You are on page 1of 32

o

h tn Intertek

i t c
Salzer Electronics Limited
Samichettipalayam Sw he Bes
Coimbatore - 641 047, INDIA.

Tel: +91 422 4233600/2692531.


Fax: + 91422 2692170.
t o t Cam Operated
Email: salzer@salzergroup.com, sales@salzergroup.com.
Website: www.salzergroup.com Rotary Switches
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Cam Operated Rotary Switches used to perform Make and Break


operation in a sequential way by rotating the switch to different positions.
Contents
The Cam, which closes and opens the contacts, has rotary movement to
Introduction 02
multiple positions, thereby multiple Circuit functions can be controlled.
Construction 04
Further, the flexibility in the switch type selection covering various current /
voltage ratings and options to select the number of contacts, is added Technical Specifications 05
advantage. This ensures that a right switch is chosen for the desired
application. CAM Switches thus offer complete design flexibility to assemble Isolator Switches 06
complex switching programs, contact ratings and customize all switching
applications. Changeover Switches with OFF 07

Moreover the Cam Switches are suitable for AC as well as DC switching Changeover Switches without OFF 08
applications.
Multistep Switches with OFF 09
The basic operating mechanism of Cam Switch is required to suit intended
application coupled with “Quick-Make”, “Quick-Make-Quick-Break” and Multistep Switches without OFF 10
“Spring Return” operating mechanisms are offered to cover wide range
requirements. Instrumentation Selector Switches 11

The Cam Switches offers versatile mounting options in addition to Standard Motor Control Switches 13
Panel/Flush Mounting and other special features like single hole, door
interlocking, padlock, Lock and Key for various needs. The wide option Gang Switches 15
such as type of Knob, Front plate Color and customized marking on the
Marking Plate gives compatible to the panel design and thus eliminates the Control Switches 16
need of the separate label on the panel.
Mountings 17
The superior quality of engineering materials and “Double Butt” contacts
Knobs and Handles 22
with silver bimetal on copper/brass provide stable electrical performance.
The high-grade engineering plastics with high tracking index like Nylon,
Celcon and glass filled polyamide for the components ensures greater Accessories 23
mechanical strength.
Customised Programme 24
Advanced manufacturing processes for Cam Switch components under Ordering Code 25
stringent quality conditions ensures durability, reliability and enhanced life
and safe operations for a very long time.
Breaker Control Switches 26

Installation Procedure - Standard Switches 28

DC Switches 29

02 03
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Cam Operated Rotary Switches used to perform Make and Break


operation in a sequential way by rotating the switch to different positions.
Contents
The Cam, which closes and opens the contacts, has rotary movement to
Introduction 02
multiple positions, thereby multiple Circuit functions can be controlled.
Construction 04
Further, the flexibility in the switch type selection covering various current /
voltage ratings and options to select the number of contacts, is added Technical Specifications 05
advantage. This ensures that a right switch is chosen for the desired
application. CAM Switches thus offer complete design flexibility to assemble Isolator Switches 06
complex switching programs, contact ratings and customize all switching
applications. Changeover Switches with OFF 07

Moreover the Cam Switches are suitable for AC as well as DC switching Changeover Switches without OFF 08
applications.
Multistep Switches with OFF 09
The basic operating mechanism of Cam Switch is required to suit intended
application coupled with “Quick-Make”, “Quick-Make-Quick-Break” and Multistep Switches without OFF 10
“Spring Return” operating mechanisms are offered to cover wide range
requirements. Instrumentation Selector Switches 11

The Cam Switches offers versatile mounting options in addition to Standard Motor Control Switches 13
Panel/Flush Mounting and other special features like single hole, door
interlocking, padlock, Lock and Key for various needs. The wide option Gang Switches 15
such as type of Knob, Front plate Color and customized marking on the
Marking Plate gives compatible to the panel design and thus eliminates the Control Switches 16
need of the separate label on the panel.
Mountings 17
The superior quality of engineering materials and “Double Butt” contacts
Knobs and Handles 22
with silver bimetal on copper/brass provide stable electrical performance.
The high-grade engineering plastics with high tracking index like Nylon,
Celcon and glass filled polyamide for the components ensures greater Accessories 23
mechanical strength.
Customised Programme 24
Advanced manufacturing processes for Cam Switch components under Ordering Code 25
stringent quality conditions ensures durability, reliability and enhanced life
and safe operations for a very long time.
Breaker Control Switches 26

Installation Procedure - Standard Switches 28

DC Switches 29

02 03
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Construction Technical Specifications


Intertek

50/60
S200

M10
690

200
225

200

2.5
55
95
45
78

25

10
70
10
50
6
Conformance to standards :
European : IEC-60947-1 : 1988

2XM5
IEC-60947-3 : 1990

50/60
S125

2.5
690

125
150

125

10
50
10
35
45
78
37
64

25
6
IEC-60947-5 : 1992
Canadian : CSA 22.2 No.14-2010
American : UL 508 (2009)

50/60

2XM5
S100

690

100
125

100

2.5
41
71
33
57

25

Switch life under standard operating conditions: Mechanical 100,000 operations @ 300 cycles / hour, Electrical 10,000 operations at 100 % rated duty for 120 cycles/hour
10
35
10
25
6

S200

175
600

15
25
50
50
-
-
Cam Assembly Contact Assembly

2XM5
50/60
S80

690

100

2.5
80

33
57
22
38

25
80

25

16
6

S125

100
600

10
20
40
50
-
-
Series S, TP, RT and SL Cam Switches incorporate two double break silver alloy contacts per stage at 180 degree
disposition. The AC Switches are “Quick Make-Slow Break” with in-built latching device feature in cam design. The Cam

50/60
RT53

18.5
S63

690

2.5

M5
63
80

22
38

32

20
63

16

10
Switches can be offered for DC applications with additional contacts in series according to the DC switching voltage and

S100

100
600

10
20
40
50
-
-
with suitable duration and the DC Switches are "Quick Make - Quick Break".

50/60
RT40

18.5
S40

2.5

2.5

M5
690

10
40
50

32
15
26

20
40
-150C to 550C

2
Contacts : Double break type AgCdO Operating temp :

S80

600
6

80

10
20
40
50
-
-
Insulation : Glass filled polyamide Operating frequency : 50 to 60Hz
with high tracking index Humidity : 95%, Rh 48 hours

Rated Duty: 8 Hours, Installation, Operation and Maintenance Condition: Suitable for Environment A (for Industrial Application).
50/60
RT32
S32

690

S63
2.5

1.5

M4
1.2
32
40

15
26
11
19

10
32

600

7.5
7.5
6

55

15
30
40
3
S Series TP Series RT Series SL Series
Open Version Touch Proof Touch Proof & Touch Proof &
Rear Termination Screwless Termination

50/60
RT25

S40

600
S25

690

7.5

40

10
20
24
25
32

11
19

13

10
25

1.5

2.5
M4
1.2

2
5
5
6

4
1

RT32
S20/TP20/

S32

600
1.5

7.5
30

10
15
3
3
50/60
RT20

M3.5
690

7.5

5.5

1.5

2.5

0.8
20
25

13

10

20
6

4
1

RT25
S25

600
1.5

7.5
20

10
15
3
3
S16/TP16/

50/60
RT16

M3.5
690

7.5

5.5

1.5

2.5

0.8
16
20

13

10

16

RT 20
TP 20
6

4
1

S20

0.33
600

1.5
20

3
3
5
RT16
TP16

0.33
S16
50/60

600
TP10

1.5

Note :- AC4 Rating = AC3 rating / 2, Star Delta Rating = 60% of AC3 Rating
15
S10

440

0.7
1.5

1
0.7
1.5

3
3
5
M3
0.5
10
12

10
--

--
4

3
50/60

0.33
0.75
S10
TP6

460
440

0.7
1.5
0.7
1.5
M3
0.5
2.2

1.5

10
S6
Available from 6 to 400Amp Available from 6 to 20Amp Available from 16 to 63Amp Available from 6 & 10Amp

1
1
2
--

--
l l l l

4
6
8

3
6

-
Open terminals for
l easy Finger Protection (IP20)
l ‘Finger Protected
l convenient Cage clamp (finger protected)
l
accessibility accessibility (IP20)

Metric
Unit

0.25
0.50
0.75
S6
mm2
mm2
mm2
mm2

460
Nm
KW

KW

KA
Hz
Kv

1
1
V

A
A

-
AC Duty Rating DC Duty Rating

Unit

HP
HP
HP
HP
HP
HP
max

max

A
V
min

min
Category Typical AC Application

Rated Operational Current(Ie) AC21/AC1


Category Typical DC Application

Rated impulse withstand Voltage(Uimp)


AC-1 Non-Inductive or slightly DC-1 Non-Inductive or slightly Inductive Loads,

Rated Uninterrupted Current (Ith)

Rated Fuse Short Circuit Current


Inductive Loads, Resistance Furnaces Resistance Furnaces.

Rated Operational Voltage(Ue)


AC-3 Squirrel Cage otors: starting DC-22 Switching of resistive loads,

Terminal Tightening Torque

3 Phase 120V
240V

240V
480V
600V
HP Rating 1 Phase 120V
switching off motors during running including moderate overloads

Rated Operational Power

Fuse Size (Type gG/gM)

Terminal Cross Section

Terminal Cross Section

CSA/UL Ratings
Short Circuit Capacity
AC23A "3 Ph , 415 V"
IEC/EN Ratings

AC-15 Control of AC electromagnetic loads DC-13 Control of DC electromagnets

Operational Voltage
AC Rating Code
AC Rating Code

Ampere Rating
Rated frequency

Single / Multiple
AC-21A Switching of resistive loads, DC-23 Switching of motor loads or

"3 Ph , 415 V"


including moderate overloads other highly inductive loads

Fine strand
(frequent switching)

AC-23-A Switching of motor loads or other ------ -----

AC3
highly inductive loads (frequent switching)

04 05
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Construction Technical Specifications


Intertek

50/60
S200

M10
690

200
225

200

2.5
55
95
45
78

25

10
70
10
50
6
Conformance to standards :
European : IEC-60947-1 : 1988

2XM5
IEC-60947-3 : 1990

50/60
S125

2.5
690

125
150

125

10
50
10
35
45
78
37
64

25
6
IEC-60947-5 : 1992
Canadian : CSA 22.2 No.14-2010
American : UL 508 (2009)

50/60

2XM5
S100

690

100
125

100

2.5
41
71
33
57

25

Switch life under standard operating conditions: Mechanical 100,000 operations @ 300 cycles / hour, Electrical 10,000 operations at 100 % rated duty for 120 cycles/hour
10
35
10
25
6

S200

175
600

15
25
50
50
-
-
Cam Assembly Contact Assembly

2XM5
50/60
S80

690

100

2.5
80

33
57
22
38

25
80

25

16
6

S125

100
600

10
20
40
50
-
-
Series S, TP, RT and SL Cam Switches incorporate two double break silver alloy contacts per stage at 180 degree
disposition. The AC Switches are “Quick Make-Slow Break” with in-built latching device feature in cam design. The Cam

50/60
RT53

18.5
S63

690

2.5

M5
63
80

22
38

32

20
63

16

10
Switches can be offered for DC applications with additional contacts in series according to the DC switching voltage and

S100

100
600

10
20
40
50
-
-
with suitable duration and the DC Switches are "Quick Make - Quick Break".

50/60
RT40

18.5
S40

2.5

2.5

M5
690

10
40
50

32
15
26

20
40
-150C to 550C

2
Contacts : Double break type AgCdO Operating temp :

S80

600
6

80

10
20
40
50
-
-
Insulation : Glass filled polyamide Operating frequency : 50 to 60Hz
with high tracking index Humidity : 95%, Rh 48 hours

Rated Duty: 8 Hours, Installation, Operation and Maintenance Condition: Suitable for Environment A (for Industrial Application).
50/60
RT32
S32

690

S63
2.5

1.5

M4
1.2
32
40

15
26
11
19

10
32

600

7.5
7.5
6

55

15
30
40
3
S Series TP Series RT Series SL Series
Open Version Touch Proof Touch Proof & Touch Proof &
Rear Termination Screwless Termination

50/60
RT25

S40

600
S25

690

7.5

40

10
20
24
25
32

11
19

13

10
25

1.5

2.5
M4
1.2

2
5
5
6

4
1

RT32
S20/TP20/

S32

600
1.5

7.5
30

10
15
3
3
50/60
RT20

M3.5
690

7.5

5.5

1.5

2.5

0.8
20
25

13

10

20
6

4
1

RT25
S25

600
1.5

7.5
20

10
15
3
3
S16/TP16/

50/60
RT16

M3.5
690

7.5

5.5

1.5

2.5

0.8
16
20

13

10

16

RT 20
TP 20
6

4
1

S20

0.33
600

1.5
20

3
3
5
RT16
TP16

0.33
S16
50/60

600
TP10

1.5

Note :- AC4 Rating = AC3 rating / 2, Star Delta Rating = 60% of AC3 Rating
15
S10

440

0.7
1.5

1
0.7
1.5

3
3
5
M3
0.5
10
12

10
--

--
4

3
50/60

0.33
0.75
S10
TP6

460
440

0.7
1.5
0.7
1.5
M3
0.5
2.2

1.5

10
S6
Available from 6 to 400Amp Available from 6 to 20Amp Available from 16 to 63Amp Available from 6 & 10Amp

1
1
2
--

--
l l l l

4
6
8

3
6

-
Open terminals for
l easy Finger Protection (IP20)
l ‘Finger Protected
l convenient Cage clamp (finger protected)
l
accessibility accessibility (IP20)

Metric
Unit

0.25
0.50
0.75
S6
mm2
mm2
mm2
mm2

460
Nm
KW

KW

KA
Hz
Kv

1
1
V

A
A

-
AC Duty Rating DC Duty Rating

Unit

HP
HP
HP
HP
HP
HP
max

max

A
V
min

min
Category Typical AC Application

Rated Operational Current(Ie) AC21/AC1


Category Typical DC Application

Rated impulse withstand Voltage(Uimp)


AC-1 Non-Inductive or slightly DC-1 Non-Inductive or slightly Inductive Loads,

Rated Uninterrupted Current (Ith)

Rated Fuse Short Circuit Current


Inductive Loads, Resistance Furnaces Resistance Furnaces.

Rated Operational Voltage(Ue)


AC-3 Squirrel Cage otors: starting DC-22 Switching of resistive loads,

Terminal Tightening Torque

3 Phase 120V
240V

240V
480V
600V
HP Rating 1 Phase 120V
switching off motors during running including moderate overloads

Rated Operational Power

Fuse Size (Type gG/gM)

Terminal Cross Section

Terminal Cross Section

CSA/UL Ratings
Short Circuit Capacity
AC23A "3 Ph , 415 V"
IEC/EN Ratings

AC-15 Control of AC electromagnetic loads DC-13 Control of DC electromagnets

Operational Voltage
AC Rating Code
AC Rating Code

Ampere Rating
Rated frequency

Single / Multiple
AC-21A Switching of resistive loads, DC-23 Switching of motor loads or

"3 Ph , 415 V"


including moderate overloads other highly inductive loads

Fine strand
(frequent switching)

AC-23-A Switching of motor loads or other ------ -----

AC3
highly inductive loads (frequent switching)

04 05
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Isolator Switches Changeover Switches with OFF


Isolators are ON-OFF Switches to isolate the power to a particular area of operation. The Isolator Switches are Changeover Switches also called Double Throw Switches are available with OFF and without OFF. These are used
offered in a wide range from 1 Pole to 12 Poles. Isolators with spring return upto 4 Poles are available to energise to operate two different circuits with different number of inputs and outputs. Changeover Switches without Jumpers
circuits. Isolators with pre-close contacts are used for safety circuits and for connecting neutral and earth lines. (potential free contacts) are used to connect two different circuits from two different sources with two different
Isolators are generally rated for AC1/AC21 while for motor applications they need to be rated for AC3/AC23A duty. operating voltages or any other incompatible lines. All contacts by default are “Break Before Make” (BBM) type to
avoid overlapping of different circuits. However, for overlapping changeover contacts. “Make Before Break” (MBB)
Applications: Switching of main/control and instrumentation circuits motor ON-OFF and other special application type are offered against specific requirements.
circuits.
Application: Power Supply to Generator Changeover, Auto/Manual Changeover, Standby/Remote Changeover and
other special application circuits. Mainly used in Distribution Panels, UPS etc.
Connecting Diagram
Changeover with Centre OFF
1 3 5 7 9 11 13 15 17 19 21 23
Connecting Diagram Without Jumper
A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 2 4 6 8 10 12

2 4 6 8 10 12 14 16 18 20 22 24
1 to 12 pole 1 2 3 4 5 6 7 8 1 3 5 7 9 11
1 to 8 Pole 1 to 3 Pole
Stayput Stayput
0 0
OFF ON OFF
1 2
Script Plate ON OFF 1 2
ON ON
Marking
0
OFF
60 Degree No of 90 Degree
Description Description
60 Degree 90 Degree 90 Degree Complete Rotation No of Programme Code Stages Programme Code
Description
Stages 1 Pole 61025 1 1 Pole 61151
Programme Code Programme Code Programme Code
2 Pole 61026 2 2 Pole 61152
1 Pole 61001 61191 61195 1 3 Pole 61027 3 3 Pole 61153
2 Pole 61002 61192 61198 1 4 Pole 61028 4 4 Pole 61154
3 Pole 61003 61199 61197 2 5 Pole 61029 5 - -
4 Pole 61004 61194 61196 2 6 Pole 61030 6 - -
5 Pole 61005 - - 3 7 Pole 61031 7 - -
8 Pole 61032 8 - -
6 Pole 61006 61906 - 3
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400Amps.
7 Pole 61007 - - 4
8 Pole 61008 - - 4 Spring Return
9 Pole 61009 - - 5 0
Spring return to "0"
0
# Spring return from 1 to "0"
1 2 450 900
10 Pole 61010 - - 5 1
2
11 Pole 61011 - - 6
12 Pole 61012 - - 6
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 25, 20, 32, 40, 63, 80, 100, 125, 200 and 400Amps. 45 Degree Spring Return to “ 0” No of Spring Return from 1 to “ 0”
Description Programme Code Stages Description Programme Code
Isolators with Pre-close Contact Spring Return Isolators 45 Degree 1 Pole 61361 1 1 Pole 61364
2 Pole 61362 2 2 Pole 61365
1 3 5 7 9 1 3 5 7
Spring return to OFF
1 3 5 7 3 Pole 61363 3 3 Pole 61369
0
Feasible ampere rating for S, TP and RT Series : 16, 20, 25, and 32Amps. Feasible ampere rating for S, TP and RT Series : 16, 20, 25, and 32Amps.
90
ON 450
OFF S
T
Stayput without Jumper
OFF
A Spring return to "0"
R 0 0
T 1 2
1 2
2 4 6 8 10 2 4 6 8 2 4 6 8
4 to 5 Pole 61194 1 to 4 Pole

Programme No of Programme No of 60 Degree Stayput without Jumper No of 45 Degree Spring Return without Jumper
Description Description
Code Stages Code Stages Stages
Description Programme Code Description Programme Code
4 Pole - 1 Pole Preclose 61194 2 1 Pole Spring Return 61351 1 1 Pole 1 Pole
61625 1 61761
4 Pole - 3 Pole Preclose 61904 2 2 Pole Spring Return 61352 1 without Jumper without Jumper
5 Pole - 3 Pole Preclose 61905 3 3 Pole Spring Return 61353 2 2 Pole 2 Pole
without Jumper 61626 2 without Jumper 61762
3 Pole with Neutral Terminal 61178 2 4 Pole Spring Return 61354 2
3 Pole
Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40, 63, 80, 100, 125, Feasible ampere rating for S, TP and RT Series: 16, 20, 25and 32Amps. without Jumper 61627 3 - -
200 and 400Amps.
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 Amps. Feasible ampere rating for S, TP and RT Series : 16, 20, 25, 32Amps.

06 07
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Isolator Switches Changeover Switches with OFF


Isolators are ON-OFF Switches to isolate the power to a particular area of operation. The Isolator Switches are Changeover Switches also called Double Throw Switches are available with OFF and without OFF. These are used
offered in a wide range from 1 Pole to 12 Poles. Isolators with spring return upto 4 Poles are available to energise to operate two different circuits with different number of inputs and outputs. Changeover Switches without Jumpers
circuits. Isolators with pre-close contacts are used for safety circuits and for connecting neutral and earth lines. (potential free contacts) are used to connect two different circuits from two different sources with two different
Isolators are generally rated for AC1/AC21 while for motor applications they need to be rated for AC3/AC23A duty. operating voltages or any other incompatible lines. All contacts by default are “Break Before Make” (BBM) type to
avoid overlapping of different circuits. However, for overlapping changeover contacts. “Make Before Break” (MBB)
Applications: Switching of main/control and instrumentation circuits motor ON-OFF and other special application type are offered against specific requirements.
circuits.
Application: Power Supply to Generator Changeover, Auto/Manual Changeover, Standby/Remote Changeover and
other special application circuits. Mainly used in Distribution Panels, UPS etc.
Connecting Diagram
Changeover with Centre OFF
1 3 5 7 9 11 13 15 17 19 21 23
Connecting Diagram Without Jumper
A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 2 4 6 8 10 12

2 4 6 8 10 12 14 16 18 20 22 24
1 to 12 pole 1 2 3 4 5 6 7 8 1 3 5 7 9 11
1 to 8 Pole 1 to 3 Pole
Stayput Stayput
0 0
OFF ON OFF
1 2
Script Plate ON OFF 1 2
ON ON
Marking
0
OFF
60 Degree No of 90 Degree
Description Description
60 Degree 90 Degree 90 Degree Complete Rotation No of Programme Code Stages Programme Code
Description
Stages 1 Pole 61025 1 1 Pole 61151
Programme Code Programme Code Programme Code
2 Pole 61026 2 2 Pole 61152
1 Pole 61001 61191 61195 1 3 Pole 61027 3 3 Pole 61153
2 Pole 61002 61192 61198 1 4 Pole 61028 4 4 Pole 61154
3 Pole 61003 61199 61197 2 5 Pole 61029 5 - -
4 Pole 61004 61194 61196 2 6 Pole 61030 6 - -
5 Pole 61005 - - 3 7 Pole 61031 7 - -
8 Pole 61032 8 - -
6 Pole 61006 61906 - 3
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400Amps.
7 Pole 61007 - - 4
8 Pole 61008 - - 4 Spring Return
9 Pole 61009 - - 5 0
Spring return to "0"
0
# Spring return from 1 to "0"
1 2 450 900
10 Pole 61010 - - 5 1
2
11 Pole 61011 - - 6
12 Pole 61012 - - 6
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 25, 20, 32, 40, 63, 80, 100, 125, 200 and 400Amps. 45 Degree Spring Return to “ 0” No of Spring Return from 1 to “ 0”
Description Programme Code Stages Description Programme Code
Isolators with Pre-close Contact Spring Return Isolators 45 Degree 1 Pole 61361 1 1 Pole 61364
2 Pole 61362 2 2 Pole 61365
1 3 5 7 9 1 3 5 7
Spring return to OFF
1 3 5 7 3 Pole 61363 3 3 Pole 61369
0
Feasible ampere rating for S, TP and RT Series : 16, 20, 25, and 32Amps. Feasible ampere rating for S, TP and RT Series : 16, 20, 25, and 32Amps.
90
ON 450
OFF S
T
Stayput without Jumper
OFF
A Spring return to "0"
R 0 0
T 1 2
1 2
2 4 6 8 10 2 4 6 8 2 4 6 8
4 to 5 Pole 61194 1 to 4 Pole

Programme No of Programme No of 60 Degree Stayput without Jumper No of 45 Degree Spring Return without Jumper
Description Description
Code Stages Code Stages Stages
Description Programme Code Description Programme Code
4 Pole - 1 Pole Preclose 61194 2 1 Pole Spring Return 61351 1 1 Pole 1 Pole
61625 1 61761
4 Pole - 3 Pole Preclose 61904 2 2 Pole Spring Return 61352 1 without Jumper without Jumper
5 Pole - 3 Pole Preclose 61905 3 3 Pole Spring Return 61353 2 2 Pole 2 Pole
without Jumper 61626 2 without Jumper 61762
3 Pole with Neutral Terminal 61178 2 4 Pole Spring Return 61354 2
3 Pole
Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40, 63, 80, 100, 125, Feasible ampere rating for S, TP and RT Series: 16, 20, 25and 32Amps. without Jumper 61627 3 - -
200 and 400Amps.
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 Amps. Feasible ampere rating for S, TP and RT Series : 16, 20, 25, 32Amps.

06 07
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Changeover Switches without OFF Multistep Switches with OFF


Connecting Diagram Without Jumper Multi-Step Switches also called Pole-Way Switches, are available with OFF and without OFF. Multi-Step Switches
A1 B1 C1 D1 E1 F1 G1 H1 J1 K1 L1 M1 2 4 6 8 10 12 14 16
connect different circuits to a common supply or vice-versa. Multi-Step Switches with 1 Pole, 2 Poles and 3 Poles
A2 B2 C2 D2 E2 F2 G2 H2 J2 K2 L2 M2
are popular for 1-Phase, 2-Phase and 3-Phase supply.

Applications: As Tap Changing Switch for Transformer/Stabiliser and other special application circuits.
1 2 3 4 5 6 7 8 9 10 11 12 1 3 5 7 9 11 13 15

1 to 12 Pole 1 to 4 Pole Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
No Operating Quadrant Stages

61059 1 Pole -2 Way 2 Way 1


Stayput
0
0 60
A1 B1 C1 D1
61079 2 Pole-2 Way 1 2
2 1 A2 2 B2 3 C2 4 D2
1 1 61099 3 Pole-2 Way 3
2 1 2 61130 4 Pole-2 Way 1 to 4 Pole 4
2 2

61060 1 Pole-3 Way 3 Way 0 2


1 OFF 90
A3 1 A1 B3 2 B1 C3 3 C1 D3 4 D1
61080 2 Pole-3 Way 3
3 1
90 Degree Complete Rotation No of 60 Degree No of 60 Degree No of
61100 3 Pole-3 Way 5
Description Programme Code Stages Description Programme Code Stages Description Programme Code Stages 2 A2 B2 C2 D2
61131 4 Pole-3 Way 1 to 4 Pole 6
1 Pole 61037 1 5 Pole 61041 5 1 Pole 60177 1
61061 1 Pole-4 Way 4 Way 2
2 Pole 61038 2 6 Pole 61042 6 2 Pole 60178 2 0 60
0
A1 B1 C1 D1
1
3 Pole 61039 3 7 Pole 61043 7 3 Pole 60179 3 61081 2 Pole-4 Way 1 2 3 4 4
4 Pole 61040 4 8 Pole 61044 8 4 Pole 60180 4 A4 A2 B4 B2 C4 C2 D4 D2
61101 3 Pole-4 Way 4 2
A3 B3 C3 D3
6
3
- - - 9 Pole 61045 9 - - - 61132 4 Pole-4 Way 1 to 4 Pole 8
- - - 10 Pole 61046 10 - - -
5 Way
- - - 11 Pole 61047 11 - - - 61062 1 Pole-5 Way 0 60
0 A5 A1 B5 B1 C5 C1 3
- - - 12 Pole 61048 12 - - - 5 1
1 2 3
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400 Amps.
61082 2 Pole-5 Way A4 A2 B4 B2 C4 C2 5
4 2
3
61102 3 Pole-5 Way A3 B3 1 to 3 Pole C3 8
Spring Return
6 Way
Spring return to "1" 61063 1 Pole-6 Way 0 45
0 A1 B1 C1 3
1 1
2 A6 1 A2 B6 2 B2 C6 3 C2
61083 2 Pole-6 Way 6 2 6
3 A5 B5 B3 C5
5
4 A3 C3
61103 3 Pole-6 Way A4 B4
1 to 3 Pole C4 9

7 Way
45 Degree Spring Return No of 0
45
0
A7 A1 B7 B1
7
Description Programme Code Stages 61064 1 Pole-7 Way 1
A6 B6 2 B2 4
6 2
1 A2

1 Pole 61371 1 61084 2 Pole-7 Way 5


4
3 A5 A3 B5 B3 7
2 Pole 61372 2 A4 1 to 2 Pole B4

3 Pole 61373 3 8 Way A1


0
0 30
Feasible ampere rating for S, TP and RT Series: 16, 20, 25, and 32Amps. 1 A2
2
61065 1 Pole-8 Way 3 1 A3 4
8 4 A4
A8
Stayput without Jumper 7 6 5
A7 A5
A6
Spring return to "1"
1 1
2
9 Way 0 A1
0 30
1 A2
2 2 2
61066 1 Pole-9 Way 9 3 A9 1 A3
5
8 4
1 A8 A4
7 6 5
A7 A5
A6
90 Degree Stayput without Jumper No of 45 Degree Spring return without Jumper
Description Programme Code Stages Description Programme Sode 10 Way A1
0
0 30
1 A10 A2
1 Pole 1 Pole 10 2
61637 1 without Jumper 61771 61067 1 Pole-10 Way A9 1 A3
5
without Jumper 9
4
3
8 A8 A4
7 6 5
2 Pole A7 A5
without Jumper 61638 2 - - A6

3 Pole 11 Way
without Jumper 61639 3 - - 0 30
0 A11 A1
11 1 A10 A2
10 2
4 Pole 61068 1 Pole-11 Way 9 3 A9 1 A3 6
without Jumper 61640 4 - - 8 4
7 6 5 A8 A4
A7 A5
Feasible ampere rating for S, TP and RT Series : Feasible ampere rating for S, TP and RT Series : A6
6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400Amps. 16, 20, 25, and 32Amps.

08 09
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Changeover Switches without OFF Multistep Switches with OFF


Connecting Diagram Without Jumper Multi-Step Switches also called Pole-Way Switches, are available with OFF and without OFF. Multi-Step Switches
A1 B1 C1 D1 E1 F1 G1 H1 J1 K1 L1 M1 2 4 6 8 10 12 14 16
connect different circuits to a common supply or vice-versa. Multi-Step Switches with 1 Pole, 2 Poles and 3 Poles
A2 B2 C2 D2 E2 F2 G2 H2 J2 K2 L2 M2
are popular for 1-Phase, 2-Phase and 3-Phase supply.

Applications: As Tap Changing Switch for Transformer/Stabiliser and other special application circuits.
1 2 3 4 5 6 7 8 9 10 11 12 1 3 5 7 9 11 13 15

1 to 12 Pole 1 to 4 Pole Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
No Operating Quadrant Stages

61059 1 Pole -2 Way 2 Way 1


Stayput
0
0 60
A1 B1 C1 D1
61079 2 Pole-2 Way 1 2
2 1 A2 2 B2 3 C2 4 D2
1 1 61099 3 Pole-2 Way 3
2 1 2 61130 4 Pole-2 Way 1 to 4 Pole 4
2 2

61060 1 Pole-3 Way 3 Way 0 2


1 OFF 90
A3 1 A1 B3 2 B1 C3 3 C1 D3 4 D1
61080 2 Pole-3 Way 3
3 1
90 Degree Complete Rotation No of 60 Degree No of 60 Degree No of
61100 3 Pole-3 Way 5
Description Programme Code Stages Description Programme Code Stages Description Programme Code Stages 2 A2 B2 C2 D2
61131 4 Pole-3 Way 1 to 4 Pole 6
1 Pole 61037 1 5 Pole 61041 5 1 Pole 60177 1
61061 1 Pole-4 Way 4 Way 2
2 Pole 61038 2 6 Pole 61042 6 2 Pole 60178 2 0 60
0
A1 B1 C1 D1
1
3 Pole 61039 3 7 Pole 61043 7 3 Pole 60179 3 61081 2 Pole-4 Way 1 2 3 4 4
4 Pole 61040 4 8 Pole 61044 8 4 Pole 60180 4 A4 A2 B4 B2 C4 C2 D4 D2
61101 3 Pole-4 Way 4 2
A3 B3 C3 D3
6
3
- - - 9 Pole 61045 9 - - - 61132 4 Pole-4 Way 1 to 4 Pole 8
- - - 10 Pole 61046 10 - - -
5 Way
- - - 11 Pole 61047 11 - - - 61062 1 Pole-5 Way 0 60
0 A5 A1 B5 B1 C5 C1 3
- - - 12 Pole 61048 12 - - - 5 1
1 2 3
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400 Amps.
61082 2 Pole-5 Way A4 A2 B4 B2 C4 C2 5
4 2
3
61102 3 Pole-5 Way A3 B3 1 to 3 Pole C3 8
Spring Return
6 Way
Spring return to "1" 61063 1 Pole-6 Way 0 45
0 A1 B1 C1 3
1 1
2 A6 1 A2 B6 2 B2 C6 3 C2
61083 2 Pole-6 Way 6 2 6
3 A5 B5 B3 C5
5
4 A3 C3
61103 3 Pole-6 Way A4 B4
1 to 3 Pole C4 9

7 Way
45 Degree Spring Return No of 0
45
0
A7 A1 B7 B1
7
Description Programme Code Stages 61064 1 Pole-7 Way 1
A6 B6 2 B2 4
6 2
1 A2

1 Pole 61371 1 61084 2 Pole-7 Way 5


4
3 A5 A3 B5 B3 7
2 Pole 61372 2 A4 1 to 2 Pole B4

3 Pole 61373 3 8 Way A1


0
0 30
Feasible ampere rating for S, TP and RT Series: 16, 20, 25, and 32Amps. 1 A2
2
61065 1 Pole-8 Way 3 1 A3 4
8 4 A4
A8
Stayput without Jumper 7 6 5
A7 A5
A6
Spring return to "1"
1 1
2
9 Way 0 A1
0 30
1 A2
2 2 2
61066 1 Pole-9 Way 9 3 A9 1 A3
5
8 4
1 A8 A4
7 6 5
A7 A5
A6
90 Degree Stayput without Jumper No of 45 Degree Spring return without Jumper
Description Programme Code Stages Description Programme Sode 10 Way A1
0
0 30
1 A10 A2
1 Pole 1 Pole 10 2
61637 1 without Jumper 61771 61067 1 Pole-10 Way A9 1 A3
5
without Jumper 9
4
3
8 A8 A4
7 6 5
2 Pole A7 A5
without Jumper 61638 2 - - A6

3 Pole 11 Way
without Jumper 61639 3 - - 0 30
0 A11 A1
11 1 A10 A2
10 2
4 Pole 61068 1 Pole-11 Way 9 3 A9 1 A3 6
without Jumper 61640 4 - - 8 4
7 6 5 A8 A4
A7 A5
Feasible ampere rating for S, TP and RT Series : Feasible ampere rating for S, TP and RT Series : A6
6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125, 200 and 400Amps. 16, 20, 25, and 32Amps.

08 09
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Multistep Switches without OFF Instrumentation Selector Switches


Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of The Instrumentation Selector Switches help to:
No Operating Quadrant Stages l Measure currents in different circuits with a current transformer a single analog ammeter and a switch
l Measure voltages between phases and phase and neutral with one voltmeter and a switch
61049 1 Pole - 3 Way 3 Way 2
l Measure voltages and currents of a circuit with one voltmeter one ammeter and a single switch
61069 2 Pole - 3 Way 0 A1 B1 C1 D1 E1 F1 3
1 60
61089 3 Pole - 3 Way A2 B2 C2 D2 E2 F2 5
2
1 2 3 4 5 6 Voltmeter Selector Switches
61120 4 Pole - 3 Way 3 6
A3 B3 C3 D3 E3 F3
61124 5 Pole - 3 Way 8 Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
1 to 6 Pole
61126 6 Pole - 3 Way 9 No Operating Quadrant Stages
61050 1 Pole - 4 Way 4 Way 0 A1 B1 C1 D1 2
1 90
OFF 900
61070 2 Pole - 4 Way 4 R
4 2 A4 1 A2 B4 2 B2 C4 3 C2 D4 4 D2 V V
61312 3 - Phase Line Y V
61090 3 Pole - 4 Way 6 BR RY
B 2
3 to Line
61121 4 Pole - 4 Way A3 B3 1 to 4 Pole C3 D3 8 YB
R Y B
A1 B1 C1 D1
61051 1 Pole - 5 Way 5 Way 1 90
0 3
A2 B2 C2 D2 45
0

61071 2 Pole - 5 Way 2


1 2 3 4 5 61313 3 - Phase Line to RY
OFF
RN
61091 3 Pole - 5 Way 5
4
3 A5 A3 B5 B3 C5 C3 D5 D3 8 Line & Line to YB YN 3
BN R
61122 4 Pole - 5 Way A4 B4 1 to 4 Pole C4 D4 10 Neutral BR
Y
V1 V2
A1 B1 C1 B V
61052 1 Pole - 6 Way 6 Way 600 3 N
1
6 2 A6 A2 B6 B2 C6 C2
61072 2 Pole - 6 Way 1 2 3 6 61314 3 - Phase Line to RY 600

5 3 A5 A3 B5 B3 C5 C3 Line, Line to BN YB R Y B N
61092 3 Pole - 6 Way 4
9 3
A4 B4 1 to 3 Pole C4 Neutral & YN BR
RN
Without OFF
A1 B1 C1
61053 1 Pole - 7 Way 7 Way 1 45
0
A2 B2 C2 4
2 R
61073 2 Pole - 7 Way 7 3 A7 1 A3 B7 2 B3 C7 3 C3 7 OFF 450
Y
RY RN V V
6
5
4
A6 A4 B4 C4
61317 3 - Phase Line to B V
61093 3 Pole - 7 Way B6 C6
11 YB 3
A5 B5 1 to 3 Pole C5 Line & L1 to N N
BR

8 Way A1 B1 C1 R Y B N
61054 1 Pole - 8 Way 8
1 45
0
A8 A2 B8 B2 C8 C2 4
2 R L1
61074 2 Pole - 8 Way 7 3 A7 1 A3 B7 2 B3 C7 3 C3 8 45
0
Source 1 Y L2 Source 2
OFF
6 4 RY L1L2 B L3
5 A6 A4 B6 B4 C6 C4 61318 3 - Phase Line to
61094 3 Pole - 8 Way A5 B5 1 to 3 Pole C5 12 YB L2L3 4
Line 2 Sources BR L3L1 R Y B L1 L2 L3
9 Way A1 A2 V1 V2
1 2 300 V
3 A3
61055 1 Pole - 9 Way 4 1 A4 5 0
R
5 OFF 90
9
A5 Y
8 7 6 A9
A8 A7 A6 61311 3 - Phase Line to B V V
BN RN
N
V 2
Neutral
10 Way 300 A1 A2 YN
1 2 R Y B N
3 A3
61056 1 Pole - 10 Way 10 4
5
A10 1 A4 5
9
A5 RY 60
0
R
8 7 6 A9 61319 3 - Phase Line to YB Y
A8 A7 A6 V V
Line B V 2
11 Way 30
0 A1 A2 Without OFF BR
1 2 R Y B
11 3 A11 A3
61057 1 Pole - 11 Way 10 4 A10 1 A4 6
9 5
A5 Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps.
8 7 6 A9
A8 A7 A6
Voltmeter and Ammeter Selector Switches
12 Way 300 A12 A1 A2
12 1 2 A11 A3 Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
11 3
61058 1 Pole - 12 Way 10 4 A10 1 A4 6 No Operating Quadrant Stages
9 5 A5
8 7 6 A9
L1
A8 A7 A6 900 A
OFF L2 A
61336 3 Voltages A
Line - Line & 3 1 L3 5
Multistep Switches without Jumper 3 Currents A V V
2 L2 B Y R V
3 Way 600 2 L1 L3
1
61649 1 Pole - 3 Way 2 L1
without OFF 1 3 4 5 3 1 90
0

L2 A A
without Jumper
3 61337 4 Voltages L3
A
6 & 4 2
N 6
V V
3 Currents 3
V
1 Pole - 4 Way A
4 Way 6 L1L2L3 N B Y R
2 10 2
61650 without OFF 1 900
L1
without Jumper 1 3 4 5 8 7 9 11 12 13 16 15 OFF 900 A A
4 2 61338 3 Voltages L2 A
61670 2 Pole - 4 Way 14
4 Line to Neutral & 3 1
L3
5
3
1 to 2 Pole V N
without OFF 3 Currents V
2 A
without Jumper L1 L2 L3 B Y R

Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125 and 200 Amps. Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps.

10 11
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Multistep Switches without OFF Instrumentation Selector Switches


Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of The Instrumentation Selector Switches help to:
No Operating Quadrant Stages l Measure currents in different circuits with a current transformer a single analog ammeter and a switch
l Measure voltages between phases and phase and neutral with one voltmeter and a switch
61049 1 Pole - 3 Way 3 Way 2
l Measure voltages and currents of a circuit with one voltmeter one ammeter and a single switch
61069 2 Pole - 3 Way 0 A1 B1 C1 D1 E1 F1 3
1 60
61089 3 Pole - 3 Way A2 B2 C2 D2 E2 F2 5
2
1 2 3 4 5 6 Voltmeter Selector Switches
61120 4 Pole - 3 Way 3 6
A3 B3 C3 D3 E3 F3
61124 5 Pole - 3 Way 8 Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
1 to 6 Pole
61126 6 Pole - 3 Way 9 No Operating Quadrant Stages
61050 1 Pole - 4 Way 4 Way 0 A1 B1 C1 D1 2
1 90
OFF 900
61070 2 Pole - 4 Way 4 R
4 2 A4 1 A2 B4 2 B2 C4 3 C2 D4 4 D2 V V
61312 3 - Phase Line Y V
61090 3 Pole - 4 Way 6 BR RY
B 2
3 to Line
61121 4 Pole - 4 Way A3 B3 1 to 4 Pole C3 D3 8 YB
R Y B
A1 B1 C1 D1
61051 1 Pole - 5 Way 5 Way 1 90
0 3
A2 B2 C2 D2 45
0

61071 2 Pole - 5 Way 2


1 2 3 4 5 61313 3 - Phase Line to RY
OFF
RN
61091 3 Pole - 5 Way 5
4
3 A5 A3 B5 B3 C5 C3 D5 D3 8 Line & Line to YB YN 3
BN R
61122 4 Pole - 5 Way A4 B4 1 to 4 Pole C4 D4 10 Neutral BR
Y
V1 V2
A1 B1 C1 B V
61052 1 Pole - 6 Way 6 Way 600 3 N
1
6 2 A6 A2 B6 B2 C6 C2
61072 2 Pole - 6 Way 1 2 3 6 61314 3 - Phase Line to RY 600

5 3 A5 A3 B5 B3 C5 C3 Line, Line to BN YB R Y B N
61092 3 Pole - 6 Way 4
9 3
A4 B4 1 to 3 Pole C4 Neutral & YN BR
RN
Without OFF
A1 B1 C1
61053 1 Pole - 7 Way 7 Way 1 45
0
A2 B2 C2 4
2 R
61073 2 Pole - 7 Way 7 3 A7 1 A3 B7 2 B3 C7 3 C3 7 OFF 450
Y
RY RN V V
6
5
4
A6 A4 B4 C4
61317 3 - Phase Line to B V
61093 3 Pole - 7 Way B6 C6
11 YB 3
A5 B5 1 to 3 Pole C5 Line & L1 to N N
BR

8 Way A1 B1 C1 R Y B N
61054 1 Pole - 8 Way 8
1 45
0
A8 A2 B8 B2 C8 C2 4
2 R L1
61074 2 Pole - 8 Way 7 3 A7 1 A3 B7 2 B3 C7 3 C3 8 45
0
Source 1 Y L2 Source 2
OFF
6 4 RY L1L2 B L3
5 A6 A4 B6 B4 C6 C4 61318 3 - Phase Line to
61094 3 Pole - 8 Way A5 B5 1 to 3 Pole C5 12 YB L2L3 4
Line 2 Sources BR L3L1 R Y B L1 L2 L3
9 Way A1 A2 V1 V2
1 2 300 V
3 A3
61055 1 Pole - 9 Way 4 1 A4 5 0
R
5 OFF 90
9
A5 Y
8 7 6 A9
A8 A7 A6 61311 3 - Phase Line to B V V
BN RN
N
V 2
Neutral
10 Way 300 A1 A2 YN
1 2 R Y B N
3 A3
61056 1 Pole - 10 Way 10 4
5
A10 1 A4 5
9
A5 RY 60
0
R
8 7 6 A9 61319 3 - Phase Line to YB Y
A8 A7 A6 V V
Line B V 2
11 Way 30
0 A1 A2 Without OFF BR
1 2 R Y B
11 3 A11 A3
61057 1 Pole - 11 Way 10 4 A10 1 A4 6
9 5
A5 Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps.
8 7 6 A9
A8 A7 A6
Voltmeter and Ammeter Selector Switches
12 Way 300 A12 A1 A2
12 1 2 A11 A3 Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
11 3
61058 1 Pole - 12 Way 10 4 A10 1 A4 6 No Operating Quadrant Stages
9 5 A5
8 7 6 A9
L1
A8 A7 A6 900 A
OFF L2 A
61336 3 Voltages A
Line - Line & 3 1 L3 5
Multistep Switches without Jumper 3 Currents A V V
2 L2 B Y R V
3 Way 600 2 L1 L3
1
61649 1 Pole - 3 Way 2 L1
without OFF 1 3 4 5 3 1 90
0

L2 A A
without Jumper
3 61337 4 Voltages L3
A
6 & 4 2
N 6
V V
3 Currents 3
V
1 Pole - 4 Way A
4 Way 6 L1L2L3 N B Y R
2 10 2
61650 without OFF 1 900
L1
without Jumper 1 3 4 5 8 7 9 11 12 13 16 15 OFF 900 A A
4 2 61338 3 Voltages L2 A
61670 2 Pole - 4 Way 14
4 Line to Neutral & 3 1
L3
5
3
1 to 2 Pole V N
without OFF 3 Currents V
2 A
without Jumper L1 L2 L3 B Y R

Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40, 63, 80, 100, 125 and 200 Amps. Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps.

10 11
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Ammeter Selector Switches Motor Control Switches


Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
No Operating Quadrant Stages Motor Control Switches directly operate the motor with AC3 or AC4 duty rating.

900
R They are typically used for “Forward-Reverse”, “Star-Delta” and “Two Speed Forward-Reverse”. Motor Control Switches are also
OFF
61325 1 Pole - Y designed to operate with a contactor having built-in tripping feature in the event of power failure and overload.
A A
3 Transformer B R
B
A 3
with OFF
Y A
R Y B

900
R Motor Reversing Switches
ON
61321 1 Pole - A A
A 1 Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
1 Transformer OFF
No Operating Quadrant Stages
A
R
60
0 L1
90
0 R 61210 2 Pole 0
L1
2
OFF
1 2
UV L2 UVW
1 Pole - Y
61331 A A L2 L3
2 Transformer
3 1 A 2 M 2~ M 3~
2
61211 3 Pole L1 L2 L1 L2 L3 3
A
Y R
Spring return to "1"
0
R 45
0
L1
61384 1 Pole - 2 90 61253 3 Pole 1
0
2 L2
Y U VW
3 Transformer 1 3
A
A
A
3 Spring Return L3 3
B M 3~
without OFF L1 L2 L3
A
B Y R
L1 Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32Amps and above.
1 900
61326 1 Pole - L2
L3 A A
4 Transformer 4 2 A 4
with OFF
L4 Motor Switches/Star Delta Switches
3 A L4 L1
L3 L2
Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
900
R
61327 2 Pole - 0 No Operating Quadrant Stages
Y A1 A2
2 Transformer 1 2 A 3
with OFF R1 R2 Y 600
Y1 Y2 61200 OFF -
0
Star - Delta
90
0 L1 4
OFF
61328 3 Pole - L2
3 Transformer B R 5 L3
with OFF R
Y
L1 L2 L3
Y A1 A2
A U1 U2
B M
90
0
450 V1 3~ V2
Y
3 Pole - 0 Y W1 W2
R1 R2 Y1 Y2 B1 B2 61201 Spring Return
61329 3 Transformer R B 5 from Star 4
without OFF
to OFF
R
900
61330 4 Pole - 1 Y
4 Transformer B A1 A2 L1
4 2 A 6
without OFF N L2
3 0

R1 R2 Y1 Y2 B1 B2 N1 N2
61203 Standard Y
0
Y
60
L3

Direct ammeter L1 5
71000 OFF 900
L2
L1 L2 L3
Selector without U1
L3 A1 A2 U2
Current B R A 5 V1 M
3~ V2
Transformer R1 Y1 B1 W1 W2
Y R2 Y2 B2
(16 to 63Amps)
L1 L2 L3
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps.

Power Factor Meter and Wattmeter Switches 61239 Y 600 4 1


Star Delta with C 3 2
L1 3 Sequence 0
73078 One Current 90
0
C
OFF L2
Transformer L3
1 Locking &
ON 7 5 2 LMD Contractor e 3
One Voltage 2 PF
A1 B1 C1 e
Transformer
8 6 M3 ~
Y-
0
6 7 C
OFF 90 L1
73079 Two Current L2 PF A2 B2C2 5 6 7
Transformer ON ON L3 2
1 2 1
L1 L2 L3
OFF
2
61240 For use with Y 900
0 14 Contractors
90 W1 V1 U1
73071 Two Wattmeter OFF L1 0 4
L2
Method 1 2
L3 2 9 5 4
M
U2
3~ V2
13 17 15 1 6 3 8 W2
18
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps. Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32. 40 and 63Amps.

12 13
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Ammeter Selector Switches Motor Control Switches


Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
No Operating Quadrant Stages Motor Control Switches directly operate the motor with AC3 or AC4 duty rating.

900
R They are typically used for “Forward-Reverse”, “Star-Delta” and “Two Speed Forward-Reverse”. Motor Control Switches are also
OFF
61325 1 Pole - Y designed to operate with a contactor having built-in tripping feature in the event of power failure and overload.
A A
3 Transformer B R
B
A 3
with OFF
Y A
R Y B

900
R Motor Reversing Switches
ON
61321 1 Pole - A A
A 1 Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
1 Transformer OFF
No Operating Quadrant Stages
A
R
60
0 L1
90
0 R 61210 2 Pole 0
L1
2
OFF
1 2
UV L2 UVW
1 Pole - Y
61331 A A L2 L3
2 Transformer
3 1 A 2 M 2~ M 3~
2
61211 3 Pole L1 L2 L1 L2 L3 3
A
Y R
Spring return to "1"
0
R 45
0
L1
61384 1 Pole - 2 90 61253 3 Pole 1
0
2 L2
Y U VW
3 Transformer 1 3
A
A
A
3 Spring Return L3 3
B M 3~
without OFF L1 L2 L3
A
B Y R
L1 Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32Amps and above.
1 900
61326 1 Pole - L2
L3 A A
4 Transformer 4 2 A 4
with OFF
L4 Motor Switches/Star Delta Switches
3 A L4 L1
L3 L2
Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
900
R
61327 2 Pole - 0 No Operating Quadrant Stages
Y A1 A2
2 Transformer 1 2 A 3
with OFF R1 R2 Y 600
Y1 Y2 61200 OFF -
0
Star - Delta
90
0 L1 4
OFF
61328 3 Pole - L2
3 Transformer B R 5 L3
with OFF R
Y
L1 L2 L3
Y A1 A2
A U1 U2
B M
90
0
450 V1 3~ V2
Y
3 Pole - 0 Y W1 W2
R1 R2 Y1 Y2 B1 B2 61201 Spring Return
61329 3 Transformer R B 5 from Star 4
without OFF
to OFF
R
900
61330 4 Pole - 1 Y
4 Transformer B A1 A2 L1
4 2 A 6
without OFF N L2
3 0

R1 R2 Y1 Y2 B1 B2 N1 N2
61203 Standard Y
0
Y
60
L3

Direct ammeter L1 5
71000 OFF 900
L2
L1 L2 L3
Selector without U1
L3 A1 A2 U2
Current B R A 5 V1 M
3~ V2
Transformer R1 Y1 B1 W1 W2
Y R2 Y2 B2
(16 to 63Amps)
L1 L2 L3
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps.

Power Factor Meter and Wattmeter Switches 61239 Y 600 4 1


Star Delta with C 3 2
L1 3 Sequence 0
73078 One Current 90
0
C
OFF L2
Transformer L3
1 Locking &
ON 7 5 2 LMD Contractor e 3
One Voltage 2 PF
A1 B1 C1 e
Transformer
8 6 M3 ~
Y-
0
6 7 C
OFF 90 L1
73079 Two Current L2 PF A2 B2C2 5 6 7
Transformer ON ON L3 2
1 2 1
L1 L2 L3
OFF
2
61240 For use with Y 900
0 14 Contractors
90 W1 V1 U1
73071 Two Wattmeter OFF L1 0 4
L2
Method 1 2
L3 2 9 5 4
M
U2
3~ V2
13 17 15 1 6 3 8 W2
18
Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25 and 32Amps. Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32. 40 and 63Amps.

12 13
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Motor Switches/Multi Speed Switches Gang Switches


Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of The Gang Switches increase capacity of circuits by ganging in serial or parallel operations for different circuit
No Operating Quadrant Stages capacity. Serialing enhances power of battery supply and paralleling the power of resistor.
1 600 L1 U1 U2
M
61212 2 Speed in one 0 2 L2 V1 3~ V2
W2
Applications: In railway coaches for controlling the Alternator and Battery supply. Also in telecom panels and
L3 W1 4
Direction Single special application circuits.
Winding L1 L2 L3

600 L1 U1 U2 Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
0 M
L2 V1 3~ V2 No Operating Quadrant Stages
61213 2 Speed with 1 2
W1 W2
L3 4
Centre OFF L1 A1 A2
Single Winding L1 L2 L3
61109 2 Gang with OFF N A B
1
L1 L2 L3 17 1 Pole
1 600 18
61215 2 Speed Single U1 U2 1 Pole
0 2
M 2 GANG L1
Winding for use V1 3~ V2 5
W1 W2 A1 A2
(with Contractor) L1 L2 L3 0 60
0

1 L1
20 61117 2 Gang with OFF
N A B 2
L1 U1 U2 2 Pole 2
0 600 M
61217 2 Speed Single 1 1
L2 V1 3~ V2 L1 N B1 B2 2 Pole
W1 W2
Winding L3 6
2 2 A1 B1 C1 A2 B2 C2
Forwarding/ L1
L1 L2 L3 L2
Reversing 61111 2 Gang with OFF
L3 3
600 L1 3 Pole
1 A B
61219 2 Speed 0 2
L2 U1 U2
L1 L2 L3
3 Pole
M
2 Separate L3 V1 3~ V2 3
W1 W2 A1 A2 A3
Windings L1
L1 L2 L3
61110 3 Gang with OFF N A B C
2
600 L1 1U1 2U1 1 Pole
OFF M
61226 3 Speed L2 1V1 3~ 2V1 1 Pole
1
1W1 2W1 3 GANG L1
2 Windings L3 6
(O-A-B-A) 2 L1 A1 A2 A3
3 1U21V21W2 OFF 900 L2
L1 L2 L3
61118 3 Gang with OFF L3
3 1
A B C 3
90
0 L1 1U1 2U1 2 Pole
OFF M
61243 3 Speed L2 1V1 3~ 2V1 2 L1 L2 L3 B1 B2 B3
3 Pole
1W1 2W1
2 Windings 3 1 L3 6
(O-A-B-B) L1 A1 A2
2 1U21V21W2
L1 L2 L3 61112 3 Gang with OFF N A B
5
Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40 and 63Amps. 3 Pole
1 Pole
L1

A1 A2
Motor Switches - Start and Run Switches 61113 2 Gang, Series L1
with OFF N A B 1
Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of 1 Pole 2 GANG 2 Pole
L1 N B1 B2
No Operating Quadrant Stages
OFF 900
L1 A1 B1 C1 A2 B2 C2
Spring return from Start to "0"
L1 61115 2 Gang, Series
1 L2
3 1
61208 Split - Phase START
N U1 with OFF L3 2
M K1 2
Start 0 U2 2 Pole 2 A B 3 Pole
L1 L2 L3
L1 N
Spring return from Start L1 A1 B1 C1 A2 B2 C2
L1 61114 2 Gang, Series L2
0
61209 Split - Phase N U1 Z1 with OFF L3 3
1 2 M 3
Start Reversing U2 Z2 3 Pole A B 3 Pole
START START L1 L2 L3
L1 N
2 Gang Series Parallel
0 1 L1
60 OFF 900 L1 A1 B1 A2
61270 Split - Phase
0
2 L1 2 L2
61116 2 Gang, Series -
1 2 1 L2 N
Start Reversing M 3 Parallel with OFF 3 1 A B 2
3 L1 3 L2
Switching 2 Pole L1 N 3 Pole
2
1 L1 1 L2

Feasible ampere rating: 16, 20, 25 and 32Amps and for Sprint Return Switches and for Stay put 16Amps and above. Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40 and 63Amps.

14 15
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Motor Switches/Multi Speed Switches Gang Switches


Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of The Gang Switches increase capacity of circuits by ganging in serial or parallel operations for different circuit
No Operating Quadrant Stages capacity. Serialing enhances power of battery supply and paralleling the power of resistor.
1 600 L1 U1 U2
M
61212 2 Speed in one 0 2 L2 V1 3~ V2
W2
Applications: In railway coaches for controlling the Alternator and Battery supply. Also in telecom panels and
L3 W1 4
Direction Single special application circuits.
Winding L1 L2 L3

600 L1 U1 U2 Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of
0 M
L2 V1 3~ V2 No Operating Quadrant Stages
61213 2 Speed with 1 2
W1 W2
L3 4
Centre OFF L1 A1 A2
Single Winding L1 L2 L3
61109 2 Gang with OFF N A B
1
L1 L2 L3 17 1 Pole
1 600 18
61215 2 Speed Single U1 U2 1 Pole
0 2
M 2 GANG L1
Winding for use V1 3~ V2 5
W1 W2 A1 A2
(with Contractor) L1 L2 L3 0 60
0

1 L1
20 61117 2 Gang with OFF
N A B 2
L1 U1 U2 2 Pole 2
0 600 M
61217 2 Speed Single 1 1
L2 V1 3~ V2 L1 N B1 B2 2 Pole
W1 W2
Winding L3 6
2 2 A1 B1 C1 A2 B2 C2
Forwarding/ L1
L1 L2 L3 L2
Reversing 61111 2 Gang with OFF
L3 3
600 L1 3 Pole
1 A B
61219 2 Speed 0 2
L2 U1 U2
L1 L2 L3
3 Pole
M
2 Separate L3 V1 3~ V2 3
W1 W2 A1 A2 A3
Windings L1
L1 L2 L3
61110 3 Gang with OFF N A B C
2
600 L1 1U1 2U1 1 Pole
OFF M
61226 3 Speed L2 1V1 3~ 2V1 1 Pole
1
1W1 2W1 3 GANG L1
2 Windings L3 6
(O-A-B-A) 2 L1 A1 A2 A3
3 1U21V21W2 OFF 900 L2
L1 L2 L3
61118 3 Gang with OFF L3
3 1
A B C 3
90
0 L1 1U1 2U1 2 Pole
OFF M
61243 3 Speed L2 1V1 3~ 2V1 2 L1 L2 L3 B1 B2 B3
3 Pole
1W1 2W1
2 Windings 3 1 L3 6
(O-A-B-B) L1 A1 A2
2 1U21V21W2
L1 L2 L3 61112 3 Gang with OFF N A B
5
Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40 and 63Amps. 3 Pole
1 Pole
L1

A1 A2
Motor Switches - Start and Run Switches 61113 2 Gang, Series L1
with OFF N A B 1
Prog Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. of 1 Pole 2 GANG 2 Pole
L1 N B1 B2
No Operating Quadrant Stages
OFF 900
L1 A1 B1 C1 A2 B2 C2
Spring return from Start to "0"
L1 61115 2 Gang, Series
1 L2
3 1
61208 Split - Phase START
N U1 with OFF L3 2
M K1 2
Start 0 U2 2 Pole 2 A B 3 Pole
L1 L2 L3
L1 N
Spring return from Start L1 A1 B1 C1 A2 B2 C2
L1 61114 2 Gang, Series L2
0
61209 Split - Phase N U1 Z1 with OFF L3 3
1 2 M 3
Start Reversing U2 Z2 3 Pole A B 3 Pole
START START L1 L2 L3
L1 N
2 Gang Series Parallel
0 1 L1
60 OFF 900 L1 A1 B1 A2
61270 Split - Phase
0
2 L1 2 L2
61116 2 Gang, Series -
1 2 1 L2 N
Start Reversing M 3 Parallel with OFF 3 1 A B 2
3 L1 3 L2
Switching 2 Pole L1 N 3 Pole
2
1 L1 1 L2

Feasible ampere rating: 16, 20, 25 and 32Amps and for Sprint Return Switches and for Stay put 16Amps and above. Feasible ampere rating for S, TP and RT Series : 6, 10, 16, 20, 25, 32, 40 and 63Amps.

14 15
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Control Switches Mountings Feasibility


Control Switches are used to energise contactors for controlling motor operations. Most of the Switches are “Spring Feasibility
Mounting Description
Return” type for latching of the circuit with NO contact and facilitate tripping by the tripping device. Code 6/10A 16/20A 25/32A 40/63A 80/100/ 200/
125A 400A
Applications: Control Switches offer unique alternative to multiple “Push Button Stations”, when one Switch B03 Front Mounting, Standard Mounting plate 33333
controls instead of many Push Buttons. Control Switch with many positions are offered for a suitable combination. B13 Front Mounting with next size plate 3
33333
B00 Front Mounting 48X48 plate for 25/32A and 64x64 plate for 40/63A 33
Prog No. Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. Of B19 Single Hole Mounting 32x32 plate for 6/10A only 48x48 Plate for 16-32Amps 3
33
Operating Quadrant Stages B14 Single Hole Mounting 48x48 plate for 6/10A 3
L1
B33 Front Mounting with Round padlock for 2 Position (for Isolators) 33333
1 Pole STOP -
61300 START with Spring return
N
A2 1
B30 Front Mounting with Rectangular Padlock 2 Position (for Isolators) 33333
0
Spring Return STOP
START A1 B63 Key Lockable type (Handle/Knob) 333
4
STOP START
L1
2 B90 Centre Key Lock (Pistol grip Handle in black colour only) 33
2 Pole STOP - N B02 Rear/(Back/Base) Mounting 3
33333
61388 START with 0,1
START
1 3 2 B21 Din Rail Mounting on 35mm Rail 6-32Amps 3
33
Spring Return 2 4 B32 Rear/Base Mounting, Door Interlock + Rectangular Padlock (B30+B42) 33333
1 Pole STOP - Spring return from START to "1"
B34 Rear/Base Mounting, Door Interlock + Round Padlock (B33+B42) 33333
61301
START with 1 L1 B41 Rear Mounting with Clutch Mechanism on Door 33333
Spring Return START N (Door Open in all position without Interlock)
0,1 3 1
from Start to Run
0
START
1
B42 Rear Mounting with Interlock Mechanism on Door 33333
2 4
F47 Door Clutch, Mounting Plate at front 33333
61701 Without Jumper
B17 ABS Enclosure Max stages upto 4 upto 3 upto 5 upto 5
STOP - START Spring return from START B31 ABS Enclosure with Round Padlock (B33+B17) Max stages upto 3 upto 2 upto 2
L1
SWITCH with
61307
Spring Return to
0 N
0 3
M17 Metal Enclosure Max stages upto 4 upto 4 upto 3 3
1 2
Run for a2 Units 1 2 START 1 5
2 A17 Aluminium Enclosure Max stages upto 4 upto 3 upto 2
START 6
START START 4 2 B40 Single Hole Mounting with Padlock 48 x 48 Plate For 16-32A 33
61707 Without Jumper B43 Single Hole Mounting with Centre Key 48 x 48 Plate for 16-32A 33
Contactor Control
L1
N1
L2
B45 Single Hole Mounting with Round Ring with Knob 16A-32A 33
Spring return to "0" N2
61366 with Spring 15
1 2 7 3 2
Return to OFF
1
0
2
START 2 6 8 4
Mountings
+
Front Mountings
61271
Motor Voltage
P
N
_
4
6
L S

M
SERIES
SPLIT
B03
Control Switch 2 FIELD S 3 to 5 ØB3 Drilling plan
1 5
L S 2 Panel gap

Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40 and 63Amps. ØB2

SQF
D
L A SQ B1

Length L = No of Stages of Prog x S + W

6/10 Amps by default B13 mounting 48x48mm only

IP55 protection from front Quote B13 for next bigger size front plate
Features: Type A B1 B2 B3 D F S W Max
Standard
n 4 Hole front panel
mounting S6/S10/TP6/TP10/SL6/SL10 28 36 12 4.5 38 48 9.5 18.5 12
Knob/Handle operatable
n (48x48mm)-B13
Suitable for all switching angles and
n S16/TP16/RT16/TP20/RT20 28 36 12 4.5 58 48 12 26 21
Spring Return Switches
Front assembly in 4 different colors,
n S25/S32/RT25/RT32 35 48 12 5.5 64 64 15 27 18
Yellow/Red, Grey/Black, S40/S63/RT40/RT63 44 68 15 5.5 95 88 21 33 12
Black/Black and aluminum finish
S80/S100/S125 44 68 15 5.5 118 88 26 40 10
S200 44 68 15 5.5 99 88 32 40 10
S400 44 68 15 5.5 99 88 64 40 4

16 17
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Control Switches Mountings Feasibility


Control Switches are used to energise contactors for controlling motor operations. Most of the Switches are “Spring Feasibility
Mounting Description
Return” type for latching of the circuit with NO contact and facilitate tripping by the tripping device. Code 6/10A 16/20A 25/32A 40/63A 80/100/ 200/
125A 400A
Applications: Control Switches offer unique alternative to multiple “Push Button Stations”, when one Switch B03 Front Mounting, Standard Mounting plate 33333
controls instead of many Push Buttons. Control Switch with many positions are offered for a suitable combination. B13 Front Mounting with next size plate 3
33333
B00 Front Mounting 48X48 plate for 25/32A and 64x64 plate for 40/63A 33
Prog No. Description Script Plate Marking/ Connecting Diagram/Terminal Marking No. Of B19 Single Hole Mounting 32x32 plate for 6/10A only 48x48 Plate for 16-32Amps 3
33
Operating Quadrant Stages B14 Single Hole Mounting 48x48 plate for 6/10A 3
L1
B33 Front Mounting with Round padlock for 2 Position (for Isolators) 33333
1 Pole STOP -
61300 START with Spring return
N
A2 1
B30 Front Mounting with Rectangular Padlock 2 Position (for Isolators) 33333
0
Spring Return STOP
START A1 B63 Key Lockable type (Handle/Knob) 333
4
STOP START
L1
2 B90 Centre Key Lock (Pistol grip Handle in black colour only) 33
2 Pole STOP - N B02 Rear/(Back/Base) Mounting 3
33333
61388 START with 0,1
START
1 3 2 B21 Din Rail Mounting on 35mm Rail 6-32Amps 3
33
Spring Return 2 4 B32 Rear/Base Mounting, Door Interlock + Rectangular Padlock (B30+B42) 33333
1 Pole STOP - Spring return from START to "1"
B34 Rear/Base Mounting, Door Interlock + Round Padlock (B33+B42) 33333
61301
START with 1 L1 B41 Rear Mounting with Clutch Mechanism on Door 33333
Spring Return START N (Door Open in all position without Interlock)
0,1 3 1
from Start to Run
0
START
1
B42 Rear Mounting with Interlock Mechanism on Door 33333
2 4
F47 Door Clutch, Mounting Plate at front 33333
61701 Without Jumper
B17 ABS Enclosure Max stages upto 4 upto 3 upto 5 upto 5
STOP - START Spring return from START B31 ABS Enclosure with Round Padlock (B33+B17) Max stages upto 3 upto 2 upto 2
L1
SWITCH with
61307
Spring Return to
0 N
0 3
M17 Metal Enclosure Max stages upto 4 upto 4 upto 3 3
1 2
Run for a2 Units 1 2 START 1 5
2 A17 Aluminium Enclosure Max stages upto 4 upto 3 upto 2
START 6
START START 4 2 B40 Single Hole Mounting with Padlock 48 x 48 Plate For 16-32A 33
61707 Without Jumper B43 Single Hole Mounting with Centre Key 48 x 48 Plate for 16-32A 33
Contactor Control
L1
N1
L2
B45 Single Hole Mounting with Round Ring with Knob 16A-32A 33
Spring return to "0" N2
61366 with Spring 15
1 2 7 3 2
Return to OFF
1
0
2
START 2 6 8 4
Mountings
+
Front Mountings
61271
Motor Voltage
P
N
_
4
6
L S

M
SERIES
SPLIT
B03
Control Switch 2 FIELD S 3 to 5 ØB3 Drilling plan
1 5
L S 2 Panel gap

Feasible ampere rating for S, TP and RT Series: 16, 20, 25, 32, 40 and 63Amps. ØB2

SQF
D
L A SQ B1

Length L = No of Stages of Prog x S + W

6/10 Amps by default B13 mounting 48x48mm only

IP55 protection from front Quote B13 for next bigger size front plate
Features: Type A B1 B2 B3 D F S W Max
Standard
n 4 Hole front panel
mounting S6/S10/TP6/TP10/SL6/SL10 28 36 12 4.5 38 48 9.5 18.5 12
Knob/Handle operatable
n (48x48mm)-B13
Suitable for all switching angles and
n S16/TP16/RT16/TP20/RT20 28 36 12 4.5 58 48 12 26 21
Spring Return Switches
Front assembly in 4 different colors,
n S25/S32/RT25/RT32 35 48 12 5.5 64 64 15 27 18
Yellow/Red, Grey/Black, S40/S63/RT40/RT63 44 68 15 5.5 95 88 21 33 12
Black/Black and aluminum finish
S80/S100/S125 44 68 15 5.5 118 88 26 40 10
S200 44 68 15 5.5 99 88 32 40 10
S400 44 68 15 5.5 99 88 64 40 4

16 17
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Single Hole Mounting (22.5mm cutout) Key Lockabale


B19/B14
Locking lever
B63 Drilling plan
S 3 Max. 3 Ø5.5
3 to 5 A 48
Panel gap S Panel
gap
B2

13
D

F
48

B5
L H A 23

Length L = No of Stages x S + W Drilling plan

IP65 protection from front L


Quote B14 for next bigger size front plate (available for 6/10Amps. only)
Features: IP40 protection from front B4

n Single hole mounting with std dia Type Code A D F S H W Max Length L = No of Stages x S + W
Features:
22.5 mm S6/S10/TP6/TP10 B19 25 38 32 9.5 13.5 28.5 10 Knob/Handle
n operatable Switch
n Eliminates the need for screws/hardware With key lockable assembly prevents Type A B2 B4 B5 D F S W Max
B14 27 38 48 9.5 13.5 28.5 10
for Quick-Fit Single Hole panel fixing switching by unauthorised personnel
S16/TP16/RT16/TP20/RT20 B19 32 58 48 12 13 36 8 S16/TP16/RT16/TP20/RT20 35 13 23 43.5 58 64 12 45 21
n Easy termination Key lock/Key removable only in OFF
n
n Available upto 32Amp S25/S32/RT25/RT32 B19 32 64 48 15 13 37 6 position by default, key lockable and S25/S32/RT25/RT32 35 13 23 43.5 64 64 15 45 15
removable in any other position to be S40/S63/RT40/RT63 44 13 23 43.5 95 64 21 47 10
specified
Pad Lockable Mountings Lock assembly can also be provided on
B33 Drilling plan
n
any side
S 3 to 5
Panel gap
ØB3
ØB2 Common key for all Switches
n

ON
Features :
B17 Enclosure
D

LR/HR Model B

Ø5

.5

.5
.5

Ø5

Ø5
SQ B1
L A F

Length L = No of Stages x S + W

G
J

L
H
F-48mm with B1-36mm also available on request for 16,25,32Amps
IP55 protection from front
Type A B1 B2 B3 D F S W Max
Features:
Four
n hole round padlockable mounting S16/TP16/RT16/TP20/RT20 44 36 12 4.5 58 65 12 26 6 E D A
DrillingI plan
n Secure with max. 3 padlocks in OFF S25/S32/RT25/RT32 44 36 12 4.5 64 65 15 27 6
position prevents switching ON by
unauthorised personnel S40/S63/RT40/RT63 48 68 15 5.5 95 95 21 33 6 SM, M B
n Suitable for switches only with 900 switching S80/S100/S125 48 68 15 5.5 118 95 26 40 6 Ø4.5
angle IP55
S200 48 68 15 5.5 99 95 32 40 6
S400 48 68 15 5.5 99 95 64 40 3 Features:
Switch mounted in ABS Enclosure

SQ F
n

L
Provides protection from dust and
B30 S
3 to 5
Panel
H
F1 Drilling plan
n
hazardous material with regular
gap Ø5.5 B2 Front Plate and Knob
0
n Suitable for all switching angles
E D A
n Knob/Handle operatable Drilling plan
1 n IP65 can be given on request
D

F2

Quote B31 (B17 Enclosure and B33 Round


Padlock) only for Isolater ON/OFF Switches Type Box Type A L B D E G Stages
B1
L S6/S10/TP6/TP10 SM 28 125 100 72 80 115 4
A S16/TP16/RT16 SM 28 125 100 72 80 115 3
S16/TP16/RT16 M 28 175 125 90 105 155 4
F3

IP55 protection from front Length L = No of Stages x S + W


S25/S32/RT25/RT32 SM 35 125 100 72 80 115 2
Features: Type A B1 B2 D F1 F2 F3 H S W Max
Four
n hole rectangular padlockable S25/S32/RT25/RT32 M 35 175 125 90 105 155 4
mounting S16/TP16/RT16/TP20/RT20 35 48 12 58 76 104 12 23 12 26 6 S40/S63/RT40/RT63 M 44 175 125 90 105 155 2
n Secure with max four padlocks in OFF S25/S32/RT25/RT32 35 48 12 64 76 104 12 23 15 27 6
position S40/S63/RT40/RT63 44 68 15 95 99 128 15 25 21 33 6
n Prevents switching only Type Code A L B D E G H I J Stages
S80/S100/S125 44 68 15 118 99 128 15 25 26 40 6
n Unauthorised personnel S25/S32/RT25/RT32 LR 38 130 115 161 87 102 100 - - 5
n Suitable for switches with 90switching S200 44 68 15 99 99 128 15 25 32 40 6
S40/S63/RT40/RT63 HR 46 180 155 220 120 100 - 122 147 5
angle S400 44 68 15 99 99 128 15 25 64 40 3
Available
n in Yellow/Red only

18 19
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Single Hole Mounting (22.5mm cutout) Key Lockabale


B19/B14
Locking lever
B63 Drilling plan
S 3 Max. 3 Ø5.5
3 to 5 A 48
Panel gap S Panel
gap
B2

13
D

F
48

B5
L H A 23

Length L = No of Stages x S + W Drilling plan

IP65 protection from front L


Quote B14 for next bigger size front plate (available for 6/10Amps. only)
Features: IP40 protection from front B4

n Single hole mounting with std dia Type Code A D F S H W Max Length L = No of Stages x S + W
Features:
22.5 mm S6/S10/TP6/TP10 B19 25 38 32 9.5 13.5 28.5 10 Knob/Handle
n operatable Switch
n Eliminates the need for screws/hardware With key lockable assembly prevents Type A B2 B4 B5 D F S W Max
B14 27 38 48 9.5 13.5 28.5 10
for Quick-Fit Single Hole panel fixing switching by unauthorised personnel
S16/TP16/RT16/TP20/RT20 B19 32 58 48 12 13 36 8 S16/TP16/RT16/TP20/RT20 35 13 23 43.5 58 64 12 45 21
n Easy termination Key lock/Key removable only in OFF
n
n Available upto 32Amp S25/S32/RT25/RT32 B19 32 64 48 15 13 37 6 position by default, key lockable and S25/S32/RT25/RT32 35 13 23 43.5 64 64 15 45 15
removable in any other position to be S40/S63/RT40/RT63 44 13 23 43.5 95 64 21 47 10
specified
Pad Lockable Mountings Lock assembly can also be provided on
B33 Drilling plan
n
any side
S 3 to 5
Panel gap
ØB3
ØB2 Common key for all Switches
n

ON
Features :
B17 Enclosure
D

LR/HR Model B

Ø5

.5

.5
.5

Ø5

Ø5
SQ B1
L A F

Length L = No of Stages x S + W

G
J

L
H
F-48mm with B1-36mm also available on request for 16,25,32Amps
IP55 protection from front
Type A B1 B2 B3 D F S W Max
Features:
Four
n hole round padlockable mounting S16/TP16/RT16/TP20/RT20 44 36 12 4.5 58 65 12 26 6 E D A
DrillingI plan
n Secure with max. 3 padlocks in OFF S25/S32/RT25/RT32 44 36 12 4.5 64 65 15 27 6
position prevents switching ON by
unauthorised personnel S40/S63/RT40/RT63 48 68 15 5.5 95 95 21 33 6 SM, M B
n Suitable for switches only with 900 switching S80/S100/S125 48 68 15 5.5 118 95 26 40 6 Ø4.5
angle IP55
S200 48 68 15 5.5 99 95 32 40 6
S400 48 68 15 5.5 99 95 64 40 3 Features:
Switch mounted in ABS Enclosure

SQ F
n

L
Provides protection from dust and
B30 S
3 to 5
Panel
H
F1 Drilling plan
n
hazardous material with regular
gap Ø5.5 B2 Front Plate and Knob
0
n Suitable for all switching angles
E D A
n Knob/Handle operatable Drilling plan
1 n IP65 can be given on request
D

F2

Quote B31 (B17 Enclosure and B33 Round


Padlock) only for Isolater ON/OFF Switches Type Box Type A L B D E G Stages
B1
L S6/S10/TP6/TP10 SM 28 125 100 72 80 115 4
A S16/TP16/RT16 SM 28 125 100 72 80 115 3
S16/TP16/RT16 M 28 175 125 90 105 155 4
F3

IP55 protection from front Length L = No of Stages x S + W


S25/S32/RT25/RT32 SM 35 125 100 72 80 115 2
Features: Type A B1 B2 D F1 F2 F3 H S W Max
Four
n hole rectangular padlockable S25/S32/RT25/RT32 M 35 175 125 90 105 155 4
mounting S16/TP16/RT16/TP20/RT20 35 48 12 58 76 104 12 23 12 26 6 S40/S63/RT40/RT63 M 44 175 125 90 105 155 2
n Secure with max four padlocks in OFF S25/S32/RT25/RT32 35 48 12 64 76 104 12 23 15 27 6
position S40/S63/RT40/RT63 44 68 15 95 99 128 15 25 21 33 6
n Prevents switching only Type Code A L B D E G H I J Stages
S80/S100/S125 44 68 15 118 99 128 15 25 26 40 6
n Unauthorised personnel S25/S32/RT25/RT32 LR 38 130 115 161 87 102 100 - - 5
n Suitable for switches with 90switching S200 44 68 15 99 99 128 15 25 32 40 6
S40/S63/RT40/RT63 HR 46 180 155 220 120 100 - 122 147 5
angle S400 44 68 15 99 99 128 15 25 64 40 3
Available
n in Yellow/Red only

18 19
Cam Operated Cam Operated
Rotary Switches Rotary Switches

M17 Metal Enclosure B42 Door Interlock


D1
Drilling Plan
Front Back
3 to 5mm panel gap
A2 A3 B2

2Holes
L
0
1 2

ØD

A2
ØA3

D2

SQ F1
Rubber grommet

SQ D

SQ F
A1
R 120
D3
S
G
L1 C SQ-A1
A SQ-B1
Isolators by default with knob only

Features:
IP55 protection from front Length L = No of Stages x S + W
Type A1 A2 A3 D1 D2 D3 Max L = L1 + C
n Switches mounted in sheet metal Features:
Enclosures provides protection from S6/S10/TP6/TP10 70 60 6 85 89 98 4 Mounted
n on rear side of the panel and Quote B41 for door openable in both positions without door interlock
hazardous environment S16/TP16/RT16/TP20/RT20 70 60 6 85 89 98 4 operated from the front door
n Knob/Handle operatable Door interlockable mechanism and panel
n Type A A1 A2 A3 B1 F B G C N S W Max
n Suitable for Switches upto 32Amp S25/S32/RT25/RT32 70 60 6 85 89 98 4
door openable only in OFF position S16/TP16/RT16 35 48 4.5 15 48 64 64 3.5 25 22 12 54 8
16A Forward/OFF/Reverse Only 70 60 5 75 75 110 -- Provides safety feature
n TP20/RT20
Knob/Handle oparatable
n S25/S32/RT25/RT32 35 48 4.5 15 48 64 64 3.5 25 22 15 57 8
S40/S63/RT40/RT63 44 68 5.5 18 83 88 104 5 27 26 21 66 6
B02 Rear Mounting Back Front S80/S100/S125 44 68 5.5 18 100 88 124 5 27 26 26 72 6
Drilling plan plate Drilling plan plate S200 44 68 5.5 18 83 88 104 5 27 26 32 72 6
S 3 to 5 B3 B2 A2
Panel gap
S400 44 68 5.5 18 83 88 104 8 27 26 64 72 3

B03 Standard Mounting-Spring Return


B

(Square Latching Mechanism) 3 to 5mm Panel gap

S Ø4.5
B1 A1 Drilling plan
G
L
Features:
Ø12
n Four hole base mounted on rear side Length L = No of Stages x S + W
of the panel

ØD
n Knob/Handle operatable Type A A1 B1 B2 B3 F B G S W Max
n Can also be used for panel/door S6/S10/TP6/TP10 28 36 36 9 4.5 48 48 4.5 9.5 26 12
mounting
S16/TP16/RT16/TP20/RT20 28 36 48 12 4.5 48 64 3.5 12 30 12
S25/S32/RT25/RT32 35 48 48 12 4.5 64 64 3.5 15 31 8 SQ 48
L
S40/S63/RT40/RT63 43 68 68 15 5.5 88 88 5 21 41 6 69
S80/S100/S125 43 68 100 15 5.5 88 124 5 26 48 6
S200 43 68 83 15 5.5 88 104 5 32 48 6
SQ. 64 SQ. 64
S400 43 68 83 15 5.5 88 104 8 64 48 3

0 B90 for 25A/32A 0


IP55 protection from front B13 for 16A
1 2
B21 DIN Rail Mounting Features: B03 for 25A/32A
1 2
(with center key)
(without key)
Ø4 Drilling plan Standard
n 4 hole front panel mounting
10
S
3 to 5 ØB2 Ø4.5 pistol grip handle operatable
Panel gap Suitable for 450/600 only
n
Advanced special star/spring design on
n
latching provides guaranted spring
Available in
return operation black plate/black
56

PG handle

L A B1 For B03 without key & for B90 with center kKey

Features: Length L = No of Stages x S + W Type L (No. of Stages)


n Snap mounting base on DIN EN50022
(Omega) Rail 35mm and 1.2mm thick or Type A B1 B2 D F S W Max 1 2 3 4 5 6 7
two hole rear mounting S6/S10/TP6/TP10 28 36 9 38 48 9.5 28.5 10 S16 / TP16 / RT16 (B13) 52.5 64.5 76.5 88.5 100.5 112.5 124.5
n Provides easy termination S25 / S32 / RT25 / RT32 55.5 70.5 85.5 100.5 115.5 130.5 145.5
S16/TP16/RT16/TP20/RT20 28 36 12 58 48 12 37 12
n Can also be used for panel/door
mounting S25/S32/RT25/RT32 35 48 12 64 64 15 38 8

20 21
Cam Operated Cam Operated
Rotary Switches Rotary Switches

M17 Metal Enclosure B42 Door Interlock


D1
Drilling Plan
Front Back
3 to 5mm panel gap
A2 A3 B2

2Holes
L
0
1 2

ØD

A2
ØA3

D2

SQ F1
Rubber grommet

SQ D

SQ F
A1
R 120
D3
S
G
L1 C SQ-A1
A SQ-B1
Isolators by default with knob only

Features:
IP55 protection from front Length L = No of Stages x S + W
Type A1 A2 A3 D1 D2 D3 Max L = L1 + C
n Switches mounted in sheet metal Features:
Enclosures provides protection from S6/S10/TP6/TP10 70 60 6 85 89 98 4 Mounted
n on rear side of the panel and Quote B41 for door openable in both positions without door interlock
hazardous environment S16/TP16/RT16/TP20/RT20 70 60 6 85 89 98 4 operated from the front door
n Knob/Handle operatable Door interlockable mechanism and panel
n Type A A1 A2 A3 B1 F B G C N S W Max
n Suitable for Switches upto 32Amp S25/S32/RT25/RT32 70 60 6 85 89 98 4
door openable only in OFF position S16/TP16/RT16 35 48 4.5 15 48 64 64 3.5 25 22 12 54 8
16A Forward/OFF/Reverse Only 70 60 5 75 75 110 -- Provides safety feature
n TP20/RT20
Knob/Handle oparatable
n S25/S32/RT25/RT32 35 48 4.5 15 48 64 64 3.5 25 22 15 57 8
S40/S63/RT40/RT63 44 68 5.5 18 83 88 104 5 27 26 21 66 6
B02 Rear Mounting Back Front S80/S100/S125 44 68 5.5 18 100 88 124 5 27 26 26 72 6
Drilling plan plate Drilling plan plate S200 44 68 5.5 18 83 88 104 5 27 26 32 72 6
S 3 to 5 B3 B2 A2
Panel gap
S400 44 68 5.5 18 83 88 104 8 27 26 64 72 3

B03 Standard Mounting-Spring Return


B

(Square Latching Mechanism) 3 to 5mm Panel gap

S Ø4.5
B1 A1 Drilling plan
G
L
Features:
Ø12
n Four hole base mounted on rear side Length L = No of Stages x S + W
of the panel

ØD
n Knob/Handle operatable Type A A1 B1 B2 B3 F B G S W Max
n Can also be used for panel/door S6/S10/TP6/TP10 28 36 36 9 4.5 48 48 4.5 9.5 26 12
mounting
S16/TP16/RT16/TP20/RT20 28 36 48 12 4.5 48 64 3.5 12 30 12
S25/S32/RT25/RT32 35 48 48 12 4.5 64 64 3.5 15 31 8 SQ 48
L
S40/S63/RT40/RT63 43 68 68 15 5.5 88 88 5 21 41 6 69
S80/S100/S125 43 68 100 15 5.5 88 124 5 26 48 6
S200 43 68 83 15 5.5 88 104 5 32 48 6
SQ. 64 SQ. 64
S400 43 68 83 15 5.5 88 104 8 64 48 3

0 B90 for 25A/32A 0


IP55 protection from front B13 for 16A
1 2
B21 DIN Rail Mounting Features: B03 for 25A/32A
1 2
(with center key)
(without key)
Ø4 Drilling plan Standard
n 4 hole front panel mounting
10
S
3 to 5 ØB2 Ø4.5 pistol grip handle operatable
Panel gap Suitable for 450/600 only
n
Advanced special star/spring design on
n
latching provides guaranted spring
Available in
return operation black plate/black
56

PG handle

L A B1 For B03 without key & for B90 with center kKey

Features: Length L = No of Stages x S + W Type L (No. of Stages)


n Snap mounting base on DIN EN50022
(Omega) Rail 35mm and 1.2mm thick or Type A B1 B2 D F S W Max 1 2 3 4 5 6 7
two hole rear mounting S6/S10/TP6/TP10 28 36 9 38 48 9.5 28.5 10 S16 / TP16 / RT16 (B13) 52.5 64.5 76.5 88.5 100.5 112.5 124.5
n Provides easy termination S25 / S32 / RT25 / RT32 55.5 70.5 85.5 100.5 115.5 130.5 145.5
S16/TP16/RT16/TP20/RT20 28 36 12 58 48 12 37 12
n Can also be used for panel/door
mounting S25/S32/RT25/RT32 35 48 12 64 64 15 38 8

20 21
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Knobs and Handles Knobs / Handle Colours RED BLACK Accessories Standard Style Frame Size Bigger Style

Front Plate Current Ratings Current Ratings


TD - TEAR DROP

SQ20
FL - FLAG KNOB ---
6/10Amps
A A
B SQ32

B
C

SQ36
16/20Amps 6/10Amps
D D
SQ48

CODE - TD A B C D CODE - FL A B C D

S6/S10/TP6/TP10 27 41 25 21 S6/S10/TP6/TP10 17 23 13.75 19

SQ48
25/32Amps 16/20Amps
S16/TP16/RT16 27 41 25 21 S16/TP16/RT16 27 38 24 23
S25/S32/RT25/RT32 36 51 31 25 S25/S32/RT25/RT32 27 38 24 23 SQ64

S25/S32/RT25/RT32 50 70 42 33 S25/S32/RT25/RT32 50 68 42.5 32

SQ68
PG - Pistol Grip Handle BG - Ball Grip Handle LV - Lever Handle S40Amps & above 25/32Amps
A A
A
SQ88

B
C

Sq81
B

--- S40Amps & above

C
C

D
D
SQ104
D

Special Front Plates


CODE - PG A B C D CODE - BG A B C D CODE - LV A B C D 48 x 60 ---
48
S16/TP16/RT16/TP20/RT20 36 102 82 56 S16/TP16/RT16/TP20/RT20 36 100 67 45 S80/S100/S125 50 115 90 45
10Amps
S25/S32/RT25/RT32 36 102 82 56 S25/S32/RT25/RT32 36 100 67 45 S200/S400 50 115 90 45 16Amps

SQ 36

60
20Amps
S40/S63 36 102 82 56 S40/S63 36 100 67 45

Accessories Extended Terminals


64 x 80
64

7.5 S25/S32/SG25 2
S16 1.5 8.5 S63 R8 25/32Amps 16/20Amps
Ø 8.5

80
SQ48
Ø 3.8
8

M4
3.2
13.8

27
13.5

Protection Covers (Shrouds)


7.5

9.5
S-Series
12.5 8.5 15 16
H
Supplied as optional for S40 and S63 on request
Type øD 2 Stage 3 Stage

H
Extended Terminals - Always mounted on Switch Push On Terminals S6/S10 43±0.2 25 34.5
S80/S100/S125 S16/S25/S32 69±0.2 35 50
S200 2-64020-00-001-401-14 S6/S10/S16/TP16
15
2 Ø
8. 5
3 53 D S40/S63 95±0.2 54 75
Ø 10.5 Rectangular L
6.3

6.3
8

Type L D H No. of Stages


43

44

210 200 73 2
32

4
30.5

S63
210 200 94 3

H
D
45 0

45 0

175 110 115 2


0.8

0.8

1.5 22 22 61 S80 to S200


210 200 100 2
Always mounted on Switch Mating terminal socket Code No : 1653

22 23
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Knobs and Handles Knobs / Handle Colours RED BLACK Accessories Standard Style Frame Size Bigger Style

Front Plate Current Ratings Current Ratings


TD - TEAR DROP

SQ20
FL - FLAG KNOB ---
6/10Amps
A A
B SQ32

B
C

SQ36
16/20Amps 6/10Amps
D D
SQ48

CODE - TD A B C D CODE - FL A B C D

S6/S10/TP6/TP10 27 41 25 21 S6/S10/TP6/TP10 17 23 13.75 19

SQ48
25/32Amps 16/20Amps
S16/TP16/RT16 27 41 25 21 S16/TP16/RT16 27 38 24 23
S25/S32/RT25/RT32 36 51 31 25 S25/S32/RT25/RT32 27 38 24 23 SQ64

S25/S32/RT25/RT32 50 70 42 33 S25/S32/RT25/RT32 50 68 42.5 32

SQ68
PG - Pistol Grip Handle BG - Ball Grip Handle LV - Lever Handle S40Amps & above 25/32Amps
A A
A
SQ88

B
C

Sq81
B

--- S40Amps & above

C
C

D
D
SQ104
D

Special Front Plates


CODE - PG A B C D CODE - BG A B C D CODE - LV A B C D 48 x 60 ---
48
S16/TP16/RT16/TP20/RT20 36 102 82 56 S16/TP16/RT16/TP20/RT20 36 100 67 45 S80/S100/S125 50 115 90 45
10Amps
S25/S32/RT25/RT32 36 102 82 56 S25/S32/RT25/RT32 36 100 67 45 S200/S400 50 115 90 45 16Amps

SQ 36

60
20Amps
S40/S63 36 102 82 56 S40/S63 36 100 67 45

Accessories Extended Terminals


64 x 80
64

7.5 S25/S32/SG25 2
S16 1.5 8.5 S63 R8 25/32Amps 16/20Amps
Ø 8.5

80
SQ48
Ø 3.8
8

M4
3.2
13.8

27
13.5

Protection Covers (Shrouds)


7.5

9.5
S-Series
12.5 8.5 15 16
H
Supplied as optional for S40 and S63 on request
Type øD 2 Stage 3 Stage

H
Extended Terminals - Always mounted on Switch Push On Terminals S6/S10 43±0.2 25 34.5
S80/S100/S125 S16/S25/S32 69±0.2 35 50
S200 2-64020-00-001-401-14 S6/S10/S16/TP16
15
2 Ø
8. 5
3 53 D S40/S63 95±0.2 54 75
Ø 10.5 Rectangular L
Other special size mounting plates at Front or Rear can be supplied against requirement.
6.3

6.3
8

Type L D H No. of Stages


43

44

210 200 73 2
32

4
30.5

S63
210 200 94 3

H
D
45 0

45 0

175 110 115 2


0.8

0.8

1.5 22 22 61 S80 to S200


210 200 100 2
Always mounted on Switch Mating terminal socket Code No : 1653 In case of fixing at site use supplied hardware only.

22 23
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Customised Programme Front plate

P
Programme Number 73037
Customised Programme Formation
The Switch design and construction gives flexibility for making customised programmes
Front plate Programme Number OFF 1
1
3
3
5
5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 within a very short period. Basically an engineer trying to specify the customised
programme should concentrate on the following points.
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 (a) Number of operating positions of Switch Handle
2 4 6

Switching angle 60
0 (b) Total number of contacts required
Switch positions (c) Contact closing sequence of all the contacts required in various positions of handle.
OFF 1
2 Please note :
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 3

TUBE
4
5
1) Each position should be identified and script plate marking required in those
6
7
positions should be mentioned.
2) The standard latching angle (angle between positions)/switching angles are 600,
8
TUBE & FAN 9
10
11 900, 450 and 30. Spring Return are also possible for 450 and 900 switching angle.
12
FAN 13
14 (d) Total number of contacts can be decided based on the actual need. You may arrange
15
16 the contacts to your convenience and number them as ½,3/4, 5/6...etc. While making
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 FAN & LAMP 17
the Switch, we may rearrange the contacts to use solid Jumpers so as to avoid loose
18
19
20 wire Jumpers.
NIGHT LAMP 21
22
23
(e) Fill up the Programme sheet by marking ‘X’ at places where contacts have to Close
24
(NC).
Switching angle X
Locked positions X Contact Closed
Contact Closed without
interruption
Spring return

1 2 Mounting 3 With Without


Also specify the ampere rating, mounting style, switching angle, script plate
Switch Type S 16 B03 Stop
4
Front plate
Type Colour 7
Form X
markings, terminal marking and lockable position (If any).
Optional extras
Switching positions 5
50 Yellow
For example refer the sample customised programme sheet of a Bedroom Switch
Marking
6
Handle
Type
Tear drop
Colour
Red
Customer Date having 3 contacts controlling a tube, fan and night lamp.
1 CUSTOMER CODE No. Note: The above construction carries a five digit number starting with (7xxxx) allotted by
2 us. This number alone is sufficient for future correspondence and further ordering.
3 Ordering Code
4
Programme Code Type Ampere Mounting Knob Color
5
6
7
8 Example : 6 1 1 9 7 S 2 0 0 B 0 3 T D Y R
9 Programme Selection Type Selection
10 Programmes Prog Type Code Possible Amps Ampere Code Ampere Code
11 Code S-Series S 6 to 400Amps 6 A 100 K
12 Isolators Pg 06 Touch Proof T 6 to 20Amps 10 B 125 L
Changeovers with OFF Pg 07 Rear Access Termination R 16 to 63Amps 16 C 200 N
13
Changeovers without OFF Pg 08 DC Switches D 16 to 500Amps 20 D 250 O
14
Multistep with OFF Pg 09 Phase Selector only for P 25 to 63Amps 25 E 300 P
15 1 Pole 3 Way with OFF
Multistep without OFF Pg 10 32 F 400 Q
16 Ammeter (CT Operated) P 6 and 10Amps
Instrumentation Switches Pg 11 40 G 500 R
Voltmeter (Phase to Phase (available only with
17 Motor Control Switches Pg 13 63 I
with OFF) four hole mounting)
18 Gang Switches Pg 15 80 J
L - Series L 6 to 10 Amps
19 Control Switches Pg 16 (Spring clamp screwless)
20
Color Combination Selection
21
CODE - YR CODE - GB CODE - BB CODE - AB
22
23
24

Locked position Contact closed Contact closed without Spring return


X X
interruption

1 2 3 With Without
Mounting
Switch Type Form Position Yellow Front Plate Grey Front Plate Black Front Plate Alluminium (silver) Foil Front Plate
Red Handle Black Handle Black Handle with Black Handle
4 Size Colour 7
Front plate Optional extras Knobs and Handles Selection
CODE- TD CODE- FH CODE - BG CODE- PG CODE- LV
5
Marking
6 Type Colour Customer Date
Handle

Customer Code No.

Tear Drop Handle Flag Handle Ball Grip Handle Pistal Grip Lever Handle
Handle

24 25
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Customised Programme Front plate

P
Programme Number 73037
Customised Programme Formation
The Switch design and construction gives flexibility for making customised programmes
Front plate Programme Number OFF 1
1
3
3
5
5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 within a very short period. Basically an engineer trying to specify the customised
programme should concentrate on the following points.
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 (a) Number of operating positions of Switch Handle
2 4 6

Switching angle 60
0 (b) Total number of contacts required
Switch positions (c) Contact closing sequence of all the contacts required in various positions of handle.
OFF 1
2 Please note :
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 3

TUBE
4
5
1) Each position should be identified and script plate marking required in those
6
7
positions should be mentioned.
2) The standard latching angle (angle between positions)/switching angles are 600,
8
TUBE & FAN 9
10
11 900, 450 and 30. Spring Return are also possible for 450 and 900 switching angle.
12
FAN 13
14 (d) Total number of contacts can be decided based on the actual need. You may arrange
15
16 the contacts to your convenience and number them as ½,3/4, 5/6...etc. While making
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 FAN & LAMP 17
the Switch, we may rearrange the contacts to use solid Jumpers so as to avoid loose
18
19
20 wire Jumpers.
NIGHT LAMP 21
22
23
(e) Fill up the Programme sheet by marking ‘X’ at places where contacts have to Close
24
(NC).
Switching angle X
Locked positions X Contact Closed
Contact Closed without
interruption
Spring return

1 2 Mounting 3 With Without


Also specify the ampere rating, mounting style, switching angle, script plate
Switch Type S 16 B03 Stop
4
Front plate
Type Colour 7
Form X
markings, terminal marking and lockable position (If any).
Optional extras
Switching positions 5
50 Yellow
For example refer the sample customised programme sheet of a Bedroom Switch
Marking
6
Handle
Type
Tear drop
Colour
Red
Customer Date having 3 contacts controlling a tube, fan and night lamp.
1 CUSTOMER CODE No. Note: The above construction carries a five digit number starting with (7xxxx) allotted by
2 us. This number alone is sufficient for future correspondence and further ordering.
3 Ordering Code
4
Programme Code Type Ampere Mounting Knob Color
5
6
7
8 Example : 6 1 1 9 7 S 2 0 0 B 0 3 T D Y R
9 Programme Selection Type Selection
10 Programmes Prog Type Code Possible Amps Ampere Code Ampere Code
11 Code S-Series S 6 to 400Amps 6 A 100 K
12 Isolators Pg 06 Touch Proof T 6 to 20Amps 10 B 125 L
Changeovers with OFF Pg 07 Rear Access Termination R 16 to 63Amps 16 C 200 N
13
Changeovers without OFF Pg 08 DC Switches D 16 to 500Amps 20 D 250 O
14
Multistep with OFF Pg 09 Phase Selector only for P 25 to 63Amps 25 E 300 P
15 1 Pole 3 Way with OFF
Multistep without OFF Pg 10 32 F 400 Q
16 Ammeter (CT Operated) P 6 and 10Amps
Instrumentation Switches Pg 11 40 G 500 R
Voltmeter (Phase to Phase (available only with
17 Motor Control Switches Pg 13 63 I
with OFF) four hole mounting)
18 Gang Switches Pg 15 80 J
L - Series L 6 to 10 Amps
19 Control Switches Pg 16 (Spring clamp screwless)
20
Color Combination Selection
21
CODE - YR CODE - GB CODE - BB CODE - AB
22
23
24

Locked position Contact closed Contact closed without Spring return


X X
interruption

1 2 3 With Without
Mounting
Switch Type Form Position Yellow Front Plate Grey Front Plate Black Front Plate Alluminium (silver) Foil Front Plate
Red Handle Black Handle Black Handle with Black Handle
4 Size Colour 7
Front plate Optional extras Knobs and Handles Selection
CODE- TD CODE- FH CODE - BG CODE- PG CODE- LV
5
Marking
6 Type Colour Customer Date
Handle

Customer Code No.

Tear Drop Handle Flag Handle Ball Grip Handle Pistal Grip Lever Handle
Handle

24 25
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Breaker Control Switches Mounting Styles


Under this 3 types are widely used
a) Spring return 3 to 5mm Panel gap
NEUTRAL S
b) Lost Motion contact (LMD) Drilling plan
c) Sequence Locking (Two consecutive movement in one direction arrested) T C
Ø 4.5 Ø 12
R L
All the above can also be with external KEY and LOCK arrangement. I O
P S
E
In SPRING RETURN type the handle is always return to NEUTRAL position and does not stay in

Ø58
other TWO positions, when the handle returned to Neutral the Main/TRIP contact will be in open
condition.
In LMD, the contact block is divided into two, as main contacts and LMD contacts. LMD Contacts will
be closed with the handle is moved to CLOSE side/TRIP side and the contact closing will be retained
even though the handle is returned to the NEUTRAL by virtue of Spring Return nature. When the 82
handle is rotated on the opposite direction then only the LMD contact will open. ! Spring Return to Neutral
Position from both the L
Thus the LMD mechanism enables the Switch to have a memory feature of the previous operation, sides 78
which is considered to be a very essential for Circuit Breaker applications. SQ 48
Memory feature of the
In case of sequence lock, it acts like a mechanical interlock in the switch not permitting two
!
previous Operation(LMD) B03 B90
consecutive “CLOSE” operations. When you Turn the handle to CLOSE Position and handle will be ! Permits only one Close SQ. 64 SQ. 64
back to NEUTRAL due to Spring Return action. Again the handle movement on the CLOSE Shorter length handle also available on request
Operation(Sequential
side will be locked. When the handle is moved to TRIP position then only rotation to CLOSE Lock)
Type L (No.of Stages) X* LMD Y* Sequential Lock
position permitted.
NEUTRAL NEUTRAL
As indicated all the above feature models can also be supported with external lock and key S25/S32 1 2 3 4 5 6 7
arrangement with key lockable and removable only at NEUTRAL position and the handle shall not be C C 53 68 83 98 113 128 143 15 27.5
T T
turned when the key is in locked condition. R L R L
O I O
I
S S *LMD Dimension ‘X’ to be added
P P
E E *Sequential Lock Dimension ‘Y’ to be added

Technical Specifications General


Endurance : B90 is available only black front plate &
Description Unit S25 S32 Mechanical black PG handle type
100,000 operations at
V AC 690 690
Rated Operational Voltage Ue 300 cycles/hour
V DC 250 250
Resistance to Surge Voltage Uimp kV 6 6 Electrical
Rated Uninterrupted Current Ith A 32 40 10,000 operations at Installation Procedure for Barrel Lock (Center Key Lock)
Rated Operational Current Ie 120 cycles/hour
Operational Temperature
Pilot Duty Ac15 Ensure Mating Panel Fixing Screw
250C to 550C, frequency
220-240V AC A 8 14 upto 5 kHz Orientation with Knob
380-440V AC A 5 6
Short circuit protection 25 32
A
HRC fuse size
Rated short circuit kA 10 10
Terminal cross section
Rigid wire min mm2 1.5 2.5
max 4 6
Flexible wire min mm2 1 1.5
max 2.5 4
Terminal Screw M4 M4 Switch
Terminal Tightening Torque 1.2 Nm 1.2 Nm

No of S25/SG 25 S32/SG32
Voltage Contacts Inductive L/R Amps Inductive L/R Amps Mounting Plate
Resistive Resistive
in series Amps 10 20 40 Amps 10 20 40
msec msec msec msec msec msec
50V 1 20 20 15 6 25 25 18 8
2 - - 20 14 - - 25 18 Panel
3 - - - 20 - - - 25 c Thickness
3 To 5mm
125V 1 3 2.5 1.5 1.0 5 3 2 1.2
2 20 15 10 5 25 18 12 6
3 - 20 20 10 - 25 25 12
250V 1 1.0 0.5 0.3 0.2 1.2 0.6 0.4 0.3 Barrel Lock
2 5 2 1.0 0.5 6 2.5 1.2 0.6 Assembly
3 20 10 4 1 25 12 5 1.2

26 27
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Breaker Control Switches Mounting Styles


Under this 3 types are widely used
a) Spring return 3 to 5mm Panel gap
NEUTRAL S
b) Lost Motion contact (LMD) Drilling plan
c) Sequence Locking (Two consecutive movement in one direction arrested) T C
Ø 4.5 Ø 12
R L
All the above can also be with external KEY and LOCK arrangement. I O
P S
E
In SPRING RETURN type the handle is always return to NEUTRAL position and does not stay in

Ø58
other TWO positions, when the handle returned to Neutral the Main/TRIP contact will be in open
condition.
In LMD, the contact block is divided into two, as main contacts and LMD contacts. LMD Contacts will
be closed with the handle is moved to CLOSE side/TRIP side and the contact closing will be retained
even though the handle is returned to the NEUTRAL by virtue of Spring Return nature. When the 82
handle is rotated on the opposite direction then only the LMD contact will open. ! Spring Return to Neutral
Position from both the L
Thus the LMD mechanism enables the Switch to have a memory feature of the previous operation, sides 78
which is considered to be a very essential for Circuit Breaker applications. SQ 48
Memory feature of the
In case of sequence lock, it acts like a mechanical interlock in the switch not permitting two
!
previous Operation(LMD) B03 B90
consecutive “CLOSE” operations. When you Turn the handle to CLOSE Position and handle will be ! Permits only one Close SQ. 64 SQ. 64
back to NEUTRAL due to Spring Return action. Again the handle movement on the CLOSE Shorter length handle also available on request
Operation(Sequential
side will be locked. When the handle is moved to TRIP position then only rotation to CLOSE Lock)
Type L (No.of Stages) X* LMD Y* Sequential Lock
position permitted.
NEUTRAL NEUTRAL
As indicated all the above feature models can also be supported with external lock and key S25/S32 1 2 3 4 5 6 7
arrangement with key lockable and removable only at NEUTRAL position and the handle shall not be C C 53 68 83 98 113 128 143 15 27.5
T T
turned when the key is in locked condition. R L R L
O I O
I
S S *LMD Dimension ‘X’ to be added
P P
E E *Sequential Lock Dimension ‘Y’ to be added

Technical Specifications General


Endurance : B90 is available only black front plate &
Description Unit S25 S32 Mechanical black PG handle type
100,000 operations at
V AC 690 690
Rated Operational Voltage Ue 300 cycles/hour
V DC 250 250
Resistance to Surge Voltage Uimp kV 6 6 Electrical
Rated Uninterrupted Current Ith A 32 40 10,000 operations at Installation Procedure for Barrel Lock (Center Key Lock)
Rated Operational Current Ie 120 cycles/hour
Operational Temperature
Pilot Duty Ac15 Ensure Mating Panel Fixing Screw
250C to 550C, frequency
220-240V AC A 8 14 upto 5 kHz Orientation with Knob
380-440V AC A 5 6
Short circuit protection 25 32
A
HRC fuse size
Rated short circuit kA 10 10
Terminal cross section
Rigid wire min mm2 1.5 2.5
max 4 6
Flexible wire min mm2 1 1.5
max 2.5 4
Terminal Screw M4 M4 Switch
Terminal Tightening Torque 1.2 Nm 1.2 Nm

No of S25/SG 25 S32/SG32
Voltage Contacts Inductive L/R Amps Inductive L/R Amps Mounting Plate
Resistive Resistive
in series Amps 10 20 40 Amps 10 20 40
msec msec msec msec msec msec
50V 1 20 20 15 6 25 25 18 8
2 - - 20 14 - - 25 18 Panel
3 - - - 20 - - - 25 c Thickness
3 To 5mm
125V 1 3 2.5 1.5 1.0 5 3 2 1.2
2 20 15 10 5 25 18 12 6
3 - 20 20 10 - 25 25 12
250V 1 1.0 0.5 0.3 0.2 1.2 0.6 0.4 0.3 Barrel Lock
2 5 2 1.0 0.5 6 2.5 1.2 0.6 Assembly
3 20 10 4 1 25 12 5 1.2

26 27
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Installation Procedure-Standard Switch DC Switches (CPRI Tested & RDSO Approved)


Construction and Features
D16 - D63
D Series Switches are designed for DC Switching applications. These Switches are Constructed using snap action mechanism which
Panel Fixing provides "Quick Make Quick Break" of the contacts which is essential for DC switching. The contacts are of AgCdO, double break and
Nut butt type housed in a glass filled polyamide contact stage and are operated through cams for higher electrical endurance and smooth
operation.
Suitable for 90 and 60 degree switching programmes and applicable for bothAC and DC Switching. Suitable switching programmes for
Isolator, Changeover, Multi-step and Gang Switches etc. are offered.
*Ensure Mating Orientation with Knob

Switch DC Switches D100A-D500A


Features:
n Housing made up of SMC material for rigidity and
higher mechanical strength.
n “Wiping contacts” operations helps in dust free &
Mounting Plate self cleaning concepts
n Extended terminals for Bus bar / Aluminium cable
connections
n Capston Handle Operation for better leverage.

Applications:
n D40R – Railway coaches lighting & fan circuits
switching
n ‘All DC power circuits – Railways,
Telecommunications & Power plants
Panel n Battery charging equipments
Thickness
3 To 5mm
Technical Specifications
Front
Plate & Panel
Screw Fixing Rated Operational Current le
DC
Description Unit Switch Type
Ratings
D 16 D 25 D 32 D 40 D 63
Rated on Interrupted Current (l th) A 20 32 40 50 80
Front Plate
DC 22A L/R 2m sec
Rated Operational 110 V 250 V
Script Plate Voltage
A 16 25 32 40 63
No of Series Contacts 1 2

Raster Plate
AC AC3 Rating 3 Phase 380-440V HP 7 10 14 20 25
Ring
Ratings AC21 Rating A 16 25 32 40 63
Fuse Protection A 16 25 32 40 63
Short Circuit through fault current kA 5 10 10 20 20
Knob
Terminal [Rigid] min mm2 1.5 1.5 1.5 1.5 1.5
General Cross Section [Flex] max mm2 4 4 6 10 16
Tightening Torque Nm 0.8 1.2 1.2 2 2
Maximum Contact Stages 16 10 10 6 6

Knob Screw
Description UNIT D 100 D 200 D 300 D 400 D 500
Duty Rating - DC 22 A L/R 2m sec
Operational Voltage V DC 250 250 250 250 250
Voltage for AC Rating V AC 460 460 460 460 460
Operational Current A 100 200 300 400 500
Thermal Current (l th) A 125 250 375 500 625
Switching Angle Deg 90 90 90 90 90
Maximum Contact Stages 9 9 9 9 9

28 29
Cam Operated Cam Operated
Rotary Switches Rotary Switches

Installation Procedure-Standard Switch DC Switches (CPRI Tested & RDSO Approved)


Construction and Features
D16 - D63
D Series Switches are designed for DC Switching applications. These Switches are Constructed using snap action mechanism which
Panel Fixing provides "Quick Make Quick Break" of the contacts which is essential for DC switching. The contacts are of AgCdO, double break and
Nut butt type housed in a glass filled polyamide contact stage and are operated through cams for higher electrical endurance and smooth
operation.
Suitable for 90 and 60 degree switching programmes and applicable for bothAC and DC Switching. Suitable switching programmes for
Isolator, Changeover, Multi-step and Gang Switches etc. are offered.
*Ensure Mating Orientation with Knob

Switch DC Switches D100A-D500A


Features:
n Housing made up of SMC material for rigidity and
higher mechanical strength.
n “Wiping contacts” operations helps in dust free &
Mounting Plate self cleaning concepts
n Extended terminals for Bus bar / Aluminium cable
connections
n Capston Handle Operation for better leverage.

Applications:
n D40R – Railway coaches lighting & fan circuits
switching
n ‘All DC power circuits – Railways,
Telecommunications & Power plants
Panel n Battery charging equipments
Thickness
3 To 5mm
Technical Specifications
Front
Plate & Panel
Screw Fixing Rated Operational Current le
DC
Description Unit Switch Type
Ratings
D 16 D 25 D 32 D 40 D 63
Rated on Interrupted Current (l th) A 20 32 40 50 80
Front Plate
DC 22A L/R 2m sec
Rated Operational 110 V 250 V
Script Plate Voltage
A 16 25 32 40 63
No of Series Contacts 1 2

Raster Plate
AC AC3 Rating 3 Phase 380-440V HP 7 10 14 20 25
Ring
Ratings AC21 Rating A 16 25 32 40 63
Fuse Protection A 16 25 32 40 63
Short Circuit through fault current kA 5 10 10 20 20
Knob
Terminal [Rigid] min mm2 1.5 1.5 1.5 1.5 1.5
General Cross Section [Flex] max mm2 4 4 6 10 16
Tightening Torque Nm 0.8 1.2 1.2 2 2
Maximum Contact Stages 16 10 10 6 6

Knob Screw
Description UNIT D 100 D 200 D 300 D 400 D 500
Duty Rating - DC 22 A L/R 2m sec
Operational Voltage V DC 250 250 250 250 250
Voltage for AC Rating V AC 460 460 460 460 460
Operational Current A 100 200 300 400 500
Thermal Current (l th) A 125 250 375 500 625
Switching Angle Deg 90 90 90 90 90
Maximum Contact Stages 9 9 9 9 9

28 29
Cam Operated Cam Operated
Rotary Switches Rotary Switches

D16 D63 D200-D500


105

Ø10.5
0.8
3 to 5 170 PCD
øB3

Ø10.5
S Panel Gap Drilling Plan

øB2

236
Ø10.5

Ø32
SQ F
øD

5.0

Ø3.1
3 S
24.5 24.5 33.5 35
L 138

L
35.5 SQ B1 Length L
Type S
3 4 5 6 7
Type B1 B2 B3 D F S D200-D500 22 117 139 161 183 205
D 16 48 12 5.5 50 64 12
D 25 / D 32 48 12 5.5 50 64 15
D 40 / D 63 68 15 5.5 70 88 21 D100 with Door Interlock
120
Stages 1 2 3 4 5 6 7 8 9 10 11 12 170 PCD
0.8
D 16 62 74 86 98 110 122 134 146 158 170 182 194 3.1
Length D 25/32 65 80 95 110 125 140 155 170 185 200 215 230
L in mm
D 40/63 69 90 111 132 153 174 195 216 237 258 279 300

PCD 44
Ø34.5

236
M5
D40 R M6
R200
S2 S S1

24.5 24.5
90

PO
SI
105

L 80
59

90
Ø19

41.5
26 Length L
L Type S S1 S2
133 1 2 3 4 5 6 7 8
D100 32 35 15 210 242 274 306 338 370 402 434
Length L
Type S S1 S2
1 2 3 4 5 6 7 8
D40 10 30.5 15 55.5 65.5 75.5 85.5 95.5 105.5 115.5 125.5 D200-D500 with Door Interlock
120
L = No. of Stages x S + (S+S)

Ø10.5
170 PCD
0.8

Rectangle Slot 33X20


D100 105 Ø4.3 (2Nos.)
Ø10.5

170 PCD

Ø10.5
0.8

Ø10.5

PCD 44
Ø34.5

236
Ø10.5
236

R200 3
Ø32

Ø3.1
S2 S S1 24.5 S 24.5
3
5.0 L 80
Ø3.1

24.5
33.5 35
L 138

Length L Length L
Type S S1 S2 Type S
1 2 3 4 5 6 7 3 4 5 6 7
D100 32 32 15 112 144 176 208 240 272 304 D200-D500 22 197 219 241 263 285

30 31
Cam Operated Cam Operated
Rotary Switches Rotary Switches

D16 D63 D200-D500


105

Ø10.5
0.8
3 to 5 170 PCD
øB3

Ø10.5
S Panel Gap Drilling Plan

øB2

236
Ø10.5

Ø32
SQ F
øD

5.0

Ø3.1
3 S
24.5 24.5 33.5 35
L 138

L
35.5 SQ B1 Length L
Type S
3 4 5 6 7
Type B1 B2 B3 D F S D200-D500 22 117 139 161 183 205
D 16 48 12 5.5 50 64 12
D 25 / D 32 48 12 5.5 50 64 15
D 40 / D 63 68 15 5.5 70 88 21 D100 with Door Interlock
120
Stages 1 2 3 4 5 6 7 8 9 10 11 12 170 PCD
0.8
D 16 62 74 86 98 110 122 134 146 158 170 182 194 3.1
Length D 25/32 65 80 95 110 125 140 155 170 185 200 215 230
L in mm
D 40/63 69 90 111 132 153 174 195 216 237 258 279 300

PCD 44
Ø34.5

236
M5
D40 R M6
R200
S2 S S1

24.5 24.5
90

PO
SI
105

L 80
59

90
Ø19

41.5
26 Length L
L Type S S1 S2
133 1 2 3 4 5 6 7 8
D100 32 35 15 210 242 274 306 338 370 402 434
Length L
Type S S1 S2
1 2 3 4 5 6 7 8
D40 10 30.5 15 55.5 65.5 75.5 85.5 95.5 105.5 115.5 125.5 D200-D500 with Door Interlock
120
L = No. of Stages x S + (S+S)

Ø10.5
170 PCD
0.8

Rectangle Slot 33X20


D100 105 Ø4.3 (2Nos.)
Ø10.5

170 PCD

Ø10.5
0.8

Ø10.5

PCD 44
Ø34.5

236
Ø10.5
236

R200 3
Ø32

Ø3.1
S2 S S1 24.5 S 24.5
3
5.0 L 80
Ø3.1

24.5
33.5 35
L 138

Length L Length L
Type S S1 S2 Type S
1 2 3 4 5 6 7 3 4 5 6 7
D100 32 32 15 112 144 176 208 240 272 304 D200-D500 22 197 219 241 263 285

30 31
o
h tn Intertek

i t c
Salzer Electronics Limited
Samichettipalayam Sw he Bes
Coimbatore - 641 047, INDIA.

Tel: +91 422 4233600/2692531.


Fax: + 91422 2692170.
t o t Cam Operated
Email: salzer@salzergroup.com, sales@salzergroup.com.
Website: www.salzergroup.com Rotary Switches

You might also like