Professional Documents
Culture Documents
K3 C3 ESP
0.884 Nm3/kg-Clk CS Fan Cooler ESP
K4 1930/86.20 kW/%
C4
K6 C6
Cal.
Calciner Firing Kiln Firing
0.072 kg-Coal/kg-Clk 0.044 kg-Coal/kg-Clk
0.020 Nm3w/kg-clk 0.020 Nm3w/kg-clk
0.508 Nm /kg-Clk
3
T.A. Duct
Primary Air
0.020 Nm3w/kg-clk
KILNKILN 1136 deg.C
3.56 %
Inlet O2 4.2 rpm
False Air a/c KS, Nm3w/kg-clk 0.030 50 %
False Air a/c CS, Nm3w/kg-clk 0.052 0.357 Nm3w/kg-clk Cooler
False Air a/c Cooler, Nm w/kg-clk
3
0.009
0.026 kgd/kg-clk
0.025 kgd/kg-clk
0.638
1.349
kgd/kg-clk
0.369 0.391
0.079
0.448
1.029 1.344 0.004
0.007 kgd/kg-clk
kgd/kg-clk
Percent Coal Transport Air % 7.08 Cooler Grate-I/II/III speed spm 15.8/16.6/17.6
C.T.A. Tip Velocity m/sec 37 Cooler Grate-I/II/III load amps 69/56/55
Flame Momentum (CTA) %.m/sec 260 Burning Zone Temperature/Kiln Torque deg.C/% 1136/50
Total Flame Momentum %.m/sec 1188 Cooler ESP Fan Load kW 185
Cooler Air m3/s/m2 1.51 Cooler ESP Fan Speed % 60
Cooler Loading tpd/m2 62.2 Tert. Air Draft mmWG -38
Secondary Air Temperature deg.C 1109 Hood Draft mmWG -6
Tertiary Air Temperature deg.C 905 Dust Losses - PH % 8.11
PLANT : Binani Cement - 20.06.2003 <<< ERRORS >>>
Hot air to PA Fan (Yes/No) yes Heat-1 0.00 Heat-2 0.00
Axial Air Contribution, % 100 Heat-3 0.00 Heat-4 0.00
Heat-5 0.00 Heat-6 0.00
Heat-7 0.00 Heat-8 0.00
String String PH Gas Vent Air Kiln Cal. Kiln I/L Cal. O/L Cooler
Dry Bulb Temp. deg.C 306 302 304 285 87 73 75 807 811 31
Water Vapor kg/kg-dg 0.110 0.110 0.110 0.030 0.021 0.021 0.020 0.012 0.012 0.012
Avg. Ps mmWG -575 -864 -753 -40 1020 3305 2960 -66 -234 -6
Gas Density, dry kg/Nm3 1.47 1.52 1.50 1.29 1.29 1.29 1.29 1.41 1.54 1.29
Gas Density, wet kg/Nm3 1.36 1.40 1.38 1.27 1.28 1.28 1.28 1.40 1.53 1.28
Gas Density, dry kg/m3 0.62 0.63 0.62 0.60 1.03 1.30 1.26 0.34 0.36 1.10
Gas Velocity m/s 15.2 21.2 22.1 13.1 13.7 27.9 28.2 - - -
Gas Flow Rate, wet tph 193.68 310.38 504.06 349.20 6.31 6.57 6.42 10.69 19.89 2.84
Gas Flow Rate, wet km3/hr 336.90 539.90 876.81 593.07 6.21 5.13 5.18 32.01 55.75 2.59
Moisture, by diff. tph 19.2 30.8 50.0 10.0 0.1 0.1 0.1 0.1 0.2 0.0
Gas Flow Rate, dry tph 174.49 279.62 454.11 339.17 6.18 6.44 6.30 10.57 19.65 2.81
Gas Flow Rate, dry kNm3/hr 118.40 183.96 302.29 262.29 4.78 4.98 4.87 7.48 12.74 2.17
Gas Flow Rate, dry km3/hr 280.37 446.96 727.32 566.15 6.00 4.96 5.02 31.35 54.49 2.55
Heat Cap., gas kcal/kg/C 0.263 0.261 0.262 0.250 0.244 0.244 0.244 0.263 0.264 0.242
Heat Content, gas Mcal/hr 15548 24527 40075 24911 134 117 118 2268 4251 21
Heat Content, total Mcal/hr 16475 25994 42469 25209 134 117 118 2268 4251 21
0 0.046850 0 0.005790
2 0.045465 5 0.005790
4 0.044088 10 0.008630
6 0.042722 15 0.010610
8 0.041365 20 0.012620
25 0.014690
30 0.016800
35 0.018950
40 0.021150
45 0.024520
50 0.028210
55 0.032110
60 0.035150
Air Stack ESP PA Fan Fan I/L Fan I/L kg/kg-clk deg.C kcal/kg/C kcal/kg-clk
1.22 0.69 1.22 0.69 0.60 0.59 ESP False Air Optimisation 7.24
- S2 - - S2 S2
- - - - 12.98 20.81
- - - - 0.234 0.233
- - - - 925 1466
0.0296
-40
21.00
0.00
79.00
1.215
1.681
1.069
0.684
25.52
0.00
84.44
3.25
22.54
0.00
74.59
2.87
1.293
1.271
1.100
1.081
0.245
0.178
INPUT
OUTPUT
4 Dust with Cooer Vent Air 5095 - 285 0.205 298061 1.2
10 Balance/Losses - - - - 2 0.00
0.2485 -3.340E-06
0.1244 0.000E+00
O2 0.2130 7.796E-05
A 23.5771
B -4042.90
C -37.58
-3.673E-08
0.000E+00
-1.283E-07 5.074E-11
0.000E+00
0.000E+00
0.000E+00
0.000E+00
0.000E+00
VDZ Efficiency
S. Constriants Mass Temp. Cp Heat
No. kg/kg-Clk deg.C kcal/kg/ oC kcal/hr kcal/kg-Clk
1 Clinker from Kiln 1.000 1450 0.264 96340716 383
2 Clinker at Amb. Temperature 1.000 31 0.178 -1391460 -6
3 Clinker from Cooler 1.000 140 0.192 -6747366 -27
4 Power to Cooler Fans - - - 1142273 5
5 Excess Air, Out 1.388 285 0.250 -24911420 -99
6 Excess Air, In 0.011 31 0.242 21291 0
7 Surface Losses - - - -381650 -2
8 Heat Absorption by Comb. Air - - - 65463843 260
9 Max. Heat Release from Clink - - - 94949256 378
COOLER EFFICIENCY, % 68.95
Ash Content % 19.90 Sp. Heat Consump., kcal/kg-Clk 261 426 687
Combustion of Coal :
Component Wt. Fraction Fuel O2 CO2 H2O SO2
Kiln I/L Draft -66 mmWG Cal. I/L Draft -45 mmWG
Kiln I/L Temp. 807 deg.C Cal. I/L Temp. 880 deg.C
7 Kiln Riser Duct 17.5 3100 3100 214 7.14 410.40 15.97 1.10
Alkali silicates :
(K2O + Na2O)rawmix 0.65 -14.80 -9.62 -14.56
Heat of Decomposition : -1439.62 -2178.67
B: HEAT OF FORMATION
Property Component Adj. Raw Mix
C3S CaO 43.23 -0.46 -19.89 -30.10
C2S SiO2 13.75 21.43 294.62 445.87
C3A Al2O3 4.23 1.21 5.11 7.74
C4AF Fe2O3 2.38 2.46 5.86 8.87
SO3 in clinker from fuel and pyrites 0.33 59.60 19.45 29.44
Heat of Formation : 305.16 461.82
C : HEAT OF COMBUSTION
Carbon 0.20 327.86 65.57 99.23
Sulphur in pyrites 0.04 129.14 5.17 7.82
Heat of Combustion : 70.74 107.05
e
d
E V
b
c a
K
Legends
Evaporation Factor, E = d/b = (b-c)/b Residual Component, R = c/a
0.20 0.37
FN1 FN2 FN3 FN4 FN5 FN6 FN7 FN8 FN9 FNA FNB FNC FNH Total
Dry Bulb Temp. deg.C 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0
Wet Bulb Temp. deg.C 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0
Dew Point (F4) deg.C 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0
Dew Point, calc. deg.C 22.7 22.7 22.7 22.7 22.7 22.7 22.7 22.7 22.7 22.7 22.7 22.7 22.7 22.7
Water Vapor kg/kg-dg 0.0181 0.0181 0.0181 0.0181 0.0181 0.0181 0.0181 0.0181 0.0181 0.0181 0.0181 0.0181 0.0181 0.0181
Avg. Ps mmWG 660 685 866 827 795 788 645 625 640 655 570 515 565 651
Moisture, by diff. tph 0.49 0.51 0.48 0.46 0.66 0.73 1.60 0.76 0.57 1.09 1.32 1.53 0.61 10.81
Gas Flow Rate, dry tph 27.1 28.0 26.4 25.3 36.5 40.5 88.4 42.0 31.6 60.0 73.1 84.5 33.7 597.0
Gas Flow Rate, dry kg/min 451 466 440 422 609 675 1474 700 527 1000 1218 1408 561 9950
Gas Flow Rate, dry m3/min 388 401 378 363 524 580 1267 602 453 860 1047 1211 483 8556
Sp. Heat, gas kcal/kg/C 0.243 0.243 0.243 0.243 0.243 0.243 0.243 0.243 0.243 0.243 0.243 0.243 0.243 0.243
Heat Content, gas Mcal/hr 234 242 228 219 316 350 766 363 274 519 632 731 291 5168
Fan Speed rpm 2765 2757 1341 1342 1371 1365 1412 - - 1475 1488 1475 1489 -
Fan Load amps 108 106 138 130 160 165 291 139 116 185 222 188 105 2053
Fan Damper % 100 100 100 100 100 100 100 100 100 100 100 100 100 -
Sp. Air Consmp. kg/kg-Clk 0.110 0.113 0.107 0.102 0.148 0.164 0.358 0.170 0.128 0.243 0.296 0.342 0.136 2.417
Sp. Air Consmp. Nm3/kg-Clk 0.086 0.088 0.084 0.080 0.116 0.128 0.280 0.133 0.100 0.190 0.231 0.267 0.107 1.889
374 374 631 631 946 946 1439 507 507 1014 1014 1099 500 9982
399 412 389 373 539 597 1304 619 467 885 1078 1246 497 8804.61
Heat Cap - Coefficients
Gas/Mat *T^0 *T^1 *T^2 *T^3 *T^4
0.2485 -3.340E-06 4.440E-08 -2.797E-11 5.597E-15 Not used in calc.
0.1244 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Not used in calc.
O2 0.2130 7.796E-05 -7.563E-08 4.074E-11 -8.183E-15
CO2 0.1906 1.771E-04 -1.733E-07 9.315E-11 -1.894E-14
N2+Ar 0.2465 -3.284E-06 4.366E-08 -2.750E-11 5.504E-15
H2O,steam 0.4445 2.910E-05 6.887E-08 -3.726E-11 6.472E-15
H2O, liq. 1.0000
Cooler Fans Flow : SLC 6-Stage II-String(with transmeter pezo pressure)
Kiln Output = 6035 tpd Sp. Air Consp. = 1.87 Nm3/kg-Clk Plant Elevation = 402.00 mts +MSL
Ambient Air = 36.0 deg.C Air Density = 1.086 kg/m3 Barometric Press. = 9827 mmWG
S. Fan I/L Dia I/L Area Fan kW Fan Speed (rpm) Damper FACTOR Ps Ps Flow (m3/min)
No. 471 m m2 Rated Run amps Rated Run % mmwg mmwg Inlet Outlet
1 FN1 0.45 0.159 90 58 85 2900 2663 100 40.56 143.63 660.00 413 398
2 FN2 0.45 0.159 90 56 82 2900 2616 100 40.56 153.50 685.00 427 411
3 FN3 0.56 0.246 132 90 132 1450 1376 100 62.81 59.13 866.00 411 388
4 FN4 0.56 0.246 132 92 134 1450 1407 100 62.81 53.88 827.00 392 372
5 FN5 0.71 0.396 180 117 171 1480 1411 100 100.97 43.13 795.00 564 537
6 FN6 0.71 0.396 190 117 172 1480 1394 100 100.97 52.88 788.00 624 595
7 FN7 0.90 0.636 225 202 296 1485 1492 100 162.24 98.13 645.00 1366 1319
10 FNA 0.80 0.503 160 138 202 1485 1481 100 128.19 70.38 655.00 914 882
11 FNB 0.80 0.503 160 145 212 1485 1476 100 128.19 102.75 570.00 1104 1074
12 FNC 0.90 0.636 132 - - 1485 - 100 162.24 84.88 515.00 1270 1242
13 FNH 0.56 0.246 90 76 112 1470 1496 - 62.81 187.63 565.00 731 712
- - - - - - - - 9335 9012
a) Kiln feed 415 tph b) Coal - Kiln/Cal. 521/525 rpm c) Gr. load - I/II/III 55/60/52 amps
d) DG - Kiln/Cal. 39.6/61.4 %/% e) Hood draft/ESP temp. -4/320 mmWG/deg.C f) Gr. DP-I/II/III 165/145/97mmWG
54 52 68 64
FN3 59.125
55 51 71 58
66 53 62 68
FN4 53.875
49 47 43 43
43 47 55 50
FN5 43.125
43 37 33 37
66 64 61 49
FN6 52.875
55 43 42 43
90 100 101 99
FN9 81.25
67 66 65 62
73 89 107 75
FNA 70.375
54 53 60 52
Page - 19/29
Kiln String Radiations : SLC 6-Stage II-String
Page - 20/29
Kiln String Radiations : SLC 6-Stage II-String
KS Surface Area Corr. Factor Corr. Area Temperature Radiation
Cyclone-4 m 2
- m 2
deg.C kcal/hr
Roof 29.4 1.20 35.3 98.0 34441
Vertical Inlet 52.9 1.01 53.4 75.0 32213
Conical Inlet 33.2 1.00 33.2 70.0 18121
Cylindrical Part 63.2 1.00 63.2 76.0 38643
Conical Part 59.2 1.00 59.2 125.0 82517
Material Pipes 8.3 1.01 8.4 162.0 19313
Riser Cylindrical 41.0 1.01 41.4 100.0 41384
Riser Rest 97.0 1.01 98.0 110.0 108700
Total/Wt. Avg. 384.2 392.1 97.6 375334
Page - 21/29
Calciner String Radiations : SLC 6-Stage II-String
Amb. Air 31.00 deg.C Emissivity
Production 6036 tpd Preheater 0.75
Total Radiation 3212876 ** kcal/hr Calciner 0.75
*
Sp. Radiation 12.77 kcal/kg-clk
*** Exclusive of amount as per FLS norms 5.00 %
Page - 22/29
Calciner String Radiations : SLC 6-Stage II-String
Page - 23/29
Cooler.Hood.TAD Radiations : SLC 6-Stage II-String
TA Duct & Surface Area Corr. Factor Corr. Area Temperature Radiation
Settling Chamb. m 2
- m 2
deg.C kcal/hr
Connecting Duct 57.0 1.10 62.7 133.0 95945
Tert. Pipe 582.8 1.00 582.8 143.4 899367
Total/Wt. Avg. 639.8 645.5 142.4 995312
Wt. Avg. Dia. <= 3.05 >3.05
2859 4.55 39811 48732
3002 4.55 43473 52653
2616 4.55 33962 42408
3960 4.55 72754 83349
3145 4.55 47307 56731
1458 4.55 11897 17214
3316 4.55 52142 61843
3088 4.55 45752 55081
3288 4.55 51318 60974
3359 4.55 53393 63160
3416 4.55 55086 64940
3459 4.55 56376 66294
3245 4.55 50096 59684
3088 4.55 45752 55081
3073 4.55 45368 54672
3130 4.55 46915 56316
3173 4.55 48095 57566
3059 4.55 44985 54265
2716 4.55 36314 44962
2573 4.55 32977 41335
2530 4.55 32007 40274
2544 4.55 32329 40626
2873 4.55 40169 49118
3130 4.55 46915 56316
3030 4.55 44226 53456
2873 4.55 40169 49118
2787 4.55 38042 46829
2902 4.55 40892 49892
3588 4.55 60350 70454
4474 4.55 92386 103567
4560 4.55 95958 107227
3502 4.55 57683 67664
4946 4.55 113176 124813
1286 4.55 9369 14045
4803 4.55 106575 118081
4703 4.55 102113 113523
4746 4.55 104010 115461
4631 4.55 99004 110344
4531 4.55 94758 105997
4717 4.55 102743 114167
4689 4.55 101486 112883
4617 4.55 98390 109716
4588 4.55 97169 108466
4646 4.55 99621 110975
4560 4.55 95958 107227
4546 4.55 95357 106611
4345 4.55 87194 98237
4074 4.55 76860 87594
1615 4.55 14375 20228
1401 4.55 11034 16144
1830 4.55 18006 24522
2287 4.55 26762 34483
2359 4.55 28260 36148
2330 4.55 27656 35478
1844 4.55 18258 24817
1687 4.55 15552 21635
3431 4.55 55514 65389
3502 4.55 57683 67664
3659 4.55 62627 72831
3659 4.55 62627 72831
1215 4.55 8371 12760
2716 4.55 36314 44962
2530 4.55 32007 40274
2487 4.55 31050 39224
2630 4.55 34293 42769
3302 4.55 51729 61408
3559 4.55 59453 69517
3616 4.55 61255 71399
3659 4.55 62627 72831
225563 3794136 4437254
15.09 17.64
2137 6.470 9795 15536
3641 8.138 18344 27622
1675 5.642 7988 12762
6866 12.494 25143 38720
3115 8.269 12085 19331
1962 3.778 22258 28619
7393 11.203 40379 57314
5193 10.086 23799 35751
31981 159792 235656
Process Parameters :
CC/MC, % S, % Ash, % S, %
CCR Parameters :
sheet 2 of 5
sheet 3 of 5
mmWG mmWG
deg.C deg.C
K-1 C-1
mmWG mmWG
deg.C deg.C
mmWG
deg.C
K-2 C-2
mmWG
deg.C
mmWG mmWG
deg.C deg.C
K-3 C-3
mmWG mmWG
deg.C deg.C
mmWG
deg.C
K-4 C-4
mmWG
deg.C
mmWG mmWG
deg.C deg.C
K-5 C-5
mmWG mmWG
deg.C deg.C
mmWG mmWG
deg.C deg.C
mmWG mmWG
deg.C deg.C
400
10.00
11.00
10.00
8.00
10.00
11.00
10.00
9.00
9.875
Norms :
1. Depending upon the particle size distribution of the clinker, the expected air load for normal operation corresponds to about :
a) ~90 kg/m2/min for 1st/2nd part of Grate-I c) ~45 kg/m2/min for 1st Sealing Air Fan e) ~55 kg/m2/min for Grate-II
b) ~80 kg/m2/min for 3rd part of Grate-I d) ~35 kg/m2/min for 2nd Sealing Air Fan f) ~50 kg/m2/min for Grate-III
2. Minimum air flow rates are about 85% of the normal flow rates.
Grate-II (RFT)
1 11 1 M
471FN1 6 F
471FN2 Nor. Pr. = 723 mm WG 3 M
723 mm WG Grate Area = 3.6 m2 4 F
3.6 m2
CIS 244 m3/min 5 M
Min. Flow =
244.29 m3/min Nor. Flow = 287 m3/min 6 F
287.4 m3/min 471FNA 1 M
1 F 525 mm WG 2 F
2 Grate-I (CFG) M 7.09 m2 3 M
471FN4 3 F 532 m3/min 4 F 471FN8
765 mm WG 4 M 626 m3/min 5 M 450 mm WG
6.5 m2 5 F 471FN3 6 F 7.09 m2
498 m3/min 6 M 765 mm WG 1 M 532 m3/min
586 m3/min 7 F 6.5 m2 2 F 626 m3/min
471FN9 8 M 498 m3/min 3 M
615 mm WG 9 F 586 m3/min 4 F
13 m2 10 M 471FN7 5 M
425 m3/min 11 F 375 mm WG 6 F
500 m3/min 1 M 11.81 m2 7 M
471FNH 2 F 1065 m3/min 8 F
530 mm WG 2 M 1253 m3/min 9 M
21.38 m2 4 F 10 F
431 m3/min 5 M
507 m3/min 6 F Grate-III (RFT)
7 M 1 M
471FN6 8 F 471FN5 2 F
680 mm WG 9 M 680 mm WG 3 M
10.69 m2 10 F 10.69 m2 4 F
646.48 m3/min 11 M 646.48 m3/min 5 M
762.97 m3/min 12 F 762.97 m3/min 6 F
13 M 7 M 471FNB
14 F 8 F 300 mm WG
15 M 9 M 16.54 m2
16 F 10 F 693.07 m3/min
17 M 11 M 815.40 m3/min
18 F 12 F
13 M
14 F
1 M
2 F
3 M
Cooler Fans 4 F
Fan Vol. Flow, Density Temp. D.P. Power, Speed Grate 5 M
design min. Plates 6 F 471FNC
m3/min kg/m3 o
C mmWG kW rpm nos. 7 M 300 mm WG
471FN1 373 1.04 45 1000 83 2900 27 8 F 14.18 m2
471FN2 373 1.04 45 1000 83 2900 27 9 M 739.67 m3/min
471FN3 631 1.04 45 900 122 1450 60 10 F 873.63 m3/min
471FN4 631 1.04 45 900 122 1450 60 11 M
471FN9 500 1.04 45 800 76 1485 Press. Fan 12 F
471FN5 946 1.04 45 800 165 1480 108
471FN6 946 1.04 45 800 165 1480 108
471FNH 507 1.04 45 700 90 1470 Press. Fan Cooler Grates
471FN7 1439 1.04 45 700 225 1485 72 Grate Length Area Power Plates Rows
471FN8 507 1.04 45 700 76 1485 72 mts m2 kW nos. nos.
471FNA 1014 1.04 45 600 136 1485 120 CIS 2.4 6.48 - 54 6
471FNB 1446 1.04 45 500 136 1485 168 I 9.57 34.64 60 348 29
471FNC 1099 1.04 45 500 123 1485 144 II 7.26 26.28 45 264 22
Total 10413 1602 822 III 8.58 31.06 45 312 26
Total 27.81 98.46 - 924 83
Norms :
1. Depending upon the particle size distribution of the clinker, the expected air load for normal operation corresponds to about :
a) ~90 kg/m2/min for 1st/2nd part of Grate-I c) ~45 kg/m2/min for 1st Sealing Air Fan e) ~55 kg/m2/min for Grate-II
b) ~80 kg/m2/min for 3rd part of Grate-I d) ~35 kg/m2/min for 2nd Sealing Air Fan f) ~50 kg/m2/min for Grate-III
2. Minimum air flow rates are about 85% of the normal flow rates.
Grate-II (RFT)
1 11 1 M
471FN1 6 F
471FN2 Nor. Pr. = 723 mm WG 3 M
723 mm WG Grate Area = 3.24 m2 4 F
3.24 m2
CIS 244 m3/min 5 M
Min. Flow =
244.29 m3/min Nor. Flow = 287 m3/min 6 F
287.4 m3/min 471FNA 1 M
1 F 525 mm WG 2 F
2 Grate-I (CFG) M 7.09 m2 3 M
471FN4 3 F 532 m3/min 4 F 471FN8
765 mm WG 4 M 626 m3/min 5 M 450 mm WG
6.5 m2 5 F 471FN3 6 F 7.09 m2
498 m3/min 6 M 765 mm WG 1 M 532 m3/min
586 m3/min 7 F 6.5 m2 2 F 626 m3/min
471FN9 8 M 498 m3/min 3 M
615 mm WG 9 F 586 m3/min 4 F
13 m2 10 M 471FN7 5 M
425 m3/min 11 F 375 mm WG 6 F
500 m3/min 1 M 11.81 m2 7 M
471FNH 2 F 1065 m3/min 8 F
530 mm WG 2 M 1253 m3/min 9 M
21.38 m2 4 F 10 F
431 m3/min 5 M
507 m3/min 6 F Grate-III (RFT)
7 M 1 M
471FN6 8 F 471FN5 2 F
680 mm WG 9 M 680 mm WG 3 M
10.69 m2 10 F 10.69 m2 4 F
646.48 m3/min 11 M 646.48 m3/min 5 M
762.97 m3/min 12 F 762.97 m3/min 6 F
13 M 7 M 471FNB
14 F 8 F 300 mm WG
15 M 9 M 16.54 m2
16 F 10 F 693.07 m3/min
17 M 11 M 815.40 m3/min
18 F 12 F
13 M
14 F
1 M
2 F
3 M
Cooler Fans 4 F
Fan Vol. Flow, Density Temp. D.P. Power, Speed Grate 5 M
design min. Plates 6 F 471FNC
m3/min kg/m3 o
C mmWG kW rpm nos. 7 M 300 mm WG
471FN1 373 1.04 45 1000 83 2900 27 8 F 14.18 m2
471FN2 373 1.04 45 1000 83 2900 27 9 M 739.67 m3/min
471FN3 631 1.04 45 900 122 1450 66 10 F 873.63 m3/min
471FN4 631 1.04 45 900 122 1450 66 11 M
471FN9 500 1.04 45 800 76 1485 Press. Fan 12 F
471FN5 946 1.04 45 800 165 1480 108
471FN6 946 1.04 45 800 165 1480 108
471FNH 507 1.04 45 700 90 1470 Press. Fan Cooler Grates
471FN7 1439 1.04 45 700 225 1485 72 Grate Area Plates Rows
471FN8 507 1.04 45 700 76 1485 72 m2 nos. nos.
471FNA 1014 1.04 45 600 136 1485 120 CIS 6.48 54 6
471FNB 1446 1.04 45 500 136 1485 168 I 34.22 348 29
471FNC 1099 1.04 45 500 123 1485 144 II 25.96 264 22
Total 10413 1602 978 III 30.68 312 26
Total 97.35 978 83
Norms :
1. Minimum air flow rates are about 85% of the normal flow rates.
Note :
First 07 rows+1(Zero) Row = Total Eight Rows of CFG replaced with CIS (06 Rows) in the month of Jun -2001
Grate-II (RFT)
1 11 1 M
471FN1 6 F
471FN2 Nor. Pr. = 1000 mm WG 3 M
1000 mm WG Grate Area = 3.24 m2 4 F
3.24 m2
CIS 373 m3/min 5 M
Op. Flow =
373 m3/min 6 F
471FNA 1 M
1 F 525 mm WG 2 F
2 Grate-I (CFG) M 7.09 m2 3 M
471FN4 3 F 532 m3/min 4 F 471FN8
900 mm WG 4 M 626 m3/min 5 M 450 mm WG
6.5 m2 5 F 471FN3 6 F 7.09 m2
631 m3/min 6 M 900 mm WG 1 M 532 m3/min
7 F 6.5 m2 2 F 626 m3/min
471FN9 8 M 631 m3/min 3 M
800 mm WG 9 F 4 F
13 m2 10 M 471FN7 5 M
500 m3/min 11 F 375 mm WG 6 F
1 M 11.81 m2 7 M
471FNH 2 F 1065 m3/min 8 F
700 mm WG 2 M 1253 m3/min 9 M
21.38 m2 4 F 10 F
507 m3/min 5 M
6 F Grate-III (RFT)
7 M 1 M
471FN6 8 F 471FN5 2 F
800 mm WG 9 M 800 mm WG 3 M
10.69 m2 10 F 10.69 m2 4 F
946 m3/min 11 M 946 m3/min 5 M
12 F 6 F
13 M 7 M 471FNB
14 F 8 F 300 mm WG
15 M 9 M 16.54 m2
16 F 10 F 693.07 m3/min
17 M 11 M 815.40 m3/min
18 F 12 F
13 M
14 F
1 M
2 F
3 M
Cooler Fans 4 F
Fan Vol. Flow, Density Temp. D.P. Power, Speed Grate 5 M
Operating min. Plates 6 F 471FNC
m3/min kg/m3 o
C mmWG kW rpm nos. 7 M 300 mm WG
471FN1 373 1.04 45 1000 83 2900 27 8 F 14.18 m2
471FN2 373 1.04 45 1000 83 2900 27 9 M 739.67 m3/min
471FN3 631 1.04 45 900 122 1450 66 10 F 873.63 m3/min
471FN4 631 1.04 45 900 122 1450 66 11 M
471FN9 500 1.04 45 800 76 1485 Press. Fan 12 F
471FN5 946 1.04 45 800 165 1480 108
471FN6 946 1.04 45 800 165 1480 108
471FNH 507 1.04 45 700 90 1470 Press. Fan Cooler Grates
471FN7 1439 1.04 45 700 225 1485 72 Grate Area Plates Rows
471FN8 507 1.04 45 700 76 1485 72 m2 nos. nos.
471FNA 1014 1.04 45 600 136 1485 120 CIS 6.48 54 6
471FNB 1446 1.04 45 500 136 1485 168 I 34.22 348 29
471FNC 1099 1.04 45 500 123 1485 144 II 25.96 264 22
Total 10413 1602 978 III 30.68 312 26
Total 97.35 978 83
Norms :
1. Depending upon the particle size distribution of the clinker, the expected air load for normal operation corresponds to about :
a) ~90 kg/m2/min for 1st/2nd part of Grate-I c) ~45 kg/m2/min for 1st Sealing Air Fan e) ~55 kg/m2/min for Grate-II
b) ~80 kg/m2/min for 3rd part of Grate-I d) ~35 kg/m2/min for 2nd Sealing Air Fan f) ~50 kg/m2/min for Grate-III
2. Minimum air flow rates are about 85% of the normal flow rates.
400 400 0 0 0 0
K
80 100 0 0 0 0
7.92
1.44
6.48
Kiln Performance & Efficiency
S. Constraint Symbol Unit Formula
NO.
1 Degree of Filling DoF % 3.2 x TPDclk
Deff3 x n x S
mts rpm %
kcal/kg-clk
Temperature Hv
1.11 x A x s
Comb. Air Sp. Heatcomb. gas
kg/kg-fuel 0.29
Hv
Vxs
Nm3/kg-fuel 0.38
kcal/kg-clk %
79 x O2
0.21 x ( 100 - CO2 ) - O2
17 Major Pluging
Problems, if
kcal/kg-clk %
kg/kg-fuel 0.29