G3520C Generator Set GZM00001-UP(SEBP3869 - 20) - Document Structure Página 1 de 2

Shutdown SIS

Previous Screen

Product: GENERATOR SET


Model: G3520C GENERATOR SET GZM
Configuration: G3520C Generator Set GZM00001-UP

Testing and Adjusting


Caterpillar Digital Voltage Regulator (CDVR)
Media Number -RENR7941-06 Publication Date -07/01/2010 Date Updated -07/07/2010

i03470083

Service Tools
SMCS - 0785

Illustration 1 g01425366

The Cat Digital Voltage Regulator presents an electrical


shock/electrocution hazard. This hazard will cause serious injury or
death.

Service by trained personnel only.

The terminals and heat sinks are live at hazardous voltages when power
is applied and for up to 8 minutes after power is removed.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 01/08/2010
G3520C Generator Set GZM00001-UP(SEBP3869 - 20) - Document Structure Página 2 de 2

Illustration 2 g00241203
6V-7070 Caterpillar Digital Multimeter

Caterpillar digital multimeters can be used in order to measure voltage, resistance or current up to 10
amperes. Rectifiers can also be checked by using the diode function. See Special Instruction,
SEHS7734, "Use Of The 6V-7070 And 6V-7800 Multimeter" for the correct operation of the 6V-
7070 Digital Multimeter.

Illustration 3 g00538441
8T-0900 AC/DC Clamp-On Ammeter

The 8T-0900 Ammeter may be used to measure current up to 1200 amperes. When you are
measuring line current on multiple lead units, measure the current in each conductor per phase and
add the currents together. See Special Instruction, SEHS8420, "Using the 8T900 AC/DC Clamp On
Ammeter 0651" for the correct operation of the 8T-0900 Ammeter.

Copyright 1993 - 2010 Caterpillar Inc. Sun Aug 1 20:10:05 UTC-0300 2010
All Rights Reserved.
Private Network For SIS Licensees.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 01/08/2010