Professional Documents
Culture Documents
alternate course.
MAIN HOUSE MAIN HOUSE
E-03(1:100) E-04(1:100) 8. A single layer of 3-ply bituminous felt
is to be provided between masonry and
r.c work.
9. Depth of foundations to be decided
on site.
10. Drain pipes passing under
2.230 4.390 1.350 3.690
2.800 3.725 4.350 2.950 3.150 2.150
REVISIONS:
No. Date
A B C D E F G 1 2 3 4 5
0.600
W3 W3 W1 W1 D3 W1 W3
0.230
5 5
0.600
0.600
0.600
0.230
0.150 1.550
WC
2.000
LAUNDRY D2 ±0.000 WC
3.205
0.500
3.205
3.690
3.690
KITCHEN BEDROOM
3.500
0.300
0.150
1.200
4 W2 D2 LAUNDRY W2 4
CORRIDOR -0.050
1.350
1.350
1.200
1.350
±0.000
1.500
Cement and Sand screed
LIVING
0.950
9.660
9.660
0.150
0.600
ROOM
0.900
D3 1.200
LIBRARY
±0.000 LIVING
4.390
4.390
4.200
CAR
-500 FFL
Drawing title:
PORCH
MAIN HOUSE GROUND PLAN,
2 -0.150 D1
2 ELEVATIONS, SECTION
0.230
0.230
2.230
2.230
2.230
2.230
2.230
-0.050
2.230
2.230
Porcelain tiles
Scale: AS SHOWN
1 1 Foundation Detail
8.305 Drawn by: Lubangakene Brian
Porcelain Tile Floor finish on,
MAIN HOUSE
RAMP
0.600
0.600
0.600
Rough Sand screed 100mm thick concrete slab (1:3:6 mix ) on,
Gauge 1000mm visqueen or similar gauge dpm
Date: MAY 2019
SECTION A-A 1:50 50mm Clean Sand on,
Checked:
A
MAIN HOUSE
GROUND FLOOR (1:100)
A B C D E F G
GSPublisherVersion 0.0.100.100
GENERAL NOTES:
1. This drawing is copyright.
2. Do not scale off this drawing.
3. All levels and dimensions are to be
E D C B A 1 2 3 checked on site before any
RL 3.000 RL 3.000 RL 3.000 construction work begins.
BL 2.500 4. Any discrepancies are to reported to
1.615 3.690
3.190 3.150 4.160 3.690 BL 2.000
the Architect.
RL 4.285 RL 4.285
RL 4.100
RL 4.285 5. All work is to be strictly in
accordance with the standard
FL 0.000 FL 0.000
specifications and notes.
FL 0.000 FL 0.000
GL -0.300 GL -0.300 GL -0.300 GL -0.300
BL 2.500
drawings.
FL 0.000 FL 0.000 FL -0.050 FL 0.000 BL 2.000 BL 2.000 BL 2.000 7. Walls less than 200mm thick to be
GL -0.300 GL -0.300
alternate course.
E D C B A 1 2 3 FL 0.000
GL -0.300
FL 0.000
GL -0.300
FL 0.000
GL -0.300
FL 0.000
GL -0.300
8. A single layer of 3-ply bituminous felt
is to be provided between masonry and
BOYS QUARTERS BOYS QUARTERS OUTSIDE TOILET OUTSIDE TOILET r.c work.
E-03 (1:100) E-04 (1:100) E-O1 (1:50) E-O2 (1:50)
9. Depth of foundations to be decided
on site.
A B C D E 3 2 1
4.200 10. Drain pipes passing under
driveways and buildings to be encased
0.150 1.200 0.150 1.200 0.150 1.200 0.150
0.150
0.150
Roof Detail in 150mm thick concrete surround.
3.690 4.160 3.150 3.190
11. All reinforced concrete work to
1.200
1.200
3.690 1.615
50 pitch single plane roof
galvanised iron sheets
Structural engineer's drawings.
3.150
3.150
On 100x50mm wooden
0.150
0.150
RL 4.285 RL 4.285 RL 4.285
1.500
1.500
common rafters
foul sewerage details to Civil engineer's
0.150
0.150
BL 2.400 BL 2.400 BL 2.400 BL 2.400
0.150 1.200 0.150 1.200 0.150 1.200 0.150
drawings.
4.200
13. All mechanical and electrical works
to M&E engineers' drawings.
FL 0.000 FL 0.000 FL 0.000 FL -0.050
GL -0.300 GL -0.300 GL -0.300 GL -0.300 REVISIONS:
No. Date
A B C D E 3 2 1
BOYS QUARTERS
E-01 (1:100) BOYS QUARTERS
E-02 (1:100)
1 2 3
Roof Detail
250 gauge galvanised iron Foundation Detail
sheets Porcelain Tile Floor finish on,
On 100x50mm wooden 100mm thick concrete slab (1:3:6 mix ) on,
purlins; 100x50mm Gauge 1000mm visqueen or similar gauge dpm
common rafters and 50mm Clean Sand on,
struts on 150x50mm 150mm hardcore on,
single tie beams; sitted Well compacted & treated laterite
on a 100x75mm wallplate. RL 4.285
RL 4.100
A B C D E
0.600
0.600
0.230
0.230
3.690
MR BRIAN MBAZIRA
±0.000 ±0.000 ±0.000
Cement and sand screed
3.460
3.460
Cement and sand screed Cement and sand screed Cement and sand screed
FL -0.050 FL 0.000
5.535
5.535
0.230
1.615
-0.050
1.615
Scale: AS SHOWN
0.600
0.600
A B C D E
BOYS QUARTERS
1 2 3
GROUND PLAN (1:100)
GSPublisherVersion 0.0.100.100
GENERAL NOTES:
1. This drawing is copyright.
2. Do not scale off this drawing.
3. All levels and dimensions are to be
TO KAGA
YI checked on site before any
OUTSIDE
ERERE construction work begins.
TO BUK
TOILET
TO K
CEN T
TRADING
5. All work is to be strictly in
SEPTIC TANK
0
.50
AGA
21 accordance with the standard
LA
specifications and notes.
6. This drawing is to be read in
32 conjunction with other relevant
BOYS .5
00
QUARTERS OUTSIDE
TOILET
drawings.
7. Walls less than 200mm thick to be
SEPTIC TANK
0 0
2 1.5
32
BOYS .5
00
QUARTERS
MAIN
HOUSE reinforced with hoop iron at every
alternate course.
MAIN 8. A single layer of 3-ply bituminous felt
VISITORS PARKING
COMPOUND
38 315m2
.5
m
HOUSE
is to be provided between masonry and
0
00
22
15
N
.8
07
r.c work.
GATE
00
3.5
9. Depth of foundations to be decided
on site.
10. Drain pipes passing under
driveways and buildings to be encased
in 150mm thick concrete surround.
11. All reinforced concrete work to
Structural engineer's drawings.
12. All road, stormwater drainage and
VISITORS PARKING
COMPOUND
SITE MAP foul sewerage details to Civil engineer's
38 315m2
.5
m (NTS) drawings.
13. All mechanical and electrical works
to M&E engineers' drawings.
N 100mm th.slab(mix.1:2:4)reinforced with
Y12 Bars at 150mm c/c both way
600 x 450 mm
precast conc. cover
100mm dia .Agricultural pipe
laid open joint
0
100mm dia . Half Round Y
REVISIONS:
00 100mm dia Salt Junction Channel to soak pit
No. Date
22
glazed stone
Cast Iron
pipe
Channel Stop
15
Inlet pipes
07
450x450
100mm dia half round
300 min
B mm MH
Benching
channel 100mm dia . 100mm dia Cast Iron
IN OUT Half Round Channel
L 100mm dia
Cast Iron Outlet
pipe drain to soak pit
WORKING LEVEL INLET CHAMBER pipe
GATE
00
EFFLUENT DISTRIBUTION
125mm thick concrete base
BLOCK PLAN SECTIONAL Scale 1:100 CHAMBER
gl. support bracket built into
3.5
450 min
25mm th. cement screed PERCOLATION TRENCH SYSTEM
gl. support bracket built into
finished smooth with steel float. 600 x 450 mm cast iron cover Selected Filling in 6
Concrete to foundation (mix 1:3:6) 230mm thick block wall 900 layers wll rammed and
TO BE DETERMINED ON SITE
Y
with steel float
Selected stone ROOFING FELT
Invert
100mm dia. inlet / level
600x450mm Prer-cast
750
600x450mm Prer-cast Conc. D outlet SELECTED
Conc. cover 100mm dia .Agricultural
cover with12mm dia.mild steel cast iron pipe STONE 150
to form lifting handles B pipe laid open joint DOWN TO
( mean fall 1 in 100) 20mm
Project:
SEPTIC TANK DETAILS (NTS) PROPOSED RESIDENTIAL
DEVELOPMENT AT KAGALA
DOOR SCEDULES (1:100) VILLAGE, GOMA SUBCOUNTY
KYAGWE, MUKONO
Label D2 D2 D3 WINDOW SCHEDULES ( 1:100 )
Client: Sign:
PERCOLATION
1.500 0.900 Label W1 W2 W3 No. OF CAPACITY MR BRIAN MBAZIRA
TRENCH
0.900
0.700
2.400
2.400
1.500
1.500
0.100
30 2358.0
MAIN HOUSE BOYS QUARTERS MAIN HOUSE BOYS QUARTERS MAIN HOUSE BOYS QUARTERS
GSPublisherVersion 0.0.100.100