Research Article
Simulation and Optimization of Air-Cooled PEMFC Stack for
Lightweight Hybrid Vehicle Application
Copyright © 2015 J. Liang and Z. Wu. This is an open access article distributed under the Creative Commons Attribution License,
which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
A model of 2 kW air-cooled proton exchange membrane fuel cell (PEMFC) stack has been built based upon the application of
lightweight hybrid vehicle after analyzing the characteristics of heat transfer of the air-cooled stack. Different dissipating models
of the air-cooled stack have been simulated and an optimal simulation model for air-cooled stack called convection heat transfer
(CHT) model has been figured out by applying the computational fluid dynamics (CFD) software, based on which, the structure
of the air-cooled stack has been optimized by adding irregular cooling fins at the end of the stack. According to the simulation
result, the temperature of the stack has been equally distributed, reducing the cooling density and saving energy. Finally, the
2 kW hydrogen-air air-cooled PEMFC stack is manufactured and tested by comparing the simulation data which is to find out
its operating regulations in order to further optimize its structure.
These heat energies mainly embrace chemistry respon- Single cell and cooling border to conduct convection heat
dent heat, ohm heat, phase change heat, and entropy increas- exchange can be expressed as
ing heat, of which the first one is irreversible, whereas the last
conv
one is reversible; in addition, some sensible heat forms the 𝑄nat,for = − 𝜆 ⋅ ∇𝑇, (7)
temperature difference between the inlet gas and the outlet
one. Therefore, the necessary dissipating heat of every single where forcing convection can be expressed as
cell is composed of reversible heat, irreversible heat, and conv
𝑄for = 𝜁ℎfor (𝑇cell − 𝑇in ) , (8)
sensible heat, which can be expressed as below [4, 6]:
𝑄ℎ = 𝑄rev + 𝑄irrev + 𝑄sens , (1) where 𝜁 is blades’ modulus and ℎfor is the forcing convec-
tion modulus, W/(m2 ⋅K), where natural convection can be
where 𝑄rev is reversible heat, J; 𝑄irrev is irreversible heat, J; and expressed as
𝑄sens is sensible heat, J: conv
𝑄nat = ℎnat (𝑇cell − 𝑇amb ) , (9)
𝐼
𝑄rev = (−𝑇cell Δ𝑆𝑇 ) cell ,
𝑛𝐹 where ℎnat is the natural convection modulus, W/(m2 ⋅K) and
𝑇amb is the surrounding atmosphere temperature, K.
Δ𝐺𝑇 (2)
𝑄irrev = (− − 𝑉cell ) 𝐼cell , Radiation heat can be expressed as
𝑛𝐹
Δ𝐺𝑇 = Δ𝐻𝑇 − 𝑇cell Δ𝑆𝑇 , 𝑄rad = 𝛿 ⋅ 𝜎𝑏 ⋅ 𝐴 rad ⋅ (𝑇cell 4 − 𝑇amb 4 ) , (10)
where 𝐼cell is stack current, A; 𝑇cell is stack average temper- where 𝛿 is stack blackness; 𝜎𝑏 is Stefan-Boltzmann constant;
ature, K; 𝑉cell is stack voltage, V; 𝐺𝑇 is Gibbs free energy, and 𝐴 rad is the stack radiation area, m2 .
kJ/mol; 𝐹 is Faraday constant, C/mol; and Δ𝑆𝑇 and Δ𝐻𝑇 are The convection exchange heat modulus ℎfor is obtained
total entropy and total enthalpy of the supplying gas: according to the equation
0.14
𝑄sens = 𝑄sens in − 𝑄sens out , (3) 𝐷ℎfor 𝐷 1/3 𝜇
Nu = = 1.86 (RePr ) ( ) , (11)
in out
𝜆 𝐿 𝜇𝑝
where Qsens and Qsens are the inlet and outlet sensible heat
of total reactant gas, J: where 𝜆 is the air heat conduction modulus, W/m2 ⋅K; 𝐷 is
Δ𝐻𝑇 the hydraulic diameter, m; Pr is the Prandtl number; 𝐿 is the
𝑄ℎ = (− − 𝑉cell ) 𝐼cell + 𝑄sens . (4) length of the water hose, m; and Re is the Reynolds number:
𝑛𝐹
Accordingly, the heat produced in a single cell is the Nu = 0.664Pr1/3 Re1/2 ,
total power of the electrochemistry; respondent subtracts the (12)
UL
power that the cell gives out and adds the total sensible heat Re = .
of the inlet and outlet gas, whose expression is shown in (4). 𝜇
The heat generation of stack is the total heat generated from
every single cell: 2.3. The Simulation Model of Different Heat Dissipation for
Air-Cooled Stack. When CFD software is applied to simulate
𝑄stack = 𝑛𝑄ℎ . (5) PEMFC, the surface heat dissipating models can be catego-
rized to be five [8]: specified heat flux, specified temperature
2.2. The Heat Dissipation of Stack. The air-cooled stack (ST), CHT, external radiation, combined external radiation,
requires to discontinuously dissipate heat so as to maintain and external convective heat transfer. The latter three heat
its steady operation. The main approaches of heat dissipation dissipating models have been analyzed from (8) to (10); the
include forcing convection heat dissipation whose heat is first model is usually applied in the insulation layer, whose
dissipated by the air of the cooling plate and natural convec- heat flow is set to be zero that can be skipped. The ST
tion and radiation on the stack surface; yet, radiation merely dissipating model can be divided into fluid surface and solid
dissipates a little heat due to the low operation temperature of surface, which can be expressed as follows.
the stack; in addition, the inlet and outlet of the respondent For fluid surface, consider
gas also dissipate some heat; heat conduction loses less heat,
which can be neglected; therefore, the stack heat dissipation 𝑄 = ℎ𝑓 (𝑇𝑤 − 𝑇𝑓 ) + 𝑄rad , (13)
can be expressed as [7]
where ℎ𝑓 is fluid-side local heat transfer coefficient and
𝑖
𝑄stack = ∑ (𝑚̇ out 𝐶𝑝𝑖 𝑇out − 𝑚̇ in
𝑖
𝐶𝑝𝑖 𝑇in ) + 𝑄conv + 𝑄rad , 𝑇𝑤 and 𝑇𝑓 are wall surface temperature and local fluid
(6)
𝑖 temperature, respectively, K.
For solid surface, consider
𝑖 𝑖
where 𝑖 is some kind of reactant gas; 𝑚̇ out and 𝑚̇ in are the
quality flow of the outlet and inlet reactant, kg/s; and 𝑇 is the 𝜆𝑠
𝑄= (𝑇 − 𝑇𝑠 ) + 𝑄rad , (14)
temperature, K. Δ𝑛 𝑤
Mathematical Problems in Engineering 3
334
348
333.9
346
0 333.8
344
Temperature
0
333.7
Temperature
0.01 0.01 342
0.02 333.6 0.02 340
0.01 0.03 333.5 0.01 0.03 338
X
Z
0.005
Z
0.04 333.4 0.005 0.04 336
0 0.05 0
333.3 0.05 334
0
0
1
1
00
00
2
0.
2
00
0.
00
0.
Y Y
0.
(a) ST model (b) CHT model
2.46
The ST heat dissipating model is usually used in the sim- Y
ulation of the water-cooled PEMFC stack; references [8–10]
use this model to analyze. In addition, different flow fields are A
analyzed, such as parallel, interdigital, and serpentine ones Z 60 : 1
[11–14]. ST model is also applied to compare their advantages Anode diffusion layer
and disadvantages, so as to find out the distributions of the Anode catalyst layer
temperature and the current density. However, as for the air- PEM
cooled PEMFC stack, ST model cannot work properly, as air-
cooled intensity is lower than that of the water-cooled one. Cathode catalyst layer
Generally, straight flow path is employed to dissipate heat, Cathode diffusion layer
which is not uniform. Figure 1 is the surface cooling model:
(a) is ST model and (b) is CHT model; seeing from the outer Figure 2: Model of single fuel cell.
surface of the two models, the former can make the face
temperature uniform, whereas temperature grads emerge in
the latter; in this case, CHT model is similar to that of the close, this will result in slow computation; if the grids are too
air-cooled stack. sparse, the calculation result will not be precise and will be
inferior; therefore, several tests of mesh were done in advance,
3. The Simulation Model of and, finally, the meshing scheme of the simulation model is
Air-Cooled Stack and Optimization of determined. In the length direction, the grid is divided to be
600 sections; in width, the grid is divided to be 130 sections;
Heat Dissipation Structure in the height, current collector, flow channel, diffusion layer,
3.1. The Simulation Model of Air-Cooled Stack. The dimension catalyst layer, and membrane are divided to be sections of
applied in the simulation model of 2 kW air-cooled PEMFC 10, 5, 5, 5, and 5. By simulation, the model can achieve the
stack is 60 mm∗100 mm∗345.68 mm (𝐿∗𝑊∗𝐻 (𝑋∗𝑌∗𝑍)). expected results.
Because of the limitation of the hardware equipments, the
whole stack cannot be simulated. In this case, the simulation 3.2. The Optimization of Heat Dissipation Structure in Air-
model makes correspondent assumption: the heat dissipation Cooled Stack. According to Figure 1(b), the temperature is
conditions of every single fuel cell are uniform, whose height the highest in air-cooled stack terminal; in order to protect
orientation of the stack is 𝑌; the temperature distribution of some parts of the stack from excessive heating that causes
every part of every single cell is also uniform. The reactant damage to proton exchange membrane (PEM), the stack
is ideal gas, whose gas flow in the flow field is the laminar terminal needs changing so as to increase the heat dissipation
flow. According to the assumption, the section of single cell intensity of the stack outlet.
is selected to conduct simulation, whose size 𝐿 ∗ 𝑊 ∗ 𝐻 Figure 3 shows heat dissipation model of 2 kW air-cooled
(𝑋∗𝑌∗𝑍) is set to be 60 mm∗13 mm∗2.46 mm; see Figure 2. stack, in which 36 cooling plates with thickness of 2 mm are
The grid division is of vital importance; FLUENT is inserted in 110 single fuel cells and one cooling plate is added
employed to conduct simulation, supposing the grids are too to every three fuel cells. Channels of the cooling plate and the
4 Mathematical Problems in Engineering
80
380 50(L/2)
80 60(W)
172.84(H/2)
200
Cooling plate
Z Z
Stack Simulation space
Y X
(a) NCAF
80
380 50(L/2)
80 60(W)
172.84(H/2)
Cooling plate
200
Single fuel cell
Z Z
Stack Air-cooling fin Simulation space
Y X
(b) CAF
reactant both undertake the cooling task. Irregular aluminum with a voltage of 0.6 V single cell, whereas it needs a heat
fins are designed in the stack cooling end to reinforce its heat dissipation of 2805 W with a voltage of 0.4 V single cell. In
dissipation of the stack outlet; see Figure 3(b). order to prevent membrane damage of the stack caused by
In order to facilitate CFD computation, the heat quantity large current density, heat dissipation is calculated with a
of every cell is assumed to be equal; in this case, symmetry voltage of 0.4 V. The bulk of the whole stack is 0.00207036 m3 ;
calculation is conducted between the height and the length of therefore, the stack energy source value is 1354837 W/m3 ,
the stack, which reduces computation storage requirements which is used to simulate calculation.
and saves calculating time. A quarter of the stack is put into a
simulation space within a dimension of 380 mm ∗ 200 mm ∗
80 mm, as shown in Figure 3. In the 𝑋 direction, 𝑋 = 0 4. The Development of Air-Cooled Stack
is symmetry plane, and 𝑋 = 80 is convection dissipating
surface; in the 𝑌 direction, 𝑌 = 0 is cooling air inlet and 𝑌 = Besides stack, fuel cell system includes hydrogen supply,
380 is hot air outlet of the stack end; in the 𝑍 direction, 𝑍 = 0 oxygen supply, and water and heat management, which are
is the heat insulation wall and 𝑍 = 200 is symmetry plane. not suitable for lightweight vehicle due to their complex
Figure 3(a) is no cooling aluminum fin (NCAF); Figure 3(b) structure. The fuel cell system development in this paper
is irregular cooling aluminum fin (CAF). The difference of is simplified based upon the above, whose cooling system
which is that the cell dissipating ability differs in different uses air-cooled; namely, the fan is applied to supply cathode
parts of stack. Therefore, irregular cooling fin is set up at the with required oxygen and cools the stack that control its
end of the stack outlet in order to make the stack temperature temperature within a reasonable range. Therefore, a self-
allocation more even. humidifying hydrogen-air PEMFC stack is designed based on
By calculating with the above equations, the necessary the demand of simulation and real vehicle, whose parameters
heat dissipation of the whole stack is approximately 2145 W of the stack performance are shown in Table 1.
Mathematical Problems in Engineering 5
Control system
Air-cooling
stack
Table 1: Parameters of the stack performance. increase speed to prevent the hydrogen from gathering to
avoid danger. When the operation finishes, switch off the
Name Parameters
hydrogen screwed valve. Switch on the nitrogen screwed
Total fuel cell number 110 pieces valve, making the hydrogen channel filled with nitrogen; in
Weight 12 kg the end, block the inlet and outlet of the hydrogen channel,
Rated efficiency (room temperature is preventing the air from entering and destroying the whole
2 kW
293.15 K; relative humidity is 40–70%) stack; finally, turn off the nitrogen screwed valve. Figure 5(b)
Rating voltage 66 V shows oxygen supply system and cooling system. A suite of
Rating current 30 A integrated control system was designed owing to simplifica-
tion, whose requirements are to, respectively, calculate the
Open voltage 112 ± 4 V
volumes of reaction and cooling wind. The controller collects
Hydrogen pressure 0.5–0.6 bars the temperature and pressure of the air inlet, analyzing the
Oxidant, coolant Air (normal pressure) real operation circumstances of the stack; on discovering the
Environmental temperature 273.15∼313.15 K excessive pressure of the air supply and the stack overheat, the
Environmental humidity 20–90% signals are sent to the air supply solenoid valve, shutting the
Stack temperature 298.15∼333.15 K air supply, meanwhile, notifying the cooling fan, reinforcing
the air cooling in order to guarantee the stack security. When
Humidifying method Self-humidifying
the operation finishes, block the air inlet and outlet to prevent
other things from entering and destroying the stack.
In the designing and manufacturing procedure, refer to
the simulation requirements without adding cooling fin at the 5. Results and Discussions
end of the cooled stack, whose operating temperature is not
superheat. If superheat, it will result in fracture of the PEM 5.1. The Performance Parameters’ Effect on Stack
that leads to accidents. The fuel cell system structure mainly
contains five systems: air supply and cooling, hydrogen (1) Relative Humidity (RH) Effect on the Air-Cooled PEMFC.
supply, security, stack, and control, which are shown in Three flow fields are applied in the simulation, including the
Figure 4. parallel flow, serpentine flow, and interdigital flow. The RH
Figure 5 shows the operating system of the air-cooled influence on the stack performance is analyzed under the
stack. Cathode applies air with self-humidifying and anode conditions with single cell voltage of 0.6 V, parallel flow field,
applies pure hydrogen without humidifying. In order to and ST model.
guarantee the normal operation of the stack, the heat and gas Figure 6 shows the current density of the stack with dif-
management is mainly considered when they are designed. In ferent RH, whose anode is not humidified. The RH of cathode
addition, security control system is designed so as to prevent range is from zero to 100%, which is simulated gradually;
the hydrogen leakage that results in accidents. Figure 5(a) in order to reduce the simulation calculation, RH of 30%,
shows the hydrogen supply and security system, whose stack 50%, 80%, and 100% is selected to be analyzed. Figure 6
controller controls solenoid valve and ventilating fan by shows the important effect on the stack performance with
collecting the signals of inlet temperature and pressure, mass humidification in the cathode. Without humidity, the current
flow, and hydrogen security alert. When noticing problems density of the stack is 0.3186 A/cm2 , when humidifying the
that emerge in the hydrogen supply system, such as hydrogen cathode with a RH of 30%, the current density of the stack is
leakage, extreme pressure, or temperature, the controller 0.6042 A/cm2 , and when the RH is of 80%, the current density
immediately sends signals to the solenoid valve, which is to of the stack reaches the maximum 0.6042 A/cm2 . When
be blocked. If hydrogen leaks, ventilating fan is required to the RH reaches 100%, the current density drops slightly. In
6 Mathematical Problems in Engineering
Controller
Ventilating
Controller
fan Pressure Temperature
sensor sensor Cooling
fan Pressure
sensor Temperature
H2 inlet sensor
H2 annunciator Air outlet
H2 outlet PEMFC
PEMFC Air inlet
MFC
Mass flow
Solenoid Precise control MFC
valve decompression valve Solenoid
valve valve Pressure Mass flow
Screwed
valve N2 tank reducing control
regulator valve
Screwed Pressure Screwed
valve relief valve valve
H2 tank Air blower
Air filter
Pressure relief valve
Signal flow
H2 flow Signal flow
N2 flow Air flow
(a) Hydrogen supply system and security system (b) Oxygen supply system and cooling system
100 2000
Current density (A/cm2 )
0.6
80
Voltage (V)
Power (W)
1500
60
0.5
1000
40
0.4 20 500
0 0
0.3 0 10 20 30 40
0 20 40 60 80 100 Current (A)
RH (%)
Test power Test voltage
Figure 6: Current density versus RH. Simulation voltage Simulation power
355 15
350 12
Water content
345 9
T (K)
340 6
335 3
330 0
0 0.01 0.02 0.03 0.04 0.05 0.06 0 0.01 0.02 0.03 0.04 0.05 0.06
X (m) X (m)
CHT CHT
ST ST
(a) Temperature curve (b) Water content curve
Figure 8: 𝑌 = 1.23 mm, the characteristic curves of the temperature and water content of membrane along channel.
Figure 8(b) shows the water content situation of PEM higher than the other two flow fields. The inner temperature
along the channel, as the temperature of CHT mode is of the parallel and the interdigital fields is closer to higher
high; therefore, its water content is low, whereas the stack outlet temperature.
temperature of ST mode is well controlled with high water Figure 9(b) shows that the water content of PEM in the
content. Yet, When 𝑋 reaches 30 mm, the water content parallel flow field is higher, probably because of the better
can increase a little and reach saturation, which manifests stack dissipating effect, and the reactant gas can also take
that water flooding produced in ST mode. Furthermore, two away some heat; moreover, it is difficult for the other two flow
dissipating modes produce different current densities; the fields to dissipate heat, which leads to the high temperature of
current density of ST mode is 0.6342 A/cm2 , but the current cell.
density of CHT mode is 0.5198 A/cm2 . The current densities of PEMFC are, respectively,
Therefore, ST mode is closer to perfect heat dissipating 0.51983 A/cm2 in the parallel, 0.5336 A/cm2 in the serpentine,
mode and its stack can equally dissipate heat, the maximum and 0.516 A/cm2 in the interdigital fields. The current density
reactant temperature is in the membrane accessory, and the of the three flow fields changes little under the same
current density produced is high; yet, when operating with conditions, the serpentine field is better, mainly because of
low temperature, it tends to produce water flooding. The CHT its higher temperature.
mode is closer to air-cooled stack, whose outlet temperature There are certain differences between air-cooled and
is too high to dissipate heat, which needs to increase air- water-cooled PEMFC, whose heat dissipating intensity varies.
cooling. Thus, if the air-cooled PEMFC emphasizes uniform reaction
in flow field that continuously hovers in the cell, it can be
(4) Different Flow Fields Affect PEMFC under CHT Model. The an obstacle to heat dissipation, especially when the stack is
flow field of air-cooled PEMFC is also vital; different flow lack of air-cooled plate. In this case, the parallel flow field is a
fields have an influence on the PEMFC inner temperature better choice.
distribution, the PEM water content, and the PEMFC current
density; Figure 9 is three different flow fields, which show the 5.2. The Optimization of Heat Dissipation Structure for Air-
temperature and water content of PEM along channel when Cooled Stack. Figure 10 shows that the inlet wind speed is
single fuel cell voltage is 0.6 V. 0.5 m/s; when 𝑋 is 25 mm, the temperature distribution in
Figure 9(a) shows that the serpentine flow field, whose stack outlet terminal, whose temperature of both terminals
temperature is the highest in the central PEM of the three is about 6 K higher than that of the central temperature at the
flow fields; therefore, it is not optimal for air-cooled stack, height of direction 𝑍, which indicates that the heat dissipation
especially when cooling capacity is insufficient. The reasons of both terminals is not perfect; therefore, it needs to enhance
are that heat reactant discontinuously operates in the PEMFC heat dissipation in the high temperature area under the same
and that air-cooled intensity is insufficient, which cause the heat dissipation conditions; this is the reason to add irregular
overheat temperature of the PEMFC, approximately 10 K cooling fins.
8 Mathematical Problems in Engineering
10
356
354
8
352
Water content
350 6
T (K)
348
4
346
344 2
342
0
0 0.01 0.02 0.03 0.04 0.05 0.06 0 0.01 0.02 0.03 0.04 0.05 0.06
X (m) X (m)
Parallel Parallel
Serpentine Serpentine
Interdigital Interdigital
(a) Temperature curve (b) Water content curve
Figure 9: 𝑌 = 1.23 mm, the curves of the temperature and water content of membrane along channel.
360
360
V = 1 m/s
V = 1 m/s
345 V = 2 m/s 345 V = 2 m/s
V = 3 m/s V = 3 m/s
T (K)
T (K)
330 330
315 315
300 300
0 0.05 0.1 0.15 0.2 0 0.05 0.1 0.15 0.2
Z (m) Z (m)
NCAF CAF
(a) (b)
Figure 11: 𝑋 = 25 mm, different air-cooling speed, the temperature distribution in stack’s outlet terminal.
338.68 336.53
336.63 336.53
336.60 332.86
336.47
332.86
336.42
336.39 332.84
333.89 332.50
Temperature
Temperature
331.16 332.44
328.42 331.16
325.68
327.05
322.95
324.32
320.21
317.47 320.21
314.74 317.47
312.00 313.37
298.58
299.03
298.01
298.03
298.00
NCAF
CAF
dissipating condition, whose stack is able to better dissipate 5.3. Stack Temperature Analysis in Test. According to some
heat. Therefore, the temperature difference of a single cell is references, the operating temperature of the PEMFC stack
small. can reach a height exceeding approximately 390 K [19, 20],
By simulation, there is a great relationship among stack which can enhance the stack efficiency, yet considering
performance, flow field, temperature, and humidity. As for the security of the stack, whose operating temperature is
the air-cooled stack with air in the cathode, whose anode is decreased during the process of designing and manufacturing
pure hydrogen and cathode with a RH of 80%, the parallel that is illustrated in Section 4.
flow field can improve its performance. The performance parameters of the stack change with
Under the same operating conditions, according to the time under the rating load testing, as is shown in Figures
temperature distribution, the irregular cooling fins are added 13 and 14. After starting for 64 seconds, the stack begins to
at the stack terminals. It will be beneficial to the uniform work normally, whose inlet temperature is around 304.15 K,
distribution of temperature in single cell and prolong the 42 seconds later, it starts to add rating load to the stack, whose
lifespan of the stack. voltage reaches around 66 V, after about 20 seconds, the
10 Mathematical Problems in Engineering
120 40 333.15
35
100 323.15
30
Temperature (K)
80
Current (A)
Voltage (V)
25 313.15
60 20 303.15
15
40 293.15
10
20
5 283.15
0 0
0 50 100 150 200 250 300 273.15
0 100 200 300 400 500 600
Time (s)
Time (s)
Stack voltage
Toutlet
Stack current
Tinlet
Figure 13: The stack current and voltage in the testing of constant
load. Figure 15: The inlet and outlet temperature of stack in the testing of
step load.
6. Conclusions
323.15
Conclusions according to simulation and test are as follows.
Temperature (K)
313.15
(1) Simulation indicates that the CHT model is suitable
303.15 for the study of air-cooled stack because surface temperature
293.15 of the fuel cell continuously increases from the inlet of 333 K
to the outlet of 349 K, and the temperature distribution of the
283.15
stack is similar to that of air-cooled fuel cell.
273.15 (2) The structure of the parallel flow field is simple, which
0 50 100 150 200 250 300
is suitable for air-cooled stack. Because, under the voltage of
Time (s)
0.6 V, the simulation shows that the temperature of serpentine
Toutlet flow field is 10 K higher than the other two kinds of flow fields;
Tinlet yet the water content Cw is the minimum; at this time, the
Figure 14: The inlet and outlet temperature of stack in the testing of
temperature is high and the membrane is dry; interdigital
constant load. flow field has a mutation in the outlet terminal, which shows
that the poor draining of the outlet terminals whose Cw is the
maximum 10, which is 3 times of that of the outlet.
(3) Optimization of the heat dissipating structure in
current lagged for several seconds and reaches approximately
the outlet terminals of stack can make the distribution of
32 A, and afterwards, the stack voltage maintains steady;
the current tends to be flat as the temperature increases. the stack temperature uniform, reducing the fan energy
After running for 300 seconds, the outlet temperature of the consumption. The central temperature of the NCAF stack is
stack reaches 321.15 K, but the inlet one is 309.85 K, which 6 K lower than that of the edge by cooling it with a wind
indicates that the stack temperature is 333.15 K lower than speed of 0.5 m/s, indicating that the heat dissipation of the
the required operating temperature that can dissipate heat stack is not uniform. Under the same conditions of radiating
better, reflecting the steady operating of the stack under rating capacity, whose wind speed of 2 m/s can satisfy the cooling
power. requirements of CAF stack, yet, NCAF stack requires a wind
Figure 15 reflects changes curves for the inlet temperature speed of 3 m/s.
of the stack under step load. The stack temperature does not (4) The air-cooled stack tends to produce water flooding
change abruptly because switching the load cannot imme- under low operating temperature that results in the stack
diately change the temperature, yet, with the load increases, power decrease; in this case, the operating temperature
the stack heat increases as well, whose maximum stack requires improving in the near future so as to perfect the
temperature reaches 323.15 K, which is controlled within the manufacturing of the air-cooled stack.
stack operating range.
Based on the testing analysis, the operating temperature
of the stack is indeed insufficient and easy to produce water Conflict of Interests
flooding, leading to the decrease of the efficiency; therefore,
there exists a space to improve the manufacturing of the air- The authors declare that there is no conflict of interests
cooled stack with higher efficiency. regarding the publication of this paper.
Mathematical Problems in Engineering 11
International
Journal of Journal of
Mathematics and
Mathematical
Discrete Mathematics