INDICATION Cause Remedy

In clarification and purification In Purification In Clarification


Liquid flows out Bowl opens Bowl fails to Unsatisfactory Unsatisfactory No separation Outgoing oil Outgoing water Ejected sludge Unsatisfactory Oil discharge
through bowl unintentionally open for sludge ejection separation of oil and water contains water contains oil and water seperation through water
casing drain during operation ejection contains oil outlet
and/
or sludge
Gravity disc hole too large Use disc with smaller hole
Gravity disc hole too small Use disc with larger hole

Throughput too high Adjust


Back pressure too high Adjust
Wrong seperating temp Adjust
Bowl Hood seal ring Replace
defective
Sealing ring between upper Replace
and lower connecting pieces
in outlets is defective

Wrong level ring Purification : Small hole pitch


dia level ring
Clarification: large hole pitch
diam level ring
Bowl speed too I ow Make sure brake off, examine
motor and transmission

Sludge space in bowl is filled Clean

Bowl disc set is clogged Clean


Valves cosed Open and adjust to suitable
throughput
Dirty oil contains water Assemble and operate
machine as a purifier
Bowl incorrectly assembled

Ejection in progress Normal


Operating tank water placed See installation drg
too high
Operating tank water placed See installation drg
too high
Seal ring in control paring Exchange
disc device defective

Seal ring in operating slide Replace


defective
Valve plug defective Replace
Seal ring in sliding bowl Replace
defective
Seal ring in gravity disc Replace
defective
Operating water strainer Clean
clogged