm)

160 (42)
Overall Efficiency (%)

85 200 bar 210 bar (3000 Case Flow


(2900 psi) 140 (37) psi) Delivery l/min
80 50 bar (725 psi) (USgpm)
230 bar (3300 psi) 120 (32)
75
210 bar 100 (26) 10 (2.6)
70 (3000 psi)
65 80 (21) 8 (2.11)

60 60 (16) 210 bar (3000 psi) Case Flow 6 (1.59)

55 40 (11) 4 (1.06)
50 bar (725 psi) Case Flow 2 (0.53)
20 (5)
50
0 500 1000 1500 2000 2500 3000 0
0 500 1000 1500 2000 2500
Speed – r/min Speed (r/min)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 35
Performance

PVM106

Input Torque versus Speed at 93°C (200°F), Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
450 (3982) 100 (134)
230 bar (3300 psi) 230 bar (3300 psi)
400 (3540)
90 (121) 210 bar (3000 psi)
210 bar (3000 psi)
150 bar (2200 psi)
Input Torque – Nm (in.lb.)

Input Power – kW (hp)


350 (3097) 200 bar (2900 psi) 80 (107)
300 (2655) 70 (94)
150 bar (2200 psi) 100 bar (1500 psi)
60 (80)
250 (2212)
50 (67)
200 (1770)
100 bar (1500 psi) 40 (54)
150 (1327) 30 (40)
50 bar (725 psi)
100 (885) 50 bar (725 psi) 20 (27)
10 (13) 17 bar (250 psi)
50 (442)
17 bar (250 psi)
0
0 0 500 1000 1500 2000 2500 3000
0 500 1000 1500 2000 2500 3000
Speed (r/min)
Speed (r/min)

Input Torque and Case Flow versus Speed at 93°C Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet (0 psi gauge) Inlet

12 (106) 140 (1239)


130 (1150)
11 (97) 210 bar (3000 psi) Input Torque
20 bar (300 psi) 120 (1062)
10 (88) diff. Input Torque 110 (973)
(Input Torque – Nm (in.lb.)
Input Torque – Nm (in.lb.)

9 (80)
100 (885)
8 (71) Case Case
Flow l/min 90 (796)
11 bar (160 psi) diff. Flow l/min
7 (62) (USgpm) 80 (708) 150 bar (2200 psi)
Input Torque (USgpm)
Input Torque
6 (53) 9.0 (2.38) 70 (619)
5 (44) 60 (531) 30 (7.9)
8.5 (2.25)
4 (35) 50 (442) 25 (6.6)
8.0 (2.11) 210 bar (3000 psi) Case Flow
3 (27) 20 bar (300 psi) 40 (354) 20 (5.3)
7.5 (1.98)
diff. Case Flow 11 bar (160 psi) diff. 30 (265) 15 (4.0)
2 (18) Case Flow 7.0 (1.85) 150 bar (2200 psi)
20 (177) Case Flow 10 (2.6)
1 (9) 6.5 (1.72)
10 (88) 5 (1.3)
6.0 (1.59)
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
Speed (r/min) Speed (r/min)

36 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM131 Typical Noise Levels at 2000 and 600 r/min


with petroleum oil (10 W) @ 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) inlet
84
2000 r/min
82 Max. flow
80
78
76 2000 r/min
Noise Level – dBA

600 r/min
74 Min. flow Min. flow
72
70
68
66
600 r/min
64 Max. flow
62
60
58
0 50 100 150 200 250 300
(700) (1500) (2200) (2900) (3600) (4400)
Sound pressure data Outlet Pressure – bar (psi)
equivalent to NFPA

Overall Efficiency Versus Speed


@ 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
95

90

100 bar (1500 psi)


Overall Efficiency (%)

85 150 bar (2200 psi) 50 bar (700 psi)

80
200 bar (2900 psi)

75
250 bar (3600 psi)

70 280 bar (4000 psi)

320 bar (4600 psi)


65
0 500 1000 1500 2000 2500
Speed – r/min

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 37
Performance

PVM131 Delivery and Case Flow Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
260 (69)
240 (63) 50 bar (700 psi),
Delivery
220 (58)
Delivery – l/min (USgpm)

200 (53)
180 (48) 280 bar (4000 psi),
Delivery
160 (42)

Case Flow – l/min (USgpm)


140 (37)
120 (32)
100 (26) 20 (5.3)
280 bar (4000 psi),
80 (21) Case flow 16 (4.2)
60 (16) 12 (3.2)
40 (11) 6 (2.1)
20 (5) 50 bar (700 psi), Case flow 4 (1.1)
0
0 500 1000 1500 2000 2500
Speed – r/min

Input Torque Versus Speed


@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
800 (7080)

700 (6195)
320 bar (4600 psi)
600 (5310)
Input Torque – Nm (in.lb.)

280 bar (4000 psi)


500 (4425) 250 bar (3600 psi)

400 (3540) 200 bar (2900 psi)

300 (2655) 150 bar (2200 psi)

200 (1770) 100 bar (1500 psi)

100 (885) 50 bar (700 psi)


17 bar (250 psi)
0
0 500 1000 1500 2000 2500
Speed – r/min

38 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM131 Input Power Versus Speed


@93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
140 (188)
320 bar (4600 psi)
130 (174)
120 (161) 280 bar (4000 psi)
250 bar (3600 psi)
Input Power – kW (hp)

110 (148)
100 (134)
90 (121) 200 bar (2900 psi)
80 (107)
70 (94) 150 bar (2200 psi)
60 (80)
50 (67)
100 bar (1500 psi)
40 (54)
30 (40)
50 bar (700 psi)
20 (27)
10 (13) 17 bar (250 psi)
0
0 500 1000 1500 2000 2500
Speed – r/min

Input Torque and Case Flow Versus Speed


@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
18 (159)

16 (142) 20 bar (300 psi)


differential,
Input Torque – Nm (in.lb.)

14 (124) Input Torque

12 (106)
11 bar (160 psi)
differential,
10 (88) Input Torque
Case Flow (l/min (USgpm)

8 (71) 7 (1.85)

6 (53) 20 bar (300 psi) differential 6 (1.58)


Case Flow
4 (35) 5 (1.32)

2 (18) 11 bar (160 psi) differential 4 (1.06)


Case Flow
0 3 (0.79)
0 500 1000 1500 2000 2500
Speed – r/min

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 39
Performance

PVM131 Input Torque and Case Flow Versus Speed


@ 93°C (200°F), cut-off and 1.0 bar absolute (0 psi gauge) inlet
260 (2301)
240 (2124) 280 bar (4000 psi)
Input Torque
Input Torque – Nm (in.lb.)

220 (1947)
200 (1770)
180 (1593)

Case Flow – l/min (USgpm)


160 (1416)
140 (1239) 56 (14.8)
120 (1062) 48 (12.7)
150 bar (2200 psi)
100 (885) Input Torque 40 (10.6)
80 (708) 32 (8.5)
280 bar (4000 psi), Case Flow
60 (531) 24 (6.3)
40 (354) 16 (4.2)
150 bar (2200 psi), Case Flow
20 (177) 8 (2.1)
0 500 1000 1500 2000 2500
Speed – r/min
Case Flow at 2000 r/min, Full Flow
93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
Case Flow – l/min (USgpm)

18 (4.7)
16 (4.2)
14 (3.7)
12 (3.2)
10 (2.6)
8 (2.1)
6 (1.6)
4 (1.0)
2 (0.5)
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Case Flow – l/min (USgpm)

Case Flow at 2000 r/min, Minimum Flow


93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
28 (7.4)
24 (6.3)
20 (5.3)
16 (4.2)
12 (3.2)
8 (2.1)
4 (1.0)
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)

40 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance

PVM141 Typical Noise Levels at 2000 and 1000 r/min with Petroleum Oil
(10W) at 93°C (200°F), and 1.0 bar absolute (0 psi gauge) Inlet

88
86
84 2000 r/min
min. flow
82
Noise Level – dBA

80
2000 r/min
78 max. flow
76
74 1000 r/min
min. flow
72
70
1000 r/min
68 max. flow
66
64
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)

Overall Efficiency versus Speed at 93°C (200°F), Delivery and Case Flow versus Speed at
and 1.0 bar absolute (0 psi gauge) Inlet 93°C (200°F), Full Flow and 1.0 bar absolute
(0 psi gauge) Inlet
100 280 (74)
95 260 (69)
240 (63) 100 bar
90 100 bar (1500 psi)
Delivery – l/min (USgpm)

220 (58) (1500 psi)


150 bar (2200 psi) Delivery
Overall Efficiency (%)

85 200 (53)
50 bar 210 bar (3000
80 210 bar (3000 psi) (700 psi) 180 (48) psi) Delivery
230 bar (3300 psi) 160 (42)
75 Case
140 (37) Flow
70 l/min
120 (32) (USgpm)
65 210 bar (3000 10 (2.6)
100 (26)
psi) Case Flow
60 80 (21) 8 (2.1)
60 (16) 6 (1.6)
55
40 (11) 4 (1.1)
50 20 (5) 2 (0.5)
100 bar (1500 psi) Case Flow
0
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
Speed (r/min) Speed (r/min)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 41
Performance

PVM141

Input Torque versus Speed at 93°C (200°F), Input Power versus Speed, 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet and 1.0 bar absolute (0 psi gauge) Inlet
600 (5310) 120 (161)
230 bar
550 (4867) 110 (148) (3300 psi)
230 bar (3300 psi)
500 (4425) 210 bar
210 bar (3000 psi) 100 (134) (3000 psi)
Input Torque – Nm (in.lb.)

450 (3982) 90 (121)

Input Power – kW (hp)


400 (3540) 80 (107) 150 bar
350 (2655) 150 bar (2200 psi) (2200 psi)
70 (94)
300 (2655) 60 (80)
250 (2212) 100 bar
100 bar (1500 psi) 50 (67) (1500 psi)
200 (1770) 40 (54)
150 (1327) 30 (40) 50 bar
(700 psi)
100 (885)
50 bar (725 psi) 20 (27)
50 (442) 17 bar (250 psi) 17 bar
10 (13) (250 psi)
0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500
Speed (r/min) Speed (r/min)

Input Torque and Case Flow versus Speed at 93°C Input Torque and Case Flow versus Speed
(200°F), Load Sense Standby and 1.0 bar absolute at 93°C (200°F), Pressure Limit Cut-Off and
(0 psi gauge) Inlet 1.0 bar absolute (0 psi gauge) Inlet

14 (124) 110 (973)


13 (115) 100 (885)
12 (106) 20 bar (290 psi)
diff. Input Torque 90 (796)
Input Torque – Nm (in.lb.)

11 (97) 210 bar (3000 psi)


Input Torque – Nm (in.lb.)

10 (89) 11 bar (160 psi) 80 (708) Input Torque


diff. Input Torque Case 150 bar (2200 psi)
9 (80) Flow l/min 70 (619)
Input Torque
8 (71) (USgpm) 60 (531) Case Flow
7 (62) 6.5 (1.72) l/min
20 bar (290 psi) 50 (442) (USgpm)
6 (53) 6.0 (1.58)
diff. Case Flow
5 (44) 5.5 (1.45) 40 (354) 20 (5.3)
4 (35) 5.0 (1.32) 210 bar (3000 psi)
30 (265) Case Flow 15 (2.6)
3 (27) 4.5 (1.19)
11 bar (160 psi) 20 (177) 150 bar (2200 psi) 10 (4.0)
2 (18) 4.0 (1.06)
diff. Case Flow Case Flow
1 (9) 3.5 (0.92) 10 (88) 5 (1.3)
3.0 (0.79) 0
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
Speed (r/min) Speed (r/min)

42 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
End-ported
Models

PVM018/020

Dimensions in millimeters (inches) Alt. drain port “F”


Drain port “F” (See options on page 83.)
(See options on page 82.) 131,5
(5.18)
Start on page 78 for shaft options
Load sense port “J”
(See options on page 83.)

72,0 58,0
(2.83) (2.28)

72,0 58,0
(2.28) 73,0 76,0
(2.83) (2.87) (2.99)

“A” mount “B” mount


33,6 26,1
(1.32) (1.03)

Control position for right hand (clockwise) shaft


rotation, as viewed from shaft end. Position for
left hand rotation is shown on following page. 228,9 (9.00) with Adjustable maximum displacement
adj. max. stop stop (1 turn = 1.1 cm3/rev)
CCW to reduce displacement.
219,8 (8.65) without
adj. max. stop 37,4
(1.47)

165,7
(6.52)

85,1
(3.35)
E Inlet gauge
port “K.”
See options
55,2 on page 83.
(2.17)
23,0 Inlet port “B.”
(.91) See options
on page 82.
D ∅A 106,5 34,5 34,0
C (4.19) (1.36) (1.34)
Drain port
166,7 “F.” See
65,2 65,2 (6.56)
(2.57) (2.57) options on Outlet port “C.”
200,7 page 83. See options on page 82.
(7.90)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 43
End-ported
Models

PVM018/020

Dimensions in millimeters (inches)

37,4
(1.47)

Control position for right hand


rotation (Load sensing control
shown)
Adjustable maximum displacement stop
(1 turn = 1.1 cm3/rev) CCW to destroke
165,7
(6.52)

Inlet position for right hand rotation (Position


for left hand rotation shown below) Outlet

34,5 34,0
(1.36) (1.34)
Inlet/Outlet Ports and Control Positioned
for Right Hand Rotation

Control position for left hand rotation 37,5


(1.48)
(Pressure compensated control shown)

140,5
(5.53)
126,3
(4.97)

Inlet position for left hand


rotation (Position for right
hand rotation shown above)
Outlet

Inlet/Outlet Ports and Control Positioned


for Left Hand Rotation

44 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Side-ported
Models

PVM018/020

Dimensions in millimeters (inches)


Load sense port “J” 171,7
(See options on page 83.) (6.76)
131,5 Outlet port “C.”
Alt. drain port “F” See options on page 82.
(5.18)
(See options on page 83.)
Drain port “F”
(See options on page 83.)
Start on page 78 for shaft options

72,0 171,7
(2.83) (6.76)
to pilot
mtg. flg. 194,1
(7.64)
72,0 58,0
(2.83) (2.28)

“A” mount “B” mount Adjustable maximum displacement


33,6 26,1 stop (1 turn = 1.1 cm3/rev) Turn Outlet port “C.” (above)
(1.32) (1.03) CCW to reduce displacement. See options on page 82.
Control position for right hand 228,9 (9.00)
(clockwise) shaft rotation , as viewed with adj. max. stop Inlet port “B.”
from shaft end. Position for left hand See options on page 82.
rotation is shown on following page. 219,8 (8.65) without
adj. max. stop 114,7
(4.52)

108,8
(4.28)
85,1
(3.35)
E
Outlet
gauge
port “K.”
55,2 See options
(2.17)
∅A 23,0 Inlet gauge on page 83.
(.91) port “K.”
106,5 See options
D (4.19)
on page 83. 21,9 21,6
C Alt. drain port “F.” 175,2 (.86) (.85)
See options on (6.90)
65,2 65,2 page 83. 62,9 62,9
205,6 (2.48) (2.48)
(2.57) (2.57) (8.09)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 45
Side-ported
Models

PVM018/020

Dimensions in millimeters (inches)


114,7
(4.52)
Control position for right hand
Adjustable maximum displacement stop rotation (Load sensing control
(1 turn = 1.1 cm3/rev) Turn CCW to destroke shown)

Inlet position for right hand rotation (Position


for left hand rotation shown below) Outlet gauge port “K.”
See options on page 83.

Outlet

Inlet gauge port “K.” See options


on page 83.
21,9 21,6
(.86) (.85)
62,9 62,9
(2.48) (2.48)
Inlet/Outlet Ports and Control Positioned
for Right Hand Rotation

86,5
(3.41)
72,3
(2.85)
Control position for left hand rotation
(Pressure compensated control shown)

Inlet gauge port “K.”


Outlet gauge port “K.” See options
See options on page 83.
on page 83.

Inlet position for left hand


rotation (Position for right
hand rotation shown above)
Outlet

Inlet/Outlet Ports and Control Positioned


for Left Hand Rotation

46 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models

PVM018/020

Dimensions in millimeters (inches)


Load sense port “J” Centerline of
(See options on page 83) outlet port
164,2
Alt. drain port “F” (6.46)
124,0 Outlet port “C.”
(See options on page 83) (4.88) See options on page 82.
Drain port “F”
(See options on page 83)
Start on page 78 for shaft options

72,0
(2.83)
to pilot 164,2
mtg. flg. (6.46)
58,0
72,0 (2.28)
(2.83)
Adjustable maximum displacement
stop (1 turn = 1,1 cm3/rev) Turn
26,1 CCW to reduce displacement.
(1.03)
Control postiion for right hand Inlet port “B.”
(clockwise) shaft rotation, as viewed 221,4 (8.72) with See options on page 82.
from shaft end. Position for left hand adj. max. stop
rotation is shown on following page. 212,3 (8.36) without 114,7
adj. max. stop (4.52)

108,1
(4.14)
∅A 85,1
B (3.35) 23,0
(.91)

60,0
(2.36)

99,0
D (3.90)
C 167,7 62,9 64,2
(6.60) (2.48) (2.53)
87,0 87,0
(3.43) (3.43) 223,2 Alt. drain port “F.”
(8.79) See options on page 83.

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 47
Thru-drive
Models

PVM018/020
Model Code Position 25
Dimensions in millimeters (inches) Description
114,7
Adjustable maximum displacement (4.52) A For SAE “A” pad with a 9T,
stop (1 turn = 1.1 cm3/rev). 16/32 DP, 30° pressure
angle, involute spline
Turn CCW to reduce displacement.
Control position for B For SAE “A” pad with a 11T,
right hand rotation 16/32 DP, 30° pressure
angle, involute spline
(Load sensing G For ISO 80 A2HW pad
Inlet position for right hand control shown) with a 9T, 16/32 DP,
30° pressure angle,
rotation (Position for left hand involute spline
rotation shown below) Outlet H For ISO 80 A2HW pad
with a 11T, 16/32 DP,
30° pressure angle,
involute spline

62,9 64,2
(2.48) (2.53)
Inlet/Outlet Ports and Control Positioned
for Right Hand Rotation
Control position for left hand rotation
(Pressure compensator control shown)
86,5
Output shaft 21T, 32/64 DP, (3.41)
30° press. angle involute spline. 72,3
57,49 (2.85)
(2.26)
40,46 12,25
(1.59) (0.48)
∅27,00
(1.06)
79,4
(3.13) K (2 places)

Inlet position for left hand


∅G rotation (Position for right
53,5 hand rotation shown above)
(2.11)
Outlet
89,70 (3.531)
∅ 89,60 (3.527)
N H H
159,2 2,00 (0.079)
(6.27) 1,90 (0.075) Inlet/Outlet Ports and Control Positioned
To mounting face for Left Hand Rotation
8,50
(0.33)

N Support attachment points


(2 places)

20,0 20,0
(0.79) (0.79)

48 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Flange
Designations

PVM018/020
“A” Pilot Flange Designation ∅A B C D E
SAE J744-82-2 Model Code A 82,55 (3.25) 8,00 (.315) 106,4 (4.19) 53,2 (2.09) 11,35/10,97 (.447/.432)
ISO 3019/2-80A2HW Model Code B 80,00 (3.15) 8,00 (.315) 109,0 (4.29) 54,5 (2.15) 11,27/11,00 (.444/.433)
“B” Pilot Flange Designation
SAE J744-101-2 Model Code C 101,60 (4.00) 8,00 (.315) 146,0 (5.750) 73,0 (2.875) 14,55/14,17 (.572/.557)
ISO 3019/2-100A2HW Model Code D 100,00 (3.937) 8,00 (.315) 140,0 (5.512) 70,0 (2.756) 14,27/14,00 (.562/.551)

Model Code Position 25 ∅G H K N


A, B 82,625 (3.253) .375-16 UNC-2Bthd. .375-16 UNC-2B thd.
53,2 (2.09)
82,575 (3.250) 0.75 deep min. 0.62 deep min.
G, H 80,046 (3.15) 54,5 (2.15) M10 thd. x 19,05 deep min. M10 thd. x 15,88 deep min.
80,002 (3.149)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 49
End-ported
Models

PVM045/050

Dimensions in millimeters (inches)

Drain port “F.” See Alternate drain port “F”


options on page 83.
Start on page 78 for shaft options Inlet gauge port “K”

80,0 28,0 (1.10) 80,0


(3.15) (3.20)
Adjustable maximum
displacement stop
(1 turn = 2 cm3/rev).
80,0 80,0 Turn CCW to reduce
(3.15) (3.20) displacement.

36,9 134,3 (5.29) max.


(1.45)

Load sensing control (See pressure


Control position for left hand (counterclockwise) shaft rotation, compensated control on following page)
as viewed from shaft end. Position for right hand rotation is
shown on following page.
Load sense port “J.”
257,0 (10.12) max. See options on page 82.
Alternate load sense port “J”
247,0 (9.72) Inlet port “B.” See
44,6
(1.75) 178,6 (7.03) 19,1 options on page 82.
(0.75)
B

E
130,6
(5.14)
42,0
(1.65)

∅A
D 135,4 (5.33) 53,0
47,8 (1.88) (2.09)
C 175,0 (6.89) 75,1 87,1
87,0 Alternate (2.96) (3.43)
(3.425) 212,0 (8.35) drain port “F”
174,0 Outlet gauge port “K.” Outlet port “C.” See
(6.85) See options on page 83. options on page 82.

50 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
End-ported
Models

PVM045/050

Dimensions in millimeters (inches)

34,4 (1.35) 121,8


(4.80)
98,9 (3.89) max.
4,0 (0.16) Control position for right hand
rotation (Pressure compensated
control shown)
Control position for left hand rotation
138,5
(5.45)
Non-maximum adjustment
stop control cap. See preceding page for
adjustable maximum displacement stop.
Outlet
Inlet position for right hand rotation. (Position
for left hand rotation shown below)
53,0 47,8
(2.09) (1.88)
87,1 75,1
(3.43) (2.96)

Inlet/Outlet Ports and Control Positioned


for Right Hand Rotation

Control position for


Control position for left hand rotation right hand rotation
(Load sensing control shown)

Inlet position for left hand


Outlet rotation. (Position for right
hand rotation shown above)

Inlet/Outlet Ports and Control Positioned


for Left Hand Rotation
Dimensions shown on preceding page.

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 51
Side-ported
Models

PVM045/050

Dimensions in millimeters (inches)


Adjustable max.
displacement stop
(1 turn = 2 Drain port “F.” See Inlet gauge
cm3/rev). Turn options on page 83. port “K”
CCW to reduce 36,9 Start on page Outlet gauge
80,0 displacement. (1.45) 78 for shaft port “K.”
(3.20) See options
options. on page 83.

134.3 57,50 (2.26) 50,0 (1.97)


(5.29)
max. 72,5 (2.85) 69,0 (2.72)
80,0
(3.20)
View Z-Z

Load sensing control (see pressure compensated


control on following page). Load sense port
“J.” See options Control position for right hand
Alternate load sense port “J” on page 83. (clockwise) shaft rotation, as viewed
257,0 from shaft end. Position for left hand
(10.12) rotation is shown on following page.
max. 247,0 (9.72) 44,6
(1.75)
178,6 19,1
(7.03) (0.75) Z
72,1 4.63 B
168,2 (2.84)
(6.62) 130,6
E
109,1 (5.14)
(4.30)
75,5 (2.97)

42.0
(1.65) ∅A Z
183,0 78,0 D 135,4
(7.20) (3.07) C (5.33) 42.0
208,0 87,0 (1.65)
(8.19) 191,6
230,0 (3.425) (7.54)
(9.06) 174,0
Outlet port “C.” See (6.850) Alternate drain port “F”
options on page 82. Alternate drain port “F” Inlet port “B.” See
options on page 82.

52 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Side-ported
Models

PVM045/050

Dimensions in millimeters (inches)

121,8 (4.80) max. 34,4 (1.35)


Control position for left hand 98,9 (3.89)
rotation (Pressure compensated 4,0 (0.16) Control position for right hand rotation
control shown). Inlet/outlet port (Inlet/outlet port positions for right hand
positions for left hand rotation rotation are shown on preceding page.)
are the opposite of those shown
Non-maximum adjustment stop control
for right hand rotation on 138,5
preceding page. cap. See preceding page for adjustable
(5.45) maximum displacement stop.

Outlet gauge port “K.” See Inlet gauge port “K”


options on page 83.

57,50 (2.26) 50,0 (1.97)


72,5 (2.85) 69,0 (2.72)

Inlet/Outlet Ports and Control Positioned


for Left Hand Rotation

Control position for left hand rotation


(Inlet/outlet port positions for left hand
rotation are the opposite of those
shown for right hand rotation on Control position for right hand rotation
preceding page.) (Load sensing control shown). Inlet/outlet
port positions for right hand rotation are
shown on preceding page.

Outlet gauge port “K.”


Inlet gauge port “K”
See options on page 83.

Inlet/Outlet Ports and Control Positioned


for Right Hand Rotation
Dimensions shown on preceding page.

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 53
Thru-drive
Models

PVM045/050

Dimensions in millimeters (inches)


Alt. drain port
“F.” See options 121,8 34,4
on page 83. (4.80) (1.35)
See shaft options
starting on page 78. 98,9 Control position
197,7 (3.89)
(7.78) for R.H. rotation
135,8
(5.35)
Outlet 138,5
port “C.” (5.45)
See 81,3
options on (3.20) 68,8
(2.71)
page 82.
183,0 81,3 72,3
(7.20) (3.20) (2.85)
208,0
(8.19)
9,5 Drain port “F.” Control position
View “A-A” (0.34) See options on page 83. for L.H. rotation
36,9
(1.45) Left Hand Rotation

133,3 34,1 Adjustable maximum displacement stop


(5.25) (1.34) (1 turn = 2.1 cm3/rev)
110,8 Load sense port “J.” See
(4.36) options on page 83. 249,0 Load sense
44,6
(1.76) (9.80) Load sense control control position
178,6 position for L.H. rotation for R.H. rotation
(7.03)
11,0
(0.43)
168,2
(6.62)
130,6 117,6
(5.14) (4.63)
A
D
∅A
78,6 42,0 (1.65)
(3.09)
A
Drain port “F.” See Inlet port “B.”
B Right Hand Rotation
options on page 83. See options on
191,6 page 82. 5,4
C (7.54) Outlet gauge port “K”
(0.21)
42,0
87,0 87,0 251,0 (1.65)
(3.43) (3.43) (9.88)

Right Hand Rotation with


Load Sensing Control and Tube Ports Inlet gauge port “K.”
See options on page 83.
35,0 36,0
(1.38) (1.42)

54 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models

PVM045/050
Model Code Position 25
Dimensions in millimeters (inches) Description
“A” Pad 61,74
(2.43) A For SAE “A” pad with a 9T,
16/32 DP, 30° pressure
42,44 angle, involute spline
(1.59) B For SAE “A” pad with a 11T,
10,03
(0.482) 16/32 DP, 30° pressure
angle, involute spline
C For SAE “B” pad with a 13T,
16/32 DP, 30° pressure
89,70 (3.531) angle, involute spline
∅G ∅ 89,60 (3.527)
D For SAE “B” pad with a 15T,
16/32 DP, 30° pressure
angle, involute spline
G For ISO 80-A2HW pad
∅ 31,75 N (2 places) with a 9T SAE spline
(1.25) H For ISO 80-A2HW pad
Output shaft 26T, 32/64 DP, with a 11T SAE spline
30° press. angle involute spline. J For ISO 100-A2/B4HW pad
H H with a 13T SAE spline
“B” Pad
To mouting 276,0
face (10.87) K (2 places)
86,49 J (2 places)
(3.41) 10,28
(0.40)
J (2 places)
86,0
(3.39)
2 plcs
∅G
107,90 (4.248) K (2 places)
∅ 107,82 (4.244)
86,0 N (2 places)
(3.39)
2 plcs
∅ 35,30
2,00 (0.079) (1.39) M (4 places)
1,90 (0.075) H H
11,75 263,5
(0.46) (10.37)
77,47
(3.05)

Output shaft 26T, 32/64 DP,


30° press. angle involute spline.
53,0 53,0 L Support mounting points
(2.09) (2.09) (4 places)

Model Code Position 25 ∅G H J K L M N


82,625 (3.251) 53,2 .375-16 UNC-2B
A, B – – – –
82,575 (3.249) (2.09) thd. 0.60 deep min.
80,046 (3.15) 54,5 M10 thd x 15,0
G, H – – – –
80,002 (3.149) (2.15) deep min.
.500-13 UNC-2B thd. .500-13 UNC-2B .500-13 UNC-2B
101,65 (4.002) 73,0 44,9 89,8
C, D 1.00" deep min. thd. thru thd. thru
101,60 (4.00) (2.87) (1.77) (3.54) M12 x 24,9 deep min. M10 thd. thru M12 thd. thru
100,0 (3.937) 70,0 44,2 88,38
J, K M12 thd. x 24,9 deep min. M10 thd. thru M12 thd. thru
99,946 (3.935) (2.76) (1.74) (3.48)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 55
Flange
Designations

PVM045/050
Flange Designation ∅A B C D E
101,60/101,55 9,70/9,19 14,55/14,17
SAE J744-101-2 146,0 (5.750) 73,0 (2.875)
(4.000/3.998) (.382/.362) (.572/.557)
100,00/99,95 9,50/9,00 14,27/14,00
ISO 3019/2-100A2HW 140,0 (5.512) 70,0 (2.756)
(3.937/3.935) (.374/.354) (.562/.551)

Pilot Flange Designation ∅A B C D


101,60/101,55 14,55/14,17
SAE 2-bolt mount 73,0 (2.87) 146,0 (5.750)
(4.000/3.998) (.572/.557)
100,00/99,95 14,27/14,00
ISO 100 2-bolt mount 70,0 (2.76) 140,0 (5.512)
(3.937/3.935) (.562/.551)

56 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
End-ported
Models

PVM057/063

Dimensions in millimeters (inches)


See mounting flange options on page 77. 269,7
See shaft options starting on page 78. (10.62)
w/o adj. max. stop

206,2
(8.12)
116,0 82,3
(4.57) (3.24)

82,3
(3.24)

Outlet port “C.” See 32,9 157,0


options on page 82. Inlet port “B.” See (1.30) (6.18)
options on page 82.

Left Hand Rotation, Tube Port 168,2


with Pressure Compensator (6.62)
274,8
SAE .500-13 Inlet port “B.” See (10.82)
UNC-2B thd. 1.06 options on page 82. 292,2 w/adj. max. stop
deep min. (11.50)
254,3
ISO M12 x 1,75 thd. (10,0) Load sense port J".
29.0 deep min. 165.6 See options on page 83.
(6.52)
Outlet port
“C.” See
121,8 38,89 options on
(4.80) (1.53) page 82. 39,0
87,0 (1.54)
199,3 (3.43)
(7.85) 52,38
(2.06)
77,5 Outlet gauge port “K.”
26.19 Inlet gauge port “K” on
(3.05) (1.03)
opposite side. See
options on page 83.
77,78
(3.06) 21,44 13,1 SAE .375-16 UNC-2B thd. 102,8
(.84) (.51) .88 deep min. (4.05)
42,88 26,18 ISO M10 x 1,5 thd. 201,4
(1.69) (1.03) 23,0 deep min. (7.93)
88,7 75,7 245,4
(3.49) (2.98) (9.66)
Drain port “F.” Alternate drain port “F” on
Right Hand Rotation, Flange Port opposite side. See options on page 83.
with Load Sensing Control

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 57
Side-ported
Models

PVM057/063

Dimensions in millimeters (inches)


See mounting flange options on page 77.
See shaft options starting on page 78.

269,7
(10.62)
198,1
(7.80) w/o adj. max. stop
116,0
(4.57) 82,3
(3.24)

Outlet gauge port 82,3


“K.” See options Inlet gauge port “K.” (3.24)
on page 83. See options on 157,0
page 83. (6.18)

32,9
(1.30)
Left Hand Rotation with 168,2
Pressure Compensator (6.62)
274,8
(10.82)

Load sense port “J.” See 292,2


options on page 83. (11.50)
266,5 w/adj. max. stop
247,9 (10.49)
Adjustable maximum (9.76) 241,5
displacement stop Outlet (9.51)
Inlet port “B.” See 165,6 port “C.” 213,4
1 turn = 2.98 l/min See
options on page 82. (6.52) (8.40)
(0.79 USgpm) options
on page
83.
38,89 121,8
(1.53) (4.80) 87,0 39,0
199,3 (3.43) (1.54)
(7.85)
77,78
(3.06)
77,5
(3.05) 26,2
(1.03)
52,37
21,44 SAE .500-13 (2.06) 13,1
(.84) UNC-2B thd. (.51)
42,88 1.06 deep min. 61,5 57,0 SAE .375-16
102,8
(2.42) (2.24) UNC-2B thd. .88 26,19
224,4 (1.69) ISO M12 1,75 (4.05)
(8.83) 75,0 75,0 deep min. (1.03)
thd. 29.0 deep min
To mounting face (2.95) (2.95) ISO M10 x 1,5 thd.
23,0 deep min.
Right Hand Rotation with
Load Sensing Control Drain port “F.” Alternate drain port “F” on
opposite side. See options on page 83.

58 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models

PVM057/063

Dimensions in millimeters (inches.)


See pilot flange options on page 77.
See shaft options starting on page 78. 80,1
(3.15)
44,8
(1.76)
Alternate drain port “F”
205,0
(8.07) S (See table
116,0 next page)
(4.57)
82,3
(3.24)

82,3
(3.24)
T1 (2 plcs.) 157,0
(6.18)
32,9
(1.30)
M12 thd. 21,0 deep
(4 plcs.)
∅R 168,2
(6.62)
Left Hand Rotation with Pressure Compensator
and SAE 2-bolt “A” Flange (no adapter)
Load sense port “J.” See
options on page 83.
SAE .500-13 .
UNC-2B thd. 1.06 254,6 292,2
(10,0) Outlet (11.5)
deep min. port “C.” 284,4
ISO M12 x 1,75 thd. See (11.2)
29.0 deep min. 165,6 options 213,4
Inlet port “B.” See
options on page 82. (6.52) on page (8.40)
82.

121,8 39,0
(4.80) 87,0 (1.54)
199,3 (3.43)
(7.85)
77,78
(3.06)
77,5
(3.05) 52,37
38,89 (2.06)
21,44 (1.53) 26.18 13,1
(.84) (1.03) (.52) 102,8
12,0 14,0
42,88 Inlet gauge (.47) (.55) 26,2 (4.05)
(1.69) Outlet gauge port (1.03)
224,4 port “K.” See “K.” See options
options on 89,0 92,0 Drain port “F.” Alternate
(8.83) (3.50) (3.62) on page 83.
page 83. drain port “F” on opposite
To mounting face side. See options on
page 83.
Right Hand Rotation with Load Sensing Control
and SAE 2-bolt “A” Flange (no adapter) SAE .375-16 UNC-2B thd.
.88 deep min.
ISO M10 x 1,5 thd.
23,0 deep min.

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 59
Thru-drive
Models

PVM057/063
Coupling Length Code
Dimensions in millimeters (inches)
68,7 SAE “A,” 9T 62,5 (2.46) A, G
(2.70) “S” SAE “B,” 13T 93,0 (3.66) C, J
SAE “B-B,” 15T 93,0 (3.66) D, K
SAE “C,” 14T 93,0 (3.66) E, L

Model Code Postion 25


Coupling (see table) Description
A SAE “A,” 9T, 16/32 DP,
30° pressure angle
involute spline
C SAE “B,” 13T, 16/32 DP,
Coupling length 30° pressure angle
(see table) involute spline
D SAE “B-B,” 15T, 16/32 DP,
“B” Adapter Flange 30° pressure angle
To mounting face involute spline
309,9 E SAE “C,” 14T, 12/24 DP,
(12.20) 30° pressure angle
involute spline
G For ISO 80-A2HW pad
“T1” with a 9T SAE spline
H For ISO 80-A2HW pad
with a 11 T SAE spline
J For ISO 100-A2/B4HW pad
with a 13T SAE spline
35,0 K For ISO 100-A2/B4HW pad
(1.38) with a 15T SAE spline
“T2”
(4 plcs) L For ISO 125-A2/B4HW pad
with a 14T SAE spline
M For ISO 125-A2/B4HW pad
with a 17T SAE spline
“V” Support
mounting point
(4 plcs) 92,0
297,4 ∅“R”
(11.70) (3.62)
To mounting face Right hand rotation with Load Sensing Control and
SAE 2-/4-bolt “B” adapter flange

Support
Model Code Position 25 Pilot Dia. Pilot Depth 2-bolt 4-bolt Mounting Point
Flange Bolt “R” “S” “T1” “T2” “V”
A, B SAE “A” 2-bolt SAE ∅82,6 (3.25±.001) 8,6/8,1 (.32/.34) .375-16 UNC-2B thd. N/A N/A
G, H ISO 80 ISO ∅80,05 (3.15) 9,0/8,0 (.35/.31) M10 thd. N/A N/A
C, D SAE “B” 2-/4-bolt SAE ∅101,65 (4.002±.001) 12,5/11,5 (.49/.45) .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B
thd. .98" deep
J, K ISO 100 ISO ∅100,05 (3.94) 12,5/11,5 (.49/.45) M12 thd. M12 thd. M12 thd. x 25,0 deep

60 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models

PVM057/063

Dimensions in millimeters (inches)


“C” Adapter Flange

To mounting face
297,4 92,0
(11.70) ∅ “R” (3.62)

“V” Support 107,0


mounting point (4.21)
(4 plcs)

35,0
(1.38)
(4 plcs)

“T2”

“ T1”
309,9
(12.20)
Left hand rotation with Pressure Compensator and
To mounting face SAE 2-/4-bolt “C” adapter flange

Support
Model Code Position 25 Pilot Dia. Pilot Depth 2-bolt 4-bolt Mounting Point
Flange Bolt “R” “S” “T1” “T2” “V”
E, F SAE “C” 2-/4-bolt SAE ∅127,05 (5.002±.001) 15,5/14,5 (.61/.57) 625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B
thd. .98" deep
L, M ISO 125 ISO ∅125,05 (4.92) 15,5/14,5 (.61/.57) M12 thd. M12 thd. M12 thd. x 25,0 deep

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 61
End-ported
Models

PVM074/081

Dimensions in millimeters (inches)


Lifting point .375-16 UNC thd.
See pilot flange options on page 77. 10,0 (.39) deep with SAE drain
See shaft options starting on page 78. M10 thd. 10,0 (.39) deep with ISO drain
Alt. drain port "F". See
Alt. drain port "F". See options on page 83.
102,0 options on page 83.
(4.02)

87,0 2X
(3.43)
Outlet gauge Inlet gauge
port "K". See port "K".
options on See option
page 83. on page
83.

Outlet port "C". See


options on page 82. Inlet port "B". 33,9
See options on 113,6 (1.33)
page 82. (1.33)
Left hand rotation
with Pressure Compensator w/o max adj stop
319,1
(12.56)
334,8
(13.18)
194,8
(7.67)
151,6 Load sense port "J". 145,2
4,48 (5.97) See options on (5.72)
(0.18) page 83. C/G location

Inlet port "B".


See options 110,0 33,0
on page 82. (4.33) (1.30)
Outlet port "C".
See options
on page 82.

Inlet gauge 16,9


port "K". See (.67)
options on
page 83.
Outlet gauge port "K"

42,5 57,0
(1.67) (2.24)
96,8 84,5 182,6
(3.81) (3.33) Drain port "F". See (7.19)
options on page 83.
261,6
114,0 114,0
(10.30)
(4.49) (4.49)
Right hand rotation 278,6
with Load Sensing Control (10.97)

62 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Side-ported
Models

PVM074/081

Dimensions in millimeters (inches)

See pilot flange options on page 77. Lifting point .375-16 UNC thd.
See shaft options starting on page 78. 10,0 (.39) deep with SAE drain
M10 thd. 10,0 (.39) deep with ISO drain

Alt. drain port "F". See


102,0 options on page 83.
Alt. drain port "F". See
(4.02)
options on page 83.

Inlet port "B". 87,0


Outlet port 2X
See options (3.42)
"C". See
options on page 82.
on page 82.

Outlet gauge port Inlet gauge port


"K". See options "K". See options
on page 83. on page 83. 33,9
Left hand rotation (1.33)
113,6
with Pressure Compensator (4.47)
319,1 w/o max adj stop
(12.56)
334,8
Max. Adj. stop. One rotation will change (13.18)
Inlet port "B". See displacement 6,1-6,8 l/min
options on page 82. (1.6-1.8 USgpm) at 1800 rpm 194,8
( 7.67)
151,6 Load sense port "J". 146,1
TO MOUNTING FACE
(5.97) See options on page 83. ( 5.75)
249,6 Inlet gauge 4,3
(9.83) port "K". (.17) C/G location
See options
on page 83.

110,0
86,0 Outlet (4.33) 33,0
(3.39) gauge (1.30)
port "K".
See options
on page 83. 16,8
86,0 (.66)
(3.39)
Outlet port
"C". See
options on
65,0 65,0 page 82.
Alt. drain port "F". 181,6
(2.56) (2.56)
See options on page 83. (7.15)
Drain port
92,0 91,0 "F". See 246,6
(3.62) (3.58) options on (9.71)
page 83. 279,6
114,0 114,0
(4.49) (4.49) (11.01)
Right hand rotation 288,0
with Load Sensing Control (11.34)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 63
Thru-drive
Models

PVM074/081

Dimensions in millimeters (inches)


Lifting point .375-16 UNC thd.
See pilot flange options on page 77. 10,0 (.39) deep with SAE drain
See shaft options starting on page 78. M10 thd. 10,0 (.39) deep with ISO drain

Alt. drain port "F". See


102,0 Alt. drain port "F". See options on page 83.
(4.02) options on page 83.

Outlet port "C". 87,0 2X


See options on Inlet port "B". (3.42)
page 82. See options
on page 82.

Outlet gauge port Inlet gauge port


"K". See options "K". See options
on page 83. on page 83.
Left hand rotation 33,9
113,6 (1.33)
with Pressure Compensator (4.47)
319,1 w/o max adj stop
(12.56)
334,8
Inlet port "B". See Max. Adj. stop. One rotation will change (13.18)
options on page 82. displacement 6,1-7,4 l/min
(1.7-1.9 USgpm) at 1800 rpm 194,8
Load sense port "J". (7.67)
TO MOUNTING FACE 151,6 See options on page 83. 146,1
249,6 4,08 (5.97) (5.75)
(9.83) (.16) C/G location

110,0
86,0 2X T1 Outlet gauge (4.33) 33,0
(3.39) port "K". (1.30)
See options
on page 83.
14.5
86,0 (0.57)
(3.39)
Outlet port "C".
See options on
"A2" 45,0 page 82.
Alt. drain port 181,6
(1.77)
"F". See options Inlet gauge (7.15)
on page 83. port "K". 92,0 91,0 246,6
See options (3.62) (3.58) Drain port "F". (9.71)
on page 83. See options 277,6
114,0 114,0 on page 83. (10.93)
(4.49) (4.49) 322.6
Right hand rotation (12.70)
with Load Sensing Control
and 2-bolt“A” flange

64 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models

PVM074/081
Coupling Length Code
Dimensions in millimeters (inches)
68,3 SAE “A,” 9T 64,5 (2.54) A, G
(2.69) SAE “A,” 11T 65,3 (2.57) B, H
“S” 43,3 SAE “B,” 13T 95,3 (3.75) C, J
(1.70) “S” SAE “B-B,” 15T 95,3 (3.75) D, K
SAE “C,” 14T 95,3 (3.75) E, L
SAE “C-C,” 17T 91,8 (3.61) F, M
“R3”
“R3”
“R1” “R2" “R1” “R2”

Model Code Position 25


Coupling (see table) Description
Coupling (see table)
Coupling length A SAE “A,” 9T, 16/32 DP,
Coupling length 25,0 (.98) (see table) 30° pressure angle,
(See table) involute spline
With adapter plate Without adapter plate
B SAE “A,” 11T, 16/32 DP,
30° pressure angle,
involute spline
“B” Adapter Flange
C SAE “B,” 13T, 16/32 DP,
30° pressure angle,
To mtg, face 372,6 involute spline
(14.68)
D SAE “B-B,” 15T, 16/32 DP,
30° pressure angle,
involute spline
E SAE “C,” 14T, 12/24 DP,
30° pressure angle,
4X involute spline
35,0 F SAE “C-C,” 17T, 12/24 DP,
(1.38) “A1” 30° pressure angle,
involute spline
G For ISO 80-A2HW pad
with a 9T SAE spline
92,0 “T1” H For ISO 80-A2HW pad
(3.62) with a 11 T SAE spline
I For ISO 100-A2/B4HW pad
with a 13T SAE spline
4X “W” “T2”
K For ISO 100-A2/B4HW pad
335,1 “A1” with a 15T SAE spline
To mtg, face
(13.19) “A2” L For ISO 125-A2/B4HW pad
View rotated 90° with a 14T SAE spline
Right hand rotation with Load Sensing Control
and ISO or SAE 2-/4-bolt “B” adapter flange M For ISO 125-A2/B4HW pad
with a 17T SAE spline

Model Code Position 25 Pilot O-ring O-ring Pilot Support


Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
A, B SAE “A” SAE ∅82,6 89,65 2,00 (.08) 9,0/8,0 .375-16 UNC-2B thd. N/A N/A N/A 53,2
2-bolt ∅(3.25) (3.53) 1,90 (.07) (.25/.31) (2.09)
G, H ISO 80 ISO ∅80,05 ∅89,75 2,70 (.11) 9,0/8,0 54,5
M10 thd. N/A N/A N/A
∅(3.15) ∅(3.53) 2,60 (.10) (.35/.31) (2.15)
C, D SAE “B” SAE ∅101,65 ∅108,05 2,00 (.08) 12,5/11,5 .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 44,9 73,0
2-/4-bolt ∅(4.00) ∅(4.25) 1,90 (0.7) (.49/.45) thd. .98" deep (1.77) (2.87)
J, K ISO 100 ISO ∅100,05 ∅108,75 2,70 (.11) 9,0/8,0 M12 thd. M10 thd. M12 thd. 25,0 deep 44,19 70,0
∅(3.94) ∅(4.28) 2,60 (.10) (.35/.31) (1.74) (2.76)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 65
Thru-drive
Models

PVM074/081

Dimensions in millimeters (inches)


“C” Adapter Flange

To mtg, face 347,6


(13.69)

4X 35,0
(1.38)

“A1”
“T1” 92,0
(3.62)
4X “W”

“T2”
To mtg, face 335,1 “A1”
(13.19)
“A2”
View rotated 90°
Left hand rotation with Pressure Compensator
and ISO or SAE 2-/4-bolt “C” Adapter Flange

Model Code Position 25 Pilot O-ring O-ring Pilot Support


Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
E, F SAE “C” SAE ∅127,05 ∅133,45 2,00 (.08) 15,5/14,5 .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 57,25 90,5
2-/4-bolt ∅(5.00) ∅(5.25) 1,90 (.07) (.61/.57) thd. .98" deep (2.25) (3.56)
L, M ISO 125 ISO ∅125,05 ∅133,75 2,70 (.11) 15,5/14,5 M16 thd. M12 thd. M12 thd. 25,0 deep 56,57 90,0
∅(4.92) ∅(3.26) 2,60 (.10) (.61/.57) (2.23) (3.54)

66 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
End-ported
Models

PVM098/106

Dimensions in millimeters (inches) Alt. drain port “F”. See options on page 83.

See pilot flange options on page 77. Lifting point .375-16 UNC thd. 10,0 (.39) deep with
SAE drain M10 thd. 10,0 (.39) deep with ISO drain
See shaft options starting on page 78.
Alt. drain port “F”. See
options on page 83.
121,0
(4.76)

2X 95,0
(3.74)
Inlet port “B”.
See options
Outlet port on page 82.
“C”. See
options on
page 82. 162,0
Inlet gauge (6.38)
Outlet gauge port “K”. See
port “K”. See 33,9
options on
options on (1.33)
page 83. 115,5
page 83.
(4.55)
Left hand rotation with Pressure Compensator w/o max adj stop
342,4
(13.48)
357,8
(14.09)
214,6
(8.45)
Load sense port 155,7
170,6
16,4 (6.72) Max. Adj. stop. One “J”. See options (6.13)
(.65) rotation will change on page 83. C/G location
displacement
7,9-8,7 l/min
(2.1-2.3 USgpm)
Inlet port “B”. at 1800 rpm
See options on 107,5 37,0
page 82. (4.23) (1.46)
Outlet port
“C”. See
options on
page 82. 35,5
Inlet gauge (1.40)
port “K”. See
options on Outlet gauge port
page 83. “K”. See options
on page 83.
49,7 57,0 2X 194,5
(1.96) (2.24) (7.66)
107,8 87,3 Drain port “F”.
See options 278,9
(4.24) (3.44) (10.98)
119,0 119,0 on page 83.
(4.69) (4.69) 301,9
(11.89)
Right hand rotation with Load Sensing Control

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 67
Side-ported
Models

PVM098/106

Dimensions in millimeters (inches) Alt. drain port “F”. See options on page 83.

See pilot flange options on page 77. Lifting point .375-16 UNC thd.10,0 (.39) deep with
SAE drain M10 thd. 10,0 (.39) deep with ISO drain
See shaft options starting on page 78.
Alt. drain port “F”. See
options on page 83.
121,0
(4.76)

2X 95,0
(3.74)

Inlet port “B”.


Outlet port See options
“C”. See options on page 82.
on page 82.
162,0
(6.38)
Outlet gauge port Inlet gauge
“K”. See options port “K”. See 33,9
on page 83. options on (1.33)
115,5
page 83.
Left hand rotation (4.55)
with Pressure Compensator w/o max adj stop
342,4
(13.48)
357,8
(14.09)

Max. Adj. stop. One rotation will


Inlet port “B”. See
change displacement 7,9-8,7 l/min
options on page 82. 214,6
(2.1-2.3 USgpm) at 1800 rpm Load sense port “J”.
To mounting face (8.45)
170,6 See options on page 83. 155,7
276,9 Inlet gauge
(10.90) 16,4 (6.72) (6.13)
port “K”. (.65) C/G location
See options
on page 83.

37,0
92,5 Outlet gauge 107,5 (1.46)
(3.64) port “K”. See (4.23)
options on
page 83.
35,5
90,0 (1.40)
(3.54) Outlet port “C”. See
options on page 82.

Alt. drain port 70,0 70,0 2X 194,5


“F”. See options (2.76) (2.76) (7.66)
266,9
on page 83. 98,0 91,0 Drain port “F”. See (10.51)
(3.86) (3.58) options on page 83. 305,6
119,0 119,0 (12.03)
(4.69) (4.69) 322,6
(12.70)
Left hand rotation with Load Sensing Control

68 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models

PVM098/106

Dimensions in millimeters (inches) Alt. drain port "F". See options on page 83.
Lifting point .375-16 UNC thd. 10,0 (.39) deep with
See pilot flange options on page 77. SAE drain M10 thd. 10,0 (.39) deep with ISO drain
See shaft options starting on page 78. Alt. drain port "F". See
options on page 83.
347,9
(13.70)
121,0
(4.76)
2X 95,0
(3.74)

Outlet port Inlet port "B".


"C". See See options
options on on page 82. 162,0
page 82.
(6.38)

33,9
(1.33)
Outlet gauge port Inlet gauge port 115,5
"K". See options "K". See options (4.55)
on page 83. on page 83. w/o max adj stop
Left hand rotation 342,4
with Pressure Compensator (13.48)
357,8
(14.09)

Max. Adj. stop. One rotation will change


Inlet port "B". See Outlet gauge port "K".
displacement 7,9-8,7 l/min
options on page 82. See options on page 83. 214,6
(2.1-2.3 USgpm) at 1800 rpm
To mounting face (8.45)
276,9 170,6 Load sense port "J". 164,4
(10.90) 17,3 (6.72) See options on page 83. (6.47)
(0.68) C/G location
36,6
2X T1
(1.44)
2X
150,0
37,0
(5.91) 107,5
92,5 (1.46)
(4.23)
(3.64)

90,0
(3.54) 42,0
(1.65)
Outlet port "C".
Alt. drain port "F". See A2* 45,0 See options 2X 194,5
options on page 83. (1.77) on page 82. (7.66)
266,9
98,0 91,0 Drain port "F". (10.51)
Inlet gauge port "K". See (3.86) (3.58) See options
options on page 83. 119,0 119,0 on page 83.
(4.69) (4.69)
Right hand rotation with 2-bolt “A” flange
and Load Sensing Control
*See table on following page.

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 69
Thru-drive
Models

PVM098/106
Coupling Length Code
Dimensions in millimeters (inches)
68,3 SAE “A,” 9T 64,5 (2.54) A, G
(2.69) SAE “A,” 11T 65,3 (2.57) B, H
“S” SAE “B,” 13T 95,3 (3.75) C, J
43,3
Coupling (1.70) “S” SAE “B-B,” 15T 95,3 (3.75) D, K
(see table) SAE “C,” 14T 95,3 (3.75) E, L
SAE “C-C,” 17T 91,8 (3.61) F, M
“R3” “R3”
“R1” “R2”
“R1” “R2”

Coupling (see table) Model Code Position 25


Coupling length (see table) Description
Coupling length 25,0
(.98) A SAE “A,” 9T, 16/32 DP,
(see table) 30° pressure angle,
With adapter plate Without adapter plate involute spline
B SAE “A,” 11T, 16/32 DP,
30° pressure angle,
“B” Adapter Flange involute spline
C SAE “B,” 13T, 16/32 DP,
30° pressure angle,
To mtg, face 372,6 involute spline
(14.68)
D SAE “B-B,” 15T, 16/32 DP,
30° pressure angle,
involute spline
E SAE “C,” 14T, 12/24 DP,
35,0 30° pressure angle,
(1.38) involute spline
(4 plcs) F SAE “C-C,” 17T, 12/24 DP,
“A1” 30° pressure angle,
involute spline
G For ISO 80-A2HW pad
“T1” with a 9T SAE spline
92,0
(3.62) H For ISO 80-A2HW pad
with a 11 T SAE spline
“T2” J For ISO 100-A2/B4HW pad
360,4 with a 13T SAE spline
To mtg, face (14.19) “W” Support K For ISO 100-A2/B4HW pad
mounting “A1” with a 15T SAE spline
View Rotated 90° points
(4 plcs) “A2” L For ISO 125-A2/B4HW pad
with a 14T SAE spline
Right hand rotation with “CV” compensation and M For ISO 125-A2/B4HW pad
ISO or SAE 2-/4-bolt “B” adapter flange with a 17T SAE spline

Model Code Position 25 Pilot O-ring O-ring Pilot Support


Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points 4-bolt 2-bolt
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
A, B SAE “A” SAE ∅82,6 ∅89,65 2,00 (.08) 9,0/8,0 .375-16 UNC-2B thd. 0.59 deep N/A N/A N/A 53,2
2-bolt ∅⊇(3.25) ∅ (3.53) 1,90 (.07) (.35/.31) (2.09)
G, H ISO 80 ISO ∅80,05 ∅89,75 2,70 (.11) 9,0/8,0 M10 thd. x 18,0 deep N/A N/A N/A 54,5
∅ (3.15) ∅⊇(3.53) 2,60 (.10) (.35/.31) (2.15)
C, D SAE “B” SAE ∅101,65 ∅108,05 2,00 (.08) 12,5/11,5 .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 44,9 73,0
2-/4-bolt ∅(4.00) ∅ (4.25) 1,90 (.07) (.49/.45) thd. .98" deep (1.77) (2.87)
J, K ISO 100 ISO ∅100,05 ∅108,75 2,70 (.11) 12,5/11,5 M12 thd. M12 thd. M12 thd. 25,0 deep 44,19 70,0
∅⊇(3.94) ∅⊇(4.28) 2,60 (.10) (.49/.45) (1.74) (2.76)

70 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models

PVM098/106

Dimensions in millimeters (inches)


“C” Adapter Flange

To mtg, face 372,9


(14.68)

4X 35,0
(1.38)

“T1” “A1”
92,0
(3.62)
4X “W” Support
mounting points “T2”

To mtg, face 360,4 “A1”


(14.19) “A2”
View Rotated 90° Left hand rotation with Pressure Compensator
and ISO or SAE 2-/4-bolt “C” adapter flange

Model Code Position 25 Pilot O-ring O-ring Pilot Support


Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points 4-bolt 2-bolt
“R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”
E, F SAE “C” SAE 127,05 ∅133,45 2,00 (.08) 15,5/14,5 .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 57,25 90,5
2-/4-bolt (5.00) (5.25) 1,90 (.07) (.61/.57) thd. .98'' deep (2.25) (3.56)
L, M ISO 125 ISO ∅125,05 ∅133,75 2,70 (.11) 15,5/14,5 M16 thd. M12 thd. M12 thd. x 25,0 deep 56,57 90,0
(4.92) (5.27) 2,60 (.10) (.61/.57) (2.23) (3.54)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 71
End-ported
Models

PVM131/141

Dimensions in millimeters (inches)


See mounting flange options on page 77.
See shaft options starting on page 78.

369,4 (14.54)
230,4 (9.07)
131,0
34,0 132,7 (5.16)
(1.34) (5.22) “B” inlet port
172,0
(6.77)
“C”
outlet
port
115,0
(4.53) “K”
“K”
Outlet Inlet
gage gage
port port
Optional drain port “F” Adjustable maximum stop option.
Torque locknut to 37-45 Nm (27-33 lb ft.) Left hand rotation
One turn of screw will change pump with Pressure Compensator
displacement 5,7 cm3/rev (0.35 in3/rev.)
Turn CCW to destroke.

65,0 (2.56) 2 plcs. 55,0 (2.17) 2 plcs. “K” Inlet 132,7 (5.22)
gage port
110,5 (4.35) R.H.
143,5 (5.65) 346,1(13.63) max. length 94,5 (3.72) L.H.
w/o max. adj. stop
111,5 “J” Load sense signal port
(4.39) 122,6 (4.83) 2 plcs.
2 plcs. 180,6 (7.11)
“F2”

“B” inlet
port

“B2” 4 plcs.

55,0
(2.17) 106,0 “K” Inlet “K” Outlet
(4.17) gage port gage port
“C” Outlet
25,0 port
“F3” (0.98) 49,7 (1.95)
“F” drain port 192,6 (7.58) “C2” 4 plcs.
Optional drain 2 plcs. 64,0
port “F” 330,6 (13.02) (2.52)
Lifting point 104,2 91,5
.500-13 UNC-2B thd. (4.10) (3.60)
18,0 (.709) dp. 2 plcs.
Right hand rotation with
Load Sensing Control

72 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Side-ported
Models

PVM131/141

Dimensions in millimeters (inches)


See mounting flange options on page 77.
See shaft options starting on page 78.
369,4 (14.54) 131,0
280,4 (11.04) CL outlet (5.16)
172,0 port Inlet gage
(6.77) 230,4 (9.07) port “K”
34,0
(1.34)
132,7
(5.22) Inlet
port “B”
341,1(13.43) gage
port spotface
318,1(12.52) gage
port spotface
280,4 115,0
“C” (4.53)
outlet (11.04)
port ref. Outlet gage port “K”

100,0 (3.94) Outlet port “C”


Optional drain port “F”
“C2” Left hand rotation with
4 plcs. Adjustable maximum stop option. Pressure Compensator
Torque locknut to 37-45 Nm (27-33 lb ft.)
One turn of screw wil change pump
View A - “A” Outlet port displacement 5,7 cm3/rev (0.35 in3/rev) 132,7 (5.22)
55,0 (2.16) 2 plcs. 110,5 (4.35) R.H.
65,0 (2.56) 2 plcs. 94,5 (3.72) L.H.
346,1 (13.63) max. length
w/o max. adj. stop “J”Load sense signal port
111,5
(4.39) 122,6 Inlet gage
2 plcs. (4.82) port “K”
2 plcs. 180,6 (7.11)

143,5
(5.70) “F2”
A

55,0
(2.17) 106,0
(4.17) A
“F” drain port
70,0 Outlet gage
“F3” 192,6 (7.58) (2.76)
Lifting point “B2” port “K”
Optional drain 2 plcs. 4 plcs. 70,0
.500-13 UNC-2B thd. (2.76)
port “F” 298.6 (11.76)
18.0 (.709) dp. 2 plcs.
95.0
Inlet port “B” (3.74)

Right hand rotation with


Load Sensing Control

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 73
Thru-drive
Models

PVM131/141

Dimensions in millimeters (inches)


See mounting flange options on page 77.
See shaft options starting on page 78.
131,0
(5.16)
347,1
(13.67) C
280,4 Loutlet
(11.04) port
230,4
(9.07) 132,7
(5.22)
34,0
(1.33) Outlet port “C.” Inlet port “B.”
172,0 See options on
(6.77) See options
page 82. on page 82.
See coupling “Q2." See
code below table below
See output ∅ “Q1.” See table below
shaft below
8,5 (.33) Left Hand Rotation with Pressure Compensator
and SAE 2-bolt “A” Flange (no adapter)
14,0 (.55) A9
44,7 19,0 (.75) A11
(1.76) 80,0
Drain port “F.” See options (3.15)
on page 83. Inlet port “B.“ See Load sense port “J.” SAE .500-13 UNC-2B
369,4 options on page 82. See options on page 83. thd. 1.00 deep min. or
(14.54) ISO M12 x 27.0 deep
346,1 SAE port 116,1 (4.57) min.
(13.63) w/o max. ISO port 150,0 (5.91) Outlet port “C.”
143,5
(5.65) 122,6 adj. stop See options on
(4.83) 111,5 180,6
(4.39) (7.11) page 82.

65,0 280,4
(2.56) 132,7 (11.04)
(5.22)
15,0
(.59) 55,0
(2.16)

55,0 106,0
(2.17) (4.17) 45,0
54,5 (1.77)
(2.15)
11,5 313,6
173,0 (.45) 40,0 (12.35)
(6.81) Inlet gage (1.57)
port “K.” See Alt. drain port “F.” See
192,6 4,0 options on page 83.
(7.58) options on page 83. 100,0 95,0
(3.94) (3.74) (.16)
298,6 Outlet gage port “K.” See
(11.76) SAE .500-13 UNC-2B options on page 83.
305,6
thd. 1.19 deep min. or
(12.03)
Inlet gage port K" ISO M12 x 31.0 deep min. SAE port 116,1 (4.57)
ISO port 150,0 (5.91)
Right Hand Rotation with Load Sensing Control and
Model Code Position 25 “Q1” Thru-drive Flange “Q2” 2-bolt Thread SAE 2-bolt “A” Flange (no adapter)
A, B SAE J744-82-2 .375-16 UNC-2B
∅82.625/82.575 bore thd. 0.80 deep
G, H ISO 3019/2-80A2 M10 thd. x 18,0 deep
∅80.075/80.25 bore

74 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models

PVM131/141
Model Code Position 25
Dimensions in millimeters (inches) Coupling Code Description
For SAE “A” pad with a 9T, 16/32 DP, 30° pressure angle,
A involute spline
69,7 (2.74)
For SAE “A” pad with a 11T, 16/32 DP, 30° pressure angle,
B
80,0 involute spline
(3.15) Output shaft 14T 12/24 DP external involute spline
C SAE “B,” 13T, 16/32 DP, 30° pressure angle, involute spline
O-ring (furnished) D SAE “B-B,” 15T, 16/32 DP, 30° pressure angle, involute spline
E SAE “C,” 14T, 12/24 DP, 30° pressure angle, involute spline
F SAE “C-C,” 17T, 12/24 DP, 30° pressure angle, involute spline
G For ISO 80-A2HW pad with a 9T SAE spline
H For ISO 80-A2HW pad with a 11T SAE spline
J For ISO 100-A2/B4HW pad with a 13T SAE spline
K For ISO 100-A2/B4HW pad with a 15T SAE spline
L For ISO 125-A2/B4HW pad with a 14T SAE spline
Coupling (See table) M For ISO 125-A2/B4HW pad with a 17T SAE spline

14,0 (.55)

“B” Adapter Flange

372,1 (14.65)

“R2” – 2 places

35,0 (1.38) “R”


4 places 4 places

“R4” Support
mounting points
(4 places)

359,6 (14.16) ∅“R” 92,0 (3.62) 4 places

Right Hand Rotation with SAE 2-/4-Bolt “B”


Flange and ISO 100Adapter Flange

Model Code
Position 25 “R1” Thru-drive Flange “R2” 2-bolt Thread “R3” 4-bolt Thread “R4” Support Mounting Point
SAE J744-101-2 & -4 .500-13 UNC-2B thd. .500-13 UNC-2B thd. .500-13 UNC-2B thd.
C, D ∅101,675/101,625 bore 12,50/11,50 deep 0.98 deep 0.98 deep 0.98 deep
ISO 3019/2-100A2 & B2
J, K M12 thd. x 25,0 deep M12 thd. x 25,0 deep M12 thd. x 25,0 deep
∅100,075/100,025 bore 12,50/11,50 deep

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 75
Thru-drive
Models

PVM131/141

Dimensions in millimeters (inches)

“C” Adapter Flange

359,6 (14.16)
∅ “S1” 92,0 (3.62) 4 places

“S” Support
mounting points
(4 places)

35,0 (1.38)
4 places

“S3”
4 places
“S2”
372,1
372,1(14.65)
(14.65) 2 places

Left Hand Rotation with SAE 2-/4-bolt “C”


and SO 125 Adapter Flange

Model Code
Position 25 “S1” Thru-drive Flange “S2” 2-bolt Thread “S3” 4-bolt Thread “R4” Support Mounting Point
SAE J744-127-2 & -4 .625-11 UNC-2B thd. .500-13 UNC-2B thd. .500-13 UNC-2B thd.
E, F ∅127,075/127,025 bore 15,50/14,50 deep 0.98 deep 0.98 deep 0.98 deep
ISO 3019/2-125A2 & B4
L, M M16 thd. x 25,0 deep M12 thd. x 25,0 deep M12 thd. x 25,0 deep
∅125,075/125,025 bore 15,50/14,50 deep

Port “B”* “B2” “C”* “C2” “F2” “F3”


2.50 inch dia. SAE J518 .500-13 UNC-2B thd. 1.25 inch dia. SAE J518 .500-13 UNC-2B thd. 146,8 114,9
SAE Code 61, low pressure 1.19 deep min. Code 62, high pressure 1.00 deep min. (5.78) (4.52)
64mm diameter. ISO M12 thd. 32mm diameter. ISO M12 thd. 148,5 116,6
ISO
6162 Type II, 315 bar 31,0 deep min. 6162, 400 bar 27,0 deep min. (5.85) (4.59)
*4-bolt flange port. See page 82 for load sensing, drain, and gage port threads.

76 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Mounting Flange
Options

Dimensions in millimeters (inches)


2-bolt “B” Flange
4-bolt “C” or “D” Flange
ISO & SAE
H

2-bolt “C” Flange G


ISO & SAE L

F
L
E K

K
G

A
H

A
45°
∅ J pilot ∅ J pilot

2-bolt or 4-bolt
Series Flange Code Flange Description A E F G H J K L
A SAE J744-16-4 15,88 ∅X XX XX
PVM018 – – – –
(.625)
(XX) (∅X) (Xx) (XX)
PVM020
“B” (special) B SAE J744-25-4 21,81 ∅XX XX XX
PVM045 – – – –
(.859)
XX (∅X) (X) (XX)
PVM050
C SAE J744-101-2 (“B”) 14,3 ∅101,60/101,55 73,0 146,0
PVM057 (.562) – – – – (∅4.000/3.998)
2-bolt (2.874) (5.748)
“B” (special) D ISO 3019/2-100A2HW 14,0 ∅100,00/99,95 70,0 140,0
PVM063 – – – –
(.551) (∅3.937/3.935) (2.756) (5.512)
E SAE J744-127-2 (“C”) 17,4 90,5 181,0 – – ∅127,00/126,95
PVM057 – –
(.685) (3.562) (7.125) (∅5.000/4.998)
PVM063 2-bolt
PVM074 “C” F ISO 3019/2-125A2HW 18,0 90,0 180,0 – – ∅125,00/124,95 – –
PVM081 (.709) (3.543) (7.09) (∅4.921/4.919)
PVM098 G SAE J744-127-4 (“C”) 14,2 57,25 114,50 ∅127,00/126,95
PVM106 4-bolt (.559) – – (2.254) (4.508) (∅5.000/4.998) – –
PVM131 “C”
PVM141 H ISO 3019/2-125B4HW 14,0 ∅125,00/124,95 80,0 160,0
(.551) – – – – (∅4.921/4.919) (3.150) (6.299)
J SAE J744-152-4 (“D”) 20,6 80,82 161,64 ∅152,40/152,35
– – – –
PVM131 4-bolt (.812) (3.182) (6.364) (∅6.000/5.998)
PVM141 “D” K ISO 3019/2-160B4HW 18,0 ∅160,00/159,95 100,0 200,0
– – – –
(.709) (∅6.299/6.297) (3.937) (7.874)
*Flanges for PVM020 and PVM050 are shown on pages 49 and 56, respectively.

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 77
Shaft Options

Dimensions in millimeters (inches)


C
B spline

SAE Splined Shaft

∅A

SAE Spline Shaft Max. Input Torque


Model Series Designation Shaft Code A max. B C D Nm (lb. in.)
SAE J744-16-4 03 15,88 (.625 ) 9T 16/32 DP 37,0 (1.46) 32,0 (1.26) 58 (517)
SAE “A” (9T)
SAE J744-19-4 04 19,05 (.750) 11T 16/32 DP 30,0 (1.18) 38,0 (1.50) 123 (1100)
SAE “A” (11T)
PVM018/020
SAE J744-22-4
SAE “B” (13T) 07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850)
SAE J744-25-4 08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987)
SAE “B-B” (15T)
SAE J744-22-4 07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850)
SAE “B” (13T)
PVM045/050
SAE J744-25-4
SAE “B-B” (15T) 08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987)
SAE J744-22-4 07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850)
SAE “B” (13T)
SAE J744-25-4
PVM057/063 SAE “B-B” (15T) 08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987)
SAE J744-32-4 11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660)
SAE “C” (14T)
SAE J744-32-4
SAE “C” (14T) 11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660)
PVM074/081
PVM098/106 SAE J744-38-4 12 37,57 (1.479) 17T 12/24 DP 54,0 (2.13) 62,0 (2.44) 1215 (10,750)
SAE “C-C” (17T)
SAE J744-32-4 11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660)
SAE “C” (14T)
SAE J744-38-4
PVM131/141 12 37,57 (1.479) 17T 12/24 DP 54,0 (2.13) 62,0 (2.44) 1215 (10,750)
SAE “C-C” (17T)
SAE J744-44-4 14 43,71 (1.721) 13T 8/16 DP 67,0 (2.63) 75,0 (2.95) 1215 (10,750)
SAE “D” (13T)

78 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Shaft Options

Dimensions in millimeters (inches)


C
E key

SAE Keyed Shaft

B ∅A

Max. Input
SAE Keyed Shaft Shaft Torque
Model Series Designation Code A B C D E Nm (lb. in.)
SAE J744-16-1 58
01 15,88 (.625 ) 17,73 (.698) 24,0 (.94) 32,0 (1.26) 4,0 (.157)
SAE “A” (517)
SAE J744-19-1 104
02 19,05 (.750) 21,23 (.836) 24,0 (.94) 32,0 (1.26) 4,81 (.189)
SAE “19-1” (918)
PVM018/020
SAE J744-22-1 135
SAE “B” 05 22,22 (.875) 25,12 (.989) 33,0 (1.31) 41,0 (1.61) 6,35 (.250) (1200)
SAE J744-25-1 215
06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250)
SAE “B-B” (1900)
SAE J744-22-1 135
SAE “B” 05 22,22 (.875) 25,12 (.989) 33,0 (1.31) 41,0 (1.61) 6,35 (.250) (1200)
PVM045/050
SAE J744-25-1 215
06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250)
SAE “B-B” (1900)
SAE J744-25-1 215
SAE “B-B” 06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250) (1900)
PVM057/063
SAE J744-32-1 450
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312)
SAE “C” (3980)
SAE J744-32-1 450
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312)
PVM074/081 SAE “C” (3980)
PVM098/106 SAE J744-38-1 765
SAE “C-C” 10 38,10 (1.50) 42,39 (1.67) 54,0 (2.13) 62,0 (2.44) 9,52 (.375) (6770)
SAE J744-32-1 450
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312)
SAE “C” (3980)
SAE J744-38-1 765
PVM131/141 10 38,10 (1.50) 42,39 (1.67) 54,0 (2.13) 62,0 (2.44) 9,52 (.375)
SAE “C-C” (6770)
SAE J744-44-1 1200
SAE “D” 13 44,45 (1.75) 49,46 (1.95) 67,0 (2.63) 75,0 (2.95) 11,11 (.438) (10,620)

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 79
Shaft Options

Dimensions in millimeters (inches)

D key

ISO Keyed Shaft

E ∅A

Max. Input
ISO Keyed Shaft Shaft Torque
Model Series Designation Code A B C D E Nm (lb. in.)
ISO 3019/2 E20N 15 20 (.787) 8,5 (.335) 36 (1.42) 6 (.236) 22,5 (.886) 113 (1000)
PVM018/020 ISO 3019/2 E25N 16 25 (.984) 8,5 (.335) 42 (1.65) 8 (.315) 28,0 (1.102) 104 (1900)
ISO 3019/2 E25N 17 25 (.984) 10,5 (.413) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
PVM045/050 ISO 3019/2 E25N 17 25 (.984) 10,5 (.413) 42 (1.65) 8 (.315) 28,0 (1.102) 135 (1900)
ISO 3019/2 E25N 17 25 (.984) 10,5 (.413) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
PVM057/063
ISO 3019/2 E32N 18 32 (1.26) 10,5 (.413) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
PVM074/081 ISO 3019/2 E32N 18 32 (1.26) 10,5 (.413) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
PVM098/106 ISO 3019/2 E40N 19 40 (1.57) 10,5 (.413) 82 (3.23) 12 (.472) 43,0 (1.693) 765 (7700)
ISO 3019/2 E32N 18 32 (1.26) 10,5 (.413) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
PVM131/141
ISO 3019/2 E40N 19 40 (1.57) 10,5 (.413) 82 (3.23) 12 (.472) 43,0 (1.693) 765 (7700)
(1) ISO 80mm pilot only – B

(2) ISO 100mm pilot only – D

*Torque of non-thru-drive PVM pump, or combined torque of PVM thru-drive pump and thru-driven pump.
NOTE: In those cases where geometric tolerances of mounting are critical, or where specific tolerance ranges are required and not specified, consult Eaton
Engineering for specific limits.

80 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Input Shaft
Selection Data

SAE SPLINED SHAFTS

Max. Input Torque† Max. Thru-drive Output Torque‡


Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.)
SAE J744-16-4 (SAE “A,” 9T) 03 58 (513) Exceeds maximum input torque
SAE J744-19-4 (SAE “A,” 11T) 04 123 (1100) Exceeds maximum input torque
PVM018/020
SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 123 (1100)
SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 123 (1100)
SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 208 (1850)*
PVM045/050
SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 337 (2987)
SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 208 (1850)*
PVM057/063 SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 337 (2987)
SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 337 (2987)
PVM074/081 SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 515 (4560)
PVM098/106 SAE J744-38-4 (SAE “C-C,” 17T) 12 1215 (10,750) 515 (4560)
SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 640 (5660)
PVM131/141 SAE J744-38-4 (SAE “C-C,” 17T) 12 1215 (10,750) 640 (5660)
SAE J744-44-4 (SAE “D,” 13T) 14 1700 (15,000) 640 (5660)

SAE KEYED SHAFTS

Max. Input Torque† Max. Thru-drive Output Torque‡


Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.)
SAE J744-16-1 (SAE “A”) 01 58 (513) Exceeds maximum input torque
SAE J744-19-1 (SAE “19-1”) 02 104 (920) Exceeds maximum input torque
PVM018/020
SAE J744-22-1 (SAE “B”) 05 135 (1200) 123 (1100)
SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 123 (1100)
SAE J744-22-1 (SAE “B”) 05 135 (1200) 135 (1200)*
PVM045/050
SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 215 (1900)*
SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 215 (1900)*
PVM057/063
SAE J744-32-1 (SAE “C”) 09 450 (3980) 337 (2987)
PVM074/081 SAE J744-32-1 (SAE “C”) 09 450 (3980) 450 (3980)*
PVM098/106 SAE J744-38-1 (SAE “C-C”) 10 765 (6770) 515 (4560)
SAE J744-32-1 (SAE “C”) 09 450 (3980) 450 (3980)*
PVM131/141 SAE J744-38-1 (SAE “C-C”) 10 765 (6770) 640 (5660)
SAE J744-44-1 (SAE “D”) 13 1200 (10,620) 640 (5660)

ISO KEYED SHAFTS

Max. Input Torque† Max. Thru-drive Output Torque‡


Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.)
ISO 3019/2 E20N (B mount only) 15 113 (1000) Exceeds maximum input torque
PVM018/020 ISO 3019/2 E25N (B mount only) 16 215 (1900) Exceeds maximum input torque
ISO 3019/2 E25N (D mount only) 17 215 (1900) 123 (1100)
PVM045/050 ISO 3019/2 E25N 17 215 (1900) 215 (1900)*
ISO 3019/2 E25N 17 215 (1900) 215 (1900)*
PVM057/063
ISO 3019/2 E32N 18 450 (3980) 337 (2987)
PVM074/081 ISO 3019/2 E32N 18 450 (3980) 450 (3980)*
PVM098/106 ISO 3019/2 E40N 19 870 (7700) 515 (4560)
ISO 3019/2 E32N 18 450 (3980) 450 (3980)*
PVM131/141
ISO 3019/2 E40N 19 870 (7700) 640 (5660)
†This is maximum total torque of the thru-drive pump and the thru-driven pump(s).
‡This is maximum torque which can be applied to the thru-driven pump(s).
*This value is limited by the maximum input torque.

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 81
Port Options

INLET AND OUTLET PORTS

Inlet/Outlet Port Option Port


Model Series (per model code, page 5) Code Inlet Port “B” Outlet Port “C”
Sae J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
Inch Flange 02 1.25 inch diameter, .4375-14 x 1.12 bolt holes 0.75 inches diameter, .375-16 x .88 bolt holes
ISO 6162 Type II, 315 bar. ISO 6162 Type II, 315 bar.
Metric Flange 04
PVM018/020 31,75mm diameter, M10 x 28 bolt holes 19,05mm diameter, M10 x 22 bolt holes
Inch Tube 01 SAE J1926 O-ring –20, for 1-1/4 inch O.D. tube SAE J1926 O-ring –12, for 3/4 inch O.D. tube
Metric Tube 03 ISO 6149–1, M42 thread ISO 6149–1, M27 thread
British Parallel Pipe 05 ISO 228–1:1994 (E), G 1-1/4 thread ISO 228–1:1994 (E), G 3/4 thread
SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
Inch Flange 02 2.00 inch diameter, .500–13 x 1.06 bolt holes 1.00 inch diameter, .375–16 x .87 bolt holes
ISO 6162 Type II, 315 bar. ISO 6162 Type II, 315 bar.
Metric Flange 04
PVM045/050 51mm diameter, M12 x 27 bolt holes 25mm diameter, M10 x 22 bolt holes
Inch Tube 01 SAE J1926 O-ring–24, for 1-1/2 inch O.D. tube SAE J1926 O-ring–16, for 1 inch O.D. tube
Metric Tube 03 ISO 6149–1, M48 thread ISO 6149–1, M33 thread
British Parallel Pipe 05 ISO 228–1:1994 (E), G 1-1/2 thread ISO 228–1:1994 (E), G1 thread
SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
Inch Flange 02 2.00 inch diameter, .500–13 x 1.06 bolt holes 1.00 inch diameter, .375–16 x .88 bolt holes
ISO 6162 Type II, 350 bar. ISO 6162 Type, 350 bar.
Metric Flange 04
51mm diameter, M12 x 29 bolt holes 25mm diameter, M10 x 23 bolt holes
PVM057/063
Inch Tube 01 SAE J1926 O-ring–24, SAE J1926 O-ring–16
(End ported models only) for 1-1/2 inch O.D. tube for 1 inch O.D. tube
Metric Tube 03 ISO 6149–1, M48 thread ISO 6149–1, M33 thread
(End ported models only)
SAE J518 Code 61, standard pressure. SAE J518 Code 62, high pressure.
Inch Flange 02
2.00 inch diameter, .500–13 x 1.19 bolt holes 1.00 inch diameter, .375–16 x .88 bolt holes
PVM074/081
ISO 6162 Type II, 315 bar. ISO 6162 Type, 400 bar.
Metric Flange 04 51mm diameter, M12 x 20 bolt holes 25mm diameter, M10 x 17 bolt holes
SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
Inch Flange 02
2.50 inch diameter, .500-13 x 1.19 bolt holes 1.00 inch diameter, .375–16 x .88 bolt holes
PVM098/106
ISO 6162 Type I, 350 bar. ISO 6162 Type I, 350 bar.
Metric Flange 04 64mm diameter, M12 x 31 bolt holes 25mm diameter, M10 x 23 bolt holes
SAE J518 Code 61, standard pressure. SAE J518 Code 62, high pressure.
Inch Flange 02
2.50 inch diameter, .500–13 x 1.19 bolt holes 1.25 inch diameter, .500–13 x 1.00 bolt holes
PVM131/141
ISO 6162 Type II, 315 bar. ISO 6162 Type, 400 bar.
Metric Flange 04 64mm diameter, M12 x 31 bolt holes 32mm diameter, M12 x 27 bolt holes

82 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Port Options

DRAIN, LOAD SENSING, AND GAUGE PORTS

Inlet/Outlet Port Option Port


Model Series (per model code, page 5) Code Drain Port “F” Load Sensing Port “J” Gauge Port “K”
SAE J1926 O-ring, .50'' O.D. SAE J1926 O-ring, .25'' O.D. SAE J1926 O-ring, .25'' tube.
Inch Flange or Tube 01, 03 tube. .750–16 UNF 2B thread. tube. .4375–20 UNF 2B thread. .4375–20 UNF 2B thread.
ISO 6149–1 O-ring ISO 6149–1 O-ring ISO 6149–1 O-ring
PVM018/020 Metric Flange or Tube 03, 04 M18 x 1,5 thread M12 x 1,5 thread M12 x 1,5 thread
ISO 228–1:1994 (E) ISO 228–1:1994 (E) ISO 228–1:1994 (E)
British Parallel Pipe 05 G 1/2 thread G 1/4 thread G 1/4 thread
SAE J1926 O-ring, .625'' O.D. SAE J1926 O-ring, .250'' O.D. SAE J1926 O-ring, .375'' O.D. tube.
Inch Flange or Tube 01, 02 tube. .875–14 UNF 2B thread. tube. .4375–20 UNF 2B thread. .5625–18 UNF 2B thread.
ISO 6149–1 O-ring ISO 6149–1 O-ring ISO 6149–1 O-ring
PVM045/050 Metric Flange or Tube 03, 04 M22 x 1,5 thread M12 x 1,5 thread M14 x 1,5 thread
ISO 228–1:1994 (E) ISO 228–1:1994 (E) ISO 228–1:1994 (E)
British Parallel Pipe 05 G 1/2 thread G 1/4 thread G 1/4 thread
SAE J1926 O-ring, .625'' O.D. SAE J1926 O-ring, .375'' O.D. SAE J1926 O-ring, .375'' O.D. tube.
Inch Flange or Tube 01, 02
tube. .875–14 UNF 2B thread. tube. .5625–18 UNF 2B thread. .5625–18 UNF 2B thread.
PVM057/063
ISO 6149–1 O-ring ISO 6149–1 O-ring ISO 6149–1 O-ring
Metric Flange or Tube 03, 04 M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread
SAE J1926 O-ring, .625'' O.D. SAE J1926 O-ring, .375'' O.D. SAE J1926 O-ring, .375'' O.D. tube.
Inch Flange 02
PVM074/081 tube. .875–14 UNF 2B thread. tube. .562–18 UNF 2B thread. .5625–18 UNF 2B thread.
PVM098/106 ISO 6149–1 O-ring ISO 6149–1 O-ring ISO 6149–1 O-ring
Metric Flange 04 M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread
SAE J1926 O-ring, .625'' O.D. SAE J1926 O-ring, .375'' O.D. SAE J1926 O-ring, .375'' O.D. tube.
Inch Flange 02
tube. .875–14 UNF 2B thread. tube. .562 –18 UNF 2B thread. .5625–18 UNF 2B thread.
PVM131/141
ISO 6149–1 O-ring ISO 6149–1 O-ring ISO 6149–1 O-ring
Metric Flange 04 M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 83
Operating
Requirements

INLET PRESSURE, CASE PRESSURE, AND OPERATING TEMPERATURE REQUIREMENTS

Inlet Pressure Case Pressure Operating Temperature


Rated Minimum Maximum Maximum Maximum Maximum
Absolute bar, absolute Gauge Continuous Intermittent Peak Rated Intermittent
bar (psi) (in. Hg) bar (psi) bar (psi) bar (psi) bar (psi) °C (°F) °C (°F)
1,0 (14.5) 0,85 (5) 3,5 (50) 0,5 (7) 2 (30) 3,5 (50) 82 (180) 104 (220)

HYDRAULIC FLUIDS

Minimum Viscosity @ Max.


Recommended Operating Maximum Viscosity Intermittent Temperature of
Viscosity Range at Startup 104°C (220°F)
Fluid cSt (SUS) cSt (SUS) cSt (SUS)
Use antiwear hydraulic oil, or automotive
type crankcase oil (designations SC, SD, SE, 16 to 40 (83 to 187) 1000 (4550) 10 (90)
or SF) per SAE J183 FEB80
For more information, see Eaton publication 579. For operation on other alternative or environmentally friendly fluids, please contact your Eaton Representative.

Fluid Cleanliness your Eaton Representative for Proper fluid condition is Eaton publication 561 –
The M Series pumps are rated specific duty cycle recom- essential for long and satisfac- “Eaton Guide to Systemic
in anti-wear petroleum fluids mendation. tory life of hydraulic components Contamination Control” –
with a contamination level of Eaton M Series pumps, as and systems. Hydraulic fluid Available from your local Eaton
20/18/13 (Eaton) or ISO 18/13. with any variable displacement must have the correct balance distributor. In this publication,
Operation in fluids with levels piston pumps, will operate with of cleanliness, materials, and filtration and cleanliness levels
more contaminated than this is apparent satisfaction in fluids additives for protection against for extending the life of axial
not recommended. Fluids other up to the rating specified here. wear of components, elevated piston pumps and other system
than petroleum, severe service Experience has shown, however, viscosity and inclusion of air. components are listed. Included
cycles, or temperature extremes that pump and hydraulic system Essential information on the is an excellent discussion of the
are cause for adjustment of life is not optimized with high correct methods for treating selection of products needed to
these codes. Please contact fluid contamination levels (high hydraulic fluid is included in control fluid condition.
ISO cleanliness codes).

84 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Installation and
Start-up

Warning: Care should be taken In those cases where geometric Start-up Procedure Once the pump is started,
that mechanical and hydraulic tolerances of mounting are Make sure the reservoir and it should prime within a few
resonances are avoided in the critical, or where specific toler- circuit are clean and free of seconds. If the pump does not
application of the pump. Such ance ranges are required and dirt/debris prior to filling with prime, check to make sure
resonances can seriously not specified, consult Eaton hydraulic fluid. that there are no restrictions
compromise the life and/or safe Engineering for specific limits. between the reservoir and the
operation of the pump. Fill the reservoir with filtered inlet to the pump, that the pump
Direction of shaft rotation, oil and fill to a level sufficient
viewed from the prime mover is being rotated in the proper
Drive Data enough to prevent vortexing at direction, and that there are no
end, must be as indicated in the suction connection to pump
the model designation on the air leaks in the inlet line and
Mounting attitude can be either inlet. It is good practice to connections. Also check to make
horizontal or vertical, using the pump – either right hand clean the system by flushing
(clockwise) or left hand (counter- sure that trapped air can escape
appropriate case drain ports to and filtering, using an external at the pump outlet.
ensure that the case remains clockwise). slave pump.
full of fluid at all times. Consult Direct coaxial drive through After the pump is primed,
your local Eaton Representative Caution: Before the pump is tighten the loose outlet con-
a flexible coupling is recom- started, fill the case through
if a different arrangement is mended. If drives imposing nections, then operate for five
required. the uppermost drain port with to ten minutes (unloaded) to
radial shaft loads are considered, hydraulic fluid of the type to be
please consult your Eaton remove all trapped air from
used. The case drain line must the circuit.
Representative. be connected directly to the
reservoir and must terminate If the reservoir has a sight gage,
below the oil level. make sure the fluid is clear –
not milky.

EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 85
Eaton Eaton Eaton
14615 Lone Oak Road 20 Rosamond Road 46 New Lane, Havant
Eden Prairie, MN 55344 Footscray Hampshire PO9 2NB
USA Victoria 3011 England
Tel: 952 937-9800 Australia Tel: (44) 23 92 486 451
Fax: 952 974-7722 Tel: (61) 3 9319 8222 Fax: (44) 23 92 487 110
www.hydraulics.eaton.com Fax: (61) 3 9318 5714

© 2002 Eaton Corporation


All Rights Reserved
Printed in USA

Vickers
Document No. V-PP-MC-0003-E
August 2002