Specification of FUJI City Gas alarm

KN-35D

1.Specification
Model KN-35D
GN3VBAC ( An official approval organization :Japan Gas
Type
Appliances Inspection Association)
Gas detection method Catalytic combustion type
Target gas City gas(For lighter than air)
Alarm level Less than 1/4 of lower explosive limit(LEL)
Red lamp light with Intermittent buzzer sound
Alarming method
(Buzzer sound is about 20 seconds delay),(automatic reset)
Initial alarm About 40 seconds(Red ramp light)
prevention time
lent, or disclosed in any way whatsoever for the use of any third party,

Power-ON indicator Green lamp light


nor used for the manufacturing purposes without the express written
Fuji Electric Co., Ltd.. They shall be neither reproduced,copied,

Power DC24V(allowable voltage range:DC17V~DC35V)


This material and the information herein is the property of

Power consumption Monitoring:Approx. 1.1W Alarm on:Approx. 1.4W


Temperature range -10℃ ~ +50℃
Humidity range 85%RH or less
6V when monitoring. 0V when power off. 12V when gas alarm.
consent of Fuji Electric Co., Ltd..

External Kind
(Load resistance range:1.2kΩ~50kΩ)
Output
delay time 0 second
Method of the installation Ceiling or Wall installation by exclusive installation base
KM-35B
Outer Dimension H110mm×W110mm×D42mm
Weight Approx.140g
Additional function Drift detection of sensor (Continuous buzzer sound),
Check function
Accessories Test Gas(×1)

DATE NAME APPROVED

DRAWN 2014-01-28 T.Watanabe


T.Kamioka
DWG.No.

CHECKED
T.Watanabe
REVISION
FIN24 98 925 1
3

TW-4ME
2.Outline drawing
lent, or disclosed in any way whatsoever for the use of any third party,
nor used for the manufacturing purposes without the express written
Fuji Electric Co., Ltd.. They shall be neither reproduced,copied,
This material and the information herein is the property of

consent of Fuji Electric Co., Ltd..

ABS resin
- Housing Color:
Ivory
11 Certificate of inspection
10 Company tablet
9 Expiration date tablet
8 Makeup tablet
7 Check terminal
6 External Output terminal
5 Power supply terminal
4 Gas detection part
3 Buzzer
2 Alarm lamp Red lamp
1 Indication lamp Green lamp
Part Description Remark

DATE NAME APPROVED

DRAWN 2014-01-28 T.Watanabe


T.Kamioka
DWG.No.

CHECKED
T.Watanabe
REVISION
FIN24 98 925 2
3

TW-4ME
3.External output voltage

20

Output Voltage
15
Gas alarm

10

〔DC.V〕
Monitoring

0
1.2 10 30 50
lent, or disclosed in any way whatsoever for the use of any third party,

Load resistance〔kΩ〕
nor used for the manufacturing purposes without the express written
Fuji Electric Co., Ltd.. They shall be neither reproduced,copied,
This material and the information herein is the property of

Output Voltage〔DC.V〕
State (Load resistance1.2kΩ~50kΩ)
Monitoring 6 V(+0V/-1V)
consent of Fuji Electric Co., Ltd..

Gas alarm 12 V(+3V/-0V)


Power off 0 V

4.Terminal connection

Power supply terminal


External Output terminal
Nonpolarity

Check terminal

DATE NAME APPROVED

DRAWN 2014-01-28 T.Watanabe


T.Kamioka
DWG.No.

CHECKED
T.Watanabe
REVISION
FIN24 98 925 3