You are on page 1of 14

19/02/2017 G3516H 

Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

Previous Screen
Welcome: uhyxel
Product:  GENERATOR SET
Model:  G3516H GENERATOR SET GLN
Configuration: G3516H Generator Set GLN00001­UP

Troubleshooting 
G3516H and G3520H Generator Set Engines
Media Number ­UENR0515­05 Publication Date ­01/11/2014 Date Updated ­04/04/2016

   
i05949397

Exhaust Temperature ­ Test
SMCS ­ 1088­038­TA ; 7498­038

Use this procedure if one of the diagnostic codes in Table 1 or Table 2 is active or easily repeated.

Table 1
Diagnostic Codes Table 

System
Description  Conditions which Generate this Code 
Response 
1180­3 
Engine Turbocharger 1 Turbine Inlet The code is
Temperature : Voltage Above The ECM has detected a voltage in the circuit for logged. 
Normal the exhaust temperature sensor that is above The alarm
normal.  output is
NOTE: Turbocharger 1 is the right activated.  
side turbocharger. 
1180­4 
Engine Turbocharger 1 Turbine Inlet The code is
Temperature : Voltage Below The ECM has detected a voltage in the circuit for logged. 
Normal the exhaust temperature sensor that is below The alarm
normal.  output is
NOTE: Turbocharger 1 is the right activated.  
side turbocharger. 

1181­3 
Engine Turbocharger 2 Turbine Inlet The code is
Temperature : Voltage Above The ECM has detected a voltage in the circuit for logged. 
Normal the exhaust temperature sensor that is above The alarm
normal.  output is
NOTE: Turbocharger 2 is the left activated.  
side turbocharger. 
1181­4  The ECM has detected a voltage in the circuit for The code is
Engine Turbocharger 2 Turbine Inlet the exhaust temperature sensor that is below logged. 
Temperature : Voltage Below normal.  The alarm
Normal output is
activated.  

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sis… 1/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

NOTE: Turbocharger 2 is the left
side turbocharger. 

1184­3 
Engine Turbocharger 1 Turbine The code is
Outlet Temperature : Voltage Above The ECM has detected a voltage in the circuit for logged. 
Normal the exhaust temperature sensor that is above The alarm
normal.  output is
NOTE: Turbocharger 1 is the right activated.  
side turbocharger. 

1184­4 
Engine Turbocharger 1 Turbine The code is
Outlet Temperature : Voltage Below The ECM has detected a voltage in the circuit for logged. 
Normal the exhaust temperature sensor that is below The alarm
normal.  output is
NOTE: Turbocharger 1 is the right activated.  
side turbocharger. 

1185­3 
Engine Turbocharger 2 Turbine The code is
Outlet Temperature : Voltage Above The ECM has detected a voltage in the circuit for logged. 
Normal the exhaust temperature sensor that is above The alarm
normal.  output is
NOTE: Turbocharger 2 is the left activated.  
side turbocharger. 

1185­4 
Engine Turbocharger 2 Turbine The code is
Outlet Temperature : Voltage Below The ECM has detected a voltage in the circuit for logged. 
Normal the exhaust temperature sensor that is below The alarm
normal.  output is
NOTE: Turbocharger 2 is the left activated.  
side turbocharger. 

Table 2
Diagnostic Codes Table 

System
Description  Conditions which Generate this Code 
Response 

The code is
1137­3 
logged. 
Engine Exhaust Gas Port 1 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  
The code is
1137­4 
logged. 
Engine Exhaust Gas Port 1 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  

The code is
1138­3 
logged. 
Engine Exhaust Gas Port 2 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sis… 2/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

1138­4  The Integrated Sensing Module (ISM) detects a The code is


 
Engine Exhaust Gas Port 2 signal voltage that is below normal.  logged. 
Temperature : Voltage Below The alarm 
Normal  output is
activated.  

The code is
1139­3 
logged. 
Engine Exhaust Gas Port 3 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

The code is
1139­4 
logged. 
Engine Exhaust Gas Port 3 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  
The code is
1140­3 
logged. 
Engine Exhaust Gas Port 4 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

The code is
1140­4 
logged. 
Engine Exhaust Gas Port 4 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  
The code is
1141­3 
logged. 
Engine Exhaust Gas Port 5 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

The code is
1141­4 
logged. 
Engine Exhaust Gas Port 5 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  

The code is
1142­3 
logged. 
Engine Exhaust Gas Port 6 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

The code is
1142­4 
logged. 
Engine Exhaust Gas Port 6 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  
The code is
1143­3 
logged. 
Engine Exhaust Gas Port 7 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sis… 3/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

1143­4  The Integrated Sensing Module (ISM) detects a The code is


 
Engine Exhaust Gas Port 7 signal voltage that is below normal.  logged. 
Temperature : Voltage Below The alarm 
Normal  output is
activated.  

The code is
1144­3 
logged. 
Engine Exhaust Gas Port 8 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

The code is
1144­4 
logged. 
Engine Exhaust Gas Port 8 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  
The code is
1145­3 
logged. 
Engine Exhaust Gas Port 9 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  
The code is
1145­4 
logged. 
Engine Exhaust Gas Port 9 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  
The code is
1146­3 
logged. 
Engine Exhaust Gas Port 10 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

The code is
1146­4 
logged. 
Engine Exhaust Gas Port 10 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  

The code is
1147­3 
logged. 
Engine Exhaust Gas Port 11 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  
The code is
1147­4 
logged. 
Engine Exhaust Gas Port 11 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  
The code is
1148­3 
logged. 
Engine Exhaust Gas Port 12 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sis… 4/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

1148­4  The Integrated Sensing Module (ISM) detects a The code is


 
Engine Exhaust Gas Port 12 signal voltage that is below normal.  logged. 
Temperature : Voltage Below The alarm 
Normal  output is
activated.  

The code is
1149­3 
logged. 
Engine Exhaust Gas Port 13 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  
The code is
1149­4 
logged. 
Engine Exhaust Gas Port 13 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  
The code is
1150­3 
logged. 
Engine Exhaust Gas Port 14 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  
The code is
1150­4 
logged. 
Engine Exhaust Gas Port 14 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  

The code is
1151­3 
logged. 
Engine Exhaust Gas Port 15 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

The code is
1151­4 
logged. 
Engine Exhaust Gas Port 15 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  
The code is
1152­3 
logged. 
Engine Exhaust Gas Port 16 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  
The code is
1152­4 
logged. 
Engine Exhaust Gas Port 16 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  
The code is
1153­3 
logged. 
Engine Exhaust Gas Port 17 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sis… 5/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

1153­4  The Integrated Sensing Module (ISM) detects a The code is


 
Engine Exhaust Gas Port 17 signal voltage that is below normal.  logged. 
Temperature : Voltage Below The alarm 
Normal  output is
activated.  
The code is
1154­3 
logged. 
Engine Exhaust Gas Port 18 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  
The code is
1154­4 
logged. 
Engine Exhaust Gas Port 18 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  

The code is
1155­3 
logged. 
Engine Exhaust Gas Port 19 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is above normal. 
output is
Normal 
activated.  

The code is
1155­4 
logged. 
Engine Exhaust Gas Port 19 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is below normal. 
output is
Normal 
activated.  

The code is
1156­3 
logged. 
Engine Exhaust Gas Port 20 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Above signal voltage that is below normal. 
output is
Normal 
activated.  

The code is
1156­4 
logged. 
Engine Exhaust Gas Port 20 The Integrated Sensing Module (ISM) detects a
The alarm
Temperature : Voltage Below signal voltage that is above normal. 
output is
Normal 
activated.  

Background Information
The Integrated Sensing Module (ISM) monitors type K thermocouples at each cylinder exhaust port and at
the inlets and outlets for both turbochargers. The (ISM) can also calculate the average temperature for each
cylinder bank (left and right). Temperature readings of the thermocouples are available over the Cat Data
Link for use by the Electronic Control Module (ECM) and by other modules. The temperatures can be
viewed on Caterpillar Electronic Technician (ET).

The (ISM) generates an event code for each of the following programmable conditions:

High exhaust temperature

High deviation of an exhaust port temperature

Low deviation of an exhaust port temperature

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sis… 6/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

High inlet temperature to the turbocharger turbine

High outlet temperature from the turbocharger turbine

A diagnostic code is generated by the (ISM) for the circuit of any thermocouple that is shorted to the
+Battery side, shorted to ground, or open.

Logged diagnostic codes provide a historical record. Before you begin this procedure, use Cat ET to print the
logged codes to a file.

This troubleshooting procedure may generate additional diagnostic codes. Keep your mind on correcting the
cause of the original diagnostic code. Clear the diagnostic codes after the problem is resolved.

Illustration 1 g03743379
Right side thermocouples

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sis… 7/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

Illustration 2 g03744214
Left side thermocouples

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sis… 8/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

Illustration 3 g03744217
Turbocharger in and turbocharger out thermocouples

Table 3
Troubleshooting Test Steps  Values  Results 

1. Check for Active Diagnostic Codes and Logged Results: A diagnostic code is logged but


Check for Logged Diagnostic Codes  Diagnostic is not active.
Codes 
Or  Repair: Do not troubleshoot a logged
A. Connect Caterpillar Electronic Technician Active code unless the code relates to an operator
(ET) to the service tool connector. Refer to Diagnostic complaint. If the code is logged and the
Troubleshooting, "Electronic Service Tools", if Codes code does not relate to an operator
necessary.   complaint, clear the code.

B. Download the "Product Status Report" from If the logged code relates to this
the engine ISM before performing any procedure, inspect the electrical
troubleshooting or clearing diagnostic trouble connectors and the wiring for the circuit. 
codes. Refer to Troubleshooting, "Electrical
Connectors ­ Inspect"
C. Monitor the active diagnostic code screen on
Results: A ­3 diagnostic code is active.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sis… 9/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation
Results: A ­3 diagnostic code is active.
Cat ET. Record any active diagnostic codes.
Proceed to Test Step 2.
Note. Wait at least 30 seconds in order for
diagnostic codes to become active. Results: A ­4 diagnostic code is active.
 
Proceed to Test Step 6. 

Results: The connectors and wiring are
2. Inspect the Electrical Connectors and the
OK.
Wiring
Proceed to Test Step 3.
A. Check the harness and the wiring for
abrasion and for pinch points. ­3 code 
Results: The connectors and/or wiring are
 
NOT OK.
B. Thoroughly inspect all connectors that are in
the circuit. Refer to Troubleshooting, "Electrical
Repair: Repair the connectors or wiring
Connectors ­ Inspect " for details.
and/or replace the connectors or wiring.
 
 

Results: The voltage is OK. The voltage
measurement is less than the +Battery
voltage. The signal wire is not shorted to
the +Battery.

3. Check for Battery Voltage on the Signal Proceed to Test Step 5.
Wire
­3 code  Note: The following Results: will cause a
A. At the sensor harness connector, measure the ­3 code.
voltage between the signal terminal and the (+)
return terminal. Battery Results: The voltage is NOT OK. The
voltage  voltage measurement is approximately the
B. Record the result. +Battery voltage. The signal wire is
  shorted to the +Battery.

Repair: Repair the wiring, when possible.
Replace parts, if necessary. Verify that the
problem is resolved.
 

4. Determine if the Sensor has an Open ­3 Code   Results: A ­3 diagnostic code is active


Circuit Condition by Creating a Short when the connector is disconnected. A ­4
Circuit at the Sensor Connector diagnostic code is active when the jumper
wire is shorting the circuit. 
A. Using appropriate terminals, fabricate a The sensor is NOT OK. 
jumper wire. The open is in the sensor.

B. At the sensor harness connector, connect the Repair: Perform the following procedure:
signal terminal and the return terminal with the
jumper wire. The jumper will replace the sensor 1. Temporarily connect a new sensor.
with a short circuit.
2. Recheck the circuit in order to ensure
Note. Wait at least 30 seconds in order for the that the original problem is resolved with
diagnostic codes to become active. the connection of the new the sensor.

3. If the problem is resolved with the new
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/si… 10/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

C. Record the resulting diagnostic code. sensor, reconnect the suspect sensor. If the
  problem returns with the connection of the
suspect sensor, permanently install the
new sensor.

4. Before returning the engine to service,
clear the logged diagnostic codes.

Results: The ­3 diagnostic code remains
active when the jumper wire is shorting
the circuit. 
The sensor is OK. 
The open is in the remainder of the circuit.

Proceed to Test Step 6.
 

5. Check the Operation of the ISM by ­3 code  Results: A ­3 diagnostic code is active


Creating a Short Circuit at the ISM when the wires are removed. A ­4
Connector diagnostic code is active when the jumper
wire is shorting the circuit.
A. At the ISM harness connector, remove the
signal wire and the return wire. The ISM is OK. There is an open in the
wiring that is between the ISM and the
B. Using appropriate terminals, fabricate a sensor.
jumper wire.
Repair: Perform the following procedure:
C. At the ISM harness connector, install the
jumper wire between the signal terminal 1. Repair the connectors or wiring and/or
location and the return terminal location. The replace the connectors or wiring. 
jumper will replace the engine wiring with a
short circuit. 2. Recheck the circuit in order to ensure
that the original problem is resolved.
Note. Wait at least 30 seconds in order for the
diagnostic codes to become active. 3. Before returning the engine to service,
clear the logged diagnostic codes.
D. Record the resulting diagnostic code.
  Results: The ­3 diagnostic code remains
active when the jumper wire is shorting
the circuit. 
The ISM appears to be NOT OK .

Note: Before you consider replacing the
ISM, consult with your Cat dealers
Technical Communicator (TC) for
assistance.

Repair: Perform the following procedure:

1. Temporarily connect a test ISM. 

Refer to Troubleshooting, "ECM ­
Replace".

2. Recheck the circuit in order to ensure
that the original problem is resolved.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/si… 11/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

If the problem is resolved with the test
ISM, reconnect the suspect ISM. If the
problem returns with the suspect ISM,
permanently install the new ISM. Verify
that the problem is resolved.

If the problem is not resolved with the test
ISM, install the original ISM. There is a
problem in the wiring.

3. Before returning the engine to service,
clear the logged diagnostic codes.
 

Results: The connectors and wiring are
6. Inspect the Electrical Connectors and the
OK.
Wiring
Proceed to Test Step 8.
A. Check the harness and the wiring for
abrasion and for pinch points.
­4 code  Results: The connectors and/or wiring are
Not OK.
B. Thoroughly inspect all connectors that are in
the circuit. Refer to Troubleshooting, "Electrical
Repair: Repair the connectors or wiring
Connectors ­ Inspect " for details.
and/or replace the connectors or wiring.
 
 

7. Determine if the Sensor has a Short ­4 code  Results: A ­4 diagnostic code is active


Circuit Condition by Creating an Open when the connector is connected. A ­3
Circuit at the Sensor Connector diagnostic code is active when the
connector is disconnected. 
A. Disconnect the harness connector from the The sensor is NOT OK. 
sensor that relates to the code. The short is in the sensor.

Note. Wait at least 30 seconds in order for the Repair: Perform the following procedure:
diagnostic codes to become active.
1. Temporarily connect a new sensor.
C. Record the resulting diagnostic code.
  2. Recheck the circuit in order to ensure
that the original problem is resolved with
the connection of the new the sensor.

3. If the problem is resolved with the new
sensor, reconnect the suspect sensor. If the
problem returns with the connection of the
suspect sensor, permanently install the
new sensor.

4. Before returning the engine to service,
clear the logged diagnostic codes.

Results: The ­4 diagnostic code remains
active when the connector is disconnected.
The sensor is OK. 
The open is in the remainder of the circuit.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/si… 12/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

Proceed to Test Step 10.
 

Results: A ­4 diagnostic code is active
when the wire is connected. A ­3
diagnostic code is active when the wire is
removed.

The ISM is OK. There is an open in the
wiring that is between the ISM and the
sensor.

Repair: Perform the following procedure:

1. Repair the connectors or wiring and/or
replace the connectors or wiring. 

2. Recheck the circuit in order to ensure
that the original problem is resolved.

3. Before returning the engine to service,
clear the logged diagnostic codes.

8. Check the Operation of the ISM by Results: The ­4 diagnostic code remains
Creating an Open Circuit at the ISM active after the wire is removed. 
Connector The ISM appears to be NOT OK .

A. At the ISM harness connector, remove the Note: Before you consider replacing the
signal wire. ISM, consult with your Cat dealers
­4 code 
Technical Communicator (TC) for
Note. Wait at least 30 seconds in order for the assistance.
diagnostic codes to become active.
Repair: Perform the following procedure:
C. Record the resulting diagnostic code.
  1. Temporarily connect a test ISM. 

Refer to Troubleshooting, "ECM ­
Replace".

2. Recheck the circuit in order to ensure
that the original problem is resolved.

If the problem is resolved with the test
ISM, reconnect the suspect ISM. If the
problem returns with the suspect ISM,
permanently install the new ISM. Verify
that the problem is resolved.

If the problem is not resolved with the test
ISM, install the original ISM. There is a
problem in the wiring.

3. Before returning the engine to service,
clear the logged diagnostic codes.
 
     
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/si… 13/14
19/02/2017 G3516H Generator Set GLN00001­UP(SEBP7018 ­ 08) ­ Documentation

Copyright 1993 ­ 2017 Caterpillar Inc.   Sun Feb 19 2017 10:39:26 GMT­0300 (Hora oficial do Brasil) 
All Rights Reserved.
uhyxel
Private Network For SIS Licensees.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/si… 14/14

You might also like