Professional Documents
Culture Documents
r1916v f7p704 Ecu Pinout PDF
r1916v f7p704 Ecu Pinout PDF
Wire side
Oscilloscope setting
ECM
Component/circuit description Signal Condition Typical value (Suggested settings - Wave form
pin
Voltage/time per division)
Connected pin - no test
Air conditioning 30 data available or random
digital signal
Connected pin - no test
Air conditioning 34 data available or random
digital signal
Connected pin - no test
Air conditioning - except F7R 700 22 data available or random
digital signal
11
Crankshaft position (CKP) sensor Engine cranking 0,1-0,8 V ac
(28)
11
Crankshaft position (CKP) sensor Engine idling 2,5 V ac 5 V/1 ms
(28)
11
Crankshaft position (CKP) sensor 3000 rpm 7 V ac
(28)
28
Crankshaft position (CKP) sensor Engine cranking 0,1-0,8 V ac
(11)
Reversed
28
Crankshaft position (CKP) sensor Engine idling 2,5 V ac 5 V/1 ms
(11)
28
Crankshaft position (CKP) sensor 3000 rpm 7 V ac
(11)
Earth 1 Ignition ON 0V
Earth 2 Ignition ON 0V
Manufacturer: Renault Model: R19 (X53) 1,8 16V © Autodata Limited 2007
Engine code: F7P 704 Output: 99 (135) 6500 17/03/2005
Tuned for: R-Cat Year: 1989-96 V6.410-
Engine control relay 19 Ignition ON 11-14 V
Heated oxygen sensor (HO2S) 35 Engine idling 0-1 V fluctuating 0,2 V/1 sec.
Ignition ON - air
Intake air temperature (IAT) sensor 14 3V
temp. 10°C
Manufacturer: Renault Model: R19 (X53) 1,8 16V © Autodata Limited 2007
Engine code: F7P 704 Output: 99 (135) 6500 17/03/2005
Tuned for: R-Cat Year: 1989-96 V6.410-
Intake air temperature (IAT) sensor 32 Ignition ON 0V
Ignition ON - vehicle
Vehicle speed sensor (VSS) 3 0 or 5 V switching
pushed
3. Analogue, AC, frequency modulated 20. Digital, DC, pulse width modulated or 21. Analogue, DC
digital, DC, frequency modulated
Manufacturer: Renault Model: R19 (X53) 1,8 16V © Autodata Limited 2007
Engine code: F7P 704 Output: 99 (135) 6500 17/03/2005
Tuned for: R-Cat Year: 1989-96 V6.410-
25. Digital, DC, pulse width modulated or 32. Digital, DC, frequency modulated 36. Digital, DC, pulse width modulated
digital, DC, frequency modulated
38. Analogue, AC
input/output signal
input signal
output signal
ECM switched earth
Manufacturer: Renault Model: R19 (X53) 1,8 16V © Autodata Limited 2007
Engine code: F7P 704 Output: 99 (135) 6500 17/03/2005
Tuned for: R-Cat Year: 1989-96 V6.410-