Absorption

column Design
 
Sulfur  dioxide  produced  by  combustion  of  sulphur  in  air  is  absorbed  in 
demineralized  water.  Pure  SO2  is  then  recovered  from  solution  by  steam 
stripping.  The  feed  is  4000kg/hr  of  gas  containing  10%  v/v  of  SO2.  Gas  will  be 
cooled at 20C. A 95 % recovery of SO2 is required. Design a suitable column for 
the above absorption.  
a) Material balance for the column 
b) Calculate the Height of the designed tower 
c) Diameter of the column 
d) Draw to schematic scale sectional elevation of the tower. 
Data: 

%  w/w  Solution  of  0.05  0.10 0.15 0.20 0.30 0.70 1.00  1.50
SO2 
Partial  Pressure  1.2  3.2 5.8 8.9 14.1 39 59  92
SO2 mm Hg 
 
Summary of the Absorption Column 
1. Height of the column: 5000 mm 
2. Diameter of the column: 1000 mm 
3. Absorption solvent: water 
4. Gas to be absorbed: SO2 
5. Feed flow rate: 4000kg/hr containing 10% v/v of SO2 
6. Packing Material: 3” Nominal size Ceramic Rasching Rings 
7. Type  of Packing: Random  
8. Liquid  Distribution:  Pipe  type  liquid  distributor  with  3.5  mm  dia  of 
holes and liquid pipe is 26 mm dia. 

       
(a) Raschig ring ; (b) Berl saddle ; (c) Pall ring ; (d) Intalox saddle. 
 

Dr. CANayak, BMSCE Page 1


 