You are on page 1of 10

SITRANS I

supply units and


input isolators
6
6/2 Product overview

6/3 SITRANS I
6/3 Isolating power supply HART (FSK)
6/5 Transmitter power supply/input isolator
6/8 Output isolator HART (FSK)

Siemens FI 01 · 2003
Supply units and input isolators
Product overview
Supply units and input isolators
Application Description Catalog
page
Isolating power supply HART (FSK)

Isolating power supply for two-wire SITRANS I 6/3


transmitters Isolating power supply HART for rail
mounting, with intrinsically-safe input.

Transmitter power supply/input isolator

Power supply for two-wire transmitters. SITRANS I 6/5


As input isolator for transformation and Transmitter power supply/input isolator
electrical isolation of standard signals. for rail mounting, adaptable to various
applications.

6 Output isolator HART (FSK)

Output isolator for control of actuators SITRANS I 6/8


Output isolator HART for rail mounting,
with intrinsically-safe output.

6/2 Siemens FI 01 · 2003


Supply units and input isolators
SITRANS I
Supply units and input isolators
Isolating power supply HART (FSK)

■ Features
7 Compact plastic housing (22.5/35 mm wide) with screw-type
plug connector to IP 20 for mounting on 35 mm rail to DIN EN
50 022
7 Power supply 24 V AC/DC (universal current) or
7 Flexible low-voltage supply from wide-input-range power sup-
ply 95 to 253 V AC
7 Power supply status indication via LED on front
7 HART (FSK) communication via communication sockets on
the front
7 Electrical isolation between input, output and power supply
7 Intrinsically safe input circuit

■ Mode of operation (Fig. 6/2)


Fig. 6/1 SITRANS I isolating power supply HART (FSK) The connected transmitter is supplied intrinsically safe via a lim-
itation circuit (1), rectifier (2) and a transformer (3). The current
■ Application is mirrored to the output.

The power supply for 7NG4122 SMART transmitters is used to For communication with the transmitter, a HART communicator
supply two-wire transmitters that are operated in intrinsically or HART modem can either be connected across the output re-
sistance (at least 250 Ω) or to the communication sockets con-
safe areas. It supports communication with digital transmitters
via a host computer or HART communicator (hand-held commu- nected in parallel with the output (HK). The three output
terminals enable the output circuit to be connected with or with-
nicator).
out the internal communication resistance (250 Ω).

1 Limitation circuit 6 8
2 Rectifier
3 Transformer
PWR
4 Rectifier
5 Output amplifier
6 Power transformer
7
8
LED green (PWR)
Rectifier 1 2 3 4 5
250 W
HK
6
E Input signal +6
A Output signal
E A
HK Connector for communication -5
PWR Power supply
+4

Fig. 6/2 Block diagram: Operation of SITRANS I isolating power supply


HART (FSK)

■ Technical data Accuracy (continued)


Input Influencing effect
Input signal 4 to 20 mA • of ambient temperature w 0.2%/10 K
Input resistance Approx. 320 Ω • of change in load resistance w 0.1%/100%
Min. voltage available at 20 mA 16 V • of change in supply w 0.1%/10%
Output Rated operating conditions
Output signal 4 to 20 mA Ambient conditions
Open circuit voltage < 24 V • Ambient temperature -20 to +65 °C
Characteristic Linear • Storage temperature -40 to +85 °C
Load • Functional temperature -25 to +70 °C
• between +4 and -5 ≤ 750 Ω
• between -5 and +6 ≤ 500 Ω • Degree of protection to EN 60 529 IP 20
Communication Bidirectional transfer of HART sig- • Electromagnetic compatibility
nals - Interference immunity According to EN 50 082-2 and
NAMUR NE21
• Communication range 3.6 to 23 mA - Emitted interference According to EN 50 081-1
Input monitoring
Design
• Signal for input short circuit 23 to 30 mA
• Signal for open circuit < 3.6 mA Construction Compact plastic housing for rail
mounting
Accuracy
Weight Approx. 0.15 kg
(related to full-scale value of output
signal) Dimensions See page 6/4
Linearity w 0.15% Enclosure material PC/GV 25
Output signal ripple UPP < 1% Electrical connection Plug-in screw terminals, max.
2.5 mm²
Rise time T90 w 0.3 ms

Siemens FI 01 · 2003 6/3


Supply units and input isolators
SITRANS I
Isolating power supply HART (FSK)

■ Technical data (continued)


Certificates and approvals
Power supply
CENELEC According to DIN EN 50 014 and
Functional extra-low voltage According to DIN 57 100, DIN EN 50 020
VDE 0100 Part 410 Intrinsically safe input circuit
• With safe isolation w 50 V AC, w 120 V DC • "Intrinsically safe" type of protection II (1) G EEx [ia/ib] IIB
Universal current 24 V AC/DC 24 V AC ± 15%, 47 to 63 Hz - Maximum output voltage U0 27.9 V
20 to 32 V DC - Maximum output current I0 89 mA
AC voltage 95 to 253 V AC, 47 to 63 Hz - Maximum output power P0 620 mW
- Maximum external capacit. C0 651 nF
Power consumption at rated voltage 24 V DC, < 2.5 W
- Maximum external inductance L0 16 mH
24 V AC, < 3 VA
230 V AC, < 3.5 VA • "Intrinsically safe" type of protect. II (1) G EEx [ia/ib] IIC
Permitted residual ripple within the - Maximum output voltage. U0 27.9 V
voltage limits UPP w 2.5 V - Maximum output current I0 89 mA
- Maximum output power P0 620 mW
Electrical isolation between Power supply and input - Maximum exter. capacitance C0 81 nF
Power supply and output - Maximum external inductance L0 2.3 mH
Input and output
Conformity certificate TÜV 99 ATEX 1498
• Operational voltage acc. to
DIN 61010 Extern. standards and guidelines
- for 7NG4122-1BA10 (230 V) 250 V AC Low-voltage guideline According to DIN EN 61 010
- for 7NG4122-1AA10 (24 V) 150 V AC
• Pollution severity 2
• Overvoltage category II
• Test voltage for 7NG4122-1AA10 ■ Ordering data Order No.
(24 V) between SITRANS I isolating power supply HART } 7NG4122 - 1 7 A10
- Power supply and input 1.5 kV AC (FSK)
- Input and output 1.5 kV AC Rail-mounted to supply two-wire trans-
- Power supply and output 500 V AC mitters, output 4 to 20 mA, intrinsically
• Test voltage for 7NG4122-1BA10 safe input 4 to 20 mA with EEx ia/ib IIB/
(230 V) between IIC
- Power supply and input 2.3 kV AC
- Input and output 2.3 kV AC Power supply
- Power supply and output 2.3 kV AC • 24 V AC/DC (22.5 mm width) } 7NG4122 - 7A
• 95 to 253 V AC (35 mm width) } 7NG4122 - 7B
} Available ex stock.

6
35 22,5 117,5

1 2 3 4 5 6
- + + - +
1 2 3 4 5 6
PWR
(~) (~)
PWR
1 NC 2 3

11 12
79

79

104
92

84

HK HK
- +

4
7 8 9 10 11 12

104,5
AC 230V UC 24V

1 Power supply (PWR)


2 Output without internal communication resistance (terminals +4 and -5)
3 Output with internal communication resistance (terminals -5 and +6)
4 Input
NC Not connected

Fig. 6/3 Dimension drawing and connections

6/4 Siemens FI 01 · 2003


Supply units and input isolators
SITRANS I
Supply units and input isolators
Transmitter power supply/input isolator
7 Input signal can be selected by appropriate connection of the
input terminals (supplying, current input, voltage input)
7 Output signal can be changed over (current output, voltage
output) by means of plug-in jumpers below the housing base
7 Two-wire transmitters are supplied
7 Transfer function can be switched over 0/4 to 20 mA or 0/2 to
10 V / 0/4 to 20 mA or 0/2 to 10 V by means of a measuring
range switch on the front
7 Electrical isolation between input, output and power supply

■ Mode of operation
The input signal is applied to the respective input amplifier and
converted by a microcontroller in accordance with the transfer
function before reaching the output amplifier via an opto-cou-
pler. The signal is amplified and output again as a standard sig-
Fig. 6/4 SITRANS I transmitter power supply / input isolator nal (current/voltage).

■ Application When operating as a transmitter power supply, the connected


transmitter is supplied and the transmitter load current is applied
The 7NG4123 transmitter power supply and input isolator is to the input amplifier (1). The transfer function can be switched
used for the transformation and electrical isolation of standard over (0/4 to 20 mA or 0/2 to 10 V / 0/4 to 20 mA or 0/2 to 10 V) by
signals. When it is implemented as a transmitter power supply, it means of a measuring range switch. Calibration is not necessary
is used for supplying power and transferring signals to two-wire because all characteristics are stored in the microcontroller.
transmitters. The electrical isolation ensures that the power supply, input cir-
cuits and output circuits are completely decoupled for low-cur-
■ Features rent transfer of the measured values.
7 Compact plastic housing (22.5/35 mm wide) with screw-type
plug connector to IP 20 for mounting on 35 mm rail to DIN
EN 50 022
7 Power supply status indication via LED on front

LED 9

A Output 6
E Inputs E 6 7 8 10
1 Power supply PWR
2 Output
3 Voltage input 5 1
4 Current input
5 Supplying input
6 Limiter
7 Electrical isolation
8 Chopper/switching power supply
9 LED green (PWR) 15 14 13 12 11 A
10 Rectifier mP U
11 U/U, I transformer 4 2
System
12 Output amplifier U,I
13 Opto-coupler
14 Microcontroller
15 Input amplifier (I) 16 17
16 Input amplifier (U)
17 Range switch 3
PWR Power supply

Fig. 6/5 Block diagram: Operation of SITRANS I transmitter power


supply and input isolator

Siemens FI 01 · 2003 6/5


Supply units and input isolators
SITRANS I
Transmitter power supply/input isolator

■ Technical data Rated operating conditions


Input Ambient conditions
Input isolator • Ambient temperature -20 to +65 °C
• Input signal • Storage temperature -40 to +85 °C
- Current 0/4 to 20 mA • Functional temperature -25 to +70 °C
- Voltage 0/2 to 10 V • Degree of protection EN 60 529 IP 20
• Input resistance • Electromagnetic compatibility
- Current 60 Ω - Interference immunity According to DIN EN 50 082-2 and
- Voltage W 1 MΩ NAMUR NE21
• Max. permissible input current 30 mA - Emitted interference According to DIN EN 50 081-2
• Max. permissible input voltage 15 V Power supply
Transmitter power supply Functional extra-low voltage DIN 57 100, VDE 0100 Part 410
• Input signal • With safe isolation < 50 V AC, < 120 V DC
- Current 4 to 20 mA
• Universal current 24 V AC/DC 24 V AC ± 10%, 47 to 63 Hz
• Supplied voltage W 15 V at 20 mA 18 to 32 V DC
• Input resistance 100 Ω • AC voltage 95 to 253 V AC, 47 to 63 Hz
• Signal limiting Power consumption at rated voltage 24 V, 1.9 W DC
- Current w 30 mA 24 V AC, 2 VA
- Voltage w 21 V 230 V AC, 3.5 VA
Output Residual ripple within the voltage
Output signal limits (DC) UPP w 2.5 V
• Current 0/4 to 20 mA Electrical isolation between Power supply and input
Input and output
• Voltage 0/2 to 10 V Power supply and output
Characteristic Rising, linear • Operational voltage acc. to
Load DIN 61 010
• with current w 750 Ω - for 24 V 50 V AC
- for 230 V 50 V AC
• with voltage W 2 kΩ
• Pollution severity 2
Signal limiting
• Overvoltage category II
• Current w 30 mA
• Test voltage for 24 V AC/DC
• Voltage w 21 V between
Output response - Input and output 500 V AC
- Power supply and output 500 V AC
• to short-circuit or open-circuit in-
6 put
- output 4-20 mA or 2-10 V: 3.4 to 3.6 mA or
- Power supply and input
• Test voltage for 230 V AC between
500 V AC

(input 4-20 mA or 2-10 V) 1.7 to 1.8 V - Input and output 500 V AC


- output 4-20 mA or 2-10 V: 4 mA or - Power supply and output 2.3 kV AC
(input 0-20 mA or 0-10 V) 2V - Power supply and input 2.3 kV AC
- output 0-20 mA or 0-10 V: 0 mA or External standards and guide-
(input not relevant) 0V lines
• to short-circuit across input W 21 mA Low-voltage guideline According to DIN EN 61 010
(supplying)
- for load w 600 Ω W 22 mA or W 11 V
Accuracy ■ Ordering data Order No.
(related to full-scale value of output SITRANS I transmitter power supply / } 7NG4123 - 1 7 N00
signal) input isolator
Linearity w 0.1% Rail-mounted to supply two-wire trans-
mitters and electrical isolation and
Zero point / amplification w 0.1%
transformation of standard signals
Long-term stability w 0.05% / year Input/output signals can be selected as
Output signal ripple w 1% required via measuring range switch on
front
Rise time T90 w 150 ms
Influencing effect Power supply
• of ambient temperature w 0.15%/10 K • 24 V AC/DC (22.5 mm width) } 7NG4122 - 1A
• 95 to 253 V AC (35 mm width) } 7NG4122 - 1B
• of change in load resistance w 0.1%/100%
• of change in supply w 0.05%/10% } Available ex stock

Design
Construction Plastic housing
Weight Approx. 0.2 kg
Dimensions See page 6/7
Enclosure material PC/GV 25
Electrical connection Plug-in screw terminals,
max 2.5 mm²

6/6 Siemens FI 01 · 2003


Supply units and input isolators
SITRANS I
Transmitter power supply/input isolator

35 22,5 117,5

1 2 3 4 5 6
- + - +
1 23 4 5 6 (~) (~)
PWR PWR
1 NC NC 2

7 8 9 10 11 12
79

79

104
92

84
- + - + - +

3 4 5
7 8 9 101112

104,5
AC 230V UC 24V

1 Power supply (PWR) 4 Current input 0/4 to 20 mA


2 Output 5 Loop powered input 4 to 20 mA
3 Voltage input 0/2 to 10 V NC Not connected.

Fig. 6/6 Dimension drawing and connections

35 PWR-LED 22,5
Range switch (on front plate)

Position Input Output “I” Output “U“


PWR PWR 0 4 to 20 mA 4 to 20 mA 2 to 10 V
1 4 to 20 mA 0 to 20 mA 0 to 10 V
2 0 to 20 mA 4 to 20 mA 2 to 10 V
3 0 to 20 mA 0 to 20 mA 0 to 10 V
79

79

4 2 to 10 V 4 to 20 mA 2 to 10 V
5 2 to 10 V 0 to 20 mA 0 to 10 V
6
7
0 to 10 V
0 to 10 V
4 to 20 mA
0 to 20 mA
2 to 10 V
0 to 10 V
6
8 Not used
9 Not used
(on delivery)

Range switch

Plug-in jumpers
The plug-in jumpers are accessed by unscrewing the housing socket.

Ouput I: all jumpers in position "I" (on delivery)


Output U: all jumpers in position "U"

Output
I U

Rear view

Fig. 6/7 Plug-in jumpers

Siemens FI 01 · 2003 6/7


Supply units and input isolators
SITRANS I
Output isolator HART (FSK) Supply units and input isolators

7 Power supply 24 V AC/DC (universal current) or


7 Flexible low-voltage supply from wide-input-range power
supply 95 to 253 V AC
7 Power supply status indication via LED on front
7 Input or output signal 4 to 20 mA
7 HART (FSK) communication via communication sockets on
the front
7 Electrical isolation between input, output and power supply
7 Intrinsically safe input circuit

■ Mode of operation
The input current signal is filtered and amplified. After pulse-
width modulation, the input signal is transferred to the output
side via an opto-coupler. A low pass filter followed by an ampli-
Fig. 6/8 SITRANS I output isolator HART (FSK) fier transforms the signal into a standardized output variable.
The communication signals of a connected HART communicator
■ Application are separated from the signal at the input, transferred electrically
The 7NG4130 output isolator electrically isolates an input current isolated to the output and added to the output signal again.
signal which originated in the non-intrinsically safe area from the Transmission via frequency shift keying is bidirectional and inde-
intrinsically safe output circuit. It supports bidirectional commu- pendent of the signal path. The HART communicator can either
nication between an actuator and a host computer or HART be connected across the input resistance (at least 250 Ω) or to
communicator (hand-held communicator). the communication socket on the non-intrinsically safe side.

■ Features
7 Compact plastic housing (22.5/35 mm wide) with screw-type
plug connector to IP 20 for mounting on 35 mm rail to DIN
EN 50 022.

LED 2
1 Rectifier
6 2
3
LED green(PWR)
Chopper
1 3 4

4 Transformer PWR
5 Communications resistor
6 Input amplifier
7 Electrical isolator
8 Output amplifier
HK
9 Ex limiter
10 Communication isolator 5 6 7 8 9
11 Signal coupling
E Input signal E A
A Output signal
HK Front connector for communication
PWR Power supply 10 11

Fig. 6/9 Block diagram: SITRANS I output isolator HART (FSK)

6/8 Siemens FI 01 · 2003


Supply units and input isolators
SITRANS I
Output isolator HART (FSK)

■ Technical data Electrical isolation between Power supply and input


Input and output
Input Power supply and output
Input signal • Operational voltage acc. to
DIN 61010
• Current 4 to 20 mA
- for 24 V 150 V AC
Transferred from HART (FSK) sig- - for 230 V 250 V AC
nals in the Ex zone
• Pollution severity 2
Input resistance (current HART w 270 Ω
• Overvoltage category II
FSK)
• Test voltage for 24 V AC/DC
Communication range 3.6 to 22 mA
between
Output - Input and output 1.5 kV AC
Output signal 4 to 20 mA - Power supply and output 1.5 kV AC
- Power supply and input 500 V AC
Characteristic Trapezoidal
• Test voltage for 230 V AC between
Load w 750 Ω - Input and output 2.3 kV AC
Output response - Power supply and output 2.3 kV AC
- Power supply and input 2.3 kV AC
• Setting 4 to 20 mA/4 to 20 mA
- for short circuit at input 0 mA Certificates and approvals
- for open-circuit input 0 mA CENELEC According to DIN EN 50 014 and
• Signal limiting < 27 mA DIN EN 50 020
Intrinsically safe output circuit
Accuracy
• "Intrinsically safe" type of protection II (1) G EEx ia/ib IIB
(related to full-scale value of output
signal) - Maximum output voltage U0 19.74 V
- Maximum output current I0 87.1 mA
Linearity w 0.1% - Maximum output power P0 571 mW
Output signal ripple < 1% - Effective internal capacitance Ci Approx. 3 nF
Rise time T90 < 100 ms - Effective internal inductance Li Approx. 50 µH
- Internal resistance Ri 313 Ω
Influencing effect Related to full-scale value of output - Maximum voltage for safety Um 253 V
signal - Maximum external capacitance C0 Approx. 1.45 µF
• of ambient temperature w 0.1%/10 K - Maximum external inductance L0 Approx. 15 mH
• of change in load resistance w 0.1%/100% • "Intrinsically safe" type of protection II (1) G EEx ia/ib IIC
• of change in supply w 0.01%/15% - Maximum output voltage U0 19.74 V
- Maximum output current I0 87.1 mA
Rated operating conditions - Maximum output power P0 571 mW
Ambient conditions - Effective internal capacitance Ci Approx. 3 nF
• Ambient temperature
• Storage temperature
-20 to +65 °C
-40 to +85 °C
- Effective internal inductance Li
- Internal resistance Ri
- Maximum voltage for safety Um
Approx. 50 µH
313 Ω
253 V
6
• Functional temperature -25 to +70 °C - Maximum external capacitance C0 Approx. 230 nF
- Maximum external inductance L0 Approx. 4 mH
• Degree of protection to EN 60 529 IP 20
Conformity certificate TÜV 99 ATEX 1480
• Electromagnetic compatibility
- Interference immunity According to DIN EN 50 082-2 and External standards and
NAMUR NE21 guidelines
- Emitted interference According to DIN EN 50 081-2 Low-voltage guideline According to DIN EN 61 010
Design
Construction Compact plastic housing for rail
mounting
Weight Approx. 0.15 kg
Dimensions See page 6/10
Enclosure material PC/GV 25
Electrical connection Plug-in screw terminals, max
2.5 mm²
Power supply
Functional extra-low voltage DIN 57 100, VDE 0100 Part 410
• With safe isolation < 50 V AC, < 120 V DC
Universal current 24 V AC/DC 24 V AC ± 10%, 47 to 63 Hz
18 to 32 V DC
AC voltage 95 to 253 V AC, 47 to 63 Hz
Power consumption at rated voltage 24 V DC, < 1.4 W
24 V AC, < 2 VA
230 V AC, < 3.2 VA
Residual ripple within the specified
voltage limits (DC) UPP w 2.5 V

Siemens FI 01 · 2003 6/9


Supply units and input isolators
SITRANS I
Output isolator HART (FSK)

35 22,5 117,5

1 2 3 5 6
- + - +
1 23 4 5 6 (~) (~)
PWR PWR
1 NC 2

11 12
79

79

104
92

84
HK HK
- +

3
7 8 9 101112

104,5
AC 230V UC 24V

1 Power supply (PWR)


2 Input
3 Output
NC Not connected.

Fig. 6/10 Dimension drawing and connections

■ Ordering data Order No.


SITRANS I output isolator HART (FSK) } 7NG4130 - 1 7 A11
Rail-mounted,
input 4 to 20 mA,
intrinsically safe output 4 to 20 mA,
EEx ia/ib IIB/IIC
Power supply
• 24 V AC/DC (22.5 mm width) } 7NG4130 - 1 A
• 95 to 253 V AC (35 mm width) } 7NG4130 - 1 B
} Available ex stock.
6
7

6/10 Siemens FI 01 · 2003

You might also like