SCHEDULE OF LOADS RISER DIAGRAM LEGEND AND SYMBOLS

1 Ø, 2 WIRE, 230 V, 60HZ SYMBOL ITEM DESCRIPTION

2-14 MM² THHN M


IN 32 MM Ø PVC CONDUIT
M SERVICE ENTRANCE

-
2P, 80AT
- MAIN
MCCB
-

-
2P, 20AT 2P, 20AT
L.O. 1 2 L.O.
-

- 2P, 20AT 2P, 20AT


-
L.O. 3 4 C.O. REF

ACU
2P, 20AT 2P, 20AT
C.O. 5 6 C.O.
TOTAL 4 3TOTAL PHASE DEMAND LOAD (ØTDVA)

2P, 30AT 2P, 20AT


RANGE 7 8 REF
LARGEST MOTOR DATA

HP FLA LRA PHASE 2P, 20AT 2P, 20AT


ACU 9 10 SPARE

GND #
A B C D E F A B C D E F

8.50 8.50

4.25 4.25 4.25 4.25

1.00 3.25 1.00 1.25 3.00 1.00 1.00 3.25 1.00 1.25 3.00 1.00
SPECIFICATIONS:
1. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH
THE RULES AND REGULATIONS OF THE LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE AND WITH THE LOCAL UTILITY POWER COMPANY.
0.90

0.90
1 1 2. ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE TO THE
LOCATION.
1.50

1.50
2.00

2.00
3. MINIMUM SIZE OF WIRE SHALL BE 3.5mm² THHN AND 20 mmØ PVC SERIES 1000
ELECTRICAL PIPE OR UNLESS SPECIFIED.
4.00

4.00
7
4. MOUNTING HEIGHT OF DEVICES APPROVED BY ENGINEER IN CHARGE AS
2.50

2.50
1.50

1.50
8
3
R
FOLLOWS:
1.92

1.92
2 2
REF
PANEL BOARD-1.80 m. ABOVE FLOOR LINE
SWITCHES-1.40 m. ABOVE FLOOR LINE
CONVENIENCE OUTLET-0.30 m. ABOVE FLOOR LINE
3.00

3.00
6

5. WHENEVER REQUIRED AND NECESSARY, PULL BOXES AND JUNCTION


12.00

12.00
4.00

4.00

4.00

4.00
1
BOXES OF PROPER SIZE SHALL BE INSTALLED ALTHOUGH SUCH BOXES
PB1

PB1
ARE NOT SHOWN ON THE PLANS.
13.50

13.50

2
1.50

1.50
6. ALL WORKS SHALL BE DONE UNDER THE SUPERVISION OF A DULY
4
LICENSED ELECTRICAL ENGINEER OR REGISTERED MASTER ELECTRICIAN.
3 3
9 A.C.U 7. ALL REVISION OR ADDITONAL WORKS ON ELECTRICAL PLANS SHOULD BE
CONSULTED TO THE DESIGNER (P.E.E.)

8. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF


4.00

4.00

4.00

4.00

4.00

4.00
5
SERVICE ENTRANCE FOR CONNECTION TO POWER COMPANY SERVICE POINT.
4 4
9. ALL WIRING SHALL BE INSTALLED IN STANDARD MOLDFLEX OR PVC ELECTRICAL
CONDUITS RUN EMBEDDED INSIDE THE CONCRETE AND HOLLOW BLOCK
5 5 STRUCTURES, SLABS, COLUMNS, WALLS, PARTITIONS AND INSIDE THE CEILING
SPACES. WHERE THE USE OF CONCEALED CONDUIT WIRING IS IMPRACTICABLE
1.50

1.50

1.50

1.50
SURFACE METAL, PVC MOULDING MAY BE USED.

6 6

LIGHTING LAYOUT POWER LAYOUT


SCALE 1:100 MTS SCALE 1:100 MTS

PROJECT TITLE: REMARKS: SHEET CONTENTS: SHEET NO.:


PROJECT NO.:

DESIGNED BY: PROPOSED TWO STOREY RESIDENTIAL BUILDING BP2


PAULO M. MIRABEL
CHECKED BY:
2 6
PTR NO.: LOCATION:

DATE: PLACE: APPROVED: BEGUITO NUEVO, LIBMANAN CAM. SUR