Professional Documents
Culture Documents
A 1099 - Flex Current Clamp - ANG PDF
A 1099 - Flex Current Clamp - ANG PDF
A 1099
User Manual
Code No. 20 750 300
Measuring and Regulation Equipment
Manufacturer
Ljubljanska 77, SI 1354 Horjul
Tel.: +386 1 7558 200; Fax: +386 1 7549 226
http://www.metrel.si; E-mail: metrel@metrel.si
6 3
Distributor:
Producer:
METREL d.d.
Ljubljanska cesta 77
SI-1354 Horjul
© 2006 Metrel
Noise 8 mV, ACRMS (30 A), Operating Temperature Range 0 to +70 C (head)
2 mV, ACRMS (300 / 3000 A) 0 to +70 C (electronics)
Frequency Range 10 Hz to 20 kHz (-3 dB) Storage Temperature Range -40 to +105 C (head)
-20 to +85 C (electronics)
Phase Error < 1 º (45 - 65 Hz),
10 º (at 20 kHz) Operating Humidity 15 % to 85 %
(non condensing)
Position Sensitivity 2 % of range (with cable
>25mm from the coupling) Weight 180 g (head), 190 g
(electronics)
External Field 1 % of range (with cable
>200mm from the head)
Temperature Coefficient 0.08 % of reading per C
Power Supply 2 x AA / MN 1500 / LR6
alkaline
Battery Life 200 hours, low battery indicator
Working Voltage 600 V ACRMS or DC
(see Safety Standards section)
4 5