ANGE Sima Solution for Energy Eo JAI} ronment Engineering To Dhaka May 27, 2017 Me T.Tomi Project Manager ‘Suimizu Corporation ‘YK Bangladesh Pte Ltd. ‘Savar, Dhaka. ‘Sub: Lightning Protection System (LPS) on YKK Bangladesh Pte Ltd. (Factory-2) Ref: Contract for Consultant Services for Design and drawing of LPS on YKK Bangladesh Pte Ltd. (Factory-2) (Job code 23-4, order Dato 13.05.17 PO.No. 298) Dear Sir, Pursuant to the stipulation of the contract under reference we have designed the LPS as per NEPA 780 and Alliance requirements regarding Lightiing System. W any query afise by Allance, ENRG TECH will response and comply their requirements, \We are pleased to submit herewith the design for your kind information. Hope this design full your requirements. Era Ms Yount tan engrr 6) eEAneeue (EED Gren Asoc sce mg younete” Sen ene ee sis igegt nah ett Faomce 12 erqyemgecheagma cor Fa Reo, otice House #20,Rond04.Bockne —_& ww anrgtach.bd-com 28, Te Mansion, Kawran Bszar rea, Rae, Pion fe sin 18 rar rato, Bangles LIGHTNING PROTECTION SYSTEM DESIGN YKK Bangladesh PTE Ltd. (Factory-2) Plot # 89-91, DEPZ (Ext. Area), Ashulia, Savar, Dhaka, Bangladesh. CONSULTANT: ENRG TECH © House-20, Road-04, Block-C, Banasree, Rampura, Dhaka-1219. * INDEX 1. General Information: 0.0.0... ceteseseeeeseneeeeseeteeeseenensneneseesenenenes 01 2 legend oc Risk Index CalculatiO0 12 | 02 Ss Psindms(AB Ce) 03 4 EPS in deis(h eG) 04 5. LPS Layout Drawins (2D! View) 20). 05 G: Isomettic view tor LPS (3D View). 06 —— YKK — PTE Lid. metas — al “BRST | sree — a ‘a ciny2) | Sos a a 00 * General Information for Lighting Protection System (LPS) Installation: 1. LPS Method. 2. Material Class | 3. Type of Roof 4. Building Height = 5. Heighest Structure Height 6. Roof Top Area 7. Total Perimeter 8. Total Air Terminal 9. Total Down Conductor 10. Total Grounding Electrode 11. Air Terminal 12. Roof Conductor Size 13. Down Conductor Size 14. Bonding Conductor Size : Used Conventional LPS Method (NFPA 780 2014 edition & BNBC 2006). : Class-I : Flat Roof : 22.86 mice. 75 ft : 22.86 mie. 75 ft : 4183.33 sm i.e 45029 sft : 258.8 m ie. 849.08 ft : 56 nos. Total Down Conductor = ——— : 9 nos. : 9 nos. "100 ft = 8.49 = 9 nos. : 600 mm or 2 ft Height; 12.7 mm or 1/2 inch dia Al Rod : 50 mm2 Al WIRE (same for both Main & Inter Connected Roof Conductor) : 50mm2 Al WIRE : 35mm2 Al WIRE Note: Aluminium (Al) shall be used as materials for Air Terminal, Down Conductor, Main Roof Conductor & Inter Connected Conductor. a PROSTTTE [Littning Protection system (5) dene ase (Factay-2) aie ae — PROIEETLOEATION Eo aA TLE ew nto | Plot # 89-91, DEPZ (Ext Area), NRG TECH ee: ae Protection YKK Bangladesh PTE Lid. | "ota #81 DEF? em phos coe SSctrorewtEE | 85: nde) ‘“Gomaas” | O1 (Factory-2) fagleiat moeoee ae * Legend | ane yb = “Termin (AD ae | Tot Conc / ae | Earth Pit Torta 5 | Bai Comes = * Risk Index Calculation for Lighting Protection System: (Table: 8.2.12 Art. 2.9, BNBC 2006) | Index | Name Description Factory Ponts | A ‘Use of Structure ‘Small and medium size factories 6 B__| Type of Construction Reinforced concrete with metal roof 3 ©__| Consequential Effects {dst and agricultural buildings with pecially suseepibe contents 5 D Degree of Isolation ‘Structure completely isolated or exceeding at least twice the height of surrounding structures or trees 10 | E ‘Type of Terrain Flat terrain at any level. ea F Height of Structure (18 m~24 m); here the structure is 75 ft ie 22.86 m G Lightning Prevalence Over 21/years : 2 Total isk index igue:| 7 Remarks; As per BNBC if Risk Index figure is around 40 or higher then LPS need to install on the building, So, eed(o install Lightning Protection System. PORTE TE OT EATER CoRR Te aeRO — aE Lighting Protection sytem (UP) Eng Rakin | Shaan LeceN0 8 System (LFS) Pot # 89-91, DEPZ (Ext Area), ENRG TECH BScengroo ese) | Beer EEE) FISKINOEX CALCULATION Design for YK Bangladesh PTE Ld YK Bangladesh PTE Lid Ashulia, Savar, Dhaka, ‘H# 20, R04, BlockiC, FIER 1242 (Fecen.2) (Factory-2) Bangladesh, Bunce aka 21 cesear LIGHTNING PROTECTION SYSTEM IN DETAILS (A, B, C & D) DETAIL-A | aa | BASE PLATE 7 oo ' (950m cdr ELECTRODE CLAMP, WAL ot ‘owns conoucroR 200 madonna, 5 BRASS CLAMP i q NUT BOLT & WASHER - BRASS \ A EARTH ELECTRO | DETAIL-B DETAIL-C PLAN OF AIR TERMINAL DETAIL-D —provecr me: ‘hentai; | prasecrincanoe | conaucraer ovine: (7 tices cnc: a Liat 2 Eng: Real | Ey aa ae Gere Pecan, | ecingao eeus | mgnmerogzeeam| — SWROTEOHS Sect’ sar |izeees | MRE | 93 (Factoy-2) (Factory-2) Bangladesh Banasre, Dnata 129. DATE 0ST [AIR TERMINAL AND EARTHELECTRODE LIGHTNING PROTECTION SYSTEM IN DETAILS (E, F & G) FOR LIGHTNING PROTECTION, (OESIGN' DONE AS NEPA THO 2016) ARTERMIA (sou aLumuny | ETAL ABC a a | | DOWN CONDUCTOR } os NG RAD ‘Somm2 AI WIRE r Nut aa : foron1234567888 | | Copper Part & courncreosou - oe } | { reece pene ee o | LENGTH OF EARTH ELECTRODE SHALL BE AS PeReARTHNG Test Resu.r| Bimetallic Connector a } INSPENTION PIT , EARTH ELECTRODE | Pr Bi | FOR SYSTEM EARTHING resp onouNoLE ‘ Sg | . bli hn rearing : a BIMETALLIC CONNECTOR fe . DETAIL-E | iD boner —_ DETAIL-G | pret mie: I CUENTWAME: PROJECT LOCATION: CONSULTANT [DESIGNED Br: CHECKED BY _ORAWANG TITLE: [am ] LIGHTNING PROTECTION ighihing Protection System (LPS) ‘Engr. Ma. Reza Karim | Engr. Shamaut Huda Sari agaeen rice, | YKK Bangladesh PTE Ld. / OAS) OER7E% Men) te uC Seem | Petar Ssereo | O4 (Factoy-2) | (Factory-2) Bangladesh. Sane, Oba t7. aor ay tf sf fe. =e res ws. } i= 5 RC ROOF dl ld | iL | eS toNe- | = = - = | cs zs = + (a : he: zg | 3 Hew | ll 5 a 2 = | IF t f = t { “) c. | METAL ROOF = = is -t : te 5 | = it | a i ROOF FLOOR PLAN OF YKK FACTORY-02 “= oneTTnE ORTON RTOS Tea nie Ee ighting Protection Systm (5) | ENRG TECH Erg cunnntnie et | Sign forYKK Bangladesh PTE Lia. KK Bangladesh PTE Ltd. ta oa cee eee Bs Engew Sear Pi Sam) | (Factory-2) (Factory-2) Bangladesh. Banasoe, Dhaka 1218. DATE ROT | ET-8 (Tomaiic View oF igmning Provsaion Swen] ET-3 Note: All dimensions in this drawing are in Meter. [vere cata aT STE Soa ae Lighting rtcton os Tent enloe ing Protection System (LPS) YKK Bangladesh PTE Ltd. eased Area), ieiiaioeivale BE ogra Protection System (LPS) 06 ' Sousee tate wan JDesig for vkx Bangladesh PTE Lid (Factory-2) (Factory-2) Bangladesh,

You might also like