You are on page 1of 1

SALES: 1800 800 878

SERVICE & HIRE: 1800 802 697


EMAIL: info@capsaust.com.au

CONVERSION CHART Electric & Diesel Compressors


Generators
FLOWRATE CONVERSION CHART
Blowers
TO CONVERT
l/sec 0.472
Air Treatment
cfm m3/min 0.0283
Air Receivers
m3/hour 1.699
cfm 2.119 Gas Generation
l/Sec m3/min 0.06

to
m3/hour
Multiply By
0.001 Air Tools
cfm 35.315
m3/min l/sec 16.667 Hoists & Winches
m3/hour 60
cfm 0.589 Energy Efficiency Services
m3/hour l/sec 0.278
m3/min 0.0167
Aftermarket (Parts & Servicing)

PRESSURE CONVERSION CHART

TO CONVERT
kPa 6.895
psi bar 0.069 CONVERT kWh ELECTRICITY TO CO2 kg /pa
Atmospheres 0.068 Formula - kWh x hours run p/a x Relevant state CO2 multiplier
bar 0.01 INDIVIDUAL STATE CO2 MULTIPLIER CHART
kPa Atmospheres 0.0098 NSW / ACT 1.07
psi 0.145 VIC 1.37
to Multiply By
kPa 100 QLD 1.02
bar Atmospheres 0.987 SA 0.85
psi 14.504 WA 0.93
kPa 101.3 TAS 0.35
Atmospheres bar 1.013 NT 0.77
psi 14.7 Data from Department of Climate Change & Energy Efficiency

ENERGY SAVINGS AVAILABLE VIA PRESSURE REDUCTION


Energy Savings = 8% kW rating x pressure reduction x operating hours
EXAMPLE 1:
Reducing the system pressure on a 100 Kw air compressor from 8 bar to 7 bar operating for 8000 hours per year
Energy Savings = 0.08 x 110 KW x 1 Bar x 8000
= 70,400 kWh per year
$7,040 (@ $0.1/kWh)
*Reducing compressed air supply pressure by 50 kPa = 4% reduction in power usage

AIR LEAKAGE, WASTED ENERGY AND COST FOR EQUIVALENT HOLE DIAMETER

EQUIVALENT HOLE QUANTITY OF AIR ANNUAL ENERGY ANNUAL COST OF


DIAMETER (mm) LOST IN LEAKS (l/s) WASTE (kWh) LEAKS ($ AUD)
1.6 3.2 2,128 $213
3.2 12.8 8,512 $851
6.4 51.2 34,040 $3,404
12.7 204.8 136,192 $13,619

www.capsaustralia.com.au