You are on page 1of 3

PRESSURE CALCULATIONS

S.No Description Weight (MT)


1 Required Capacity to be used Jack ram Diameter 40 CM

2 Area of Ram for 2 Jack ( 1257.143 cm2 each jack) 2514.29 CM2

4 Design Load 545 MT

5 Load Increment 20 % of Design load 109 MT

6 Max Ultimate load 2.5 Times (Required Capacity to be used) 1362.5 MT

7 20% of safe load pressure 43.352 Kg/Cm2

8 Max Pressure 541.902 Kg/Cm2

LOAD INCREMENT
Actual Applied
No. of
Increment (%) Pressure Pressure
Increments Load (MT) Load (MT)
(Kg/Cm2) (Kg/Cm2)

1 20% 43.352 109.0 30 71.71

2 40% 86.705 218.0 50 119.51

3 60% 130.057 327.0 80 191.22

4 80% 173.409 436.0 110 262.92

5 100% 216.761 545.0 140 334.63

6 120% 260.114 654.0 160 382.43

7 140% 303.466 763.0 190 501.94

8 160% 346.818 872.0 210 543.00

9 180% 390.170 981.0 240 573.65

10 200% 433.523 1090.0 270 645.35

11 220% 476.875 1199.0 290 693.16

12 240% 520.227 1308.0 320 764.86

13 260% 541.903 1362.5 350 836.57

14 280% 370 884.37


15 300% 410 979.98
Bridge no 87+700/P12/4, working
working Pile Location : Pile Dia : 1200 mm
pile

Date of Pile Testing : 7/16/2019 Date Casting : 2/6/2019

Pile Design Load : 414 MT Pile Test Load : 621.5 MT

PRESSURE in Kg
Date Load in MT Average Settlement Remarks
/ cm2
( mm ) working pile load test brno-87+700/P12/4
7/16/2019 0.00 0 0.000
7/16/2019 82.80 40 0.360 0 100 200 300 400 500 600 700 800
0.000
7/16/2019 165.60 80 0.910
7/16/2019 248.40 130 1.812 1.000
7/16/2019 331.20 170 1.525
7/16/2019 414.00 220 1.715 2.000

7/16/2019 496.80 260 1.897


3.000
7/16/2019 579.60 300 2.027 total
graph
7/16/2019 621.00 330 2.200
4.000
7/16/2019 621.00 330 4.245
5.000

6.000

7.000

8.000
Column D

9.000

10.000

11.000

12.000

13.000

14.000

15.000

16.000

17.000

18.000
A Gross Settlement (A-B) 4.25 mm
B Rebond 3.04 mm
C Net Settlement 1.21 mm

You might also like