TUBULAR GOODS INSPECTION REPORT N° 1475-4026/09

CUSTOMER: SITEP. Date of inspection: 12-01-2009


Adresse: CENTRE URBAIN NORD BP. 424 1080 TUNIS CEDEX.
Customer purchase order: Contract N° 023/2007.
Work location: EL BORMA.
Type of inspection:
Code Nº Description
A Cleaning.
B Visual Thread Inspection of damaged pin threads or coupling.
C A.P.I. full length drifting.
D Magnetic Particle Inspection (MPI) End Area.
E Electromagnetic Inspection, (EMI) Full length.
F Ultrasonic wall thickness Inspection.
Material
Manufacturer.....................................................................................................................
Casing Tubing Line Pipe Coated Other......................
Inspected to: API: RP5C1/SA5/5B/RP 5B 1/5CT/RP7G Customers standards Other....................
Type of Pipe: Tubing
Pipe O.D: 2 7/8″ Nominal wall thickness: 0,217″ inch
Pipe grade: N80 15% Of nominal wall thickness: 0,032 inch
PipeWt. Lbs/ft: 6,5#
Thread Connection: 8 RD
Range:
Inspection results and identification:
5833 Total lengths inspected.
1609 Total lengths defective threads and coupling identified by red paint near the connection.
2207 Total lengths no drifted identified by red paint band around the defective area.
1237 Total lengths defective body identified by red paint band around the pipe body near the coupling.
780 Total lengths free of surface defects no exceeding 15 % of the nominal wall thickness and identified
by yellow paint band near the coupling.

5833 Total lengths inspected.


1609 Total lengths damaged threads.
2207 Total lengths no drift.
1237 Total lengths pipe body defective.
5053 Total lengths scrapped (HS).
780 Total lengths free of defects (Ready for immediate use) .

TUBOSER INSPECTOR___________________ SITEP SUPERVISOR____________________

8 Rue Elboustan, Route de Tunis Km 2 Sfax 3002 Phone: 74 239 878 Fax:
74 239 893
SUMMARY OF RESULTS

Customer: SITEP Date: 12 / 01 / 2009


Work location: EL BORMA
Purchase Order: Contrat N° 023/2007.
Tuboser inspector: Mohamed Herchi.
Supervisor: Company: SITEP
Materiel inspected: TUBING 2 7/8″ OD.

Tubing:

OD WEIGHT WALL GRADE RANGE TYPE OF THREADS


2 7/8″ 6,5 # 0,217” N 80 II 8 RD

Inspection results:

TOTAL SONOSCOPE. MPI. FINAL


CLEANING VISUAL INSPECTION API DRIFTING
INSPECTED WALL THICKNESS CLASS
OK Damaged OK D. Threads OK No Drift OK Defective OK

5833 5833 0 4224 1609 2017 2207 780 1237 780

Remarks: ................................................................................................................................
................................................................................................................................................................
................................................................................................................................................................
................................................................................................................................................................
................................................................................................................................................................

Serviced by: _______________________Customer Representative: ______________________

8 Rue Elboustan, Route de Tunis Km 2 Sfax 3002 Phone: 74 239 878 Fax:
74 239 893
DAILY REPORT

Date: 12 / 01 / 2009

Customer:
SITEP
Address:
Centre Urbain Nord BP 424 - 1080 Cedex TUNIS.
Material:
Tubing 2 7/8″ OD.

SUMMARY OF RESULTS:

N Date Total Fileta Calibra Sonoscope MPI Total Total


° inspect ge ge W.Thickness H.S. OK
é

1 / 01 /
1 602 179 225 115 519 83
09
2 / 01 /
2 602 194 199 120 513 89
09
3 / 01 /
3 671 201 275 110 586 85
09
4 / 01 /
4 611 191 216 130 537 74
09
5 / 01 /
5 681 185 287 128 600 81
09
6 6 /01 / 09 611 152 249 126 527 84
7 7 / 01/ 09 716 170 333 128 631 85
8 / 01 /
8 649 189 243 135 567 82
09
11 / 01 /
9 380 98 100 125 323 57
09
1 12/ 01 /
310 50 80 120 250 60
0 09
1
1

8 Rue Elboustan, Route de Tunis Km 2 Sfax 3002 Phone: 74 239 878 Fax:
74 239 893
1
2
1
3
1
4
1
5

Total: 5833 1609 2207 1237 5053 780

Serviced by: _______________________Customer Representative: ______________________