1.Specification
Model KN-35D
GN3VBAC ( An official approval organization :Japan Gas
Type
Appliances Inspection Association)
Gas detection method Catalytic combustion type
Target gas City gas(For lighter than air)
Alarm level Less than 1/4 of lower explosive limit(LEL)
Red lamp light with Intermittent buzzer sound
Alarming method
(Buzzer sound is about 20 seconds delay),(automatic reset)
Initial alarm About 40 seconds(Red ramp light)
prevention time
lent, or disclosed in any way whatsoever for the use of any third party,
External Kind
(Load resistance range:1.2kΩ~50kΩ)
Output
delay time 0 second
Method of the installation Ceiling or Wall installation by exclusive installation base
KM-35B
Outer Dimension H110mm×W110mm×D42mm
Weight Approx.140g
Additional function Drift detection of sensor (Continuous buzzer sound),
Check function
Accessories Test Gas(×1)
CHECKED
T.Watanabe
REVISION
FIN24 98 925 1
3
TW-4ME
2.Outline drawing
lent, or disclosed in any way whatsoever for the use of any third party,
nor used for the manufacturing purposes without the express written
Fuji Electric Co., Ltd.. They shall be neither reproduced,copied,
This material and the information herein is the property of
ABS resin
- Housing Color:
Ivory
11 Certificate of inspection
10 Company tablet
9 Expiration date tablet
8 Makeup tablet
7 Check terminal
6 External Output terminal
5 Power supply terminal
4 Gas detection part
3 Buzzer
2 Alarm lamp Red lamp
1 Indication lamp Green lamp
Part Description Remark
CHECKED
T.Watanabe
REVISION
FIN24 98 925 2
3
TW-4ME
3.External output voltage
20
Output Voltage
15
Gas alarm
10
〔DC.V〕
Monitoring
0
1.2 10 30 50
lent, or disclosed in any way whatsoever for the use of any third party,
Load resistance〔kΩ〕
nor used for the manufacturing purposes without the express written
Fuji Electric Co., Ltd.. They shall be neither reproduced,copied,
This material and the information herein is the property of
Output Voltage〔DC.V〕
State (Load resistance1.2kΩ~50kΩ)
Monitoring 6 V(+0V/-1V)
consent of Fuji Electric Co., Ltd..
4.Terminal connection
Check terminal
CHECKED
T.Watanabe
REVISION
FIN24 98 925 3
3
TW-4ME