CUSTOMER: Weatherford INSPECTION REPORT

Work location: Weatherford base 2 SPECIFICATION: DS-1 STANDARD CATEGORY 3-5


Report N°: 0503CH18-458 X Visual Inspection connections
W.O N°: X UV Inspection connections
Page: 1 OF 1 X Visual Inspection body
Date: 19 November 2019 X Mag. Particle Insp body
Next inspection due date: 6 months if not use X dimension connections

DESCRIPTION : X OVER REDUCED SECTION Serial Number : 1482811

BOX PIN BODY


Condition Condition Condition
Box Conn SRG/ CONN
B.B/F.B NECK PINOD PIN ID T-S MPI VISUAL
OD Type MPI VISUAL DIM3 API TYPE MPI VISUAL DIM3
len
3
6 18 ½ 6 5/8
B.B 23 ¾ ” 4 ½ IF OK OK OK 8” 1/16 SRG OK OK OK OK OK
1/2” ” REG

INSPECTION RESULT
BOX CONNECTION COND: FREE OF DEFECT ACCEPTED
T.L F.N T.S
NECK TONG SPACE PIN CONNECTION COND: FREE OF DEFECT ACCEPTED
Total Length
(m) length BODY COND : FREE OF DEFECT ACCEPTED
1.11 23 ¾ ” 18 ½ ” X OVER SUB CONDITION: ACCEPTED

Measuring & Test Equipment SN: Cal. date Measuring & Test Equipment SN: Cal. date Magnetic Particle Inspection: CONSOMMABLE
UV Light Meter 1320005430 10 10 2019 Vernier Caliper 6M0030 10 10 2019 Magnetizing Process: Continuous X Residual White contrast paint type : pfinder 280 Batch N°: L1101604

Visible Light Meter 1320005430 10 10 2019 Depth Caliper 0501111030 10 10 2019 Magnetizing Process: DC Coil
X AC Yoke X
Black magnetic ink type : pfinder250 Batch N°: L1101278

Electric Coil 176 10 10 2019 Steel Ruler N-A N-A Dry Wet X Wet fluorescent type : pfinder150 Batch N°: L1101539
MPI Technique: Particle fluorescent 0.4/100ml
AC Yoke 7973 10 10 2019 yoke test weight A 205 10 10 2019 fluorescent X visible X
consontration : black ink 2.4/100ml
Magnetic Field Strength Demagnetization: YES X NO Intensity show before visible Intensity: 1200 LUX
UV Light 180 10 10 2019 MNQ3 10 10 2019 strips
Indicator Field Indicator Type: Ac yoke/ pull 1o lbs: yes inspection Black Intensity: 1000 μ watts/cm2 min

INSPECTOR: KHALIL CHABBOUH CUSTOMER REPRESENTATIVE :