Concealed cam-action
door closer system
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
FLAWLESS BEAUTY
—
To ensure that prestigious characterises all DORMA
doors retain all their inherent slide channel door closers.
attraction, they can now be The cam is literally at the
fitted with a concealed cam- heart of DORMA slide
action door closer system channel door closers – it
– the DORMA ITS 96. This guarantees secure closing
is the first system of its kind, while at the same time
one which can be integrated offering a rapidly decreasing
in the door leaf and frame opening force so that even
with the utmost elegance. children, the elderly and Nm Third Party Testing Torque Curve
Where the emphasis is disabled people encounter 50
2 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
CONTENTS
—
DORMA ITS 96 Features and functions 4
Application and installation 6
Accessories 18
DORMA 3
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
— Arm
Closing force variable by means
Slide channel 2 2
515 (512)
440
20 400
20
12
3
10
76 (67)
(42)
51
334 (320)
96 (93)
9 9
R8
(32)
20
40
4 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
Adjustment of settings
The functions of the DORMA
ITS 96 can be individually
adapted to the local condi
tions of each application.
The closing strength can be 32 approx.
easily varied in accordance 120° approx.
80°
with the door width via the 4 2 3
adjustment screw accessible
from the top. The closing
speed and the latch action 1
can likewise be modified at 2 Fully controlled closing with
any time using adjustment adjustable speed
screws at the top, even after 3 Adjustable latch action
the door has been hung. 4 Cushioned limit stay
DORMA 5
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
UK Standard
X=10 X=13.5
ITS 96 2-4
ITS 96 3-6
with 1.5 mm
extended spindle
Specials
X=8.5 X=12
ITS 96 2-4
ITS 96 3-6
*G96N arm cannot be
used with ITS96 reduced
spindle unit
X=12.5 X=16
ITS 96 2-4
ITS 96 3-6
with 4 mm
extended spindle
X=16.5 X=20
ITS 96 2-4
ITS 96 3-6
with 8 mm
extended spindle
6 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
12.5
Please check
10
dimensions carefully
16
dimensions carefully
12
DORMA 7
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
approx.
120° approx. 80°
Cushioned limit stay
The DORMA G 96 N20 slide The DORMA G 96 N20 slide F Approval certification Specification text
channel pack includes the channel is adjustable to K8/
arm, slide channel, slide K12. The DORMA ITS 96 is DORMA ITS 96 ... door closer
block, cushioned limit stay approved by the State (see pages 4 and 5) with slide
and fixing screws, and can Material Testing Authority, channel G 96 N20
be combined with both door Dortmund, in accordance
with EN 1154 A. Version
closer sizes in the DORMA
Additionally, the model size Y LH (ISO 6) K8/K12
ITS 96 range.
EN 2 – 4 and EN 3 – 6 Y RH (ISO 5) K8/K12
has CERTIFIRE approval
(CF.140) for use on timber
FD30 and FD60 doors (code Make DORMA ITS 96 N20
ITT), when installed with
the approved intumescent ITS96/2-4
gasket set for FD30 or FD60 ITS96/3-6
supplied by DORMA UK.
The length, width and height
of mortice for the body must
be increased by 2 mm to
accommodate the gasket on
30 and 60 minute doors. The
channel must be increased
by 2mm for 30 minute doors
and 4mm for 60 minute
doors. The ITS 96 has 4
hour CERTIFIRE approval for
metal doors.
G 96 N Punched arm 31
440
20
200
200
20
HOLD-OPEN UNIT
—
approx.
120°
Hold-open range
8 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
20 145 440
min. 14
10
(46)
10
55
96 (99) 300 (286)
40
(32)
70 (73) 500
min. 50
=
(min. 40)
=
DORMA ITS 96 door closer with DORMA G 96 N20 slide channel in a timber door
Example: Anticlockwise-closing (ISO 6) door; mirror image applies to clockwise-closing (ISO 5) doors.
1451) 440
max. 16
DORMA ITS 96 door closer with DORMA G 96 N20 slide channel in an aluminium framed door
Example: Anticlockwise-closing (ISO 6) door; mirror image applies to clockwise-closing (ISO 5) doors.
1)
Add 25 mm for aluminium profile frames with corner-angle reinforcement.
DORMA 9
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
30
211
approx.
120° approx. 80°
211
20
Hold-open range
= Door stop
The DORMA G 96 EMF slide In the event of an alarm or The DORMA G 96 EMF slide Specification text
channel assembly enables a fault in the power supply, channel assembly comprises
the door to be held open the hold-open is released the arm, slide channel, slide DORMA ITS 96 ... door
securely at a pre-selected and the door is closed by block, electro-mechanical closer (see pages 4 and 5)
position without fall-back. the door closer. The release hold-open unit and fixing with G 96 EMF K8/K12 slide
The hold-open point can be is triggered by a signal from screws, and can be combined channel assembly, with
adjusted within an opening external smoke detectors with both door closer sizes in integrated 24 V DC electro-
angle of approx. 80° and (e.g. DORMA RMZ). the DORMA ITS 96 range. mechanical hold-open, tested
120°. The release force for the In the case of particulary to EN 1155. Hold-open point
hold-open mechanism can be large and heavy doors (over (80° – 120°) and release
Note: adjusted without tools and is 1250 mm), we recommended force adjustable.
The hold-open point also rated to ensure that the door that DORMA EM hold-open Approved by the Institute for
constitutes the max. door can also be easily released magnets be employed instead Building Technology, Berlin,
opening angle (position door manually. of the electro-mechanical for general use in hold-open
stop accordingly). hold-open unit. systems. Acceptance
inspection of the system is
mandatory in Germany.
10 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
Power supply 24 V DC
90 527
20 211 211
min. 16
30
14
98 (89)
55 (46)
10
40
(32) 96 (99) 300x40 (286x32)
70 (73) 500
min.50
(min.40)
=
DORMA ITS 96 door closer with DORMA G 96 EMF slide channel assembly in a timber door
Example: Anticlockwise-closing (ISO 6) door; mirror image applies to clockwise-closing (ISO 5) doors.
Power supply 24 V DC
901) 527
31
20 211 211
max. 16
13.5
30
97.5 (88.5)
DORMA ITS 96 door closer with DORMA G 96 EMF slide channel assembly in an aluminium framed door
Example: Anticlockwise-closing (ISO 6) door; mirror image applies to clockwise-closing (ISO 5) doors.
1) Add 25 mm for aluminium profile frames with corner-angle reinforcement.
DORMA 11
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
Version/Function Door width (mm) Door leaf thickness min. (mm) Closer size ITS 96
GSR
Door co-ordinator 1400 – 2200 40 2–4
1400 – 2800 50 3–6
Connecting tube
Specification text
Example application
ITS 96 ITS 96
G 96 GSR
12 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
Version/Function Door width (mm) Door leaf thickness min. (mm) Closer size ITS 96
GSR-EMF
Door co-ordinator and 1400 – 2200 40 2–4
hold-open in both leaves 1400 – 2800 50 3–6
Connecting tube
Specification text
DORMA ITS 96 ... door Approved by the Institute of
closer (see pages 4 – 5) with Building Technology, Berlin,
G 96 GSR-EMF K8/K12 slide for general use in hold-open
channel, featuring integrated systems. Acceptance
approx. 120° approx. 120° mechanical door co-ordinator inspection of the system is
approx. 80° approx. 80°
using a push rod clamping mandatory in Germany.
Hold-open range Hold-open range system with overload release
which operates independently Make
of the closer hydraulics, with DORMA ITS 96 GSR-EMF
integrated electro-mechanical
Active leaf Inactive leaf hold-open, ITS96GSR-EMF/2-4
24 V DC. Hold-open point ITS96GSR-EMF/3-6
= Door stop (80° – 120°) and release
force adjustable.
Tested to EN 1158 and
EN 1155.
DORMA 13
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
ITS 96 with
40 4 mm
(32) extended
spindle Active leaf
min. 700 mm
min. 50
(min. 40)
70 (73) 500
175 375
Connecting tube,
14 mm dia.
16
max. 10
31
A–A
14 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
116 527 90
211 211 20
12.5
30
8.5
55 (46)
A
Inactive leaf
min. 700 mm
1450 – 2800
(1450 – 2200)
500 70 (73)
=
=
375 175
412 45
211 161
286x32 54
28
380
260 130
F When installed in fire and smoke check doors, ensure that the DORMA MK 397 carry bar is also fitted.
DORMA 15
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
Power supply 24 V DC
(for EMF only)
31
901) 512
12
96 (87)
Active leaf
1751) 375
Combination with
electric keep/strike/locking element
Connecting frame
(see page 23)
31
Active leaf*
min. 1200 mm
16 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
527 901)
211 211 1101)
Inactive leaf
min. 700 mm
If the inactive leaves are particularly narrow (less than
700 mm), please discuss the installation possibilities
with DORMA and/or the relevant profile manufacturer.
1400 – 2800
(1400 – 2200)
375 1751)
1)
Profile frames with corner angle
reinforcement
512 115
Electric keep/strike (e.g. DORMA Series 442)
211 135
Inactive leaf*
min. 700 mm 121 (124)
200
F When installed in fire and smoke check doors, ensure that the DORMA MK 397 carry bar is also fitted.
DORMA 17
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
ACCESSORIES
—
136 458
52000405
9
55
39 5
10
25
21
141 48 352 48
X
86 48 374 48
X
BZ-I BZ-II
48 48
X =15–23
X =23–40
13
ø5
21
ø5
52004705 52004805
18 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
151
31
15
Connecting frame for G 96 GSR door co-ordinator for use on doors with electric keep/strike or overhead electromechanical
locking element (see page 18)
*Door width min. 1900 mm
DORMA 19
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
ACCESSORIES
—
If the DORMA G 96 GSR
door co-ordinators are
90 527
required to operate independ
ently of the ITS 96 door
closers, e.g. in combination
8.5
with the ED 200 automatic
swing door operator, the
connection between the door
38
3
co-ordinator and the door leaf
is provided by means of GSR 141 68
pivot blocks.
14
Make
175 375
DORMA ITS GSR pivot block
133
106
30
76.5
38
30
141 68
450
115 120
123.5 103
9.5
=
14
=
175 375
20 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
G 96 N G 96 N20 G 96 EMF
Intumescent Pack to suit Intumescent Pack to suit Intumescent Pack to suit
EN2-4 unit with standard EN2-4 unit with G 96 N20 EN2-4 EMF unit with
arm and channel arm and channel standard arm and channel
(30 min) (30 min) (30 min)
40FD3024 40FD3024N20 40FD3024EMF
Intumescent Pack to suit Intumescent Pack to suit Intumescent Pack to suit
EN3-6 unit with standard EN3-6 unit with G 96 N20 EN3-6 EMF unit with
arm and channel arm and channel standard arm and channel
(30 min) (30 min) (30 min)
40FD3036 40FD3036N20 40FD3036EMF
Intumescent Pack to suit Intumescent Pack to suit Intumescent Pack to suit
EN2-4 unit with standard EN2-4 unit with G 96 N20 EN2-4 EMF unit with
arm and channel arm and channel standard arm and channel
(60 min) (60 min) (60 min)
40FD6024 40FD6024N20 40FD6024EMF
Intumescent Pack to suit Intumescent Pack to suit Intumescent Pack to suit
EN3-6 unit with standard EN3-6 unit with G 96 N20 EN3-6 EMF unit with
arm and channel arm and channel standard arm and channel
(60 min) (60 min) (60 min)
40FD6036 40FD6036N20 40FD6036EMF
1 General
1.1 In respect of doors etc. taken in order to ensure that Smoke detectors should be systems can be released by
which are held open by wiring/ducting, stored goods used for hold-open systems pressing lightly on the door
hold-open systems, the area or structural components for doors etc. in emergency leaf. If hold-open magnets or
needed for closure must (e.g. false ceilings or other exits and escape routes. free-swing door closers are
be kept permanently free components) do not fall used, the release function
of obstructions. This area down into the area to be 1.3 All hold-open devices is triggered by pressing a
should be clearly indicated kept clear. should allow manual release switch. The switch must be
by means of lettering, floor without their operational located in the immediate
markings or similar. 1.2 As far as possible, readiness being adversely proximity of the door and
If necessary, structural smoke detectors should be affected. Door closers with must not be covered when
measures may need to be used for hold-open systems. electro-magnetic hold-open the door is held open.
2 Commissioning
3 Routine Inspection
3.1 The operator should 3.2 In addition, it is the once a year, unless a shorter 3.3 The scope, result
keep the hold-open system responsibility of the operator time period is stipulated and time of the routine
in a permanently fit state to ensure that all devices in the national regulations. inspections should be
for use and must inspect are checked and maintained/ This inspection and servicing recorded, and these records
it at least once a month serviced to ensure their activity should only be should be retained by the
to ensure its functional combined functional integrity, carried out by a specialist or operator.
integrity. this to be performed at least suitably qualified person.
DORMA 21
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
EN 2 – 4 EN 2 – 4 EN 2 – 4 EN 2 – 4
8 52400150 8 52430150 8 52410150 8 52420150
EN 3 – 6 EN 3 – 6 EN 3 – 6 EN 3 – 6
8 52250150 8 52290150 8 52260150 8 52270150
G 96 N20
L ( 52003701 8 ( 8 ( 8 ( 8 ( 8
K8/K12
R ( 52003801 ( 8 ( 8 ( 8 ( 8
G 96 N
K8/K12 R ( 52000501 8 ( 8 ( 8 ( 8 ( 8
G 96 EMF
L ( 52001501 10 ( 8 ( 8 ( 8 ( 8
K8/K12
R ( 52001601 ( 8 ( 8 ( 8 ( 8
G 96 GSR
( 52001801 12 ( 2x 8 ( 2x 8 ( 2x 8 ( 2x 8
K8/K12
2601) ( 52004001 ( 2x 8 ( 2x 8 ( 2x 8 ( 2x 8
G 96 GSR-EMF
( 52001701 16 ( 2x 8 ( 2x 8 ( 2x 8 ( 2x 8
K8/K12
2601) ( 52004201 ( 2x 8 ( 2x 8 ( 2x 8 ( 2x 8
1)
GSR door co-ordinator for inactive leaf of 540–700 mm
(inactive leaf slide channel shortened, arm 260 mm)
2)
Pivot bearing with 4 mm and 8 mm extended spindle available
on request
3)
MK 397 Colour xx
galvanised 00
special colour 30
22 DORMA
ITS 96 CONCEALED CAM-ACTION DOOR CLOSER SYSTEM
RF hold-open unit RF hold-open unit Fixing BZ I Fixing BZ II Fixings for mounting Connecting frame Pivot bearing Carry bar
for G 96 N20 for G 96 GSR, for narrow-stile/ for narrow-stile/ the G 96 N20 for G 96 GSR MK 397
inactive leaf alu-framed doors alu-framed doors aluminium doors
K8/K12 K8/K12
52005600 52003500 52004705 52004805 52000405 52004400 520034002) 470029xx3)
8 12 15 15 18 19 20 –
Z Z Z Z Z
Z Z Z Z Z
Z Z
Z Z
Z Z
Z Z Z Z Z Z
Z Z Z Z Z Z
Z Z Z Z
Z Z Z Z
DORMA 23
DORMA UK Limited
Wilbury Way
Hitchin
Hertfordshire
SG4 0AB