Professional Documents
Culture Documents
Anchor Bolt Design Is Code LSD
Anchor Bolt Design Is Code LSD
Portion
Considered for
plate design
X (+)
Mx (-)
(+)Mz (-)
Z
t
Bpb
Y1/3 100 mm
Y1
scon T
A B
C
Calculation of bolt along Z- axis
Node No. 964 Load Case 112
Axial force, P 1150
Moment about X-axis, Mx 380
Moment about Z-axis, Mz 15
Horizontal Force along X- axis , Fx 15.6
Horizontal Force along Z- axis , Fz 85
Max Bearing Pressure, smax =P/A+6xMx/(Lbp x Bbp2 ) 2.12
Min Bearing Pressure, smin =P/A-6xMx/(Lbp x Bbp2 ) -0.52
Dia of bolt 40
Gross area provided 1257
Net area provided 1006
Tensile capacity of each bolt based on tensile strength 337105
Tensile capacity of each bolt based on concrete break out failure 10872949
So, Effective Tensile capacity 337105
No. of bolt per side 1.00
mm
mm
mm
mm
mm
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
Size is O.K.
B
112
kN
kNm
kNm
kN
kN
N/mm2
N/mm2
mm
mm
mm
kN
mm
mm2
mm2
N
N
N
nos
B
mm
OK
OK
OK
B
OK
B
3.4 Design of Base Plate
3.4.1 Design of Base Plate C1
Portion
Considered for
plate design
X (+)
Mx (-)
(+)Mz (-)
Z
t
Bpb
Y1/3 100 mm
Y1
scon T
A B
C
Calculation of bolt along Z- axis
Node No. 990 Load Case 129
Axial force, P 4503
Moment about X-axis, Mx 514
Moment about Z-axis, Mz 2430
Horizontal Force along X- axis , Fx 600
Horizontal Force along Z- axis , Fz 724
Max Bearing Pressure, smax =P/A+6xMx/(Lbp x Bbp2 ) 11.54
Min Bearing Pressure, smin =P/A-6xMx/(Lbp x Bbp2 ) -5.28
Dia of bolt 40
Gross area provided 1257
Net area provided 1006
Tensile capacity of each bolt based on tensile strength 337105
Tensile capacity of each bolt based on concrete break out failure 10872949
So, Effective Tensile capacity 337105
No. of bolt per side 4.00
The stiffner palte is first checked against local buckling assuming a 25 mm thick
stiffner palte
Fy 325 N/mm2 Ts 25 mm
Gusset outstand
Outstand length 200 mm
D/Ts 8< 11.93
Average height of the stiffner plate should be less than 298.20 mm
mm
mm
mm
mm
mm
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
Size is O.K.
B
129
kN
kNm
kNm
kN
kN
N/mm2
N/mm2
mm
mm
mm
kN
mm
mm2
mm2
N
N
N
nos
B
OK
OK
OK
B
OK
B
3.4 Design of Base Plate
3.4.1 Design of Base Plate C1
Portion
Considered for
plate design
X (+)
Mx (-)
(+)Mz (-)
Z
t
Bpb
Y1/3 100 mm
Y1
scon
T
A B
C
Calculation of bolt along X- axis
Node No. 983 Load Case 129
Axial force, P 4076
Moment about X-axis, Mx 1657
Moment about Z-axis, Mz 12
Horizontal Force along X- axis , Fx 10
Horizontal Force along Z- axis , Fz 412
Max Bearing Pressure, smax =P/A+6xMx/(Lbp x Bbp2 ) 8.57
Min Bearing Pressure, smin =P/A-6xMx/(Lbp x Bbp2 ) -2.91
Dia of bolt 40
Gross area provided 1257
Net area provided 1006
Tensile capacity of each bolt based on tensile strength 337105
Tensile capacity of each bolt based on concrete break out failure 3632593
So, Effective Tensile capacity 337105
No. of bolt per side 2.00
The stiffner palte is first checked against local buckling assuming a 25 mm thick
stiffner palte
Fy 325 N/mm2 Ts 25 mm
Gusset outstand
Outstand length 200 mm
D/Ts 8< 11.93
Average height of the stiffner plate should be less than 298.20 mm
mm
mm
mm
mm
mm
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
Size is O.K.
B
129
kN
kNm
kNm
kN
kN
N/mm2
N/mm2
mm
mm
mm
kN
mm
mm2
mm2
N
N
N
nos
B
OK
OK
OK
B
OK
B
3.4 Design of Base Plate
3.4.1 Design of Base Plate C1
Portion
Considered for
plate design
X (+)
Mx (-)
Mz (-)
Z (+)
Dia of bolt 40
Gross area provided 1257
Net area provided 1006
Tensile capacity of each bolt based on tensile strength 337105
Tensile capacity of each bolt based on concrete break out failure 9687500
So, Effective Tensile capacity of each bolt 337105
mm
mm
mm
mm
mm
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
Size is O.K.
B
129
kN
kNm
kNm
kN
kN
N/mm2
N/mm2
nos
N
N
N
mm
mm2
mm2
N
N
N
satisfied
OK
B
OK
OK
OK
B
3.4 Design of Base Plate
3.4.1 Design of Base Plate C1
Portion
Considered for
plate design
X (+)
Mx (-)
(+)Mz (-)
Z
DESIGN OF BOLT
P
P
Mz
t
Bpb
Y1/3 100 mm
Y1
scon T
A B
C
Calculation of bolt along Z- axis
Node No. 990 Load Case 128
Axial force, P 1491.1
Moment about X-axis, Mx -2.4
Moment about Z-axis, Mz 1196.3
Horizontal Force along X- axis , Fx 260.5
Horizontal Force along Z- axis , Fz 0.8
Max Bearing Pressure, smax =P/A+6xMx/(Lbp x Bbp2 ) 5.24
Min Bearing Pressure, smin =P/A-6xMx/(Lbp x Bbp2 ) -2.88
Dia of bolt 40
Gross area provided 1257
Net area provided 1006
Tensile capacity of each bolt based on tensile strength 337105
Tensile capacity of each bolt based on concrete break out failure 4059698
So, Effective Tensile capacity 337105
No. of bolt per side 2.00
LENGTH OF BOLT
Length of bolt provided 1400
mm
mm
mm
mm
mm
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
Size is O.K.
B
128
kN
kNm
kNm
kN
kN
N/mm2
N/mm2
mm
mm
mm
kN
mm
mm2
mm2
N
N
N
nos
mm
OK
OK
OK
B
OK
B
3.4 Design of Base Plate
3.4.1 Design of Base Plate C1
Portion
Considered for
plate design
X (+)
Mx (-)
(+)Mz (-)
Z
t
Bpb
Y1/3 100 mm
Y1
scon T
A B
C
Calculation of bolt along Z- axis
Node No. 990 Load Case 128
Axial force, P 1150.0
Moment about X-axis, Mx 380.0
Moment about Z-axis, Mz 15.0
Horizontal Force along X- axis , Fx 15.0
Horizontal Force along Z- axis , Fz -85.0
Max Bearing Pressure, smax =P/A+6xMx/(Lbp x Bbp2 ) 2.21
Min Bearing Pressure, smin =P/A-6xMx/(Lbp x Bbp2 ) -0.39
Dia of bolt 40
Gross area provided 1257
Net area provided 1006
Tensile capacity of each bolt based on tensile strength 337105
Tensile capacity of each bolt based on concrete break out failure 4059698
So, Effective Tensile capacity 337105
No. of bolt per side 1.00
mm
mm
mm
mm
mm
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
Size is O.K.
B
128
kN
kNm
kNm
kN
kN
N/mm2
N/mm2
mm
mm
mm
kN
mm
mm2
mm2
N
N
N
nos
B
mm
OK
OK
OK
B
OK
B
Sheet
REV
Design of Anchor Bolt PART1 1
elow
Effective
Shear
(Fi)
(kN)
A
A
A
A