Pratt & Whitney


JT8D MAINTENANCE MANUAL (PN 481671)

COMBUSTION CHAMBER OUTER CASE − MAINTENANCE PRACTICES−00

Task 72−41−11−220−001:

1. Combustion Chamber Outer Case Inspection

A. Combustion Chamber Outer Case Rear Flange And Bosses

(1) Special inspections are necessary for the combustion


chamber outer case Ps4 boss, fuel drain bosses, and
rear flange. These inspections are collected in two
Alert Service Bulletins, as follows:

(a) For combustion chamber outer case PN 490547,


542155, 616315, 728829, 728829−001, 730413,
730413−001, 730414, 730414−001, 767197, 767279,
and 767279−001, refer to ASB6228 for necessary
inspections.

(b) For combustion chamber outer case PN 796761,


796761−002, 796761−003, 805412, 805412−001,
805412−002, 806675, 806675−001, 806675−002,
808125, 808125−001, and 808125−002, refer to
ASB6230 for necessary inspections.

(c) For combustion chamber outer case PN 806748 there


are no special inspections necessary.

#72−41−11
MNT PRAC−00
Page 201/202
EFF: −ALL OCT 15/02
200

Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3).