You are on page 1of 1

Door Schedule and Window Schedule for the Proposed Kindergarten NOTES

Architectural
Window Schedule
1. All dimensions are in milimetres unless
otherwise specified.
2. All dimensions should be checked on site
and any discrepancies be reported to the
architect before work commences.
3. All works to be carried out in accordance
W1 W2 W3 W4 W5 W6 W7 with the local authority regulations.
4. Use figured dimensions only, do not scale
the drawing.
5. walls below 200mm thick to be reinforced
Description Description Description Description Description Description Description with hoop iron at every alternate course.
1500mm wide Steel 1200mm wide Steel 600mm wide Steel 600mm wide Blockwall 2700mm wide Alluminium 2100mm wide Steel Casement 2100mm wide Alluminium 6. DPC to be laid under all walls and to be
Casement Window Casement Window Casement Window Window Casement Window Window Casement Window min. 150mm above finished floor level.
7. All drainage pipes passing under building
W x H = 1500 x 2000mm W x H = 1200 x 1500mm W x H = 600 x 600mm W x H = 1500 x 2000mm W x H =2700 x 2000mm W x H =2100 x 2000mm W x H =2100 x 1200mm and drive way to be encased with 150mm
thick concrete sorround.
Level = 500 Level = 1000 Level = 1000 Level = 1000 Level = 500 Level = 500 Level = 1200
8. All inspection Chambers (IC) in driveways
to heavy duty covershave.
Quantity= 53 Quantity= 34 Quantity= 64 Quantity= 2 Quantity= 1 Quantity= 8 Quantity= 6
9. All reinforced concrete works is to be in
accordance with structural engineer's detail.
10. 500 gauge polythene dpm (damp proof
membrane) and anti-termite treatment to be
provided under ground floor concrete slab.
11. Foundation depth to be determined on
site as per engineer's instructions.
12. Permanent Ventilation (pv) to be
provided on all openings as indicated on
plans.
W8 W9 W10 W11 W12 W13 W14 Civil Works
1. All soils under slabs and around external
foundations to treated for termite control.
Description Description Description Description Description Description Description Description
Description 2. All soils on cut embarkments to be
1500mm wide Steel 2100mm wide Steel 1500mm wide Steel 1500mm wide Steel 1500mm wide Steel 1500mm wide Steel 1500mm wide Alluminium 1500mm wide Steel
1500mm wide Steel stabilised. Slope not to exceed the natural
Casement Window Casement Window Casement Window Casement Window Casement Window Casement Window Casement Sliding Window Casement Window
Casement Window angle of repose.
3. All slabs at ground level to be poured
W x H = 2100 x 1900mm W x H = 2100 x 1900mm W x H = 1500 x 1200mm W x H = 1500 x 2000mm W x H = 1500 x 1200mm W x H = 1250 x 1500mm W x H = 1500 x 1500mm W x H = 2100 x 2000mm
W x H = 2100 x 2000mm
over 1000 gauge polythene sheeting on
Level = 600 Level = 600 Level = 1200 Level = 500 Level = 1200 Level = 1000 Level = 1000 Level = 1000 50mm stone blinding on hardcore.
Level = 1000 Structural Works
Quantity= 4 Quantity= 4 Quantity= 7 Quantity= 4 Quantity= 22 Quantity= 16 Quantity= 4 Quantity= 1 1. All black cotton soils to be removed from
Quantity= 1 all building plinths. All buildings to be clear
of black cotton soil to a distance of 3m.
Door Schedule
2. All paved surfaces to be clear of black
cotton soil to a distance of 500mm outside
the edge of the surface.
3. Refer to structural Engineer's detail for
all R.C works.

Mechanical Works
1. All sanitary fittings, doors, and windows
to schedules.
2. All plumbing and drainage to comply
with city council's specifications.
D1 D2 D3 D4 D5 D6 3. All service ducts to be accessible from
every floor.
4. SVP denotes soil vent pipe to be
Description Description Description Description Description Description provided at the head of drainage.
1500mm wide double Leaf panelled 1500mm wide double leaf panelled 1200mm wide Single Leaf Solid 900mm wide Single Leaf Semi- 900mm wide Single Leaf pannelled 900mm wide Single Leaf semi solid
door with transom. door core Flush door. solid core Flush door. door. core flush door
REVISIONS
W x H = 1500 x 2400mm DATES REMARKS SIGN
W x H = 1500 x 2100mm W x H = 1200 x 2100mm W x H = 900 x 2100mm W x H = 900 x 2400mm W x H = 900 x 2400mm

Quantity= 10 Quantity= 5 Quantity= 37 Quantity= 32 Quantity= 6 Quantity= 8

Project Title
Proposed Kindergarten

Job No
PK/UoN/2015
D7 D8 D9 Scale 1:100

D10 Drawing Title


Description Description Description Doors and Window Schedule
1500mm wide double leaf glazed Sliding 1200mm wide single leaf glazed Sliding 2100mm wide double leaf glazed Sliding Description Drawing No
05/PK/UoN/2015
door alluminium casement. door alluminium casement. door alluminium casement. 2100mm wide single leaf glazed alluminium
casement with one sidelight glass panel Drawn By Njenga James-
W x H = 1500 x 2100mm W x H = 1200 x 2100mm W x H = 2100 x 2100mm B76/3607/2011
Checked By
W x H = 2100 x 2100mm Arch Ralwala
Quantity= 10 Quantity= 13 Quantity= 3
Date
Quantity= 1 10/03/2015

GSPublisherEngine 0.12.100.100