Date: 17-07-19 Time: 1900 hrs

Description Tag No. Design (oC) Actual (oC)


Inlet Outlet ΔT Inlet Outlet ΔT
STG-01 Inspection of Inter/After Coolers CEH-1013 - - 15.8 39.5 48 8.5
STG-02 Inter/After Cooler Inspection CEH-2013 - - 15.8 39 44 5
STG-03 Gland Condenser Inspection CEH-3010 40 47 7 33.5 34 0.5
STG-03 HP oil Cooler Inspection CEH-3060 41.4 46.4 5 34
STG-04 Inter/After Cooler Inspection CEH-4013 - - 10 51.5 54 2.5
STG-04 HP oil Cooler Inspection CEH-4060 20 - 6.4 34 39 5
Closeloop heat exchanger "A" inspection CQH-1022A - - 10 31.1 33 1.9
Closeloop heat exchanger "S inspection CQH-1022S - - 10 31.1 33 1.9