You are on page 1of 5

PILE CAP DESIGN

INPUT DATAS

Fck 30
Fy 500
AXIAL LOAD ON COLUMNS (P) 9044
DIMENSION OF COLUMN ALONG SHORT. DIRN. (a) 500
DIMENSION OF COLUMN ALONG LONG. DIRN. (a1) 1000
DIAMTER OF PILE(D) 800
C/C DISTANCE BETWEEN PILES (L) 2000
EFFECTIVE DEPTH OF PILE CAP(d) 1310
WIDTH OF PILE CAP(b) 900
LENGTH OF PILE CAP(l) 3000

OUTPUT DATAS

PILE CAP STM MODEL WITH 2 ELEMENTS OF COLUMN

DISTANCE B/W LINE OF ACTION OF FORCES (X) 1000


TENSION 3451.9083969466
Ast REQUIRED 7935.421602176
DIAMETER OF BAR 32
No. OF BARS REQUIRED 9.8718919215

BEAM THEORY

DISTANCE OF PILE CENTRE TO FACE OF COLUMN (Dc) 500


BENDING MOMENT (Mu) 2261

PERCENTAGE STEEL 50*fck/fy *(1-sq root (1-4.6*Mu/(fck*b*d2)


Mu/fck bd2 0.0487971218
50*fck/fy 3
sq (1-4.6*Mu/(fck*bd2) 0.8806436508
% STEEL 0.3580690476
Ast REQUIRED 4690.7045241696
DIAMETER OF BAR 32
No. OF BARS REQUIRED 5.835370875
DESIGN FOR ONE WAY SHEAR

SHEAR FORCE 4522


Tv 3.8354537744
SHEAR ENHANCEMENT 2

CHECK FOR LOAD TRANSFER FROM COLUMN TO PILE CAP

AREA OF BASE FOR LOAD TRANSFER, A1 2.7


AREA OF BEARING UNDER COLUMN, A2 0.5
MODIFICATION FACTOR 2.3237900077
THUS MODIFICATION FACTOR 2
CONCRETE BEARING CAPACITY 13500
CONCRETE BEARING CAPACITY >
N/mm2
N/mm2
kN
mm
mm
mm
mm
mm
mm
mm

UMN

mm
kN
mm2
mm

mm
kNm

*(1-sq root (1-4.6*Mu/(fck*b*d2))

mm2
mm
kN
N/mm2
x τc

LE CAP

mm2
mm2
<= 2

kN
P