Professional Documents
Culture Documents
POWER SECTION
Provide provision to select four different values of DC voltages.
DC +5 GND
DC +3.3 GND
ACTIVE FILTERS
Second Order Low Pass Filter
Circuit Diagram
1. 2nd order low pass butterwort filter with cut-off frequency 3kHZ.
2. First check the VCC (8th pin) and ground (4th pin) on the IC connector.
3. No other signal should be present.
4. Apply the input signal (sine 1Vp-p with frequency range 100 to 10kHz)
1. 4nd order low pass butterwort filter with cut-off frequency 3kHZ.
2. First check the VCC (8th pin) and ground (4th pin) on the IC connector.
3. No other signal should be present.
4. Apply the input signal (sine 1Vp-p with frequency range 100 to 10kHz)
RESET SWITCH
Reset switch is use to deactivate all the signal including signal generator portion, sampling frequency
and multiplexer and demltiplexer.
CRYSTAL FREQUENCY
This section provide the high frequency = 25MHz .
MANUAL
1. Connect the output of each one of the signal generator block (sine, triangle, square, random
binary sequence) to the input channels (CH1, CH2 for Sine and Triangle, CH3, CH4 for square and
random signal generation) of the multiplexer.
2. Test the PCM modulated output at the test point (P, P2,P3, P4) here, input signal is sampled
with the sampling frequency adjusted by the sampling frequency selection section at different
frequencies.
Output of the demultiplexer is depend on the switch conditions.
S1 S0
0 0 CH1
0 1 CH2
1 0 CH3
1 1 CH4
3. Check the output of the MUX/TDM ENCODER at serial out terminal, Now this only provide the
output which is selected by selection switch.
4. Connect the MUX/TDM ENCODER at serial out terminal to the serial in of the DEMUX/TDM
DECODER.
5. Check the output of the DEMUX/TDM DECODER at the test point (D1,D2, D3, D4) those are give
same output as the signal measured at test point (P1, P2 ,P3 ,P4).
6. Measure the PCM demodulated output at terminal (CH1, CH2, CH3, CH4).
7. Analog output of channel CH1 and CH2 connect to the butterworth filter input(as required
connect to 2nd order or 4th order)
8. Test the output of the filter(that should be approximately same as the input applied to the
CH1_I/P AND CH2_I/P)