Over all screened, unarmoured, multicore 70/90/1050C RJ 0301

Product Description: Make Up:


Generally used within industrial process manufacturing plants for qTinned copper inner conductor
communication, data and voice transmission signals and services, qPVC Compound insulation
typically within the chemical and petrochemical industries. qOuter sheathing to use, colour coded, PVC, HR, FR, FRLS,
ZHFR, insulated
qCores twisted in layers
qOverall Aluminum/Polyester Foil overlapped, Foil Facing
Outward
qDrain wire: 0.5mm2 tinned copper

Application: qMinimum bending radius


8 x diameter
qInstrumentation System
qPower Limited Tray Cable qRated voltage
Core/core: 500 V
Approvals: Core/screen: 300 V
qTest voltage
4000 V (Spark Test)
1000 V (Dielectric Strength)
qFRLS/Flame Properties
Product features: Oxygen Index as per ASTM D 2863
qFlame retardant, Low smoke, Zero halogen Temperature Index as per ASTM D 2863
Smoke Density Rating as per ASTM D 2843
Colour Codes: HCL Acid Gas Generation as per IEC 754/Pt-1
qAs per BS 5308 Part-2 Flammability Test as per IEEE-383
Swedish Chimney Test as per SEN-SS4241475
Technical Data: Thermal Stability as per IS:10810 Pt. 60
qZHFR Properties(on sheath)
qBased on
Corrosivity of gases evolved during combustion pH &
BS 5308 Part-2
conductivity as per IEC-60754-2
qSpecific insulation resistance
> 20 G Ohm x cm qRange of temperature
qConductor stranding Normal Working Temp.: -20°C up to +70°C
Fine wire in accordance to VDE 0295 Class 5 / IEC High Working Temp.: -20°C up to +90°C/105°C
60228 Class 5 Cold application Temp upto -55°C
Part number 2
Number of Cores and mm per Outer diameter in mm Weight
conductor approx. kg/km approx.
RJ 0301
0301 00102 2 X 0.5 6.4 60
0301 00103 3 X 0.5 6.7 72
0301 00104 4 X 0.5 7.3 80
0301 00106 6 X 0.5 8.7 110
0301 00010 10 X 0.5 11.3 176
0301 00120 20 X 0.5 14.3 310
0301 00140 40 X 0.5 19.5 568
0301 00202 2 X 0.75 6.7 75
0301 00203 3 X 0.75 7.1 90
0301 00204 4 X 0.75 7.7 100
0301 00206 6 X 0.75 9.3 138
0301 00210 10 X 0.75 12.1 220
0301 00220 20 X 0.75 15.4 388
0301 00240 40 X 0.75 21.1 710
0301 00302 2 X 1.5 7.7 103
0301 00303 3 X 1.5 8.3 135
0301 00304 4 X 1.5 9.1 150
0301 00306 6 X 1.5 11.1 205
0301 00310 10 X 1.5 14.1 330
0301 00320 20 X 1.5 18.1 580
0301 00340 40 X 1.5 24.0 1065
23
R
Customization
Customization
Customized
Customizedcolour
colouroption
optionand
andprinting
printingofofthe
theouter
outer
INSTRUMENTATION CABLE ( BS 5308 Part 2 ) sheath
sheathon
onrequest
request

Over all screened, unarmoured, Multipairs 70/90/1050C RJ 0302

Product Description: Make Up:


Generally used within industrial process manufacturing plants for qTinned copper inner conductor
communication, data and voice, transmission signals and services, qPVC Compound insulation
typically within the chemical and petrochemical industries. qOuter sheathing to use, colour coded, PVC, HR, FR, FRLS,
ZHFR, insulated
qCores twisted in pairs
qIndividually pair and overall screened with aluminum/
Polyester Foil overlapped
qDrain wire: 0.5mm2 tinned copper
Application: §Minimum bending radius
qAudio, Pulse or RF Signal Transmission 8 x diameter
qComputer or Electronic Peripheral Interconnectors Where High
Levels Of Noise Interference Are Anticipated qRated voltage
qBanking System Core/core: 500 V
Core/screen: 300 V
Approvals: qTest voltage
4000 V (Spark Test)
1000 V (Dielectric Strength)
qFRLS/Flame Properties
Product Features: Oxygen Index as per ASTM D 2863
qFlame retardant, Low smoke, Zero halogen Temperature Index as per ASTM D 2863
Smoke Density Rating as per ASTM D 2843
Colour Codes: HCL Acid Gas Generation as per IEC 754/Pt-1
Flammability Test as per IEEE-383
qAs per BS 5308 Part-2 Swedish Chimney Test as per SEN-SS4241475
Thermal Stability as per IS:10810 Pt. 60
Technical Data:
qBased on qZHFR Properties(on sheath)
Corrosivity of gases evolved during combustion pH & conductivity as
BS 5308 Part-2
per IEC-60754-2
qSpecific insulation resistance
qRange of temperature
> 25 M Ohm x Km
Normal Working Temp.: -20°C up to +70°C
qConductor stranding High Working Temp.: -20°C up to +90°C/105°C
Fine wire in accordance to VDE 0295 Class 5 / IEC Cold application Temp upto -55°C
60228 Class 5
Part number Number of pairs and Outer diameter Weight
mm2 per conductor overall screened O/A
cables in mm screened kg/km
approx.
RJ 0302
0302 00101 1 X 0.5 5.8 50
0302 00102 2 X 0.5 6.6 70
0302 00105 5 X 0.5 12.3 180
0302 00110 10 X 0.5 15.8 300
0302 00120 20 X 0.5 21.7 535
0302 00130 30 X 0.5 26.3 770
0302 00201 1 X 0.75 6.1 60
0302 00202 2 X 0.75 7.0 88
0302 00205 5 X 0.75 13.4 220
0302 00210 10 X 0.75 17.4 390
0302 00220 20 X 0.75 23.9 730
0302 00230 30 X 0.75 28.9 1020
0302 00401 1 X 1.5 7.0 80
0302 00402 2 X 1.5 8.1 130
0302 00405 5 X 1.5 15.6 320
0302 00410 10 X 1.5 20.4 600
0302 00420 20 X 1.5 27.9 1130
0302 00430 30 X 1.5 33.7 1600

24
R
Customization
Customization
Customized
Customizedcolour
colouroption
optionand
andprinting
printingofofthe
theouter
outer
INSTRUMENTATION CABLE ( BS 5308 Part 2 ) sheath
sheathon
onrequest
request

Individual and over all screened, unarmoured, Multipairs 70/90/1050C RJ 0303

Product Description: Make Up:


Generally used within industrial process manufacturing plants for qTinned copper inner conductor
communication, data and voice, transmission signals and services, qPVC Compound insulation
typically within the chemical and petrochemical industries. qOuter sheathing to use, colour coded, PVC, HR, FR, FRLS,
ZHFR, insulated
qCores twisted in pairs
qIndividually pair and overall screened with aluminum/
Polyester Foil overlapped
qDrain wire: 0.5mm2 tinned copper
Application: §Minimum bending radius
qAudio, Pulse or RF Signal Transmission 8 x diameter
qComputer or Electronic Peripheral Interconnectors Where High
Levels Of Noise Interference Are Anticipated qRated voltage
qBanking System Core/core: 500 V
Core/screen: 300 V
Approvals: qTest voltage
4000 V (Spark Test)
1000 V (Dielectric Strength)
qFRLS/Flame Properties
Product Features: Oxygen Index as per ASTM D 2863
qFlame retardant, Low smoke, Zero halogen Temperature Index as per ASTM D 2863
Smoke Density Rating as per ASTM D 2843
Colour Codes: HCL Acid Gas Generation as per IEC 754/Pt-1
Flammability Test as per IEEE-383
qAs per BS 5308 Part-2 Swedish Chimney Test as per SEN-SS4241475
Thermal Stability as per IS:10810 Pt. 60
Technical Data:
qBased on qZHFR Properties(on sheath)
Corrosivity of gases evolved during combustion pH & conductivity as
BS 5308 Part-2
per IEC-60754-2
qSpecific insulation resistance
qRange of temperature
> 25 M Ohm x Km
Normal Working Temp.: -20°C up to +70°C
qConductor stranding High Working Temp.: -20°C up to +90°C/105°C
Fine wire in accordance to VDE 0295 Class 5 / IEC Cold application Temp upto -55°C
60228 Class 5
Part number Number of pairs and Outer diameter Weight
mm2 per conductor individual & overall Individually &
screened cables in over all screened
mm approx. kg/km
RJ 0303
0303 00101 1 X 0.5 6.4 50
0303 00102 2 X 0.5 9.3 100
0303 00105 5 X 0.5 12.6 210
0303 00110 10 X 0.5 17.7 380
0303 00120 20 X 0.5 23.2 700
0303 00130 30 X 0.5 27.6 1000
0303 00201 1 X 0.75 6.7 60
0303 00202 2 X 0.75 10.0 115
0303 00205 5 X 0.75 13.8 255
0303 00210 10 X 0.75 19.4 470
0303 00220 20 X 0.75 25.4 850
0303 00230 30 X 0.75 30.4 1130
0303 00401 1 X 1.5 7.7 80
0303 00402 2 X 1.5 11.8 160
0303 00405 5 X 1.5 16.0 350
0303 00410 10 X 1.5 22.7 670
0303 00420 20 X 1.5 29.8 1230
0303 00430 30 X 1.5 35.7 1800

25
R
Customization
Customized colour option and printing of the outer
INSTRUMENTATION CABLE ( BS 5308 Part 2 ) sheath on request

Over all screened, armoured 90°C/105°C RJ 0304

Product Description: Make Up:


Generally used within industrial process manufacturing plants for qTinned copper inner conductor
communication, data and voice, transmission signals and services, qPVC Compound insulation
typically within the chemical and petrochemical industries.
qCores twisted in pairs
qOuter sheathing to use, colour coded, PVC, HR, FR, FRLS, ZHFR
qOverall screened with Aluminum/Polyester Foil overlapped
2
qDrain wire: 0.5mm tinned copper
qInner sheathing of PVC
qArmour/Shield: G.I. Wire

Application: qRated voltage


Application are as unarmoured cables, but armouring is for Core/core: 500 V
addtion protection, where use is under ground or in ducts. Core/screen: 300 V
qTest voltage
Approvals: 4000 V (Spark Test)
1000 V (Dielectric Strength)
qFRLS/Flame Properties
Oxygen Index as per ASTM D 2863
Temperature Index as per ASTM D 2863
Product Features: Smoke Density Rating as per ASTM D 2843
qFlame retardant, Low smoke, Zero halogen HCL Acid Gas Generation as per IEC 754/Pt-1
Flammability Test as per IEEE-383
Colour Codes:
Swedish Chimney Test as per SEN-SS4241475
qAs per BS 5308 Part 2 Thermal Stability as per IS:10810 Pt. 60

Technical Data: qZHFR Properties(on sheath)


Corrosivity of gases evolved during combustion pH & conductivity as
qBased on per IEC-60754-2
BS 5308 Part-2
qRange of temperature
qSpecific insulation resistance
Normal Working Temp.: -20°C up to +70°C
> 20 G Ohm x cm
High Working Temp.: -20°C up to +90°C/105°C
qConductor stranding Cold application Temp upto -55°C
Fine wire in accordance to VDE 0295 Class 5 / IEC
60228 Class 5
qMinimum bending radius
12 x diameter

26
R

Over all screened, armoured


Part number Number of pairs and mm2 Nominal Dia under Nominal Overall Dia Armour Wire Dia Weight kg/km
per conductor Armour (mm) (mm) (mm) approx.
RJ 0304
0304 00102 2 X 0.5 7.0 11.0 0.9 280
0304 00103 3 X 0.5 9.7 14.0 0.9 390
0304 00104 4 X 0.5 11.0 17.0 1.4 730
0304 00106 6 X 0.5 13.3 19.0 1.4 870
0304 00110 10 X 0.5 15.8 20.6 4x0.8 820
0304 00120 20 X 0.5 21.5 26.8 4x0.8 1250
0304 00140 40 X 0.5 29.5 35.0 4x0.8 1960
0304 00202 2 X 0.75 7.3 12.0 1.4 320
0304 00203 3 X 0.75 10.3 16.0 1.4 560
0304 00204 4 X 0.75 12.3 17.0 1.4 600
0304 00206 6 X 0.75 14.3 19.0 4x0.8 685
0304 00210 10 X 0.75 17.2 22.5 4x0.8 940
0304 00220 20 X 0.75 23.5 28.9 4x0.8 1460
0304 00240 40 X 0.75 32.2 38.2 4x0.8 2120
0304 00402 2 X 1.5 8.5 14.0 1.4 590
0304 00403 3 X 1.5 12.1 17.0 4x0.8 540
0304 00404 4 X 1.5 14.0 19.0 4x0.8 765
0304 00406 6 X 1.5 17.0 22.0 4x0.8 870
0304 00410 10 X 1.5 20.2 26.0 4x0.8 1230
0304 00420 20 X 1.5 27.6 33.0 4x0.8 1985
0304 00440 40 X 1.5 38.2 44.0 4x0.8 2885

27
R
Customization
Customized colour option and printing of the outer
INSTRUMENTATION CABLE ( BS 5308 Part 2 ) sheath on request

Over all screened with Copper braided 90°C/105°C RJ 0305

Product Description: Make Up:


Generally used within industrial process manufacturing plants for qTinned copper inner conductor
communication, data and voice, transmission signals and services, qPVC Compound insulation
typically within the chemical and petrochemical industries.
qCores twisted in pairs
qOuter sheathing to use, colour coded, PVC, HR, FR, FRLS,
ZHFR, insulated
qOverall screened with ATC braid
qDrain wire: 0.5mm2 tinned copper
qArmour/Shield: G.I. Wire/Copper braid

Application: qMinimum bending radius


12 x diameter
Application are as unarmoured cables, but armouring is for
addtion protection, where use is under ground or in ducts. qRated voltage
Core/core: 500 V
Approvals: Core/screen: 300 V
qTest voltage
4000 V (Spark Test)
1000 V (Dielectric Strength)

Product Features: qFRLS/Flame Properties


qFlame retardant, Low smoke, Zero halogen Oxygen Index as per ASTM D 2863
Temperature Index as per ASTM D 2863
Colour Codes: Smoke Density Rating as per ASTM D 2843
qAs per BS 5308 Part 2 HCL Acid Gas Generation as per IEC 754/Pt-1
Flammability Test as per IEEE-383
Technical Data: Swedish Chimney Test as per SEN-SS4241475
Thermal Stability as per IS:10810 Pt. 60
qBased on
BS 5308 Part-2 qZHFR Properties(on sheath)
qSpecific insulation resistance Corrosivity of gases evolved during combustion pH & conductivity as
> 20 G Ohm x cm per IEC-60754-2

qConductor stranding qRange of temperature


Fine wire in accordance to VDE 0295 Class 5 / IEC Normal Working Temp.: -20°C up to +70°C
60228 Class 5 High Working Temp.: -20°C up to +90°C/105°C
Cold application Temp upto -55°C

Part number Number Number of pairs Jacket Copper


of Strands / Strand and mm2 Nom. Thick (mm) Nom. Dia. (mm) index kg/km
dia.(mm) per conductor
RJ 0305
0305 12402 7/0.20 mm 2 X 0.22 0.9 6.2 30.66
0305 12403 7/0.20 mm 3 X 0.22 0.9 8.3 37.38
0305 12404 7/0.20 mm 4 X 0.22 0.9 8.9 44.52
0305 12405 7/0.20 mm 5 X 0.22 0.9 9.8 55.44
0305 12406 7/0.20 mm 6 X 0.22 0.9 10.6 59.64
0305 12407 7/0.20 mm 7 X 0.22 0.9 10.6 63.84
0305 12409 7/0.20 mm 9 X 0.22 0.9 11.8 81.48
0305 12410 7/0.20 mm 10 X 0.22 0.9 12.3 85.68
0305 12412 7/0.20 mm 12 X 0.22 0.9 13.3 94.10
0305 12418 7/0.20 mm 18 X 0.22 1.15 16.2 128.94
0305 12425 7/0.20 mm 25 X 0.22 1.15 19.0 167.58

28
R
Customization
Customization
Customized
Customized colour
colour option
option and
and printing
printing of
of the
the outer
outer
INSTRUMENTATION CABLE (BS 5308 Part 2) sheath
sheathon
onrequest
request

Individual and over all screened, armoured RJ 0306

Product Description: Make Up:


Generally used within industrial process manufacturing plants for qTinned copper inner conductor
communication, data and voice, transmission signals and services,
qPVC Compound insulation
typically within the chemical and petrochemical industries.
qCores twisted in pairs and screened with Al
mylar foil
qOuter sheathing to use, colour coded, PVC, HR, FR, FRLS,
ZHFR, insulated
qOverall screened with Aluminum/Polyester Foil overlapped
qDrain wire: 0.5mm2 tinned copper
qInner sheathing of PVC
qArmour/Shield: G.I. Wire

Application: qMinimum bending radius


Application are as unarmoured cables, but armouring is for 12 x diameter
addtion protection, where use is under ground or in ducts. qRated voltage
Core/core: 500 V
Approvals: Core/screen: 300 V
qTest voltage
4000 V (Spark Test)
1000 V (Dielectric Strength)
qFRLS/Flame Properties
Product Features: Oxygen Index as per ASTM D 2863
qFlame retardant, Low smoke, Zero halogen Temperature Index as per ASTM D 2863
Smoke Density Rating as per ASTM D 2843
Colour Codes: HCL Acid Gas Generation as per IEC 754/Pt-1
qAs per BS 5308 Part 2 Flammability Test as per IEEE-383
Swedish Chimney Test as per SEN-SS4241475
Technical Data: Thermal Stability as per IS:10810 Pt. 60
qBased on qZHFR Properties(on sheath)
BS 5308 Part-2
Corrosivity of gases evolved during combustion pH & conductivity as
qSpecific insulation resistance per IEC-60754-2
> 20 G Ohm x cm
qRange of temperature
qConductor stranding Normal Working Temp.: -20°C up to +70°C
Fine wire in accordance to VDE 0295 Class 5 / IEC High Working Temp.: -20°C up to +90°C/105°C
60228 Class 5 Cold application Temp upto -55°C

29
R

Individual and over all screened, armoured


Part number Number of pairs and mm2 Nominal Dia under Nominal Overall Dia Armour Wire Dia Weight kg/km
per conductor Armour (mm) (mm) (mm) approx.
RJ 0306
0306 00101 1 X 0.5 6.0 10.8 0.9 255
0306 00102 2 X 0.5 9.3 14.7 1.4 500
0306 00105 5 X 0.5 12.6 17.3 4x0.8 610
0306 00110 10 X 0.5 17.4 22.3 4x0.8 950
0306 00120 20 X 0.5 23.2 28.5 4x0.8 1560
0306 00130 30 X 0.5 27.5 33.3 4x0.8 2000
0306 00201 1 X 0.75 6.5 11.1 0.9 290
0306 00202 2 X 0.75 10.0 16.0 1.4 560
0306 00205 5 X 0.75 13.8 19.2 4x0.8 730
0306 00210 10 X 0.75 19.4 24.7 4x0.8 1150
0306 00220 20 X 0.75 25.3 30.7 4x0.8 1750
0306 00230 30 X 0.75 30.3 36.9 4x0.8 2300
0306 00401 1 X 1.5 7.5 12.3 0.9 405
0306 00402 2 X 1.5 11.7 17.0 1.4 535
0306 00405 5 X 1.5 16.0 21.5 4x0.8 900
0306 00410 10 X 1.5 22.7 27.8 4x0.8 1500
0306 00420 20 X 1.5 29.8 35.1 4x0.8 2360

30
R
Customization
Customization
Customized
Customized colour
colour option
option and
and printing
printing of
of the
the outer
outer
INSTRUMENTATION CABLE (BS 5308 Part 2) sheath
sheathon
onrequest
request

Individual and over all screened, armoured with Copper braid shielded RJ 0307

Product Description: Make Up:


Generally used within industrial process manufacturing plants for qTinned copper inner conductor
communication, data and voice, transmission signals and services,
qPVC Compound insulation
typically within the chemical and petrochemical industries.
qCores twisted in pairs
qOuter sheathing to use, colour coded, PVC, HR, FR, FRLS,
ZHFR, insulated
qOverall screened with ATC braid
qDrain wire: 0.5mm2 tinned copper
qArmour/Shield: G.I. Wire/Copper braid

Application: qRated voltage


Core/core: 500 V
qDifferent BUS Interface systems
Core/screen: 300 V
qCAD/CAM Applications
qTest voltage
Approvals: 4000 V (Spark Test)
1000 V (Dielectric Strength)
qFRLS/Flame Properties
Oxygen Index as per ASTM D 2863
Product Features: Temperature Index as per ASTM D 2863
qFlame retardant, Low smoke, Zero halogen Smoke Density Rating as per ASTM D 2843
HCL Acid Gas Generation as per IEC 754/Pt-1
Colour Codes: Flammability Test as per IEEE-383
qAs per BS 5308 Part-2 Swedish Chimney Test as per SEN-SS4241475
Thermal Stability as per IS:10810 Pt. 60
Technical Data: qZHFR Properties(on sheath)
qBased on Corrosivity of gases evolved during combustion pH & conductivity as
BS 5308 Part-2 per IEC-60754-2
qSpecific insulation resistance qRange of temperature
> 20 G Ohm x cm Normal Working Temp.: -20°C up to +70°C
qConductor stranding High Working Temp.: -20°C up to +90°C/105°C
Cold application Temp upto -55°C
Fine wire in accordance to VDE 0295 Class 5 / IEC
60228 Class 5
qMinimum bending radius
12 x diameter

31
R

Individual and over all screened with Copper braid shielded


Part number Number Number of pairs Jacket Copper
of Strands / Strand and mm2 Nom. Thick (mm) Nom. Dia. (mm) index kg/km
dia.(mm) per conductor

RJ 0307
0307 12402 7/0.20 mm 2 X 0.22 1.14 8.70 39.48
0307 12403 7/0.20 mm 3 X 0.22 1.14 9.10 47.88
0307 12404 7/0.20 mm 4 X 0.22 1.14 9.80 66.00
0307 12405 7/0.20 mm 5 X 0.22 1.14 10.40 72.24
0307 12406 7/0.20 mm 6 X 0.22 1.14 11.30 78.54
0307 12407 7/0.20 mm 7 X 0.22 1.14 11.30 84.84
0307 12408 7/0.20 mm 8 X 0.22 1.14 12.10 102.48
0307 12410 7/0.20 mm 10 X 0.22 1.14 14.80 115.10
0307 12415 7/0.20 mm 15 X 0.22 1.52 16.80 158.34
0307 12418 7/0.20 mm 18 X 0.22 1.52 17.40 177.24
0307 12425 7/0.20 mm 25 X 0.22 1.52 20.80 232.68