Professional Documents
Culture Documents
MANUAL
Address: _________________________________________________________________
Phone: __________________________________________________________________
Service: __________________________________________________________________
Parts: ___________________________________________________________________
Phase__________________________________
Note: Continuing research results in steady improvements; therefore, information in this manual is subject
to change without notice.
Only instructions originating from the factory or its authorized translation representative(s) are considered to
be the original set of instructions.
Taylor Company
750 N. Blackhawk Blvd.
Rockton, IL 61072
Table of Contents
028754-M i
MIX Button..........................................................................................................5-2
STANDBY Button ...............................................................................................5-2
WASH Button .....................................................................................................5-2
AUTO Button ......................................................................................................5-3
RESET Button ....................................................................................................5-3
Air Tube..............................................................................................................5-3
Adjustable Draw Handle.....................................................................................5-4
Section 6: Operating Procedures
Prior to Setup (Model 774) .................................................................................6-1
Assembly............................................................................................................6-1
Sanitizing............................................................................................................6-7
Priming ...............................................................................................................6-9
Closing Procedure............................................................................................6-10
Draining Product from the Freezing Cylinder ...................................................6-10
Rinsing .............................................................................................................6-11
Cleaning ...........................................................................................................6-11
Disassembly .....................................................................................................6-11
Manual Brush Cleaning ....................................................................................6-11
Section 7: Operator’s Checklist
During Cleaning and Sanitizing ..........................................................................7-1
Troubleshooting Bacterial Count ........................................................................7-1
Regular Maintenance Checks ............................................................................7-1
Winter Storage ...................................................................................................7-2
Section 8: Troubleshooting Guide
Section 9: Parts Replacement Schedule
Maintenance Intervals ........................................................................................9-1
Section 10: Limited Warranty on Equipment
Section 11: Limited Warranty on Parts
ii 028754-M
Section 1: To the Installer
To the Installer Models 750, 751, 754, 774, 791, and 794 1-1
TO THE INSTALLER
Water Connections Each unit requires one power supply for each data label
on the unit. Check the data label(s) on the freezer for
(Water-Cooled Units Only)
branch circuit overcurrent protection or fuse, circuit
An adequate cold water supply must be provided with a
ampacity, and other electrical specifications. Refer to the
hand shutoff valve. On the underside rear of the base
wiring diagram provided inside the electrical box for
pan, two 3/8 in. IPS (for single-head units) or two 1/2 in.
proper power connections.
IPS (for double-head units) water connections for inlet
1 and outlet have been provided for easy hookup. 1/2 in.
inside diameter water lines should be connected to the
machine. (Flexible lines are recommended, if local codes CAUTION: THIS EQUIPMENT MUST BE
permit.) Depending on local water conditions, it may be PROPERLY GROUNDED! FAILURE TO DO SO CAN
advisable to install a water strainer to prevent foreign RESULT IN SEVERE PERSONAL INJURY FROM
substances from clogging the automatic water valve. ELECTRICAL SHOCK!
There will be only one water-in and one water-out
connection for both single-head and double-head units.
Do not install a hand shutoff valve on the water “out” line!
Water should always flow in this order: first, through the DO NOT operate this freezer with larger fuses
automatic water valve; second, through the condenser; than specified on the unit data label. Failure to follow this
and third, through the outlet fitting to an open trap drain. instruction may result in electrocution or damage to the
machine.
1-2 Models 750, 751, 754, 774, 791, and 794 To the Installer
TO THE INSTALLER
Refrigerant
To the Installer Models 750, 751, 754, 774, 791, and 794 1-3
TO THE INSTALLER
Notes:
1-4 Models 750, 751, 754, 774, 791, and 794 To the Installer
Section 2: To the Operator
To the Operator Models 750, 751, 754, 774, 791, and 794 2-1
TO THE OPERATOR
2-2 Models 750, 751, 754, 774, 791, and 794 To the Operator
Section 3: Safety
!
or not used for long periods, or during initial
installation, shall have protective devices such
This appliance is to be used only by trained
as a GFI, to protect against the leakage of cur-
personnel. It is not intended for use by children or people
rent, installed by the authorized personnel to the
with reduced physical, sensory, or mental capabilities, or
local codes.
lack of experience and knowledge, unless given
• Supply cords used with this unit shall be oil-
supervision or instruction concerning the use of the
resistant, sheathed flexible cable not lighter
appliance by a person responsible for their safety.
than ordinary polychloroprene or other equiva-
lent synthetic elastomer-sheathed cord (Code
designation 60245 IEC 57) installed with the
This unit is provided with an equipotential proper cord anchorage to relieve conductors
grounding lug that is to be properly attached to the rear of from strain, including twisting, at the terminals
the frame by the authorized installer. The installation and protect the insulation of the conductors
location is marked by the equipotential bonding symbol from abrasion.
(5021 of IEC 60417- 1) on the removable panel and the • If the supply cord is damaged, it must be
frame. replaced by the manufacturer, its service agent,
or similarly qualified person, in order to avoid a
hazard.
Failure to follow these instructions may result in
DO NOT use a water jet to clean or rinse the
electrocution. Contact your local authorized Taylor
freezer. Failure to follow these instructions may result in
distributor for service.
serious electrical shock.
Safety Models 750, 751, 754, 774, 791, and 794 3-1
SAFETY
3-2 Models 750, 751, 754, 774, 791, and 794 Safety
Section 4: Operator Parts Identification
Model 750
17
16
1 3
15
12 2
4
13
5
10
7 4
14
6
11
Figure 4-1
Operator Parts Identification Models 750, 751, 754, 774, 791, and 794 4-1
OPERATOR PARTS IDENTIFICATION
Model 751
17
16
1 3
15
2
18
4
19 18
13
5
6
10
4 14
7
8
4
20
9
21 12
11
Figure 4-2
4-2 Models 750, 751, 754, 774, 791, and 794 Operator Parts Identification
OPERATOR PARTS IDENTIFICATION
Model 754
1
17
2 16
18
3
15
11
4
12
19
14
13
5
4
6
8
20
7
10
9
Figure 4-3
Operator Parts Identification Models 750, 751, 754, 774, 791, and 794 4-3
OPERATOR PARTS IDENTIFICATION
Model 774
1 23
2 22
12
3
11 15
24
4
19
18 5
6
13
4
16 17
21
14
25
8
20
9 7 10
Figure 4-4
4-4 Models 750, 751, 754, 774, 791, and 794 Operator Parts Identification
OPERATOR PARTS IDENTIFICATION
1 Knob–Plunger–Tan 032762–TAN
1 Knob–Plunger–Brown 032762–BRN
1 Knob–Plunger–Red 032762–RED
1
2 2 O–Ring–9/16 OD x .103 W 016369
3 3 Nut–Plunger 036577
6 Insert–Plunger 032758
5
7 Spring–Plunger 032761
8 Washer–Nylon 032760
6
9 Plunger 036578
9 13 Lid–Pump 036822
14 Tube–Discharge 050912
10
10a 15 O–Ring–1–5/16 OD x .103 W 048149
Includes:
13 1 – Body A.–Pump Valve
1 – Brush–Cleaning (054068)
1 – Instruction Sheet–Installation/Cleaning
11
14
15
16
17
Figure 4-5
Operator Parts Identification Models 750, 751, 754, 774, 791, and 794 4-5
OPERATOR PARTS IDENTIFICATION
Model 791
5
3
2 6
4
3
11 10
7
8
9
Figure 4-6
4-6 Models 750, 751, 754, 774, 791, and 794 Operator Parts Identification
OPERATOR PARTS IDENTIFICATION
Model 794
1
16
14
3
5
15 4
13
17
6
4
11
8
10
2
12
7
9
Figure 4-7
Operator Parts Identification Models 750, 751, 754, 774, 791, and 794 4-7
OPERATOR PARTS IDENTIFICATION
16
15
13
1
1a 3 8
9
12
1b 14
4 1c
7 11
10
2
4
Figure 4-8
4-8 Models 750, 751, 754, 774, 791, and 794 Operator Parts Identification
OPERATOR PARTS IDENTIFICATION
Models 754, 774 and 794 Three-Spout Door and Beater Assembly
8
8a
18
6
17
7
8c
8b
1a
12 15
9
11
14 16 4
13
10
3
1
2
4
5
Figure 4-9
Operator Parts Identification Models 750, 751, 754, 774, 791, and 794 4-9
OPERATOR PARTS IDENTIFICATION
2
18
1a
1b 11 17
12
3 10a
4 4 15
14 16
5
6 10 13
9
7
8
Figure 4-10
4-10 Models 750, 751, 754, 774, 791, and 794 Operator Parts Identification
OPERATOR PARTS IDENTIFICATION
Accessories
2
8
3 4
10
Figure 4-11
Operator Parts Identification Models 750, 751, 754, 774, 791, and 794 4-11
OPERATOR PARTS IDENTIFICATION
Notes:
4-12 Models 750, 751, 754, 774, 791, and 794 Operator Parts Identification
Section 5: User Interface
750/751
2 3 4 5
7
Figure 5-1
754/774/791/794
1 1
5
2
3 4 5 3 4 5
Figure 5-2
Item Description
1 MIX LOW Indicator Light
2 MIX Refrigeration Button
3 STANDBY Button
4 WASH Button
5 AUTO Button
6 Power On/Off (Toggle Switch)
7 RESET Button
Note: Legend for figures 5-1 and 5-2.
User Interface Models 750, 751, 754, 774, 791, and 794 5-1
USER INTERFACE
5-2 Models 750, 751, 754, 774, 791, and 794 User Interface
USER INTERFACE
RESET Button
On counter models, the RESET button is located on the
side of the unit. On console models, the RESET button is
located in the service panel. The reset protects the
Figure 5-3
beater motor from an overload condition. If an overload
occurs, the reset mechanism will trip. To properly reset 1. After priming the machine, lubricate the O-rings on
the freezer, press the AUTO button to cancel the cycle. the air tube (the end with the hole) and place it into
Turn the power switch to the OFF position. Press the the mix inlet hole. Every time the draw handle is
RESET button firmly. raised, new mix and air from the hopper will flow
down into the freezing cylinder. This will keep the
freezing cylinder properly loaded and will maintain 5
overrun.
WARNING: DO NOT use metal objects to 2. During long “no sale” periods, remove the air orifice.
press the RESET button. Failure to comply may Lubricate the O-rings on the air tube (the end
result in severe personal injury or death. without the hole), and place it into the mix inlet hole.
Turn the power switch to the ON position. Press the This will prevent any mix from entering the freezing
WASH button and observe the freezer's performance. cylinder.
Open the side access panel. Make sure the beater motor Important! Make sure the level of mix in the hopper
is turning the drive shaft in a clockwise direction (from the is below the mix delivery hole in the feed tube.
operator end) without binding. Failure to follow this instruction may result in lower
If the beater motor is turning properly, press the WASH product quality when normal operation is resumed.
button to cancel the cycle. Press the AUTO button to The air orifice is used to meter a certain amount of air
resume normal operation. If the freezer shuts down into the freezing cylinder. The air orifice maintains
again, contact a service technician. (For Models 754, overrun and allows enough mix to enter the freezing
774, 791, and 794, press the AUTO button on both sides cylinder after a draw.
of the unit to resume normal operation.)
User Interface Models 750, 751, 754, 774, 791, and 794 5-3
USER INTERFACE
Figure 5-4
Note: Once the draw rate is set, tighten the lock nut with
a wrench.
5-4 Models 750, 751, 754, 774, 791, and 794 User Interface
Section 6: Operating Procedures
Model 751 has been selected to illustrate the step-by- Use warm water and follow the manufacturer's
step operating procedures for all models contained in this specifications. Sanitize the topping pumps by
manual. These models, for all practical purposes of placing the entire pump assembly in the pail of
operation, are the same. sanitizing solution. Pump the solution through the
Each unit stores mix in a hopper. The mix then flows by assembly to thoroughly sanitize the pump.
gravity through an air tube down into the freezing 4. Remove the two topping pumps. Fill each stainless
cylinder. They all have 3.4 qt. (3.2 L) capacity freezing steel syrup jar with topping. Replace the topping
cylinders. Models 750, 751, 754, and 774 have 20 qt. pumps in the syrup jars.
(18.9 L) mix hoppers. Models 791 and 794 have 14 qt.
(13.2 L) mix hoppers. Assembly
Duplicate the following procedures where they apply for Note: When lubricating parts, use an approved food
the second freezing cylinder on Models 754, 774, 791, grade lubricant (example: Taylor Lube).
and 794.
We begin our instructions at the point where we enter the
store in the morning and find the parts disassembled and
MAKE SURE THE POWER SWITCH IS IN
laid out to air dry from the previous night's cleaning.
THE “OFF” POSITION! Failure to follow this instruction
These opening procedures will show you how to may result in severe personal injury to fingers or hands
assemble these parts into the freezer, sanitize them, and from hazardous moving parts.
prime the freezer with fresh mix in preparation to serve
your first portion.
1. Lubricate the groove and shaft portion that comes in
If you are disassembling the machine for the first time or
contact with the bearing on the beater drive shaft.
need information to get to this starting point in our
Slide the seal over the shaft and groove until it snaps
instructions, turn to page 6-11, “Disassembly,” and start
there.
into place. Do not lubricate the hex end of the drive 6
shaft. Fill the inside portion of the seal with 1/4 in.
more lubricant and lubricate the flat side of the seal
Prior to Setup (Model 774) that fits onto the rear shell bearing.
1. Remove the two stainless steel syrup jars with
topping pumps from the syrup rail. Check the water
level in the heated syrup topping well. Make sure the
water is filled to the indicating mark on the bottom of
the well. The heated rail should have 32 oz. (946.2
mL) of water.
2. Place the heater switch in the ON position.
Note: This heating process will take approximately
2.5 hours to reach temperature. The water level in
the topping wells must be checked at least once
daily.
3. Prepare a pail of an approved 100 PPM sanitizing
solution (examples: 2.5 gal. [9.5 L] of Kay-5®or 2 gal.
[7.6 L] of Stera-Sheen®). Figure 6-1
Operating Procedures Models 750, 751, 754, 774, 791, and 794 6-1
OPERATING PROCEDURES
Figure 6-4
5. Slide the beater the remainder of the way into the
freezing cylinder and over the end of the drive shaft.
The beater should fit snugly, but not so tightly that the
beater cannot be turned slightly to engage the drive
Figure 6-2 shaft. If the beater slides in too easily with little or no
3. Take one of the scraper blades and slip it under the resistance, there will not be enough force against the
hook at the front of the beater. Wrap the blade beater to hold the blades in place. If this is the case,
around the beater, following the helix and pushing contact your authorized Taylor service technician.
the blade down onto the helix as you wrap. At the 6. Repeat step 1 through step for the other side of
back end of the beater, slip the blade under the hook. the freezer on Models 754, 774, 791, and 794.
Repeat this step for the second scraper blade.
Figure 6-3
4. Holding the beater securely, slide the beater one third
of the way into the freezing cylinder. Looking into the
freezing cylinder, align the hole at the rear of the
beater with the flats on the end of the drive shaft.
6-2 Models 750, 751, 754, 774, 791, and 794 Operating Procedures
OPERATING PROCEDURES
7. Place the large rubber gasket(s) into the groove(s) on 8. Slide the two O-rings into the grooves on the prime
the back side of the freezer door. plug(s). Apply an even coat of Taylor Lube to the O-
Slide the white plastic front bearing(s) over the baffle rings and shaft(s).
rod(s) onto the bearing hub(s), making sure that the
flanged end of the bearing is resting against the
freezer door.
Note: Do not lubricate the gasket(s) or the front
bearing(s).
Figure 6-7
Note: There are two prime plugs for the Models 754,
774, 791, and 794 door, one for each freezing
cylinder.
Figure 6-5 9. Insert the prime plug(s) into the hole(s) in the top of
the freezer door, and push down.
Note: There are two gaskets and two front bearings for
the Models 754, 774, 791, and 794 door, one for each
freezing cylinder.
Figure 6-8
Figure 6-6
Operating Procedures Models 750, 751, 754, 774, 791, and 794 6-3
OPERATING PROCEDURES
Note: On Models 754, 774, 791, and 794, the short Note: Models 754, 774, 791, and 794 have three draw
handscrews go on the bottom, and the long handscrews valves.
go on the top. 12. Lubricate the inside of the freezer door spout(s), top
10. Insert the baffle rod(s) through the opening in the and bottom, and insert the draw valve(s) from the
beater(s) and seat the door flush with the freezing bottom until the slot in the draw valve(s) comes into
cylinder. With the door seated on the freezer studs, view.
install the handscrews. Tighten equally in a
crisscross pattern to ensure the door is snug.
Figure 6-11
13. Install the adjustable draw handle(s). Slide the O-ring
Figure 6-9 into the groove on the pivot pin, and lubricate.
11. Install the draw valve(s). Slide the two O-rings into
the grooves on the draw valve(s) and lubricate.
Figure 6-12
Figure 6-10
6-4 Models 750, 751, 754, 774, 791, and 794 Operating Procedures
OPERATING PROCEDURES
Note: Models 754, 774, 791, and 794 have three draw 15. Snap the design cap(s) over the end of the door
handles. Slide the fork of the draw handle in the slot of spout(s).
the draw valve, starting from the right. Slide the pivot pin
through each draw handle as you insert them into the
draw valves.
14. Slide the fork over the bar in the slot of the draw
valve. Secure with the pivot pin.
Figure 6-14
16. Install the front drip tray and the splash shield under
the door spout(s).
Figure 6-13
Note: These units feature adjustable draw handles to
provide the best portion control. The draw handles can
be adjusted for different flow rates. See "Adjustable Draw
Handle" on page 5-4 for more information on adjusting
these handles.
6
Figure 6-15
Operating Procedures Models 750, 751, 754, 774, 791, and 794 6-5
OPERATING PROCEDURES
17. Slide the rear drip pan(s) into the hole in the side 20. Slide the small O-ring into the groove of the air
panel. orifice. Do not lubricate the O-ring.
Figure 6-17
Figure 6-19
22. Lay the air tube (with the air orifice installed) and the
hopper gasket in the bottom of the mix hopper for
sanitizing.
Note: Models 754 and 774 have one hopper gasket
for each mix hopper. Models 791 and 794 do not
require a hopper gasket.
Repeat step 19 through step 22 for the other side
of the freezer on Models 754, 774, 791, and 794.
6-6 Models 750, 751, 754, 774, 791, and 794 Operating Procedures
OPERATING PROCEDURES
!
brush clean the mix hopper. When cleaning the
hopper, take particular care in brushing the mix level
CAUTION: DO NOT run the machine without
sensing probe on the rear wall of the hopper, the mix
product. Failure to follow this instruction can result in
inlet hole, the air tube, and the hopper gasket.
damage to the machine.
Sanitizing
Note: Use warm water and follow the manufacturer's
specifications.
1. Prepare an approved 100 PPM sanitizing solution
(examples: 2.5 gal. [9.5 L] of Kay-5®or 2 gal.
[7.6 L] of Stera-Sheen®).
2. Pour the sanitizing solution into the hopper and allow
it to flow into the freezing cylinder.
Figure 6-21
Figure 6-20
Figure 6-22
Operating Procedures Models 750, 751, 754, 774, 791, and 794 6-7
OPERATING PROCEDURES
Figure 6-23
4. Place the power switch in the ON position.
Figure 6-25
6. Place an empty pail beneath the door spout and raise
the prime plug.
6
Figure 6-24
Figure 6-26
6-8 Models 750, 751, 754, 774, 791, and 794 Operating Procedures
OPERATING PROCEDURES
7. When a steady stream of sanitizing solution is 9. Assemble the hopper gasket around the top edge of
flowing from the prime plug opening in the bottom of the mix hopper. Stand the air tube in the corner of the
the freezer door, lower the draw handle. Draw off all hopper.
the sanitizing solution.
Figure 6-28
Figure 6-27 10. Repeat Step 1 through Step 9 for the other side of
Note: On Models 754, 774, 791, and 794, the freezer on Models 754, 774, 791, and 794.
momentarily pull the center draw handle down to
sanitize the center door spout. Priming
8. Once the sanitizer stops flowing from the door spout, 1. With a pail beneath the door spout, lower the draw
raise the draw handle and press the WASH button, handle. Make sure the prime plug is still in the UP
canceling the beater motor operation. position. Pour 2 gal. (7.6 L) of fresh mix into the mix
Note: You have just sanitized the freezer. Make hopper and allow it to flow into the freezing cylinder.
sure your hands are sanitized before continuing
these instructions.
This will force out any remaining sanitizing solution.
When mix is flowing full strength from the door spout,
6
raise the draw handle.
Note: Use only fresh mix when priming the freezing
cylinder.
Figure 6-29
Operating Procedures Models 750, 751, 754, 774, 791, and 794 6-9
OPERATING PROCEDURES
2. Once a steady stream of mix starts to flow from the 6. Fill the hopper with mix. As the mix level comes in
prime plug opening in the bottom of the freezer door, contact with the mix level sensing probe on the rear
push down the prime plug. wall of the hopper, the MIX LOW light will shut off.
7. Place the mix hopper cover in position over the mix
hopper.
8. Repeat step 1 through step 7 for the other side of
the freezer on Models 754, 774, 791, and 794.
Closing Procedure
To disassemble your unit, the following items will be
needed:
• Two cleaning pails
• Sanitized stainless steel rerun can with lid
• Necessary brushes (provided with freezer)
• Cleaner
Figure 6-30 • Single-service towels
3. Lubricate the O-rings on the air tube on the end with
the small hole on the side. Draining Product from the Freezing
4. Install the air tube (the end with the hole) with the air Cylinder
orifice installed into the mix inlet hole in the mix 1. Press the AUTO button, canceling compressor and
hopper. beater motor operation.
5. Press the AUTO button. The AUTO light will come Press the MIX refrigeration button, canceling the mix
on, indicating the main refrigeration system is hopper refrigeration system.
operating. When the unit cycles off, the product will 2. Remove the hopper cover, hopper gasket, and air
6 be at serving viscosity. tube. Take these parts to the sink for cleaning.
Note: On Models 751, 754, 774, 791, and 794, the 3. If local health codes permit the use of rerun, place
MIX light will come on, indicating the mix a sanitized, NSF-approved stainless steel rerun
refrigeration system is operating to maintain the mix container beneath the door spout. Press the WASH
in the mix hopper. button and lower the draw handle. Drain the
remaining product from the freezing cylinder and mix
hopper. When the flow of product stops, press the
WASH button and raise the draw handle. Place the
sanitized lid on the rerun container and place it in the
walk-in cooler.
Note: If local health codes do not permit the use
of rerun, the product must be discarded. Drain the
product into a pail and properly discard it.
4. Repeat step 1 through step 3 for the other side of
the freezer on Models 754, 774, 791, and 794.
Figure 6-31
! ALWAYS FOLLOW LOCAL HEALTH CODES.
6-10 Models 750, 751, 754, 774, 791, and 794 Operating Procedures
OPERATING PROCEDURES
Rinsing Disassembly
1. Pour 2 gal. (7.6 L) of cool clean water into the mix
hopper. With the brushes provided, scrub the mix
hopper, mix inlet hole and mix level sensing probe.
MAKE SURE THE POWER SWITCH IS IN
2. With a pail beneath the door spout, raise the prime THE “OFF” POSITION! Failure to follow this instruction
plug and press the WASH button. may result in severe personal injury to fingers or hands
3. When a steady stream of rinse water is flowing from from hazardous moving parts.
the prime plug opening in the bottom of the freezer
door, lower the draw handle. Drain all the rinse water
1. Remove the handscrews, freezer door(s), beater(s),
from the freezing cylinder, raise the draw handle and
scraper blades, and drive shaft(s) from the freezing
press the WASH button cancelling the WASH mode.
cylinder(s). Take these parts to the sink for cleaning.
4. Repeat step 1 through step 3 for the other side of
2. Remove the front drip tray and the splash shield.
the freezer on models 754, 774, 791, and 794.
Operating Procedures Models 750, 751, 754, 774, 791, and 794 6-11
OPERATING PROCEDURES
6-12 Models 750, 751, 754, 774, 791, and 794 Operating Procedures
Section 7: Operator’s Checklist
During Cleaning and Sanitizing On a designated day of the week, run the mix as
low as feasible and discard it after closing. This
Important! Cleaning and sanitizing schedules are gov-
will break the rerun cycle and reduce the
erned by federal, state, or local regulatory agencies, and
possibility of high bacteria and coliform counts.
must be followed accordingly. If the unit has a Standby
mode, it must not be used in lieu of proper cleaning and Properly prepare the cleaning and sanitizing
sanitizing procedures and frequencies set forth by the solutions. Read and follow label directions
ruling health authority. The following checkpoints should carefully. Too strong of a solution may damage the
be stressed during the cleaning and sanitizing opera- parts, and too weak of a solution will not do an
tions. adequate job of cleaning or sanitizing.
The temperature of the mix in the mix hopper and
!
walk-in cooler should be below 40°F (4.4°C).
Operator’s Checklist Models 750, 751, 754, 774, 791, and 794 7-1
OPERATOR’S CHECKLIST
Winter Storage
If your machine is equipped with an auxiliary If the place of business is to be closed during the winter
refrigeration system, check the auxiliary months, it is important to protect the freezer by following
condenser for accumulation of dirt and lint. Dirty certain precautions, particularly if the building is subject
condensers will reduce the refrigeration capacity to freezing conditions.
of the mix hopper. Condensers must be cleaned • Disconnect the freezer from the main power source
monthly with a soft brush. Never use to prevent possible electrical damage.
screwdrivers or other metal probes to clean • On water-cooled freezers, disconnect the water
between the fins. Failure to follow this instruction supply. Relieve pressure on the spring in the water
may result in electrocution. valve. Use air pressure on the outlet side to blow out
any water remaining in the condenser. This is
extremely important. Failure to follow this
procedure may cause severe and costly damage to
CAUTION: Always disconnect electrical
the refrigeration system.
power prior to cleaning the condenser. Failure to
• Your local Taylor distributor can perform this winter
follow this instruction may result in electrocution.
storage service for you.
• Wrap detachable parts of the freezer such as beater,
If your machine is water cooled, check the water blades, drive shaft, and freezer door, and place them
lines for kinks or leaks. Kinks can occur when the in a protected dry place. Rubber trim parts and
machine is moved back and forth for cleaning or gaskets can be protected by wrapping them with
maintenance purposes. Deteriorated or cracked moisture-proof paper. All parts should be thoroughly
water lines should be replaced only by an cleaned of dried mix or lubrication, which attract mice
authorized Taylor distributor. and other vermin.
7-2 Models 750, 751, 754, 774, 791, and 794 Operator’s Checklist
Section 8: Troubleshooting Guide
Table 8-1
Page
Problem Probable Cause Remedy
Ref.
1. No product is being dis- a. Freeze–up in mix inlet hole. a. Call service technician to adjust the —
pensed with draw valve mix hopper temperature.
open and the machine in
b. Beater motor out on reset. b. Reset the freezer. 5-3
the Auto mode.
c. The beater is rotating counterclock- c. Contact service technician to correct —
wise from the operator end. rotation to clockwise from operator
end.
d. The circuit breaker is off, or the fuse d. Turn the breaker on, or replace the —
is blown. fuse.
e. There is inadequate mix in the mix e. Fill the mix hopper with mix. 6-9
hopper.
f. The air orifice is not installed. f. Install air orifice in air tube. 6-9
2. The product is too stiff. a. The viscosity needs adjustment. a. Contact service technician. —
b. The air orifice is not installed. b. Install air orifice in air tube. 6-9
3. The product is too soft. a. Viscosity needs adjustment. a. Contact service technician. —
b. Not enough air space around unit. b. Allow for adequate air flow across 3-2
(air-cooled units) the condenser.
f. Loss of water (W/C). f. Locate cause of water loss and cor- 7-2
rect.
4. The mix in the mix hopper is a. The temperature is out of adjustment. a. Call service technician to adjust the —
too cold. mix hopper temperature.
d. The mix hopper cover is not in posi- d. Place the cover in position. 6-10
tion.
e. The MIX light is not lit. e. Press the MIX button. 5-2
6. The drive shaft is stuck in a. Rounded corners of drive shaft, cou- a. Call service technician to correct —
the drive coupling. pling, or both. cause and replace the necessary
components. Do not lubricate the
hex end of the drive shaft.
b. Mix and lubricant collected in the b. Brush clean the rear shell bearing 6-12
drive coupling. area regularly.
Troubleshooting Guide Models 750, 751, 754, 774, 791, and 794 8-1
TROUBLESHOOTING GUIDE
Page
Problem Probable Cause Remedy
Ref.
7. The freezing cylinder walls a. The beater assembly is bent. a. Call service technician to repair or —
are scored. replace the beater and to correct the
cause of insufficient mix in the freez-
ing cylinder.
b. The front bearing is missing or worn b. Install or replace the front bearing. 6-2
on the freezer door.
8. Excessive mix leakage into a. Missing or worn drive shaft seal on a. Install or replace regularly. 6-1/9-1
the rear drip pan. drive shaft.
9. Excessive mix leakage from a. Missing or worn draw valve O-rings. a. Install or replace regularly. 6-4/9-1
door spout.
b. Inadequate lubrication of draw valve b. Lubricate properly. 6-4
O-rings.
c. Wrong type of lubricant is being used c. Use the proper lubricant (example: 6-1
(example: petroleum base lubricant). Taylor Lube).
10.No freezer operation after a. Unit is unplugged. a. Plug into wall receptacle. —
pressing the AUTO button.
b. The circuit breaker is off, or the fuse b. Turn the breaker on, or replace the —
is blown. fuse.
11.Product is not feeding into a. Inadequate level of mix in the mix a. Fill the mix hopper with mix. 6-9
the freezing cylinder. hopper.
b. The mix inlet hole is frozen up. b. The mix hopper temperature needs —
adjustment. Call service technician.
c. The air tube is installed incorrectly. c. Install the air tube in the mix inlet 6-10
hole, using the end with the small
hole in the side.
d. The air orifice is not installed. d. Install the air orifice in the air tube. 6-10
8-2 Models 750, 751, 754, 774, 791, and 794 Troubleshooting Guide
Section 9: Parts Replacement Schedule
Maintenance Intervals
Table 9-1
Scraper Blade X
Front Bearing X
Parts Replacement Schedule Models 750, 751, 754, 774, 791, and 794 9-1
PARTS REPLACEMENT SCHEDULE
Notes:
9-2 Models 750, 751, 754, 774, 791, and 794 Parts Replacement Schedule
Section 10: Limited Warranty on Equipment
Batch Desserts Printed circuit boards and Soft- Two (2) years
ech™ controls beginning with
serial number H8024200
Limited Warranty on Equipment Models 750, 751, 754, 774, 791, and 794 10-1
LIMITED WARRANTY ON EQUIPMENT
10
10-2 Models 750, 751, 754, 774, 791, and 794 Limited Warranty on Equipment
LIMITED WARRANTY ON EQUIPMENT
LIMITATION OF WARRANTY
THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS AND/
OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER'S SOLE REMEDY
WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE COMPONENTS
UNDER THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL OR INCIDENTAL
DAMAGES (INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS, PROPERTY DAMAGES
OR SERVICE EXPENSES ARE EXPRESSLY EXCLUDED. THE EXPRESS WARRANTIES MADE IN THIS LIMITED
WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER
PERSON, WHATSOEVER.
LEGAL REMEDIES
The owner must notify Taylor in writing by certified or registered letter to the following address of any defect or
complaint with the Product, stating the defect or complaint and a specific request for repair, replacement, or other
correction of the Product under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
Taylor Company
750 N. Blackhawk Blvd.
Rockton, IL 61072, U.S.A.
10
Limited Warranty on Equipment Models 750, 751, 754, 774, 791, and 794 10-3
LIMITED WARRANTY ON EQUIPMENT
Notes:
10
10-4 Models 750, 751, 754, 774, 791, and 794 Limited Warranty on Equipment
Section 11: Limited Warranty on Parts
1, 2
Except that Taylor Part #032129SER2 (Compressor-Air-230V SERV) and Taylor Part #075506SER1
(Compressor-Air-115V 60HZ) shall have a limited warranty period of twelve (12) months when used in Taylor freezer
equipment and a limited warranty period of two (2) years when used in Taylor grill equipment.
11
Limited Warranty on Parts Models 750, 751, 754, 774, 791, and 794 11-1
LIMITED WARRANTY ON PARTS
11
11-2 Models 750, 751, 754, 774, 791, and 794 Limited Warranty on Parts
LIMITED WARRANTY ON PARTS
LIMITATION OF WARRANTY
THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS AND/
OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER'S SOLE REMEDY
WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS UNDER
THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL OR INCIDENTAL DAMAGES
(INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS, PROPERTY DAMAGES OR
SERVICE EXPENSES ARE EXPRESSLY EXCLUDED. THE EXPRESS WARRANTIES MADE IN THIS LIMITED
WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER
PERSON, WHATSOEVER.
LEGAL REMEDIES
The owner must notify Taylor in writing by certified or registered letter to the following address of any defect or
complaint with the Part, stating the defect or complaint and a specific request for repair, replacement, or other
correction of the Part under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
Taylor Company
750 N. Blackhawk Blvd.
Rockton, IL 61072, U.S.A.
11
Limited Warranty on Parts Models 750, 751, 754, 774, 791, and 794 11-3
LIMITED WARRANTY ON PARTS
Notes:
11
11-4 Models 750, 751, 754, 774, 791, and 794 Limited Warranty on Parts