You are on page 1of 1

A B C D A B C D

8.8500 8.8500
3.5000 2.6750 2.6750 3.5000 2.6750 2.6750

1 1 ACU REF

DINING KITCHEN KITCHEN


5 3
3.0000

3.0000
AREA
R

BEDROOM 2 BEDROOM 2 4
S S DINING
2 2 AREA
2.2000

2.2000
8.7250

8.7250

8.7250

8.7250
S S₂
T&B GFCI T&B

3 S
3
2
BEDROOM 1 1 BEDROOM 1
3.5250

3.5250
S

LIVING LIVING
AREA AREA

4 4
LIGHTING LAYOUT POWER LAYOUT
SCALE 1:100 MTS. SCALE 1:100 MTS.

GENERAL NOTES AND SPECIFICATIONS 4. THE ELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE 9. TYPE OF LIGHTING FIXTURE SHALL BE SUBMITTED TO THE
SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER ENGINEER OR ARCHITECT FOR APPROVAL.
1. ALL ELECTRICAL WORKS TO BE UNDERTAKEN SHALL BE IN OR MASTER ELECTRICIAN AUTHORIZED FOR EACH GRADE. 10. MOUNTING HEIGHT
ACCORDANCE WITH THE LATEST EDITION OF THE
5. THE MINIMUM SIZE OF WIRE SHALL BE NUMBER 2.0mmØ 1. SWITCHES-1400 MM FROM FINISH FLOOR LINE.
PHILIPPINE ELECTRICAL CODE PART 1 AND 2 AND THE
COPPER, THHN TYPE UNLESS OTHERWISE NOTED. 2. CONVENIENCE OUTLET-300 MM FROM FINISH FLOOR LINE.
RULES AND REGULATIONS OF LOCAL ENFORCING UTILITY
3. CONVENIENCE OUTLET (COUNTER)-300 MM. ABOVE COUNTER.
POWER AND TELEPHONE COMPANY. 6. WIRING METHOD SHALL BE PVC FOR ALL BRANCH CIRCUITS
AND RSC FOR SERVICE ENTRANCE. 4. REFRIGERATOR/ACU/RANGE OUTLET-300 MM FROM FINISH
2. ALL MATERIALS AND EQUIPMENT TO BE USED SHALL BE FLOOR LINE.
7. PROPER GROUNDING OR ELECTRICAL EQUIPMENT SHALL BE
NEW AND APPROVED TYPE FOR BOTH LOCATION AND 5. CIRCUIT BREAKER-1500 MM FROM FINISH FLOOR LINE.
IN ACCORDANCE WITH THE PHILIPPINE ELECTRICAL CODE.
PURPOSES. 6. METER CENTER-SUBMIT SHOP DRAWING FOR APPROVAL.
8. FIELD VERIFICATION SHALL BE DONE BY THE CONTRACTOR
3. THERE SHALL BE ONLY ONE SERVICE DROP IN A BUILDING ANY DISCRIPANCIES OR CHANGES SHALL BE PROMPTLY
230 VOLTS, 3 WIRE, 1 PHASE, 60 CYCLE. NOTIFIED TO THE OWNER'S REPRESENTATIVE OR DESIGNER.

TEAÑO, JOAN D. ELECTRICAL PLAN DECEMBER 21, 2020

201810394 BSCE 3-2 PROPOSED ONE-STOREY HOUSE ENGR. RONALD P. PEÑA


E-1