Professional Documents
Culture Documents
106,0 “K
(4.17) ga
25,0
Piston Pumps
Technical Focus
M-Series Mobile
Variable Displacement
Introduction
M Series mobile pumps are open circuit, axial piston Mounting flanges are offered in SAE and ISO config-
designs. A variety of controls provides the ability to urations, and ports are offered in SAE, ISO, and BSPP
match the pumps to each application. Efficiency of the in both tube and flange versions. This provides a
pump controls allows down-sizing of system cooling wide variety of installation opportunities for global
needs, allowing a smaller and less expensive design to machine design.
be used. Alternatively, cooling capacity could be kept
Side- or end-ported models are available to facilitate
the same and the flow capability of the system
plumbing and help fit the pump to your machine space
increased, thus improving performance and customer
needs. Multiple drain ports allow many mounting
satisfaction.
orientations, reducing installed costs.
A strong proven rotating group allows the pumps to
M Series pumps are capable of operating with many
handle pressures to 280 bar (4000 psi) continuous and
types of hydraulic fluids used in industrial and mobile
320 bar (4600 psi) intermittent – with less maintenance
systems. High-water-content and phosphate ester
cost. High-load bearings and a stiff drive shaft help
fluids can be accommodated, in addition to the typical
provide a pump life of 5000 hours at rated mobile
petroleum based and synthetic fluids.
conditions, reducing operating costs and extending
operating life.
M Series pumps feature a saddle-type yoke with
steel-backed polymer bearings. The stiff yoke reduces
deflection and allows even loading of bearings, Typical Applications Features and Benefits
improving life. A single control piston reduces loading • Loader backhoes • Long pump life
on the yoke, resulting in reduced pump size which • Vibratory cable plows • Quiet pump operation
allows installation in tighter locations. • Mining machinery • Inlet and outlet gauge ports
• Dump truck lifts
and adjustable maximum
M Series pumps operate at a level of quietness that displacement stops –
exceeds the requirements of today’s demanding work • Agriculture tractors standards
conditions. The pumps feature a unique three-piece • Chemical applicator trucks • Astonishingly low 4%
envelope (flange, housing and valve block) specifically • Railroad equipment pressure ripple
created for low fluid-borne and structure-borne noise • Container handling, all-terrain, • Low installed and
levels. Another pump feature – a bimetal timing plate – and truck cranes operating costs
improves pump filling characteristics which, in turn, • Vibratory cable plows • Reduced maintenance
reduce fluid-borne noise and extend pump life. • Mining machinery and tunnel • Flexibility in machine design
boring equipment • Compact size saves space
Proximity of the pump to the vehicle operator
• Utility boom, off-road dump, • Design promotes leak-free
demands a low noise level in the cab. M Series pumps and refuse trucks system
reduce, or in some cases remove, the need for damp-
• Material handling trucks and
ing barriers between the noise source and the opera- rough terrain fork lifts
tor. This saves money on the installed cost of the
• Concrete and asphalt pavers
system while improving customer comfort.
• Feller/bunchers, forwarders,
An adjustable maximum stop provides a means of and log loaders
tuning flow to your system, while gauge ports allow • Crawler dozers
monitoring of inlet and outlet conditions. These stan- • Articulate haulers
dard features reduce system complexity and cost. • Mini-excavators
2 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Table of Contents
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 3
Model Code
Selection
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
P V M 0 1 8 M R 0 1 A E 0 1 A A A 2 8 0 0 0 0 0 0 A 0 A
28 – Design Code
A – A (Initial Release)
4 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Model Code
Options
Displacement Code 018 020 045 050 057 063 074 081 098 106 131 141
cm3/r 18,0 21,1 45,1 50,0 57,4 63,1 73,7 81,0 98,3 106,5 131,1 141,0
in3/r 1.1 1.29 2.75 3.05 3.50 3.85 4.50 4.94 6.00 6.50 8.00 8.60
Shaft Code
PVM PVM PVM PVM PVM PVM
Description 018/020 045/050 057/063 074/081 098/106 131/141
SAE J744-16-1, SAE A, Straight Keyed 01 – – – – –
SAE J744-19-1, SAE 19-1, Straight Keyed 02 – – – – –
SAE J744-16-4, SAE A, 9T Spline 03 – – – – –
SAE J744-16-4, SAE A, 11T Spline 04 – – – – –
SAE J744-22-1, SAE B, Straight Keyed 05 05 – – – –
SAE J744-25-1, SAE B-B, Straight Keyed 06 06 06 – – –
SAE J744-22-4, SAE B, 13T Spline 07 07 07 – – –
SAE J744-25-4, SAE B-B, 15T Spline 08 08 08 – – –
SAE J744-32-1, SAE C, Straight Keyed – – 09 09 09 09
SAE J744-38-1, SAE C-C, Straight Keyed – – – 10 10 10
SAE J744-32-4, SAE C, 14T Spline – – 11 11 11 11
SAE J744-38-4, SAE C-C, 17T Spline – – – 12 12 12
SAE J744-44-1, SAE D, Straight Keyed – – – – – 13
SAE J744-44-4, SAE D, 13T Spline – – – – – 14
ISO 3019/2 E20N,
Straight Keyed 15 – – – – –
ISO 3019/2 E25N,
Straight Keyed, Short Spigot 16 – – – – –
ISO 3019/2 E25N,
Straight Keyed 17 17 17 – – –
ISO 3019/2 E32N,
Straight Keyed, Short Spigot – – 18 18 18 18
ISO 3019/2 E40N,
Straight Keyed, Short Spigot – – – 19 19 19
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 5
Model Code
Options
Inlet/
Code Description Outlet PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141
–24
Inlet –20 –24 – – –
SAE J514 (End ports only)
01
Tube Ports –16
Outlet –12 –16 (End ports only) – – –
SAE J518 Inlet 1.25 inch 2.0 inch 2.0 inch 2.0 inch 2.5 inch 2.5 inch
02
Flange Ports Outlet 0.75 inch 1.0 inch 1.0 inch 1.0 inch 1.0 inch 1.25 inch*
M48
Inlet M42 M48 (End ports only) – – –
ISO 6149-1
03
Tube Ports M33
Outlet M27 M33 – – –
(End ports only)
ISO 6162 Inlet 32mm 51mm 51mm 51mm 64mm 64mm
04
Flange Ports Outlet 19mm 25mm 25mm 25mm 25mm 32mm*
British Standard
05 Parallel Pipe – Inlet G 1-1/4 G 1-1/2 – – – –
Tube Ports Outlet G 3/4 G1 – – – –
*SAE Code 62, high pressure series, or ISO 400 bar. Other flange ports are SAE Code 61, standard pressure series, or ISO 25-350 bar.
25 THRU-DRIVE OPTIONS
6 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Specifications
and Performance
DISPLACEMENT, PRESSURE AND FLOW RATINGS At 93°C (200°F), SAE 10W oil, 1 bar absolute (0 psig) inlet
Geometric Maximum Pressure bar (psi) Maximum Flow at 280 bar (4000 psi)
Displacement Flange Ports Tube Ports
Model Series cm3/r (in3/r) Continuous Intermittent* Peak** l/min (USgpm) @ 1 bar inlet l/min (USgpm) @ 1 bar inlet
PVM018 18,0 (1.10) 280 (4000) 320 (4600) 350 (5000) 46 (12) @ 2800 r/min 46 (12) @ 2800 r/min
PVM020 20,1 (1.22) 230 (3300) 250 (3600) 280 (4000) 53 (14) @ 2800 r/min 53 (14) @ 2800 r/min
PVM045 45,1 (2.75) 280 (4000) 320 (4600) 350 (5000) 115 (30) @ 2600 r/min 106 (28) @ 2400 r/min
PVM050 50,0 (3.05) 230 (3300) 250 (3600) 280 (4000) 125 (33) @ 2600 r/min 116 (31) @ 2400 r/min
PVM057 57,4 (3.50) 280 (4000) 320 (4600) 350 (5000) 140 (37) @ 2500 r/min 128 (34) @ 2300 r/min
PVM063 63,1 (3.85) 230 (3300) 250 (3600) 280 (4000) 150 (40) @ 2500 r/min 140 (37) @ 2400 r/min
PVM074 73,7 (4.50) 280 (4000) 320 (4600) 350 (5000) 163 (43) @ 2400 r/min –
PVM081 81,0 (4.94) 230 (3300) 250 (3600) 280 (4000) 181 (48) @ 2400 r/min –
PVM098 98,3 (6.00) 280 (4000) 320 (4600) 350 (5000) 200 (53) @ 2200 r/min –
PVM106 106,5 (6.50) 230 (3300) 250 (3600) 280 (4000) 222 (59) @ 2200 r/min –
PVM131 131,1 (8.00) 280 (4000) 320 (4600) 350 (5000) 233 (62) @ 2000 r/min –
PVM141 141,0 (8.60) 230 (3300) 250 (3600) 280 (4000) 258 (68) @ 2000 r/min –
**Less than 10% of duty cycle.
**Less than 0.5 second.
Model Series On Stroke (msec) Off Stroke (msec) Model Series On Stroke (msec) Off Stroke (msec)
PVM018 50 20 PVM074 95 30
PVM020 57 22 PVM081 135 30
PVM045 140 40 PVM098 85 24
PVM050 140 23 PVM106 90 25
PVM057 65 20 PVM131 100 30
PVM063 94 20 PVM141 128 28
*Values with pressure compensator control.
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 7
Specifications
and Performance
SPEED, INPUT POWER AND TORQUE RATINGS At 93°C (200°F), SAE 10W oil, 1 bar absolute (0 psig) inlet
8 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Control Options
Pressure Compensator
Control – Code A See model code on page 5 for
spring (pressure) adjustment ranges.
The pump will provide a con-
tinuously modulated flow to “B” inlet
meet changing load demands
at a pre-adjusted compensator “F” case drain
pressure. At pressures below • •
the compensator setting, the
pump will operate at maximum “K” inlet •
+
displacement. See model code gage port
on page 4 for compensator
pressure ranges.
Warning: The pressure compen-
sator may be adjusted beyond
the rated pressure of the pump.
When adjusting the pressure • •
limiter, install a 0-350 bar
(0-5000 psi) gage in the outlet “K” outlet •
+
Change
Outlet Flow
in Flow B
Outlet Pressure P
PRESSURE CUT-OFF CHARACTERISTICS OF PRESSURE COMPENSATOR CONTROL @ 93°C (200°F), STATIC CONDITIONS
“P” Outlet
Rated Speed “Q” Outlet Flow Pressure A B
Model Series r/min l/min (USgpm) bar (psi) bar (psi) L/min (USgpm)
PVM018 2800 42 (11) 280 (4000) 2,8 (40) 4,5 (1.2)
PVM020 2800 52 (14) 230 (3300) 2,8 (41) 4,5 (1.2)
PVM045 2600 115 (30) 280 (4000) 10 (150) 4,5 (1.2)
PVM050 2600 125 (33) 230 (3300) 10 (150) 4,5 (1.2)
PVM057 2500 140 (37) 280 (4000) 3,5 (50) 14 (3.7)
PVM063 2500 159 (42) 230 (3300) 7,4 (107) 11,4 (3.00)
PVM074 2400 174 (46) 280 (4000) 1,5 (20) 37 (9.8)
PVM081 2400 185 (49) 230 (3300) 1,5 (22) 37 (9.8)
PVM098 2200 217 (57) 280 (4000) 1,5 (20) 32 (8.4)
PVM106 2200 234 (62) 230 (3300) 1,5 (22) 24 (6.33)
PVM131 2000 253 (67) 280 (4000) 1,0 (15) 23 (6.0)
PVM141 2000 258 (68) 230 (3300) 7,0 (100) 14 (3.70)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 9
Control Options
10 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
68
Noise Level – dBA
64
60 2800 r/min
Min. Flow
56
600 r/min
52 Max. Flow
48
44 600 r/min
Min. Flow
40
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
90
100 bar
Efficiency – %
(1500 psi)
85
150 bar
(2200 psi)
200 bar
80 (2900 psi)
250 bar
(3600 psi)
75 280 bar
(4000 psi)
320 bar
(4600 psi)
70
0 500 1000 1500 2000 2500 3000
Speed – r/min
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 11
Performance
40 (10.6)
35 (9.2)
250 bar (3600 psi),
30 (7.9) Delivery
100 (885)
320 bar (4600 psi)
90 (796)
Input Torque – Nm (in.lb.)
20 (177)
25 bar (365 psi)
10 (88)
0
0 500 1000 1500 2000 2500 3000
Speed – r/min
12 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
Input Torque and Case Flow Versus Speed Input Torque and Case Flow Versus Speed
@ 93°C (200°F), load sense standby @ 93°C (200°F), cut-off and 1.0 bar absolute
and 1.0 bar absolute (0 psi gauge) inlet (0 psi gauge) inlet
3 (27) 50 (442)
280 bar (4000 psi)
Input Torque - Nm (in.lb.)
45 (398)
Case Flow (l/min (USgpm)
Input Torque
40 (354)
2 (18) 35 (310)
20 bar (300 psi) 30 (265)
differential, 25 (221)
Input Torque 20 bar (300 psi)
differential, 150 bar (2200 psi)
1 (9) Case Flow 5 (1.32) 20 (177) Input Torque
11 bar (160 psi) 4 (1.06) 15 (135) 9 (2.4)
differential, 3 (0.79) 280 bar (4000 psi), Case Flow
Input Torque 11 bar (160 psi) 2 (0.53) 10 (88) 6 (1.6)
differential, 1 (0.26)
0 Case Flow 5 (45) 150 bar (2200 psi) 3 (0.8)
0
0 500 1000 1500 2000 2500 3000 0 Case Flow 0
Speed – r/min 0 500 1000 1500 2000 2500
Speed – r/min
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 13
Performance
PVM020 Typical Noise Levels at 2800 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
77
2800 r/min
74 max. flow
71
68
2800 r/min
min. flow
Noise Level – dBA
65
62
59
56
53
50 600 r/min
47 max. flow
600 r/min
min. flow
44
41
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)
Overall Efficiency versus Speed Delivery and Case Flow versus Speed at 93°C (200°F),
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet Full Flow 1.0 bar absolute (0 psi gauge) inlet
100 60 (15.9)
14 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
PVM020
Input Torque versus Speed at 93°C (200°F), Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
Input Torque and Case Flow versus Speed at Input Torque and Case Flow versus Speed
93°C (200°F), Load Sense Standby and 1.0 bar at 93°C (200°F), Pressure Limit Cut-off and
absolute (0 psi gauge) Inlet 1.0 bar absolute (0 psi gauge) Inlet
3.2 (28) 30 (265)
3.0 (27)
2.8 (25) 27 (239) 210 bar (3000 psi)
Input Torque – Nm (lb.in.)
Input Torque – Nm (lb.in.)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 15
Performance
74
70
600 r/min
2600 r/min Min. Flow
66 Min. Flow
62
58
600 r/min
Max. Flow
54
50
0 50 100 150 200 250 300
(700) (1500) (2200) (2900) (3600) (4400)
Outlet Pressure – bar (psi)
100 bar
(1500 psi)
90
150 bar
(2200 psi)
Efficiency – %
85 50 bar
200 bar (700 psi)
(2900 psi)
80
250 bar
(3600 psi)
75 17 bar
(250 psi)
280 bar
(4000 psi)
70
0 500 1000 1500 2000 2500 3000
Speed – r/min
16 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
100 (26)
90 (24)
280 bar (4000 psi),
80 (21) Delivery
70 (18)
165 (1460)
200 bar (2900 psi)
150 (1327)
135 (1195) 150 bar (2200 psi)
120 (1062)
105 (929) 100 bar (1500 psi)
90 (796)
75 (664)
60 (531) 50 bar (700 psi)
45 (398) 25 bar (365 psi)
30 (265)
17 bar (250 psi)
0
0 500 1000 1500 2000 2500 3000
Speed – r/min
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 17
Performance
44 (59)
40 (54) 200 (2900)
18 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
PVM050 Typical Noise Levels at 2600 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
88
86
84
82
Noise Level – dBA
2600 r/min
max. flow
80
78 2600 r/min
min. flow
76
74
72 600 r/min
max. flow
70
68
66 600 r/min
min. flow
64
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)
Overall Efficiency versus Speed Delivery and Case Flow versus Speed at 93°C (200°F),
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet Full Flow and 1.0 bar absolute (0 psi gauge) inlet
100
psi) Delivery
Delivery – l/min (USgpm)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 19
Performance
PVM050
Input Torque versus Speed at 93°C (200°F), Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
(3300 psi)
0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)
Input Torque and Case Flow versus Speed at Input Torque and Case Flow versus Speed
93°C (200°F), Load Sense Standby and 1.0 bar at 93°C (200°F), Pressure Limit Cut-off and
absolute (0 psi gauge) Inlet 1.0 bar absolute (0 psi gauge) Inlet
8 (71)
55 (487)
7 (62) 50 (442)
20 bar (300 psi) diff. Case Flow 210 bar (3000 psi) Input Torque
Input Torque 45 (398)
l/min
Input Torque – Nm (in.lb.)
6 (53)
Input Torque – Nm (in.lb.)
(USgpm 40 (354)
210 bar
5 (44) 5.0 (1.32) 35 (310) (3000 psi)
11 bar (160 psi) diff.
Input Torque 30 (265) Case Flow Case
4 (35) 4.0 (1.06) Flow l/min
25 (221) (USgpm)
3 (27) 3.0 (.79) 20 (177) 12 (3.2)
20 bar (300 psi)
diff. Case Flow 15 (133) 150 bar (2200 psi) 9 (2.4)
2 (18) 2.0 (.53) Input Torque
11 bar (160 psi)
diff.Case Flow 10 (88) 6 (1.6)
1 (9) 1.0 (.26) 150 bar (2200 psi) Case Flow
5 (44) 3 (0.8)
0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed (r/min) Speed (r/min)
20 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
78 2500 r/min
Max. Flow 2500 r/min
74 Min. Flow
Noise Level – dBA
70
66
62
600 r/min
Max. Flow
58
600 r/min
Min. Flow
54
50
0 50 100 150 200 250 300
(Sound pressure (700) (1500) (2200) (2900) (3600) (4400)
data equivalent to NFPA) Outlet Pressure – bar (psi)
85
(2200 psi)
200 bar
80 (2900psi)
75
250 bar
(3600 psi)
70
280 bar
(4000 psi)
65
0 500 1000 1500 2000 2500
Speed – r/min
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 21
Performance
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 23
Performance
PVM063 Typical Noise Levels at 2500 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
85
2500 r/min
min. flow
80
2500 r/min
max. flow
Noise Level – dBA
75
70
65
600 r/min
max. flow
60
600 r/min
55 min. flow
50
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)
Overall Efficiency versus Speed Delivery and Case Flow versus Speed at 93°C (200°F),
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet Full Flow 1.0 bar absolute (0 psi gauge) Inlet
160 (42)
100
95 140 (37)
50 bar (725 psi)
50 bar (725 psi)
90 120 (32) Delivery
Delivery – l/min (USgpm)
100 bar
85 (1450 psi) 100 (26)
Overall Efficiency (%)
24 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
PVM063
Input Torque versus Speed at 93°C (200°F), Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
90 (121)
250 (2212) 80 (107)
230 bar (3300 psi)
Input Torque – Nm (in.lb.)
Input Torque and Case Flow versus Speed Input Torque and Case Flow versus Speed
at 93°C (200°F), Load Sense Standby and at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar
1.0 bar absolute (0 psi gauge) Inlet absolute (0 psi gauge) Inlet
8 (71) 20.0 (5.28) 80 (708) 20.0 (5.28)
18.0 (4.76) 210 bar (3000 psi) Input Torque 18.0 (4.76)
7 (62) 70 (619)
16.0 (4.23) 16.0 (4.23)
Case Flow – l/min (USgpm)
20 bar (300 psi) 210 bar (3000 psi) Case Flow Case Flow – l/min (USgpm)
Input Torque – Nm (in.lb.)
6 (53) 60 (531)
diff. Input Torque
Input Torque – Nm (in.lb.)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 25
Performance
80
2400 r/min
Min. Flow
76
2400 r/min
72 Max. Flow
Noise Level – dBA
68
600 r/min
64
Min. Flow
60 600 r/min
Max. Flow
56
52
0 50 100 150 200 250 300
(700) (1500) (2200) (2900) (3600) (4400)
Outlet Pressure – bar (psi)
90
50 bar
(700 psi)
85 100 bar
Efficiency – %
(1500 psi)
80 150 bar
(2200 psi)
200 bar
75 (2900psi)
250 bar
70 (3600 psi)
280 bar
(4000 psi)
65
320 bar
(4600 psi)
60
0 500 1000 1500 2000 2500
Speed – r/min
26 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 27
Performance
5 (44)
120 (1062)
Input Torque – Nm (in.lb.)
100 (885)
Case Flow – l/min (USgpm)
80 (708)
150 bar (2200 psi),
Input Torque
60 (531) 30 (7.9)
280 bar (4000 psi), Case Flow
40 (354) 20 (5.3)
20 (177) 10 (2.6)
150 bar (2200 psi), Case Flow
0 0
0 500 1000 1500 2000 2500
Speed – r/min
28 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
PVM081 Typical Noise Levels at 2400 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
82
2400 r/min
max. flow
78
2400 r/min
min. flow
Noise Level – dBA
74
70
66
600 r/min
max. flow
62 600 r/min
min. flow
58
54
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)
Overall Efficiency versus Speed Delivery and Case Flow versus Speed
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet at 93°C (200°F), Full Flow 1.0 bar absolute (0 psi gauge) Inlet
85
Overall Efficiency (%)
psi) Delivery
80 120 (32) 210 bar (3000 Case Flow
230 bar (3300 psi) psi) Delivery l/min
75 100 (26) (USgpm)
70 200 bar 80 (21) 210 bar (3000 psi) Case Flow 8 (2.11)
(2900 psi)
65 60 (16) 6 (1.59)
60 4 (1.06)
40 (11)
55 50 bar (725 psi) Case Flow 2 (0.53)
20 (5)
50 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
Speed – r/min Speed (r/min)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 29
Performance
PVM081
Input Torque versus Speed at 93°C (200°F), Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
250 (2212) 210 bar (3000 psi) 230 bar (3300 psi)
Input Torque and Case Flow versus Speed at 93°C Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet (0 psi gauge) Inlet
9 (80)
80 (708) Case Flow – l/min (USgpm)
20 bar (300 psi) 70 (619)
8 (71) diff. Input Torque 210 bar (3000 psi) Input Torque
Input Torque – Nm (in.lb.)
150 bar
Input Torque – Nm (in.lb.)
30 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
78
76
74
600 r/min
72 Max. flow
70 600 r/min
Min. flow
68
66
64
0 50 100 150 200 250 300
Sound pressure (700) (1500) (2200) (2900) (3600) (4400)
data equivalent to NFP Outlet Pressure – bar (psi)
90
Overall Efficiency (%)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 31
Performance
160 (42)
540 (4779)
320 bar (4600 psi)
480 (4248)
Input Torque – Nm (in.lb.)
120 (1062)
50 bar (700 psi)
60 (531)
17 bar (250 psi)
0
500 1000 1500 2000 2500 3000
Speed – r/min
32 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 33
Performance
200 (1770)
180 (1593)
16 (4.2)
14 (3.7)
12 (3.2)
10 (2.6)
8 (2.1)
6 (1.6)
4 (1.0)
2 (0.5)
0
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Case Flow – l/min (USgpm)
34 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
PVM106 Typical Noise Levels at 2200 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
86
82
2200 r/min
max. flow 2200 r/min
78 min. flow
Noise Level – dBA
74
70
600 r/min
min. flow
66
600 r/min
62 max. flow
58
54
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)
Overall Efficiency versus Speed at Delivery and Case Flow versus Speed at 93°C (200°F),
93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet Full Flow 1.0 bar absolute (0 psi gauge) Inlet
240 (63)
100 220 (58)
100 bar 50 bar (725
95 150 bar (1450 psi) 200 (53) psi) Delivery
(2200 psi) 180 (48)
90
Delivery – l/min (USgpm)
160 (42)
Overall Efficiency (%)
55 40 (11) 4 (1.06)
50 bar (725 psi) Case Flow 2 (0.53)
20 (5)
50
0 500 1000 1500 2000 2500 3000 0
0 500 1000 1500 2000 2500
Speed – r/min Speed (r/min)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 35
Performance
PVM106
Input Torque versus Speed at 93°C (200°F), Input Power versus Speed at 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
450 (3982) 100 (134)
230 bar (3300 psi) 230 bar (3300 psi)
400 (3540)
90 (121) 210 bar (3000 psi)
210 bar (3000 psi)
150 bar (2200 psi)
Input Torque – Nm (in.lb.)
Input Torque and Case Flow versus Speed at 93°C Input Torque and Case Flow versus Speed at 93°C
(200°F), Load Sense Standby and 1.0 bar absolute (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet (0 psi gauge) Inlet
9 (80)
100 (885)
8 (71) Case Case
Flow l/min 90 (796)
11 bar (160 psi) diff. Flow l/min
7 (62) (USgpm) 80 (708) 150 bar (2200 psi)
Input Torque (USgpm)
Input Torque
6 (53) 9.0 (2.38) 70 (619)
5 (44) 60 (531) 30 (7.9)
8.5 (2.25)
4 (35) 50 (442) 25 (6.6)
8.0 (2.11) 210 bar (3000 psi) Case Flow
3 (27) 20 bar (300 psi) 40 (354) 20 (5.3)
7.5 (1.98)
diff. Case Flow 11 bar (160 psi) diff. 30 (265) 15 (4.0)
2 (18) Case Flow 7.0 (1.85) 150 bar (2200 psi)
20 (177) Case Flow 10 (2.6)
1 (9) 6.5 (1.72)
10 (88) 5 (1.3)
6.0 (1.59)
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
Speed (r/min) Speed (r/min)
36 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
600 r/min
74 Min. flow Min. flow
72
70
68
66
600 r/min
64 Max. flow
62
60
58
0 50 100 150 200 250 300
(700) (1500) (2200) (2900) (3600) (4400)
Sound pressure data Outlet Pressure – bar (psi)
equivalent to NFPA
90
80
200 bar (2900 psi)
75
250 bar (3600 psi)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 37
Performance
200 (53)
180 (48) 280 bar (4000 psi),
Delivery
160 (42)
700 (6195)
320 bar (4600 psi)
600 (5310)
Input Torque – Nm (in.lb.)
38 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
110 (148)
100 (134)
90 (121) 200 bar (2900 psi)
80 (107)
70 (94) 150 bar (2200 psi)
60 (80)
50 (67)
100 bar (1500 psi)
40 (54)
30 (40)
50 bar (700 psi)
20 (27)
10 (13) 17 bar (250 psi)
0
0 500 1000 1500 2000 2500
Speed – r/min
12 (106)
11 bar (160 psi)
differential,
10 (88) Input Torque
Case Flow (l/min (USgpm)
8 (71) 7 (1.85)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 39
Performance
220 (1947)
200 (1770)
180 (1593)
18 (4.7)
16 (4.2)
14 (3.7)
12 (3.2)
10 (2.6)
8 (2.1)
6 (1.6)
4 (1.0)
2 (0.5)
0 50 100 150 200 250 300 350
(700) (1500) (2200) (2900) (3600) (4400) (5000)
Outlet Pressure – bar (psi)
Case Flow – l/min (USgpm)
40 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Performance
PVM141 Typical Noise Levels at 2000 and 1000 r/min with Petroleum Oil
(10W) at 93°C (200°F), and 1.0 bar absolute (0 psi gauge) Inlet
88
86
84 2000 r/min
min. flow
82
Noise Level – dBA
80
2000 r/min
78 max. flow
76
74 1000 r/min
min. flow
72
70
1000 r/min
68 max. flow
66
64
0 50 100 150 200 250
Sound pressure data (700) (1500) (2200) (2900) (3600)
equivalent to NFPA. Outlet Pressure – bar (psi)
Overall Efficiency versus Speed at 93°C (200°F), Delivery and Case Flow versus Speed at
and 1.0 bar absolute (0 psi gauge) Inlet 93°C (200°F), Full Flow and 1.0 bar absolute
(0 psi gauge) Inlet
100 280 (74)
95 260 (69)
240 (63) 100 bar
90 100 bar (1500 psi)
Delivery – l/min (USgpm)
85 200 (53)
50 bar 210 bar (3000
80 210 bar (3000 psi) (700 psi) 180 (48) psi) Delivery
230 bar (3300 psi) 160 (42)
75 Case
140 (37) Flow
70 l/min
120 (32) (USgpm)
65 210 bar (3000 10 (2.6)
100 (26)
psi) Case Flow
60 80 (21) 8 (2.1)
60 (16) 6 (1.6)
55
40 (11) 4 (1.1)
50 20 (5) 2 (0.5)
100 bar (1500 psi) Case Flow
0
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
Speed (r/min) Speed (r/min)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 41
Performance
PVM141
Input Torque versus Speed at 93°C (200°F), Input Power versus Speed, 93°C (200°F),
Full Flow and 1.0 bar absolute (0 psi gauge) Inlet and 1.0 bar absolute (0 psi gauge) Inlet
600 (5310) 120 (161)
230 bar
550 (4867) 110 (148) (3300 psi)
230 bar (3300 psi)
500 (4425) 210 bar
210 bar (3000 psi) 100 (134) (3000 psi)
Input Torque – Nm (in.lb.)
Input Torque and Case Flow versus Speed at 93°C Input Torque and Case Flow versus Speed
(200°F), Load Sense Standby and 1.0 bar absolute at 93°C (200°F), Pressure Limit Cut-Off and
(0 psi gauge) Inlet 1.0 bar absolute (0 psi gauge) Inlet
42 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
End-ported
Models
PVM018/020
72,0 58,0
(2.83) (2.28)
72,0 58,0
(2.28) 73,0 76,0
(2.83) (2.87) (2.99)
165,7
(6.52)
85,1
(3.35)
E Inlet gauge
port “K.”
See options
55,2 on page 83.
(2.17)
23,0 Inlet port “B.”
(.91) See options
on page 82.
D ∅A 106,5 34,5 34,0
C (4.19) (1.36) (1.34)
Drain port
166,7 “F.” See
65,2 65,2 (6.56)
(2.57) (2.57) options on Outlet port “C.”
200,7 page 83. See options on page 82.
(7.90)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 43
End-ported
Models
PVM018/020
37,4
(1.47)
34,5 34,0
(1.36) (1.34)
Inlet/Outlet Ports and Control Positioned
for Right Hand Rotation
140,5
(5.53)
126,3
(4.97)
44 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Side-ported
Models
PVM018/020
72,0 171,7
(2.83) (6.76)
to pilot
mtg. flg. 194,1
(7.64)
72,0 58,0
(2.83) (2.28)
108,8
(4.28)
85,1
(3.35)
E
Outlet
gauge
port “K.”
55,2 See options
(2.17)
∅A 23,0 Inlet gauge on page 83.
(.91) port “K.”
106,5 See options
D (4.19)
on page 83. 21,9 21,6
C Alt. drain port “F.” 175,2 (.86) (.85)
See options on (6.90)
65,2 65,2 page 83. 62,9 62,9
205,6 (2.48) (2.48)
(2.57) (2.57) (8.09)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 45
Side-ported
Models
PVM018/020
Outlet
86,5
(3.41)
72,3
(2.85)
Control position for left hand rotation
(Pressure compensated control shown)
46 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models
PVM018/020
72,0
(2.83)
to pilot 164,2
mtg. flg. (6.46)
58,0
72,0 (2.28)
(2.83)
Adjustable maximum displacement
stop (1 turn = 1,1 cm3/rev) Turn
26,1 CCW to reduce displacement.
(1.03)
Control postiion for right hand Inlet port “B.”
(clockwise) shaft rotation, as viewed 221,4 (8.72) with See options on page 82.
from shaft end. Position for left hand adj. max. stop
rotation is shown on following page. 212,3 (8.36) without 114,7
adj. max. stop (4.52)
108,1
(4.14)
∅A 85,1
B (3.35) 23,0
(.91)
60,0
(2.36)
99,0
D (3.90)
C 167,7 62,9 64,2
(6.60) (2.48) (2.53)
87,0 87,0
(3.43) (3.43) 223,2 Alt. drain port “F.”
(8.79) See options on page 83.
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 47
Thru-drive
Models
PVM018/020
Model Code Position 25
Dimensions in millimeters (inches) Description
114,7
Adjustable maximum displacement (4.52) A For SAE “A” pad with a 9T,
stop (1 turn = 1.1 cm3/rev). 16/32 DP, 30° pressure
angle, involute spline
Turn CCW to reduce displacement.
Control position for B For SAE “A” pad with a 11T,
right hand rotation 16/32 DP, 30° pressure
angle, involute spline
(Load sensing G For ISO 80 A2HW pad
Inlet position for right hand control shown) with a 9T, 16/32 DP,
30° pressure angle,
rotation (Position for left hand involute spline
rotation shown below) Outlet H For ISO 80 A2HW pad
with a 11T, 16/32 DP,
30° pressure angle,
involute spline
62,9 64,2
(2.48) (2.53)
Inlet/Outlet Ports and Control Positioned
for Right Hand Rotation
Control position for left hand rotation
(Pressure compensator control shown)
86,5
Output shaft 21T, 32/64 DP, (3.41)
30° press. angle involute spline. 72,3
57,49 (2.85)
(2.26)
40,46 12,25
(1.59) (0.48)
∅27,00
(1.06)
79,4
(3.13) K (2 places)
20,0 20,0
(0.79) (0.79)
48 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Flange
Designations
PVM018/020
“A” Pilot Flange Designation ∅A B C D E
SAE J744-82-2 Model Code A 82,55 (3.25) 8,00 (.315) 106,4 (4.19) 53,2 (2.09) 11,35/10,97 (.447/.432)
ISO 3019/2-80A2HW Model Code B 80,00 (3.15) 8,00 (.315) 109,0 (4.29) 54,5 (2.15) 11,27/11,00 (.444/.433)
“B” Pilot Flange Designation
SAE J744-101-2 Model Code C 101,60 (4.00) 8,00 (.315) 146,0 (5.750) 73,0 (2.875) 14,55/14,17 (.572/.557)
ISO 3019/2-100A2HW Model Code D 100,00 (3.937) 8,00 (.315) 140,0 (5.512) 70,0 (2.756) 14,27/14,00 (.562/.551)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 49
End-ported
Models
PVM045/050
E
130,6
(5.14)
42,0
(1.65)
∅A
D 135,4 (5.33) 53,0
47,8 (1.88) (2.09)
C 175,0 (6.89) 75,1 87,1
87,0 Alternate (2.96) (3.43)
(3.425) 212,0 (8.35) drain port “F”
174,0 Outlet gauge port “K.” Outlet port “C.” See
(6.85) See options on page 83. options on page 82.
50 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
End-ported
Models
PVM045/050
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 51
Side-ported
Models
PVM045/050
42.0
(1.65) ∅A Z
183,0 78,0 D 135,4
(7.20) (3.07) C (5.33) 42.0
208,0 87,0 (1.65)
(8.19) 191,6
230,0 (3.425) (7.54)
(9.06) 174,0
Outlet port “C.” See (6.850) Alternate drain port “F”
options on page 82. Alternate drain port “F” Inlet port “B.” See
options on page 82.
52 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Side-ported
Models
PVM045/050
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 53
Thru-drive
Models
PVM045/050
54 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models
PVM045/050
Model Code Position 25
Dimensions in millimeters (inches) Description
“A” Pad 61,74
(2.43) A For SAE “A” pad with a 9T,
16/32 DP, 30° pressure
42,44 angle, involute spline
(1.59) B For SAE “A” pad with a 11T,
10,03
(0.482) 16/32 DP, 30° pressure
angle, involute spline
C For SAE “B” pad with a 13T,
16/32 DP, 30° pressure
89,70 (3.531) angle, involute spline
∅G ∅ 89,60 (3.527)
D For SAE “B” pad with a 15T,
16/32 DP, 30° pressure
angle, involute spline
G For ISO 80-A2HW pad
∅ 31,75 N (2 places) with a 9T SAE spline
(1.25) H For ISO 80-A2HW pad
Output shaft 26T, 32/64 DP, with a 11T SAE spline
30° press. angle involute spline. J For ISO 100-A2/B4HW pad
H H with a 13T SAE spline
“B” Pad
To mouting 276,0
face (10.87) K (2 places)
86,49 J (2 places)
(3.41) 10,28
(0.40)
J (2 places)
86,0
(3.39)
2 plcs
∅G
107,90 (4.248) K (2 places)
∅ 107,82 (4.244)
86,0 N (2 places)
(3.39)
2 plcs
∅ 35,30
2,00 (0.079) (1.39) M (4 places)
1,90 (0.075) H H
11,75 263,5
(0.46) (10.37)
77,47
(3.05)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 55
Flange
Designations
PVM045/050
Flange Designation ∅A B C D E
101,60/101,55 9,70/9,19 14,55/14,17
SAE J744-101-2 146,0 (5.750) 73,0 (2.875)
(4.000/3.998) (.382/.362) (.572/.557)
100,00/99,95 9,50/9,00 14,27/14,00
ISO 3019/2-100A2HW 140,0 (5.512) 70,0 (2.756)
(3.937/3.935) (.374/.354) (.562/.551)
56 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
End-ported
Models
PVM057/063
206,2
(8.12)
116,0 82,3
(4.57) (3.24)
82,3
(3.24)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 57
Side-ported
Models
PVM057/063
269,7
(10.62)
198,1
(7.80) w/o adj. max. stop
116,0
(4.57) 82,3
(3.24)
32,9
(1.30)
Left Hand Rotation with 168,2
Pressure Compensator (6.62)
274,8
(10.82)
58 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models
PVM057/063
82,3
(3.24)
T1 (2 plcs.) 157,0
(6.18)
32,9
(1.30)
M12 thd. 21,0 deep
(4 plcs.)
∅R 168,2
(6.62)
Left Hand Rotation with Pressure Compensator
and SAE 2-bolt “A” Flange (no adapter)
Load sense port “J.” See
options on page 83.
SAE .500-13 .
UNC-2B thd. 1.06 254,6 292,2
(10,0) Outlet (11.5)
deep min. port “C.” 284,4
ISO M12 x 1,75 thd. See (11.2)
29.0 deep min. 165,6 options 213,4
Inlet port “B.” See
options on page 82. (6.52) on page (8.40)
82.
121,8 39,0
(4.80) 87,0 (1.54)
199,3 (3.43)
(7.85)
77,78
(3.06)
77,5
(3.05) 52,37
38,89 (2.06)
21,44 (1.53) 26.18 13,1
(.84) (1.03) (.52) 102,8
12,0 14,0
42,88 Inlet gauge (.47) (.55) 26,2 (4.05)
(1.69) Outlet gauge port (1.03)
224,4 port “K.” See “K.” See options
options on 89,0 92,0 Drain port “F.” Alternate
(8.83) (3.50) (3.62) on page 83.
page 83. drain port “F” on opposite
To mounting face side. See options on
page 83.
Right Hand Rotation with Load Sensing Control
and SAE 2-bolt “A” Flange (no adapter) SAE .375-16 UNC-2B thd.
.88 deep min.
ISO M10 x 1,5 thd.
23,0 deep min.
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 59
Thru-drive
Models
PVM057/063
Coupling Length Code
Dimensions in millimeters (inches)
68,7 SAE “A,” 9T 62,5 (2.46) A, G
(2.70) “S” SAE “B,” 13T 93,0 (3.66) C, J
SAE “B-B,” 15T 93,0 (3.66) D, K
SAE “C,” 14T 93,0 (3.66) E, L
Support
Model Code Position 25 Pilot Dia. Pilot Depth 2-bolt 4-bolt Mounting Point
Flange Bolt “R” “S” “T1” “T2” “V”
A, B SAE “A” 2-bolt SAE ∅82,6 (3.25±.001) 8,6/8,1 (.32/.34) .375-16 UNC-2B thd. N/A N/A
G, H ISO 80 ISO ∅80,05 (3.15) 9,0/8,0 (.35/.31) M10 thd. N/A N/A
C, D SAE “B” 2-/4-bolt SAE ∅101,65 (4.002±.001) 12,5/11,5 (.49/.45) .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B
thd. .98" deep
J, K ISO 100 ISO ∅100,05 (3.94) 12,5/11,5 (.49/.45) M12 thd. M12 thd. M12 thd. x 25,0 deep
60 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models
PVM057/063
To mounting face
297,4 92,0
(11.70) ∅ “R” (3.62)
35,0
(1.38)
(4 plcs)
“T2”
“ T1”
309,9
(12.20)
Left hand rotation with Pressure Compensator and
To mounting face SAE 2-/4-bolt “C” adapter flange
Support
Model Code Position 25 Pilot Dia. Pilot Depth 2-bolt 4-bolt Mounting Point
Flange Bolt “R” “S” “T1” “T2” “V”
E, F SAE “C” 2-/4-bolt SAE ∅127,05 (5.002±.001) 15,5/14,5 (.61/.57) 625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B
thd. .98" deep
L, M ISO 125 ISO ∅125,05 (4.92) 15,5/14,5 (.61/.57) M12 thd. M12 thd. M12 thd. x 25,0 deep
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 61
End-ported
Models
PVM074/081
87,0 2X
(3.43)
Outlet gauge Inlet gauge
port "K". See port "K".
options on See option
page 83. on page
83.
42,5 57,0
(1.67) (2.24)
96,8 84,5 182,6
(3.81) (3.33) Drain port "F". See (7.19)
options on page 83.
261,6
114,0 114,0
(10.30)
(4.49) (4.49)
Right hand rotation 278,6
with Load Sensing Control (10.97)
62 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Side-ported
Models
PVM074/081
See pilot flange options on page 77. Lifting point .375-16 UNC thd.
See shaft options starting on page 78. 10,0 (.39) deep with SAE drain
M10 thd. 10,0 (.39) deep with ISO drain
110,0
86,0 Outlet (4.33) 33,0
(3.39) gauge (1.30)
port "K".
See options
on page 83. 16,8
86,0 (.66)
(3.39)
Outlet port
"C". See
options on
65,0 65,0 page 82.
Alt. drain port "F". 181,6
(2.56) (2.56)
See options on page 83. (7.15)
Drain port
92,0 91,0 "F". See 246,6
(3.62) (3.58) options on (9.71)
page 83. 279,6
114,0 114,0
(4.49) (4.49) (11.01)
Right hand rotation 288,0
with Load Sensing Control (11.34)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 63
Thru-drive
Models
PVM074/081
110,0
86,0 2X T1 Outlet gauge (4.33) 33,0
(3.39) port "K". (1.30)
See options
on page 83.
14.5
86,0 (0.57)
(3.39)
Outlet port "C".
See options on
"A2" 45,0 page 82.
Alt. drain port 181,6
(1.77)
"F". See options Inlet gauge (7.15)
on page 83. port "K". 92,0 91,0 246,6
See options (3.62) (3.58) Drain port "F". (9.71)
on page 83. See options 277,6
114,0 114,0 on page 83. (10.93)
(4.49) (4.49) 322.6
Right hand rotation (12.70)
with Load Sensing Control
and 2-bolt“A” flange
64 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models
PVM074/081
Coupling Length Code
Dimensions in millimeters (inches)
68,3 SAE “A,” 9T 64,5 (2.54) A, G
(2.69) SAE “A,” 11T 65,3 (2.57) B, H
“S” 43,3 SAE “B,” 13T 95,3 (3.75) C, J
(1.70) “S” SAE “B-B,” 15T 95,3 (3.75) D, K
SAE “C,” 14T 95,3 (3.75) E, L
SAE “C-C,” 17T 91,8 (3.61) F, M
“R3”
“R3”
“R1” “R2" “R1” “R2”
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 65
Thru-drive
Models
PVM074/081
4X 35,0
(1.38)
“A1”
“T1” 92,0
(3.62)
4X “W”
“T2”
To mtg, face 335,1 “A1”
(13.19)
“A2”
View rotated 90°
Left hand rotation with Pressure Compensator
and ISO or SAE 2-/4-bolt “C” Adapter Flange
66 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
End-ported
Models
PVM098/106
Dimensions in millimeters (inches) Alt. drain port “F”. See options on page 83.
See pilot flange options on page 77. Lifting point .375-16 UNC thd. 10,0 (.39) deep with
SAE drain M10 thd. 10,0 (.39) deep with ISO drain
See shaft options starting on page 78.
Alt. drain port “F”. See
options on page 83.
121,0
(4.76)
2X 95,0
(3.74)
Inlet port “B”.
See options
Outlet port on page 82.
“C”. See
options on
page 82. 162,0
Inlet gauge (6.38)
Outlet gauge port “K”. See
port “K”. See 33,9
options on
options on (1.33)
page 83. 115,5
page 83.
(4.55)
Left hand rotation with Pressure Compensator w/o max adj stop
342,4
(13.48)
357,8
(14.09)
214,6
(8.45)
Load sense port 155,7
170,6
16,4 (6.72) Max. Adj. stop. One “J”. See options (6.13)
(.65) rotation will change on page 83. C/G location
displacement
7,9-8,7 l/min
(2.1-2.3 USgpm)
Inlet port “B”. at 1800 rpm
See options on 107,5 37,0
page 82. (4.23) (1.46)
Outlet port
“C”. See
options on
page 82. 35,5
Inlet gauge (1.40)
port “K”. See
options on Outlet gauge port
page 83. “K”. See options
on page 83.
49,7 57,0 2X 194,5
(1.96) (2.24) (7.66)
107,8 87,3 Drain port “F”.
See options 278,9
(4.24) (3.44) (10.98)
119,0 119,0 on page 83.
(4.69) (4.69) 301,9
(11.89)
Right hand rotation with Load Sensing Control
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 67
Side-ported
Models
PVM098/106
Dimensions in millimeters (inches) Alt. drain port “F”. See options on page 83.
See pilot flange options on page 77. Lifting point .375-16 UNC thd.10,0 (.39) deep with
SAE drain M10 thd. 10,0 (.39) deep with ISO drain
See shaft options starting on page 78.
Alt. drain port “F”. See
options on page 83.
121,0
(4.76)
2X 95,0
(3.74)
37,0
92,5 Outlet gauge 107,5 (1.46)
(3.64) port “K”. See (4.23)
options on
page 83.
35,5
90,0 (1.40)
(3.54) Outlet port “C”. See
options on page 82.
68 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models
PVM098/106
Dimensions in millimeters (inches) Alt. drain port "F". See options on page 83.
Lifting point .375-16 UNC thd. 10,0 (.39) deep with
See pilot flange options on page 77. SAE drain M10 thd. 10,0 (.39) deep with ISO drain
See shaft options starting on page 78. Alt. drain port "F". See
options on page 83.
347,9
(13.70)
121,0
(4.76)
2X 95,0
(3.74)
33,9
(1.33)
Outlet gauge port Inlet gauge port 115,5
"K". See options "K". See options (4.55)
on page 83. on page 83. w/o max adj stop
Left hand rotation 342,4
with Pressure Compensator (13.48)
357,8
(14.09)
90,0
(3.54) 42,0
(1.65)
Outlet port "C".
Alt. drain port "F". See A2* 45,0 See options 2X 194,5
options on page 83. (1.77) on page 82. (7.66)
266,9
98,0 91,0 Drain port "F". (10.51)
Inlet gauge port "K". See (3.86) (3.58) See options
options on page 83. 119,0 119,0 on page 83.
(4.69) (4.69)
Right hand rotation with 2-bolt “A” flange
and Load Sensing Control
*See table on following page.
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 69
Thru-drive
Models
PVM098/106
Coupling Length Code
Dimensions in millimeters (inches)
68,3 SAE “A,” 9T 64,5 (2.54) A, G
(2.69) SAE “A,” 11T 65,3 (2.57) B, H
“S” SAE “B,” 13T 95,3 (3.75) C, J
43,3
Coupling (1.70) “S” SAE “B-B,” 15T 95,3 (3.75) D, K
(see table) SAE “C,” 14T 95,3 (3.75) E, L
SAE “C-C,” 17T 91,8 (3.61) F, M
“R3” “R3”
“R1” “R2”
“R1” “R2”
70 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models
PVM098/106
4X 35,0
(1.38)
“T1” “A1”
92,0
(3.62)
4X “W” Support
mounting points “T2”
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 71
End-ported
Models
PVM131/141
369,4 (14.54)
230,4 (9.07)
131,0
34,0 132,7 (5.16)
(1.34) (5.22) “B” inlet port
172,0
(6.77)
“C”
outlet
port
115,0
(4.53) “K”
“K”
Outlet Inlet
gage gage
port port
Optional drain port “F” Adjustable maximum stop option.
Torque locknut to 37-45 Nm (27-33 lb ft.) Left hand rotation
One turn of screw will change pump with Pressure Compensator
displacement 5,7 cm3/rev (0.35 in3/rev.)
Turn CCW to destroke.
65,0 (2.56) 2 plcs. 55,0 (2.17) 2 plcs. “K” Inlet 132,7 (5.22)
gage port
110,5 (4.35) R.H.
143,5 (5.65) 346,1(13.63) max. length 94,5 (3.72) L.H.
w/o max. adj. stop
111,5 “J” Load sense signal port
(4.39) 122,6 (4.83) 2 plcs.
2 plcs. 180,6 (7.11)
“F2”
“B” inlet
port
“B2” 4 plcs.
55,0
(2.17) 106,0 “K” Inlet “K” Outlet
(4.17) gage port gage port
“C” Outlet
25,0 port
“F3” (0.98) 49,7 (1.95)
“F” drain port 192,6 (7.58) “C2” 4 plcs.
Optional drain 2 plcs. 64,0
port “F” 330,6 (13.02) (2.52)
Lifting point 104,2 91,5
.500-13 UNC-2B thd. (4.10) (3.60)
18,0 (.709) dp. 2 plcs.
Right hand rotation with
Load Sensing Control
72 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Side-ported
Models
PVM131/141
143,5
(5.70) “F2”
A
55,0
(2.17) 106,0
(4.17) A
“F” drain port
70,0 Outlet gage
“F3” 192,6 (7.58) (2.76)
Lifting point “B2” port “K”
Optional drain 2 plcs. 4 plcs. 70,0
.500-13 UNC-2B thd. (2.76)
port “F” 298.6 (11.76)
18.0 (.709) dp. 2 plcs.
95.0
Inlet port “B” (3.74)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 73
Thru-drive
Models
PVM131/141
65,0 280,4
(2.56) 132,7 (11.04)
(5.22)
15,0
(.59) 55,0
(2.16)
55,0 106,0
(2.17) (4.17) 45,0
54,5 (1.77)
(2.15)
11,5 313,6
173,0 (.45) 40,0 (12.35)
(6.81) Inlet gage (1.57)
port “K.” See Alt. drain port “F.” See
192,6 4,0 options on page 83.
(7.58) options on page 83. 100,0 95,0
(3.94) (3.74) (.16)
298,6 Outlet gage port “K.” See
(11.76) SAE .500-13 UNC-2B options on page 83.
305,6
thd. 1.19 deep min. or
(12.03)
Inlet gage port K" ISO M12 x 31.0 deep min. SAE port 116,1 (4.57)
ISO port 150,0 (5.91)
Right Hand Rotation with Load Sensing Control and
Model Code Position 25 “Q1” Thru-drive Flange “Q2” 2-bolt Thread SAE 2-bolt “A” Flange (no adapter)
A, B SAE J744-82-2 .375-16 UNC-2B
∅82.625/82.575 bore thd. 0.80 deep
G, H ISO 3019/2-80A2 M10 thd. x 18,0 deep
∅80.075/80.25 bore
74 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Thru-drive
Models
PVM131/141
Model Code Position 25
Dimensions in millimeters (inches) Coupling Code Description
For SAE “A” pad with a 9T, 16/32 DP, 30° pressure angle,
A involute spline
69,7 (2.74)
For SAE “A” pad with a 11T, 16/32 DP, 30° pressure angle,
B
80,0 involute spline
(3.15) Output shaft 14T 12/24 DP external involute spline
C SAE “B,” 13T, 16/32 DP, 30° pressure angle, involute spline
O-ring (furnished) D SAE “B-B,” 15T, 16/32 DP, 30° pressure angle, involute spline
E SAE “C,” 14T, 12/24 DP, 30° pressure angle, involute spline
F SAE “C-C,” 17T, 12/24 DP, 30° pressure angle, involute spline
G For ISO 80-A2HW pad with a 9T SAE spline
H For ISO 80-A2HW pad with a 11T SAE spline
J For ISO 100-A2/B4HW pad with a 13T SAE spline
K For ISO 100-A2/B4HW pad with a 15T SAE spline
L For ISO 125-A2/B4HW pad with a 14T SAE spline
Coupling (See table) M For ISO 125-A2/B4HW pad with a 17T SAE spline
14,0 (.55)
372,1 (14.65)
“R2” – 2 places
“R4” Support
mounting points
(4 places)
Model Code
Position 25 “R1” Thru-drive Flange “R2” 2-bolt Thread “R3” 4-bolt Thread “R4” Support Mounting Point
SAE J744-101-2 & -4 .500-13 UNC-2B thd. .500-13 UNC-2B thd. .500-13 UNC-2B thd.
C, D ∅101,675/101,625 bore 12,50/11,50 deep 0.98 deep 0.98 deep 0.98 deep
ISO 3019/2-100A2 & B2
J, K M12 thd. x 25,0 deep M12 thd. x 25,0 deep M12 thd. x 25,0 deep
∅100,075/100,025 bore 12,50/11,50 deep
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 75
Thru-drive
Models
PVM131/141
359,6 (14.16)
∅ “S1” 92,0 (3.62) 4 places
“S” Support
mounting points
(4 places)
35,0 (1.38)
4 places
“S3”
4 places
“S2”
372,1
372,1(14.65)
(14.65) 2 places
Model Code
Position 25 “S1” Thru-drive Flange “S2” 2-bolt Thread “S3” 4-bolt Thread “R4” Support Mounting Point
SAE J744-127-2 & -4 .625-11 UNC-2B thd. .500-13 UNC-2B thd. .500-13 UNC-2B thd.
E, F ∅127,075/127,025 bore 15,50/14,50 deep 0.98 deep 0.98 deep 0.98 deep
ISO 3019/2-125A2 & B4
L, M M16 thd. x 25,0 deep M12 thd. x 25,0 deep M12 thd. x 25,0 deep
∅125,075/125,025 bore 15,50/14,50 deep
76 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Mounting Flange
Options
F
L
E K
K
G
A
H
A
45°
∅ J pilot ∅ J pilot
2-bolt or 4-bolt
Series Flange Code Flange Description A E F G H J K L
A SAE J744-16-4 15,88 ∅X XX XX
PVM018 – – – –
(.625)
(XX) (∅X) (Xx) (XX)
PVM020
“B” (special) B SAE J744-25-4 21,81 ∅XX XX XX
PVM045 – – – –
(.859)
XX (∅X) (X) (XX)
PVM050
C SAE J744-101-2 (“B”) 14,3 ∅101,60/101,55 73,0 146,0
PVM057 (.562) – – – – (∅4.000/3.998)
2-bolt (2.874) (5.748)
“B” (special) D ISO 3019/2-100A2HW 14,0 ∅100,00/99,95 70,0 140,0
PVM063 – – – –
(.551) (∅3.937/3.935) (2.756) (5.512)
E SAE J744-127-2 (“C”) 17,4 90,5 181,0 – – ∅127,00/126,95
PVM057 – –
(.685) (3.562) (7.125) (∅5.000/4.998)
PVM063 2-bolt
PVM074 “C” F ISO 3019/2-125A2HW 18,0 90,0 180,0 – – ∅125,00/124,95 – –
PVM081 (.709) (3.543) (7.09) (∅4.921/4.919)
PVM098 G SAE J744-127-4 (“C”) 14,2 57,25 114,50 ∅127,00/126,95
PVM106 4-bolt (.559) – – (2.254) (4.508) (∅5.000/4.998) – –
PVM131 “C”
PVM141 H ISO 3019/2-125B4HW 14,0 ∅125,00/124,95 80,0 160,0
(.551) – – – – (∅4.921/4.919) (3.150) (6.299)
J SAE J744-152-4 (“D”) 20,6 80,82 161,64 ∅152,40/152,35
– – – –
PVM131 4-bolt (.812) (3.182) (6.364) (∅6.000/5.998)
PVM141 “D” K ISO 3019/2-160B4HW 18,0 ∅160,00/159,95 100,0 200,0
– – – –
(.709) (∅6.299/6.297) (3.937) (7.874)
*Flanges for PVM020 and PVM050 are shown on pages 49 and 56, respectively.
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 77
Shaft Options
∅A
78 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Shaft Options
B ∅A
Max. Input
SAE Keyed Shaft Shaft Torque
Model Series Designation Code A B C D E Nm (lb. in.)
SAE J744-16-1 58
01 15,88 (.625 ) 17,73 (.698) 24,0 (.94) 32,0 (1.26) 4,0 (.157)
SAE “A” (517)
SAE J744-19-1 104
02 19,05 (.750) 21,23 (.836) 24,0 (.94) 32,0 (1.26) 4,81 (.189)
SAE “19-1” (918)
PVM018/020
SAE J744-22-1 135
SAE “B” 05 22,22 (.875) 25,12 (.989) 33,0 (1.31) 41,0 (1.61) 6,35 (.250) (1200)
SAE J744-25-1 215
06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250)
SAE “B-B” (1900)
SAE J744-22-1 135
SAE “B” 05 22,22 (.875) 25,12 (.989) 33,0 (1.31) 41,0 (1.61) 6,35 (.250) (1200)
PVM045/050
SAE J744-25-1 215
06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250)
SAE “B-B” (1900)
SAE J744-25-1 215
SAE “B-B” 06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250) (1900)
PVM057/063
SAE J744-32-1 450
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312)
SAE “C” (3980)
SAE J744-32-1 450
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312)
PVM074/081 SAE “C” (3980)
PVM098/106 SAE J744-38-1 765
SAE “C-C” 10 38,10 (1.50) 42,39 (1.67) 54,0 (2.13) 62,0 (2.44) 9,52 (.375) (6770)
SAE J744-32-1 450
09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312)
SAE “C” (3980)
SAE J744-38-1 765
PVM131/141 10 38,10 (1.50) 42,39 (1.67) 54,0 (2.13) 62,0 (2.44) 9,52 (.375)
SAE “C-C” (6770)
SAE J744-44-1 1200
SAE “D” 13 44,45 (1.75) 49,46 (1.95) 67,0 (2.63) 75,0 (2.95) 11,11 (.438) (10,620)
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 79
Shaft Options
D key
E ∅A
Max. Input
ISO Keyed Shaft Shaft Torque
Model Series Designation Code A B C D E Nm (lb. in.)
ISO 3019/2 E20N 15 20 (.787) 8,5 (.335) 36 (1.42) 6 (.236) 22,5 (.886) 113 (1000)
PVM018/020 ISO 3019/2 E25N 16 25 (.984) 8,5 (.335) 42 (1.65) 8 (.315) 28,0 (1.102) 104 (1900)
ISO 3019/2 E25N 17 25 (.984) 10,5 (.413) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
PVM045/050 ISO 3019/2 E25N 17 25 (.984) 10,5 (.413) 42 (1.65) 8 (.315) 28,0 (1.102) 135 (1900)
ISO 3019/2 E25N 17 25 (.984) 10,5 (.413) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)
PVM057/063
ISO 3019/2 E32N 18 32 (1.26) 10,5 (.413) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
PVM074/081 ISO 3019/2 E32N 18 32 (1.26) 10,5 (.413) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
PVM098/106 ISO 3019/2 E40N 19 40 (1.57) 10,5 (.413) 82 (3.23) 12 (.472) 43,0 (1.693) 765 (7700)
ISO 3019/2 E32N 18 32 (1.26) 10,5 (.413) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)
PVM131/141
ISO 3019/2 E40N 19 40 (1.57) 10,5 (.413) 82 (3.23) 12 (.472) 43,0 (1.693) 765 (7700)
(1) ISO 80mm pilot only – B
*Torque of non-thru-drive PVM pump, or combined torque of PVM thru-drive pump and thru-driven pump.
NOTE: In those cases where geometric tolerances of mounting are critical, or where specific tolerance ranges are required and not specified, consult Eaton
Engineering for specific limits.
80 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Input Shaft
Selection Data
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 81
Port Options
82 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Port Options
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 83
Operating
Requirements
HYDRAULIC FLUIDS
Fluid Cleanliness your Eaton Representative for Proper fluid condition is Eaton publication 561 –
The M Series pumps are rated specific duty cycle recom- essential for long and satisfac- “Eaton Guide to Systemic
in anti-wear petroleum fluids mendation. tory life of hydraulic components Contamination Control” –
with a contamination level of Eaton M Series pumps, as and systems. Hydraulic fluid Available from your local Eaton
20/18/13 (Eaton) or ISO 18/13. with any variable displacement must have the correct balance distributor. In this publication,
Operation in fluids with levels piston pumps, will operate with of cleanliness, materials, and filtration and cleanliness levels
more contaminated than this is apparent satisfaction in fluids additives for protection against for extending the life of axial
not recommended. Fluids other up to the rating specified here. wear of components, elevated piston pumps and other system
than petroleum, severe service Experience has shown, however, viscosity and inclusion of air. components are listed. Included
cycles, or temperature extremes that pump and hydraulic system Essential information on the is an excellent discussion of the
are cause for adjustment of life is not optimized with high correct methods for treating selection of products needed to
these codes. Please contact fluid contamination levels (high hydraulic fluid is included in control fluid condition.
ISO cleanliness codes).
84 EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002
Installation and
Start-up
Warning: Care should be taken In those cases where geometric Start-up Procedure Once the pump is started,
that mechanical and hydraulic tolerances of mounting are Make sure the reservoir and it should prime within a few
resonances are avoided in the critical, or where specific toler- circuit are clean and free of seconds. If the pump does not
application of the pump. Such ance ranges are required and dirt/debris prior to filling with prime, check to make sure
resonances can seriously not specified, consult Eaton hydraulic fluid. that there are no restrictions
compromise the life and/or safe Engineering for specific limits. between the reservoir and the
operation of the pump. Fill the reservoir with filtered inlet to the pump, that the pump
Direction of shaft rotation, oil and fill to a level sufficient
viewed from the prime mover is being rotated in the proper
Drive Data enough to prevent vortexing at direction, and that there are no
end, must be as indicated in the suction connection to pump
the model designation on the air leaks in the inlet line and
Mounting attitude can be either inlet. It is good practice to connections. Also check to make
horizontal or vertical, using the pump – either right hand clean the system by flushing
(clockwise) or left hand (counter- sure that trapped air can escape
appropriate case drain ports to and filtering, using an external at the pump outlet.
ensure that the case remains clockwise). slave pump.
full of fluid at all times. Consult Direct coaxial drive through After the pump is primed,
your local Eaton Representative Caution: Before the pump is tighten the loose outlet con-
a flexible coupling is recom- started, fill the case through
if a different arrangement is mended. If drives imposing nections, then operate for five
required. the uppermost drain port with to ten minutes (unloaded) to
radial shaft loads are considered, hydraulic fluid of the type to be
please consult your Eaton remove all trapped air from
used. The case drain line must the circuit.
Representative. be connected directly to the
reservoir and must terminate If the reservoir has a sight gage,
below the oil level. make sure the fluid is clear –
not milky.
EATON Vickers M Series Mobile Variable Displacement Piston Pumps Technical Focus V-PP-MC-0003-E August 2002 85
Eaton Eaton Eaton
14615 Lone Oak Road 20 Rosamond Road 46 New Lane, Havant
Eden Prairie, MN 55344 Footscray Hampshire PO9 2NB
USA Victoria 3011 England
Tel: 952 937-9800 Australia Tel: (44) 23 92 486 451
Fax: 952 974-7722 Tel: (61) 3 9319 8222 Fax: (44) 23 92 487 110
www.hydraulics.eaton.com Fax: (61) 3 9318 5714
Vickers