You are on page 1of 8

LOAD Vs HEAT RATE Best Achieved Parameters of RGTPP

( 2 x 600 MW RGTPP) Parameter Unit-I Unit-II Station


Desgined Heat Rate
PLF(%) 67.01 2014-15 60.51 2012-13 54.42 2014-15
Load %age
(MW) Turbine HR Unit HR increase in Deemed PLF(%) 100.32 2016-17 96.49 2018-19 93.72 2017-18
heat rate
KJ/KWh Kcal/KWh Aux. Cons. (%) 5.67 2013-14 5.75 2015-16 5.82 2015-16
600 8183 1955 2241 0.00 Sp. Oil Cons. (ml/kwh) 0.282 2014-15 0.460 2018-19 0.389 2014-15
590 8182 1954 2241 0.00 Heat Rate (kcal/kwh) 2375 2013-14 2369 2013-14 2373 2013-14
580 8182 1954 2241 0.00 Sp. Coal (kg/kwh) 0.664 2013-14 0.663 2015-16 0.663 2015-16
570 8184 1955 2241 0.01 Forced Outage (Hrs.) 73:07 2017-18 301:54 2016-17 432:38 2016-17
560 8186 1955 2242 0.04 BTL Outage (hrs) 0:00 2017-18 47:49 2013-14 225:02 2017-18
550 8191 1956 2243 0.09 Total Outages /1000 Running Hrs 1.52 2014-15 2.55 2014-15 1.92 2014-15
540 8196 1958 2245 0.16 Total F.O / 1000 running hrs 0.89 2016-17 0.84 2018-19 0.93 2016-17
530 8203 1959 2247 0.25 Internal F.O /1000 running hrs 0.60 2017-18 0.84 2018-19 0.93 2016-17
520 8212 1961 2249 0.35 Internal F.O except BTL /1000 run 0.44 2016-17 0.24 2016-17 0.35 2016-17
510 8221 1964 2252 0.47 BTL/ 1000 Running Hrs 0.00 2017-18 0.31 2013-14 0.29 2017-18
500 8232 1966 2255 0.60 Total Outage / Running Hrs % 20.83 2014-15 34.01 2012-13 46.55 2014-15
490 8245 1969 2258 0.75 Reserve Outage/Running Hrs % 3.33 2011-12 0.00 2011-12 2.31 2011-12
480 8259 1972 2262 0.92 Total Force/Running Hours % 2.90 2016-17 7.31 2016-7 5.01 2016-17
470 8274 1976 2266 1.10 Internal F.O. /Running Hrs % 1.45 2017-18 7.31 2016-17 5.01 2016-17
460 8290 1980 2270 1.31 Internal F.O.except BTL/Run Hr % 0.19 2016-17 0.30 2016-17 0.25 2016-17
450 8308 1984 2275 1.52 Tube Leakage /Running Hrs% 0.00 2017-18 1.47 2013-14 2.21 2017-18
440 8327 1989 2281 1.76
430 8348 1994 2286 2.01 2018-19 2019-20
420 8370 1999 2292 2.28 Aux. Data ( Upto August, 2019 )
410 8393 2005 2299 2.56 Unit-I Unit-II Station Unit-I Unit-II Station
400 8418 2011 2305 2.86 Generation 805.96 1055.19 1861.15 400.541 485.61 886.151
390 8444 2017 2312 3.18 Total Aux. Cons. 51.388861 61.110179 112.499 30.016911 33.617659 63.63457
380 8471 2023 2320 3.52 ND Aux. Cons. 4.73 3.803 8.533 6.478 3.933 10.411
370 8500 2030 2328 3.87 Aux. including ND (%) 6.38 5.79 6.04 7.49 6.92 7.18
360 8529 2037 2336 4.24 Aux. Cons. Excluding ND (%) 5.79 5.43 5.59 5.88 6.11 6.01
350 8561 2045 2345 4.62 PLF (%) 36.58 47.89 42.24 18.18 22.04 20.11
340 8594 2053 2354 5.02 PUF(%) 78.89 81.34 80.26 72.61 72.33 72.46
330 8628 2061 2363 5.44

320 8664 2069 2373 5.87 Aux. Data


310 8701 2078 2383 6.33 Unit-I Unit-II Station
300 8740 2087 2393 6.79 Generation 1622.709 2229.48 3852.189
Total Aux. Cons. 106.102869 131.292021 237.3949
ND Aux. Cons. 11.671 7.874 19.545
Aux. including ND (%) 6.54 5.89 6.16
Aux. Cons. Excluding ND (%) 5.82 5.54 5.66
2100 PLF(%) 30.87 42.42 36.65
f(x) = 0.001626695 x² − 1.906638108 x + 2512.889071
2050R² = 1 PUF(%) 77.29 78.17 77.8

2000

1950

1900

1850
300 350 400 450 500 550 600 650
PG TEST RESULTS UNIT-I
Kj/KWh Kcal/KWh
15329.4 3662 86.334
15559.3 3717 86.532
15122 3613 87.329
16242 3880 87.229

PG TEST RESULTS UNIT-II


Kj/KWh Kcal/KWh
15560 3717 86.129
15790 3772 86.123
13002.7 3106 85.265
13172.8 3147 85.424
LOAD Vs Design HEAT RATE ( 2 x 600 MW RGTPP)
Desgined Turbine Heat Rate
Load %age increase in
(MW) heat rate
KJ/KWh Kcal/KWh
600 8183 1954 0.00
480 8259 1973 0.93
360 8529 2037 4.23
300 8740 2087 6.80
LOAD Vs HEAT RATE
( 2 x 600 MW
RGTPP)
Desgined Heat Rate
%age
Load
Turbine HR Unit HR increase in
(MW)
heat rate
KJ/KWh Kcal/KWh
600 8183 1955 2241 0.00
590 8182 1954 2241 0.00

580 8182 1954 2241 0.00


570 8184 1955 2241 0.01
560 8186 1955 2242 0.04
550 8191 1956 2243 0.09
540 8196 1958 2245 0.16 2369
530 8203 1959 2247 0.25
520 8212 1961 2249 0.35
510 8221 1964 2252 0.47
500 8232 1966 2255 0.60
490 8245 1969 2258 0.75
480 8259 1972 2262 0.92 2387 0.76527 0.76
470 8274 1976 2266 1.10
460 8290 1980 2270 1.31
450 8308 1984 2275 1.52
440 8327 1989 2281 1.76
430 8348 1994 2286 2.01
420 8370 1999 2292 2.28 2419.433 2.128876 2.12
410 8393 2005 2299 2.56
400 8418 2011 2305 2.86
390 8444 2017 2312 3.18
380 8471 2023 2320 3.52
370 8500 2030 2328 3.87
360 8529 2037 2336 4.24 2466.17 4.101728 4.08
350 8561 2045 2345 4.62
340 8594 2053 2354 5.02
330 8628 2061 2363 5.44
320 8664 2069 2373 5.87
310 8701 2078 2383 6.33
300 8740 2087 2393 6.79 2527.211 6.63

2100
f(x) = 0.001626695 x² − 1.906638108 x + 2512.889071
2050R² = 1
2000
1950
2100
f(x) = 0.001626695 x² − 1.906638108 x + 2512.889071
2050R² = 1
2000
1950
1900
1850
300 350 400 450 500 550 600 650
LOAD Vs Design HEAT RATE ( 2 x 600 MW RGTPP)
Desgined Turbine
Load Heat Rate
(MW) ( Kcal/Kwh)

498 2074
400 2095 1.012536 Desgined Turbine Heat Rate ( Kcal/Kwh)
370 2109 1.68756 0.675

2120
Desgined Turbine Heat
2110 Rate ( Kcal/Kwh)
2100
Polynomial (Desgined
2090 Turbine Heat Rate
( Kcal/Kwh)
2080 )
2070
2060
2050
360 380 400 420 440 460 480 500 520
LOAD Vs HEAT RATE
( 2 x 600 MW RGTPP)
Desgined Heat Rate
%age
Load
(MW) Turbine HR Unit HR increase in
heat rate
KJ/KWh Kcal/KWh
600 8183 1955 2241 0.00
2100
590 8182 1954 2241 0.00 f(x) = 0.001626695119067 x² − 1.9066381
580 8182 1954 2241 0.00 2050 R² = 1
570 8184 1955 2241 0.01
560 8186 1955 2242 0.04 2000
550 8191 1956 2243 0.09
540 8196 1958 2245 0.16 1950
530 8203 1959 2247 0.25
1900
520 8212 1961 2249 0.35
510 8221 1964 2252 0.47 1850
500 8232 1966 2255 0.60 300 350 400 450 500 550
490 8245 1969 2258 0.75
480 8259 1972 2262 0.92
470 8274 1976 2266 1.10
460 8290 1980 2270 1.31
450 8308 1984 2275 1.52
440 8327 1989 2281 1.76
430 8348 1994 2286 2.01
420 8370 1999 2292 2.28
410 8393 2005 2299 2.56
400 8418 2011 2305 2.86
390 8444 2017 2312 3.18
380 8471 2023 2320 3.52
370 8500 2030 2328 3.87
360 8529 2037 2336 4.24
350 8561 2045 2345 4.62
340 8594 2053 2354 5.02
330 8628 2061 2363 5.44
320 8664 2069 2373 5.87
310 8701 2078 2383 6.33
300 8740 2087 2393 6.79
001626695119067 x² − 1.90663810757872 x + 2512.88907132394

0 400 450 500 550 600 650