Activity File Client HESS Project UJUNG PANGKAH DEVELOPMENT OFFSHORE PHASE II Subject CATHODIC PROTECTION DESIGN Rev AFC
Results Summary (DNV RP B-401)
Mass Requirement 1 Anodes Total Number of Required Anodes #DIV/0! Anodes Current Requirement #DIV/0! Anodes
Input - Anode Data Input - Current Densities
Alloy Weight Wu 118.4 lb Structure above mudline Life L 25 Yr Mean Current Density Idm(s) 0.0050 amp/ft2 Length ℓ in Initial Current Density Idi(s) 0.0140 amp/ft2 Height H in Final Current Density Idf(s) 0.0080 amp/ft2 Top Face FT in Structure below mudline Bottom Face FB in Mean Current Density Idm(bm) 0.0000 amp/ft2 Internal Steel Diameter Di in Initial Current Density Idi(bm) 0.0000 amp/ft2 Utilization Factor UF 0.9 Final Current Density Idf(bm) 0.0000 amp/ft2 Electrochemical Capacity Ur 907 amp-hr/lb Coating Breakdown Factor Anode - Seawater Potential Va 1.05 Volts Mean Fc(m) 0.1700 Structure - Seawater Potential Above Mudline Vs 0.80 Volts Initial Fc(i) 0.0200 Structure - Seawater Potential Below Mudline Vs1 Volts Final Fc(f) 0.3200 Seawater Resistivity r' 9.843 ohm.in Input - Additional Current Requirement Allowances Input - Jacket Data (includes 5% of contingency) Conductor Allowance Ic 0 amp/well Surface area coated area SA(c) 0 ft2 Number of Conductor Wells nc 0 Surface area above mudline SA(s) 375 ft2 Riser Allowance Ir 0 amp/riser Surface area below mudline SA(bm) 0 ft 2 Number of Attached Risers nr 0 Calculation - Mass Requirement Consumption Rate of Anode E 9.65 lb/amp-yr Ref: National Association of Corrosion Engineers, Standard RP0176-83, "Corrosion Control of Steel, Fixed
Above Mudline (coated area included) Offshore Platforms Associated with Petroleum
Mean Current Requirement Im 0.0093863 amps Production", May 1983
Net Mass of Required Anodes W 2.52 lb Required Number of Anodes Ns 1 Det. Norske Veritas, RP B401, "Cathodic Protection Design", March 1986 Below Mudline Mean Current Requirement Im 0.00 amps Net Mass of Required Anodes W 0.00 lb W .UF L= Required Number of Anodes Nbm 0 E.Im
Total Number Anodes Reqd N 1
Calculation - Current Requirement
Perimeter of Cross-Section c 0.00 in Area of Cross-Section Ac 0.00 in2 ΔV Driving Voltage Above Mudline DV 0.25 V I= Ra Driving Voltage Below Mudline DV1 1.05 V i) Initial Current Req.above the mudline (coated area included) Effective Radius Circuit Resistance r Ra 0.00 in #DIV/0! ohm Ra = r' 2 π⋅ℓ [ 4ℓ ln −1 r ] Current Output Capacity I #DIV/0! A/Anode
424626667.xls Page 1 of 7 Rev AFC02
WORLEY STANDARD CALCULATION Cathodic Protection Requirement Calculations
Project no 402000-01302 Calc no
Activity File Client HESS Project UJUNG PANGKAH DEVELOPMENT OFFSHORE PHASE II Subject CATHODIC PROTECTION DESIGN Rev AFC
Initial Current Requirement Ii 5.26 amps
Number of Initial Anodes Reqd Ni #DIV/0!
424626667.xls Page 2 of 7 Rev AFC02
WORLEY STANDARD CALCULATION Cathodic Protection Requirement Calculations
Project no 402000-01302 Calc no
Activity File Client HESS Project UJUNG PANGKAH DEVELOPMENT OFFSHORE PHASE II Subject CATHODIC PROTECTION DESIGN Rev AFC
Calculation - Current Requirement Above the Mudline
ii) Final Current Req. above the mudline (coated area included) Density of Anode Material r #DIV/0! lb/ft3 Final Weight Wf 11.84 lb Final Effective radius r #DIV/0! in Circuit Resistance Ra #DIV/0! ohm Current Output Capacity I #DIV/0! A/Anode Final Current Requirement If 3.00 amps Number of final Anodes Reqd Nf #DIV/0!
Anodes Reqd Above Mudline Ns #DIV/0!
i) Initial Current Requirement below the mudline
Effective Radius r 0.00 in Circuit Resistance Ra #DIV/0! ohm Current Output Capacity I #DIV/0! A/Anode Initial Current Requirement Ii 0.00 amps Number of Initial Anodes Reqd Ni #DIV/0!
ii) Final Current Requirement below the mudline
Density of Anode Material r #DIV/0! lb/ft3 Final Weight Wf 11.84 lb Final Effective radius r #DIV/0! in Circuit Resistance Ra #DIV/0! ohm Current Output Capacity I #DIV/0! A/Anode Final Current Requirement If 0.00 amps Number of final Anodes Reqd Nf #DIV/0!
Anodes Reqd Below Mudline Nbm #DIV/0!
Total Anodes Required N #DIV/0!
Conclusions
424626667.xls Page 3 of 7 Rev AFC02
WORLEY STANDARD CALCULATION Cathodic Protection Requirement Calculations
Project no 402000-01302 Calc no
Activity File Client HESS Project UJUNG PANGKAH DEVELOPMENT OFFSHORE PHASE II Subject CATHODIC PROTECTION DESIGN Rev AFC
Results Summary (HESS Specification)
Summary of surface area
Zone 2 (m2) Zone 3 (m2) Zone 4 (m2)
0.00 33.22 0.00
Current Demand Calculation
Surface Area1) Current Densities Current Demand Zones m2 ft2 mA/ft2 mA Zone 2 - EL (+) 3.00m to (-) 1.50m 2) 0.00 0.00 6 0.00 Zone 3 - EL (-) 1.50m to (-) 12.20m 34.88 375.49 6 2252.91 Zone 4 - EL (-) 12.20m to (-) 104.20m 0.00 0.00 2 0.00 TOTAL CURRENT DEMAND 2.25 A Note: 1. Includes 5% of contingency 2. Submerged coated steel is 10% of total coated area
Anode Requirement
N = [(ix * Ax * 1/1000 + Ic) * T] / [E * W * u]
where N = Number of anodes
ix = current demand in region x (mA/ft2) Ax = area in region x (ft2) T = design life (hours) = 25 years = 219000 hours
E = energy capability (amp-hr/lb) = 907 amp-hr/lb
W = net weight of one anode (lb) = 118 lb
u = utilization factor = 0.9
Ic = conductor x allowance x no of conductor (amp)
ix * Ax = 2.25 A
Therefore
N= 5 ea
Anodes required based on HESS Specification are 5 ea
424626667.xls Page 4 of 7 Rev AFC02
PLATFORM No Item Unit WHP-B AUP CPP 1 Surface Area - Zone 2 m2 844.614 552.578 - Zone 3 m2 1541.413 1061.532 - Zone 4 m2 3122.703 1615.637 Rev By Checked Date Comments A