1.

Main engines system - prepare fresh water cooling system rozdzielenie -

Main engines fresh water inlet valves from auxiliary fresh water pump
position should be set to OPEN
Main engines fresh water outlet valves to auxiliary fresh water pump position
should be set to OPEN

Main engines fresh water inlet valves position should be set to OPEN
Main engines fresh water pumps inlet valves position should be set to OPEN

2. Zrobi�em troch� kaszane w Start Main engines. Nie wy��cza�o si� pompy
pomocniczej wody s�odkiej i �le sformu�owa�em czynno�ci wy��czania pompy
pomocniczej wody morskiej i podgrzewacza wody s�odkiej. Nie potrzeba r�wnie�
otwiera� by-pasu podgrzewacza. Powinno by� :

4.b Start Main engines


RPM potentiometer position should be set to IDLE value
LOAD ADJUSTMENT potentiometer position should be set to �0� position
Revolution/pitch lever position should be set to �O�
Main engine no 1 START Button position should be set to ON
Main engine no 2 START Button position should be set to ON
Auxiliary sea water pump STOP switch position should be set to ON
Auxiliary sea water pump inlet valve position should be set to CLOSE
Auxiliary sea water pump outlet valve position should be set to CLOSE
Auxiliary sea water pump outlet valves before main engines position should be set
to CLOSE
Fresh water preheater position STOP switch should be set to ON
Auxiliary fresh water pump STOP switch position should be set to ON
Auxiliary fresh water pump inlet valve position should be set to CLOSE
Auxiliary fresh water pump outlet valve position should be set to CLOSE
Fresh water preheater inlet valve position should be set to CLOSE
Fresh water preheater outlet valve position should be set to CLOSE
Main engines fresh water inlet valves from auxiliary fresh water pump position
should be set to CLOSE
Main engines fresh water outlet valves to auxiliary fresh water pump position
should be set to CLOSE

3. Trzeba chyba doda� "located on Console" bo chyba nie za bardzo wiadomo o co


chodzi
6.a Main engine no 1 local start
LOCAL switch position located on Console should be set to ON