Background
Some of the functions related to the VECU do not work. Check the voltage supply to the VECU.
Exercise description
Find the reason why the VECU does not work. Measure the feed circuit to the VECU.
A17 VECU
F07 Fuse
K02 Relay EMS
Material
Multimeter
PA
999 8699 - Break-out-box 981 3194 - 10/16/30 connector cable 999 0130 - Overlay
PB
999 8699 - Break-out-box 999 8533 - 22/30 connector cable 999 0130 - Overlay
XL
999 8699 - Break-out-box 999 0025 - 18/21 connector cable 999 0133 - Overlay
Attachment
Wiring diagram BA.
T3016253
10
T3016421
142
T3016422
143