Specification
Table of Contents 3
Introduction 7
Wavelength Plan 7
DWDM Wavelengths 7
CWDM Wavelengths 12
Environmental Conditions 13
Module Delay 14
Chapter 1
Introduction
This section provides general information for the use of the Fiber Service Platform (FSP).
It is divided into the following topics:
Wavelength Plan 7
Environmental Conditions 13
Module Delay 14
Wavelength Plan
This section contains the following topics:
DWDM Wavelengths 7
CWDM Wavelengths 12
DWDM Wavelengths
Table 1 and Table 2 are subsets of the ITU-T 694.1 (DWDM) as used by the FSP system.
Table 1 contains the DWDM C-band wavelengths used by the FSP.
Transceivers supporting the 100GHz channel grid in the C Band with 41 channels offer
channel frequencies from 196.00 THz to 192.00 THz.
Transceivers supporting the 50GHz channel grid in the C Band with 81 channels offer
channel frequencies from 196.00 THz to 192.00 THz.
Transceivers supporting the 50GHz channel grid in the C Band with 96 channels offer
channel frequencies from 196.00 THz to 191.25 THz.
Table 2 contains the DWDM L-band wavelengths used by the FSP.
CWDM Wavelengths
Table 3 contains the CWDM wavelengths according to ITU-T 694.2 and channel names
used by the FSP.
1271.00 #C1270
1291.00 #C1290
1311.00 #C1310
1331.00 #C1330
1351.00 #C1350
1371.00 #C1370
1431.00 #C1430
1451.00 #C1450
1471.00 #C1470
1491.00 #C1490
1511.00 #C1510
1531.00 #C1530
1551.00 #C1550
1571.00 #C1570
1591.00 #C1590
1611.00 #C1610
Environmental Conditions
The FSP product family fulfills several environmental conditions (ambient temperatures
and relative humidity levels) for storage, transportation and stationary operation of the
equipment. These environmental conditions are specified in:
• Telcordia GR-63-CORE, Issue 4, April 2012 (Telcordia SR-3580:2012 level 3
(NEBS))
• ETSI EN 300 019-1-1 V2.2.1 (2014-04) Storage Class 1.2
• ETSI EN 300 019-1-2 V2.2.1 (2014-04) Transportation Class 2.2
• ETSI EN 300 019-1-3 V2.4.1 (2014-04) Stationary use at weatherprotected locations
Class 3.1
These minimum and maximum values of temperature and humidity are not met
simultaneously.
All specifications in this document are valid for end of life and over the
whole temperature range if not otherwise stated.
Note
Module Delay
Module delay of a pluggable transceiver is the sum of delays which are caused by the
optical-electrical conversion of the receiver and the electrical-optical conversion of the
transmitter.
Figure 1illustrates the module delay of pluggable transceivers.
Module delay
Optical signal
T Time of delays
Electrical signal required for
loop
Attenuator electrical -optical /
R
optical -electrical
conversion .
1061701400-01 XFP/11G/DCTV/SM/LC
0061701811-03 XFP/11G/1310S/SM/LC
0061701812 XFP/11G/1550L/SM/LC
1061701841-01 XFP/11G/1310S/SM/LC/TIN
1061701842-01 XFP/11G/1550L/SM/LC/TIN
1061701843-01 XFP/11G/1550V/SM/LC/TIN
1061701851-02 SFP+/10G/1310S/SM/LC
1061701855-02 SFP+/10G/850I/MM/LC
0061703805 SFP/4GU/1310S/SM/LC
0061705807 SFP/2G5U/1310L/SM/LC
0061705824 SFP/HS/1310S/SM/LC
0061705844-03 SFP/2G1/850I/MM/LC
1061705850-02 SFP/GBE/1310S/SM/LC/TIN
1061705851-02 SFP/GBE/1310L/SM/LC/TIN
1061705852-02 SFP/GBE/1550V/SM/LC/TIN
1061705854-02 SFP/GBE/850I/MM/LC/TIN
0061705890 SFP/GBE/Electrical/RJ45
1061005858-01 SFP/SOAM/GBE/1310S/SM/LC/TIN
0061705992 SFP/FE/C1490U/SM/LC
0061705993 SFP/FE/C1510U/SM/LC
1061706192 SFP/FE/C1490V/SM/LC
1061706193 SFP/FE/C1510V/SM/LC
XFP/11G/DCTV/SM/LC
The XFP/11G/DCTV/SM/LC is a Multi-Protocol Optical XFP that provides a high speed
serial link at data rates from 9.95 Gbit/s to 11.35 Gbit/s. It is used for bidirectional
communication over single-mode fiber.
The transmitter is fully tunable to any of the C-band channels. Each channel can be tuned
in the system management by using the NE management tools.
It is intended for use in ADVA Optical Networking’s devices with XFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
XFP types approved by ADVA Optical Networking only.
Receiver dynamic range for OSNR > -22 dBm ... -7 dBm
30 dB (0.1 nm)
Receiver dynamic range for OSNR < -20 dBm ... -7 dBm
30 dB (0.1 nm)
Dispersion load range with 1 dB -100 ps/nm ... +300 ps/nm and +1000 ps/nm ...
OSNR penalty +1300 ps/nm
Dispersion load range with 2 dB -400 ps/nm ... -100 ps/nm and
OSNR penalty +1300 ps/nm ... +1500 ps/nm
Dispersion load range with 1 dB -200 ps/nm ... +100 ps/nm and
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -200 ps/nm and
OSNR penalty +1100 ps/nm ... +1400 ps/nm
XFP/11G/CxxxxV/SM/LC
The XFP/11G/CxxxxV/SM/LC is an MSA-compliant pluggable transceiver for 11 Gbit/s
data rates and bidirectional communication over single-mode fiber. It is operating at
CWDM wavelengths according to ITU-T G.694 and it provides monitoring of operating
parameters such as optical input power, temperature or laser bias.
It is intended for use in ADVA Optical Networking’s devices with XFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
XFP types approved by ADVA Optical Networking only.
XFP/11G/CxxxxL/SM/LC
The XFP/11G/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for 11 Gbit/s
data rates and bidirectional communication over single-mode fiber. It is operating at
CWDM wavelengths according to ITU-T G.694.2 and it provides monitoring of operating
parameters such as optical input power, temperature or laser bias.
It is intended for use in ADVA Optical Networking’s devices with XFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
XFP types approved by ADVA Optical Networking only.
XFP/11G/1310S/SM/LC
The XFP/11G/1310S/SM/LC is an MSA-compliant pluggable transceiver for 10 Gbit/s
and 11 Gbit/s data rates and bidirectional communication over single-mode fiber. It is
operating at a wavelength of 1310 nm and it provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in ADVA
Optical Networking’s devices with XFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with XFP types approved by
ADVA Optical Networking only.
XFP/11G/1550L/SM/LC
The XFP/11G/1550L/SM/LC is an MSA-compliant pluggable transceiver for 10 Gbit/s
data rates and bidirectional communication over single-mode fiber. It is operating at a
wavelength of 1550 nm and it provides monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in ADVA Optical
Networking’s devices with XFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with XFP types approved by
ADVA Optical Networking only.
XFP/11G/1310S/SM/LC/TIN
The XFP/11G/1310S/SM/LC/TIN is an MSA-compliant pluggable transceiver for 10
Gbit/s and 11 Gbit/s data rates and bidirectional communication over single-mode fiber. It
is operating at a wavelength of 1310 nm and it provides monitoring of operating
parameters such as optical input power, temperature or laser bias. Functionality and valid
certification of transponder modules can be guaranteed with XFP types approved by
ADVA Optical Networking only.
XFP/11G/1550L/SM/LC/TIN
The XFP/11G/1550L/SM/LC/TIN is an MSA-compliant pluggable transceiver for 10
Gbit/s data rates and bidirectional communication over single-mode fiber. It is operating
at a wavelength of 1550 nm and it provides monitoring of operating parameters such as
optical input power, temperature or laser bias. Functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
XFP/11G/1550V/SM/LC/TIN
The XFP/11G/1550V/SM/LC/TIN is an MSA-compliant pluggable transceiver for 10
Gbit/s data rates and bidirectional communication over single-mode fiber. It is operating
at a wavelength of 1550 nm and it provides monitoring of operating parameters such as
optical input power, temperature or laser bias. Functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
SFP+/10G/1310S/SM/LC
The SFP+/10G/1310S/SM/LC is an MSA-compliant pluggable transceiver supporting up
to 10 Gbit/s data rates and bidirectional communication over single-mode fiber. It is
operating at a wavelength of 1310 nm and it provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in ADVA
Optical Networking’s devices with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types approved by
ADVA Optical Networking only.
SFP+/10G/850I/MM/LC
The SFP+/10G/850I/MM/LC is an MSA-compliant pluggable transceiver supporting up to
10 Gbit/s data rates and bidirectional communication over multimode fiber. It is operating
at a wavelength of 850 nm and it provides monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in ADVA Optical
Networking’s devices with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types approved by
ADVA Optical Networking only.
1
HW Rev. 2.01 and newer only, which is supported as of Release 11.2.2.
SFP/4GU/1310S/SM/LC
The SFP/4GU/1310S/SM/LC is an MSA-compliant pluggable 1310 nm transceiver for
bidirectional communication over single-mode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. It is intended for use in
ADVA Optical Networking’s devices with SFP interface cages. Proper functionality and
valid certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
Receiver dynamic range -18 dBm ... -1 dBm (from 1.0625 Gbit/s upto
3.072 Gbit/s)
-15 dBm ... -1 dBm at 4.25 Gbit/s
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
The SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at DWDM
wavelengths according to ITU-T G.694.1. It provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in ADVA
Optical Networking’s devices with SFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
Dispersion load range with 1 dB -500 ps/nm ... +100 ps/nm and
OSNR penalty +800 ps/nm ... +1400 ps/nm
Dispersion load range with 2 dB -1100 ps/nm ... -500 ps/nm and
OSNR penalty +1400 ps/nm ... +2000 ps/nm
Dispersion load range with 3 dB -1500 ps/nm ... -1100 ps/nm and
OSNR penalty +2000 ps/nm ... +2400 ps/nm
Receiver wavelength range 1271 nm, 1291 nm, 1311 nm, 1331 nm,
1351 nm, 1371 nm, 1431 nm, 1451 nm
according to ITU-T G.694.2
Receiver wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
SFP/2G5U/1310L/SM/LC
The SFP/2G5U/1310L/SM/LC is an MSA-compliant pluggable 1310 nm transceiver for
bidirectional communication over single-mode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. It is intended for use in
ADVA Optical Networking’s devices with SFP interface cages. Proper functionality and
valid certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
SFP/HS/1310S/SM/LC
The SFP/HS/1310S/SM/LC is an MSA-compliant pluggable 1310 nm transceiver for
bidirectional communication over single-mode or multimode fiber. It provides monitoring
of operating parameters such as optical input power, temperature or laser bias.
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
SFP/2G1/850I/MM/LC
The SFP/2G1/850I/MM/LC is an MSA-compliant pluggable 850 nm transceiver for
bidirectional communication over multimode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias.
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
SFP/GBE/1310S/SM/LC/TIN
The SFP/GBE/1310S/SM/LC/TIN is an MSA-compliant pluggable 1310 nm transceiver
for bidirectional communication over single-mode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. This pluggable
transceiver supports an operating temperature within the industrial temperature range
(see Table 24).
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
1
125 Mbit/s not useable in FSP 3000R7.
SFP/GBE/1310L/SM/LC/TIN
The SFP/GBE/1310L/SM/LC/TIN is an MSA-compliant pluggable 1310 nm transceiver
for bidirectional communication over single-mode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. This pluggable
transceiver supports an operating temperature within the industrial temperature range
(see Table 25).
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
1
125 Mbit/s not useable in FSP 3000R7.
SFP/GBE/1550V/SM/LC/TIN
The SFP/GBE/1550V/SM/LC/TIN is an MSA-compliant pluggable 1550 nm transceiver
for bidirectional communication over single-mode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. This pluggable
transceiver supports an operating temperature within the industrial temperature range
(see Table 26).
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
1
125 Mbit/s not useable in FSP 3000R7.
SFP/GBE/850I/MM/LC/TIN
The SFP/GBE/850I/MM/LC/TIN is an MSA-compliant pluggable 850 nm transceiver for
bidirectional communication over multimode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. This pluggable
transceiver supports an operating temperature within the industrial temperature range
(see Table 27).
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
1
125 Mbit/s not useable in FSP 3000R7.
SFP/GBE/Electrical/RJ45
The SFP/GBE/Electrical/RJ45 is a pluggable transceiver that provides an electrical Gbit
Ethernet port. It is intended for use in FSP 3000R7 modules with SFP interface cages on
client ports. Proper functionality and valid certification of transponder modules can be
guaranteed with SFP types approved by ADVA Optical Networking only.
This pluggable transceiver does not support error propagation code (EPC) as error
forwarding mode on FSP 3000R7.
Protocols 10/100/1000BASE-T1
1
10/100BASE-T not useable in FSP 3000R7
SFP/SOAM/GBE/1310S/SM/LC/TIN
The SFP/SOAM/GBE/1310S/SM/LC/TIN is a state-of-the-art 1310 nm, 1000Base-LX,
Gigabit Ethernet small form factor pluggable (SFP) transceiver that enables testing and
troubleshooting processes by supporting port and VLAN loopbacks via proprietary in-
band control mechanism. This enables commissioning, verification and troubleshooting
tests such as RFC-2544 and Y.1564 to be executed on an access circuit without
deploying a stand-alone network interface demarcation device. The
SFP/SOAM/GBE/1310S/SM/LC/TIN module can be controlled from ADVA Optical
Networking equipment, or remote test set. Future software upgrades will allow the SFP to
source test traffic for RFC-2544 and Y.1564 tests, as well as to peer with Y.1731 OAM
infrastructures for in-service monitoring of key performance indicators like network delay,
jitter, and packet loss to guarantee service level agreements (SLAs) are met.
The SFP supports bidirectional communication over singlemode fibers, operating at a
wavelength of 1310 nm. It provides monitoring of operating parameters such as optical
input power, temperature and laser bias. This pluggable transceiver supports an operating
temperature within the industrial temperature range. Proper functionality and valid
certification of transceivers can be guaranteed with SFP types approved by ADVA
Optical Networking only.
SFP/FE/C1490U/SM/LC
The SFP/FE/C1490U/SM/LC is an MSA-compliant pluggable transceiver for bidirectional
communication over single-mode fiber. It is operating at 1490 nm. It provides monitoring
of operating parameters such as optical input power, temperature or laser bias. It is
intended for use in ADVA Optical Networking’s devices with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
Receiver dynamic range -42 dBm ... -9 dBm (BER < 10-7)
SFP/FE/C1510U/SM/LC
The SFP/FE/C1510U/SM/LC is an MSA-compliant pluggable transceiver for bidirectional
communication over single-mode fiber. It is operating at 1510 nm. It provides monitoring
of operating parameters such as optical input power, temperature or laser bias. It is
intended for use in ADVA Optical Networking’s devices with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
Receiver dynamic range -42 dBm ... -9 dBm (BER < 10-7)
SFP/FE/C1490V/SM/LC
The SFP/FE/C1490V/SM/LC is an MSA-compliant pluggable transceiver for bidirectional
communication over single-mode fiber. It is operating at 1490 nm. It provides monitoring
of operating parameters such as optical input power, temperature or laser bias. It is
intended for use in FSP 3000R7 modules with SFP interface cages. Proper functionality
and valid certification of transponder modules can be guaranteed with SFP types
approved by ADVA Optical Networking only.
Receiver dynamic range -30 dBm ... 0 dBm (BER < 10-7)
SFP/FE/C1510V/SM/LC
The SFP/FE/C1510V/SM/LC is an MSA-compliant pluggable transceiver for bidirectional
communication over single-mode fiber. It is operating at 1510 nm. It provides monitoring
of operating parameters such as optical input power, temperature or laser bias. It is
intended for use in FSP 3000R7 modules with SFP interface cages. Proper functionality
and valid certification of transponder modules can be guaranteed with SFP types
approved by ADVA Optical Networking only.
Receiver dynamic range -30 dBm ... 0 dBm (BER < 10-7)
1061700618-01 CFP/112G/#DCTCF/SM/LC
1061700619-01 CFP/112G/#DCTC/SM/LC
1061700620-01 CFP/4x28G/#DCTL/SM/LC
1061700654-01 CFP/112G/ER4/SM/LC
1061700655-01 CFP/112G/LR4/SM/LC
1061700656-01 CFP/112G/SR10/MM/MPO
1061700657-01 CFP/103G/SR10/MM/MPO
1061701121-01 SFP+CDR/16FC/1310S/SM/LC
1061701125-01 SFP+CDR/16FC/850I/MM/LC
1061701131-01 SFP+/16GFC/1310S/SM/LC
1061701135-01 SFP+/16GFC/850I/MM/LC
1061701200-01 XFP/11G/DCTLN/SM/LC
1061701400-01 XFP/11G/DCTV/SM/LC
1061001893-01 XFP/11G/B1270L/SM/LC/TIN
1061001894-01 XFP/11G/B1330L/SM/LC/TIN
1061001895-01 XFP/11G/B1270S/SM/LC/TIN
1061001896-01 XFP/11G/B1330S/SM/LC/TIN
1061701499-01 XFP/11G/DCTVX/SM/LC
0061701811-03 XFP/11G/1310S/SM/LC
0061701812 XFP/11G/1550L/SM/LC
1061701861-01 SFP+CDR/10GU/1550L/SM/LC
1061701863-01 SFP+CDR/11GU/1310S/SM/LC
1061701871-01 SFP+CDR/11GU/B1270S/SM/LC
1061701872-01 SFP+CDR/11GU/B1330S/SM/LC
1061701873-01 SFP+CDR/11GU/B1270L/SM/LC
1061701874-01 SFP+CDR/11GU/B1330L/SM/LC
1061702000-01 SFP+/11GU/DCTV/SM/LC
1061702100-01 SFP+/11GU/DCTLN/SM/LC
1061701851-01 SFP+/10G/1310S/SM/LC
1061701854-01 SFP+/11GU/850I/MM/LC
1061701855-01 SFP+/10G/850I/MM/LC
1061701833-02 XFP/8G/1310S/SM/LC
1061701837-02 XFP/8G/850I/MM/LC
1061701853-01 SFP+/8GU/1310S/SM/LC
1061701857-01 SFP+/8GU/850I/MM/LC
0061703805 SFP/4GU/1310S/SM/LC
0061703825 SFP/4GU/850I/MM/LC
0061705807 SFP/2G5U/1310L/SM/LC
0061705824 SFP/HS/1310S/SM/LC
0061705844-03 SFP/2G1/850I/MM/LC
1061705828-01 SFP-RXTX/MADI/1310I/MM/LC
1061705850-02 SFP/GBE/1310S/SM/LC/TIN
1061705851-02 SFP/GBE/1310L/SM/LC/TIN
1061705852-02 SFP/GBE/1550V/SM/LC/TIN
1061705854-02 SFP/GBE/850I/MM/LC/TIN
0061705890 SFP/GBE/Electrical/RJ45
1061705876-01 SFP/GBE/B1310S/SM/LC
1061705877-01 SFP/GBE/B1490S/SM/LC
0061705992 SFP/FE/C1490U/SM/LC
0061705993 SFP/FE/C1510U/SM/LC
1061706083 SFP/FE/D1528.77E/SM/LC
1061706192 SFP/FE/C1490V/SM/LC
1061706193 SFP/FE/C1510V/SM/LC
1061707856-01 SFP-2TX/3GSDI/1310S/SM/LC
1061707857-01 SFP-2RX/3GSDI/1310S/SM/LC
1061707866-01 SFP-2TX/3GSDI/ELECTRICAL/HBNC
1061707867-01 SFP-2RX/3GSDI/ELECTRICAL/HBNC
1061707881-01 SFP/3GSDI/ELECTRICAL/DIN
1061707880-01 SFP/3GSDI/ELECTRICAL/HBNC
CFP/112G/#DCTCF/SM/LC
The CFP/112G/#DCTCF/SM/LC is a coherent 112G CFP MSA-compliant transceiver
used to transmit OTU4V with a data rate of 120.58 Gbit/s for bidirectional communication
over single-mode fiber in metro and metro regional networks. This CFP transceiver
module has a dual polarization quadrature phase shift keying (DP-QPSK) transmitter and
features an integrated soft decision FEC. It supports both 50 GHz and 37.5GHz channel
grid.
The transceiver provides monitoring of operating parameters such as optical input/output
power, module temperature, laser bias and other relevant values.
It is intended for use in FSP 3000R7 modules with CFP interface cages on network ports.
Proper functionality and valid certification of transponder modules can be guaranteed with
CFP types approved by ADVA Optical Networking only.
Dispersion load range with 0.3 dB OSNR -6,000 ps/nm ... -2,500 ps/nm and
penalty +2,500 ps/nm ... +22,000 ps/nm
Dispersion load range with 1 dB OSNR +22,000 ps/nm ... +40,000 ps/nm
penalty
OSNR penalty for 37.5 GHz channel 2 dB for a maximum channel power
spacing difference of 6 dB
0.5 dB for a channel power difference of 0
dB
OPT accuracy 1 dB
OPR accuracy 2 dB
1
Output power is settable in steps of 0.1 dB at any power level within the specified
frequency range.
2
Frequency intended to be received must be the same as frequency that is
transmitted.
3
Even without dispersion load and high OSNR values a certain Pre-FEC BER will
appear. This is due to the fact that this CFP is optimized for covering a huge
dispersion load range.
CFP/112G/#DCTC/SM/LC
The CFP/112G/#DCTC/SM/LC is a coherent 100G CFP MSA-compliant transceiver
used to transmit OTU4V with a data rate of 120.58 Gbit/s over single-mode fiber in metro
and metro regional networks. This CFP transceiver module has a dual polarization
quadrature phase shift keying (DP-QPSK) transmitter and features an integrated soft
decision FEC.
The transceiver provides monitoring of operating parameters such as optical input/output
power, module temperature, laser bias and other relevant values.
It is intended for use in FSP 3000R7 modules with CFP interface cages on network ports.
Proper functionality and valid certification of transponder modules can be guaranteed with
CFP types approved by ADVA Optical Networking only.
Dispersion load range with 0.3dB OSNR -6,000 ps/nm ... -2,500 ps/nm and
penalty +2,500 ps/nm ... +22,000 ps/nm
Dispersion load range with 1 dB OSNR +22,000 ps/nm ... +40,000 ps/nm
penalty
OPT accuracy 1 dB
OPR accuracy 2 dB
1
Output power is settable in steps of 0.1 dB at any power level within the specified
frequency range.
2
Frequency intended to be received must be the same as frequency that is
transmitted.
3
Even without dispersion load and high OSNR values a certain Pre-FEC BER will
appear. This is due to the fact that this CFP is optimized for covering a huge
dispersion load range.
CFP/4x28G/#DCTL/SM/LC
The CFP/4x28G/#DCTL/SM/LC is an MSA-compliant CFP transceiver used to transmit
high speed data rates for bidirectional communication over single-mode fiber. For data
transmission the signal is divided into four optical WDM lanes supporting DWDM C-band
channels according to ITU-T G.694.1.
This transceiver supports fixed channel spacing at 100 GHz between four optical lanes.
The entire four lanes can be tuned as a block on a 50 GHz grid across 96 channels in the
C band. This supports up to 24 OTU4 services.
The CFP/4x28G/#DCTL/SM/LC provides monitoring of operating parameters such as
optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with CFP
types approved by ADVA Optical Networking only.
The optical performance values listed below are specified for a 50 GHz grid filter system.
The CFP/4x28G/#DCTL/SM/LC can be used in a 100 GHz grid filter system as well. In
this case penalties have to be taken into account. Contact ADVA Optical Networking’s
Network Consulting for details, please.
Protocols OTU4
Dispersion load range with 1 dB OSNR -400 ps/nm to -250 ps/nm and +250
penalty ps/nm to +400 ps/nm
CFP/4x28G/#19xxx-#19xxxL/SM/LC
The CFP/4x28G/#19xxx-#19xxxL/SM/LC is an MSA-compliant CFP transceiver used to
transmit high speed data rates for bidirectional communication over single-mode fiber. For
data transmission the signal is divided into four optical WDM lanes supporting DWDM C-
band channels according to ITU-T G.694.1.
This type of CFP is available in five variants:
• CFP/4x28G/#19595-#19520L/SM/LC
• CFP/4x28G/#19515-#19440L/SM/LC
• CFP/4x28G/#19435-#19360L/SM/LC
• CFP/4x28G/#19355-#19280L/SM/LC
• CFP/4x28G/#19275-#19200L/SM/LC
Each variant supports fixed channel spacing at 100 GHz between the optical lanes. The
entire 4 lanes can be tuned as a block up to 400 GHz on a 50 GHz grid. With the 5
different variants up to 20 OTU4 services are supported within 80 channels in the C band.
The CFP/4x28G/#19xxx-#19xxxL/SM/LC provides monitoring of operating parameters
such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with CFP
types approved by ADVA Optical Networking only.
The optical performance values listed below are specified for a 50 GHz grid filter system.
CFP/4x28G/#19xxx-#19xxxL/SM/LC can be used in a 100 GHz grid filter system as well.
In this case penalties have to be taken into account. Contact ADVA Optical Networking’s
Network Consulting for details, please.
Degree of protection according to IEC 60529 IP20. Use in a pollution degree 2 environment and
indoor controlled office environments only.
Protocols OTU4
Dispersion load range with 1 dB OSNR penalty -400 ps/nm to -250 ps/nm and
+250 ps/nm to +400 ps/nm
OSNR penalty
• at 2.3 ps PMD for BER < 10-3 • 1 dB (outage probability 4x10-5)
• at 3.3 ps PMD for BER < 10-3 • 2 dB (outage probability 4x10-5)
• at 4.6 ps PMD for BER < 10-3 • 4 dB (outage probability 4x10-5)
• at 2.3 ps PMD for BER < 5 x 10-5 • 1.5 dB (outage probability 4x10-5)
• at 3.3 ps PMD for BER < 5 x 10-5 • 2.5 dB (outage probability 4x10-5)
• at 4.6 ps PMD for BER < 5 x 10-5 • 4.5 dB (outage probability 4x10-5)
CFP/4x28G/#19xxx-#19xxxLR/SM/LC
The CFP/4x28G/#19xxx-#19xxxLR/SM/LC is an MSA-compliant CFP transceiver used
to transmit high speed data rates for bidirectional communication over single-mode fiber.
For data transmission the signal is divided into four optical WDM lanes supporting
DWDM C-band channels according to ITU-T G.694.1.
This type of CFP is available in 24 variants for covering all 96 frequencies of the 50 GHz
channel grid. Each variant supports four optical lanes with fixed
100 GHz spaced frequencies.
The CFP/4x28G/#19xxx-#19xxxLR/SM/LC provides monitoring of operating parameters
such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with CFP
types approved by ADVA Optical Networking only.
Protocols OTU4
OSNR penalty
• at 7 ps PMD for BER < 10-3 • 1 dB (outage probability 4x10-5)
• at 10 ps PMD for BER < 10-3 • 2 dB (outage probability 4x10-5)
• at 14 ps PMD for BER < 10-3 • 4 dB (outage probability 4x10-5)
• at 7 ps PMD for BER < 5 x 10-5 • 1.5 dB (outage probability 4x10-5)
• at 10 ps PMD for BER < 5 x 10-5 • 2.5 dB (outage probability 4x10-5)
• at 14 ps PMD for BER < 5 x 10-5 • 4.5 dB (outage probability 4x10-5)
CFP/112G/ER4/SM/LC
The CFP/112G/ER4/SM/LC is a CFP MSA-compliant transceiver used to transmit high
speed data rates of 103.125 Gbit/s and 111.81 Gbit/s for bidirectional communication
over single-mode fiber. This CFP has an integrated MUX and DEMUX filter for
transmitting data signal divided into ten optical WDM lanes supporting wavelengths. This
transceiver provides monitoring of operating parameters such as optical input power,
temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages on client ports
and network ports. Proper functionality and valid certification of transponder modules can
be guaranteed with CFP types approved by ADVA Optical Networking only.
Transmitter output power range, each lane1 -2.7 dBm ... +2.9 dBm
Optical modulation amplitude, each lane -0.1 dBm ... +4.5 dBm
(OMA2)
Receiver dynamic range, each lane3 -20.9 dBm ... +4.5 dBm
Receiver dynamic range, each lane (OMA2) -21.4 dBm ... +4.5 dBm
1
Transmitter output power range, each lane (min) is informative and not the principal
indicator of signal strength. A transmitter with output power below this value cannot
be compliant; however, a value above this does not ensure compliance.
2
3
Receiver dynamic range, each lane (min) is informative and not the principal
indicator of signal strength. A received power below this value cannot be compliant;
however, a value above this does not ensure compliance.
CFP/112G/LR4/SM/LC
The CFP/112G/LR4/SM/LC is an MSA-compliant CFP transceiver used to transmit high
speed data rates of 103.125 Gbit/s and 111.81 Gbit/s for bidirectional communication
over single-mode fiber. This CFP has an integrated MUX and DEMUX filter for
transmitting data signal divided into four different optical WDM lanes supporting
wavelengths. It provides monitoring of operating parameters such as optical input power,
optical output power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with CFP interface cages on client ports.
Proper functionality and valid certification of transponder modules can be guaranteed with
CFP types approved by ADVA Optical Networking only.
1
Transmitter output power range, each lane (min) is informative and not the principal
indicator of signal strength. A transmitter with output power below this value cannot
be compliant; however, a value above this does not ensure compliance.
2
3
Receiver dynamic range, each lane (min) is informative and not the principal
indicator of signal strength. A received power below this value cannot be compliant;
however, a value above this does not ensure compliance.
CFP/112G/SR10/MM/MPO
The CFP/112G/SR10/MM/MPO is an MSA-compliant CFP transceiver, SR10 type, used
to transmit high speed data rates for bidirectional communication.
This CFP transceiver module offers ten optical transmit and receive channels.
The CFP/112G/SR10/MM/MPO is intended for use in FSP 3000R7 modules with CFP
interface cages on client ports and network ports. Proper functionality and valid
certification of transponder modules can be guaranteed with CFP types approved by
ADVA Optical Networking only.
Transmitter output power range, each lane1 -7.6 dBm ... +2.4 dBm
Receiver dynamic range, each lane3 -9.5 dBm ... +2.4 dBm
Receiver dynamic range, each lane (OMA2) -7.5 dBm ... +3 dBm
The front cover of the SH9HU shelf can be used only in combination with
the Cover Extension.
Note
1
Transmitter output power range, each lane (min) is informative and not the principal
indicator of signal strength. A transmitter with output power below this value cannot
be compliant; however, a value above this does not ensure compliance.
2
3
Receiver dynamic range, each lane (min) is informative and not the principal
indicator of signal strength. A received power below this value cannot be compliant;
however, a value above this does not ensure compliance.
CFP/103G/SR10/MM/MPO
The CFP/103G/SR10/MM/MPO is an MSA-compliant CFP transceiver, SR10 type, used
to transmit high speed data rate of 103.125 Gbit/s for bidirectional communication over
multimode fiber.
This CFP transceiver module offers ten independent transmit and receive channels, each
capable of 10.3 Gbit/s operation per lane. It provides separate fibre connection per optical
lane through a single MPO24 port which connects to an industry standard 2x12 parallel
multimode fiber cable (4 optical lanes are not used).
The CFP/103G/SR10/MM/MPO is intended for use in FSP 3000R7 modules with CFP
interface cages on client ports. Proper functionality and valid certification of transponder
modules can be guaranteed with CFP types approved by ADVA Optical Networking only.
Transmitter output power range, each lane1 -7.6 dBm ... +2.4 dBm
Receiver dynamic range, each lane3 -9.5 dBm ... +2.4 dBm
Receiver dynamic range, each lane (OMA2) -7.5 dBm ... +3 dBm
The front cover of the SH9HU shelf can be used only in combination with
the Cover Extension.
Note
1
Transmitter output power range, each lane (min) is informative and not the principal
indicator of signal strength. A transmitter with output power below this value cannot
be compliant; however, a value above this does not ensure compliance.
2
3
Receiver dynamic range, each lane (min) is informative and not the principal
indicator of signal strength. A received power below this value cannot be compliant;
however, a value above this does not ensure compliance.
SFP+/16GFC/#19xxxL50/SM/LC
The SFP+/16GFC/#19xxxL50/SM/LC is an MSA-compliant pluggable transceiver
supporting up to 14.025 Gbit/s data rates and bidirectional communication over single-
mode fiber.
This transceiver is operating at DWDM wavelengths according to ITU-T G.694.1 and
provides monitoring of operating parameters such as optical input power, temperature or
laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP+
types approved by ADVA Optical Networking only.
Protocols • 4G FC
• 5G IB
• 8G FC
• STM-64/OC-192
• 10 GbE WAN PHY
• 10G IB
• 10 GbE LAN PHY
• 10G FC
• OTU2
• OTU2V
• OTU1e
• OTU2e
• OTU2f
• 16G FC
Dispersion load range with 2 dB -400 ps/nm ... -200 ps/nm and
OSNR penalty +400 ps/nm ... +800 ps/nm
mm, ttttttt tt
SFP+CDR/16FC/1310S/SM/LC
The SFP+CDR/16FC/1310S/SM/LC is an MSA-compliant pluggable transceiver for data
rates of up to 14.025 Gbit/s and bidirectional communication over single-mode fiber. This
transceiver supports clock and data recovery.
The SFP+CDR/16FC/1310S/SM/LC operates at a wavelength of 1310 nm and provides
monitoring of operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP+
types approved by ADVA Optical Networking only.
SFP+CDR/16FC/850I/MM/LC
The SFP+CDR/16FC/850I/MM/LC is an MSA-compliant pluggable transceiver for data
rates of up to 14.025 Gbit/s and bidirectional communication over multimode fiber. This
transceiver supports clock and data recovery.
The SFP+CDR/16FC/850I/MM/LC operates at a wavelength of 850 nm and provides
monitoring of operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP+
types approved by ADVA Optical Networking only.
SFP+/16GFC/1310S/SM/LC
The SFP+/16GFC/1310S/SM/LC is an MSA-compliant pluggable transceiver for data
rates up to 14.025 Gbit/s and bidirectional communication over single-mode fiber. It is
operating at a wavelength of 1310 nm and it provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
SFP+/16GFC/850I/MM/LC
The SFP+/16GFC/850I/MM/LC is an MSA-compliant pluggable transceiver for data rates
up to 14.025 Gbit/s data rates and bidirectional communication over multimode fiber. It is
operating at a wavelength of 850 nm and it provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
XFP/11G/DCTLN/SM/LC
The XFP/11G/DCTLN/SM/LC is an Multi-Protocol Optical XFP that provides a high
speed serial link for up to 11 Gbit/s data rates. It is used for bidirectional communication
over single-mode fiber. This tunable DWDM XFP transceiver is an MSA-compliant
pluggable transceiver, which complies with the ITU-T G.698.1 SD100S1-2D for the C
band in a wavelength grid of 50 GHz.
The transmitter is fully tunable to any of the C-band channels. Each channel can be tuned
in the system management by using the NE management tools.
The XFP/11G/DCTLN/SM/LC offers a high extinction ratio and thus it is suitable for links
with a high amount of amplifiers and low OSNR.
This transceiver is intended for use in FSP 3000R7 modules with tunable XFP interface
cages. Proper functionality and valid certification of transponder modules can be
guaranteed with XFP types approved by ADVA Optical Networking only.
Protocols • STM-64/OC-192
• 10 GbE LAN PHY
• 10 GbE WAN PHY
• 10 G FC
• OTU2
• OTU1e
• OTU2e
Dispersion load range with 1 dB OSNR -500 ps/nm ... -300 ps/nm and
penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB OSNR -700 ps/nm ... -500 ps/nm and
penalty +500 ps/nm ... +700 ps/nm
1The performance at low OSNR values and bit error ratios above 10-4 can be
achieved with enabled FEC and adaptive threshold control (ATC) of the respective
channel module only. For adjusting the threshold the ATC may need up to 10
minutes.
XFP/11G/DCTV/SM/LC
The XFP/11G/DCTV/SM/LC is a Multi-Protocol Optical XFP that provides a high speed
serial link at data rates from 9.95 Gbit/s to 11.35 Gbit/s. It is used for bidirectional
communication over single-mode fiber.
The transmitter is fully tunable to any of the C-band channels. Each channel can be tuned
in the system management by using the NE management tools.
It is intended for use in ADVA Optical Networking’s devices with XFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
XFP types approved by ADVA Optical Networking only.
Receiver dynamic range for OSNR > -22 dBm ... -7 dBm
30 dB (0.1 nm)
Receiver dynamic range for OSNR < -20 dBm ... -7 dBm
30 dB (0.1 nm)
Dispersion load range with 1 dB -100 ps/nm ... +300 ps/nm and +1000 ps/nm ...
OSNR penalty +1300 ps/nm
Dispersion load range with 2 dB -400 ps/nm ... -100 ps/nm and
OSNR penalty +1300 ps/nm ... +1500 ps/nm
Dispersion load range with 1 dB -200 ps/nm ... +100 ps/nm and
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2 dB -500 ps/nm ... -200 ps/nm and
OSNR penalty +1100 ps/nm ... +1400 ps/nm
XFP/11G/#19xxxL50/SM/LC
The XFP/11G/#19xxxL50/SM/LC is an MSA-compliant pluggable transceiver for up to 11
Gbit/s data rates and bidirectional communication over single-mode fiber. It is operating
at DWDM wavelengths according to ITU-T G.694.1 and it provides monitoring of
operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with XFP
types approved by ADVA Optical Networking only.
Protocols • STM-64/OC-192
• 10 GbE LAN PHY
• 10 GbE WAN PHY
• 10 G FC
• OTU2
• OTU1e
• OTU2e
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and
OSNR penalty +300 ps/nm ...+500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and
OSNR penalty +500 ps/nm ... +700 ps/nm
XFP/11G/CxxxxV/SM/LC
The XFP/11G/CxxxxV/SM/LC is an MSA-compliant pluggable transceiver for 11 Gbit/s
data rates and bidirectional communication over single-mode fiber. It is operating at
CWDM wavelengths according to ITU-T G.694 and it provides monitoring of operating
parameters such as optical input power, temperature or laser bias.
It is intended for use in ADVA Optical Networking’s devices with XFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
XFP types approved by ADVA Optical Networking only.
XFP/11G/B1270L/SM/LC/TIN
The XFP/11G/B1270L/SM/LC/TIN is an MSA-compliant pluggable long-reach transceiver
for data rates of up to 11.3176 Gbit/s and bidirectional communication over a single strand
of optical fiber. It transmits signals with a wavelength of 1270 nm and receives signals
with a wavelength of 1330 nm. Therefore, the device can only be used in pairs with a
complementary bidirectional (BiDi) XFP transceiver. The XFP/11G/B1270L/SM/LC/TIN
must be matched with XFP/11G/B1330L/SM/LC/TIN transceiver for correct operation
over a single optical fiber.
This pluggable transceiver supports an operating temperature within the industrial
temperature range.
The XFP/11G/B1270L/SM/LC/TIN provides monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with XFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
XFP/11G/B1330L/SM/LC/TIN
The XFP/11G/B1330L/SM/LC/TIN is an MSA-compliant pluggable long-reach transceiver
for data rates of up to 11.3176 Gbit/s and bidirectional communication over a single strand
of optical fiber. It transmits signals with a wavelength of 1330 nm and receives signals
with a wavelength of 1270 nm. Therefore, the device can only be used in pairs with a
complementary bidirectional (BiDi) XFP transceiver. The XFP/11G/B1330L/SM/LC/TIN
must be matched with XFP/11G/B1270L/SM/LC/TIN transceiver for correct operation
over a single optical fiber.
This pluggable transceiver supports an operating temperature within the industrial
temperature range.
The XFP/11G/B1330L/SM/LC/TIN provides monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with XFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
XFP/11G/B1270S/SM/LC/TIN
The XFP/11G/B1270S/SM/LC/TIN is an MSA-compliant pluggable short-reach
transceiver for data rates of up to 11.3176 Gbit/s and bidirectional communication over a
single strand of optical fiber. It transmits signals with a wavelength of 1270 nm and
receives signals with a wavelength of 1330 nm. Therefore, the device can only be used in
pairs with a complementary bidirectional (BiDi) XFP transceiver. The
XFP/11G/B1270S/SM/LC/TIN must be matched with XFP/11G/B1330S/SM/LC/TIN
transceiver for correct operation over a single optical fiber.
This pluggable transceiver supports an operating temperature within the industrial
temperature range.
The XFP/11G/B1270S/SM/LC/TIN provides monitoring of operating parameters such as
optical input power, temperature or optical output power. It is intended for use in FSP
3000R7 modules with XFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
XFP/11G/B1330S/SM/LC/TIN
The XFP/11G/B1330S/SM/LC/TIN is an MSA-compliant pluggable short-reach
transceiver for data rates of up to 11.3176 Gbit/s and bidirectional communication over a
single strand of optical fiber. It transmits signals with a wavelength of 1330 nm and
receives signals with a wavelength of 1270 nm. Therefore, the device can only be used in
pairs with a complementary bidirectional (BiDi) XFP transceiver. The
XFP/11G/B1330S/SM/LC/TIN must be matched with XFP/11G/B1270S/SM/LC/TIN
transceiver for correct operation over a single optical fiber.
This pluggable transceiver supports an operating temperature within the industrial
temperature range.
The XFP/11G/B1330S/SM/LC/TIN provides monitoring of operating parameters such as
optical input power, temperature or optical output power. It is intended for use in FSP
3000R7 modules with XFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
XFP/11G/DCTVX/SM/LC
The XFP/11G/DCTVX/SM/LC is a Multi-Protocol Optical XFP that provides a high speed
serial link at data rates from 9.95 Gbit/s to 11.35 Gbit/s. It is used for bidirectional
communication over single-mode fiber.
The transmitter is fully tunable to any of the C-band channels. Each channel can be tuned
in the system management by using the NE management tools.
It is intended for use in ADVA Optical Networking’s devices with XFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
XFP types approved by ADVA Optical Networking only.
Dispersion load range with 1 dB -100 ps/nm ... +300 ps/nm and +1000 ps/nm ...
OSNR penalty +1300 ps/nm
Dispersion load range with 2 dB -400 ps/nm ... -100 ps/nm and
OSNR penalty +1300 ps/nm ... +1500 ps/nm
XFP/11G/CxxxxL/SM/LC
The XFP/11G/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for 11 Gbit/s
data rates and bidirectional communication over single-mode fiber. It is operating at
CWDM wavelengths according to ITU-T G.694.2 and it provides monitoring of operating
parameters such as optical input power, temperature or laser bias.
It is intended for use in ADVA Optical Networking’s devices with XFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
XFP types approved by ADVA Optical Networking only.
XFP/11G/1310S/SM/LC
The XFP/11G/1310S/SM/LC is an MSA-compliant pluggable transceiver for 10 Gbit/s
and 11 Gbit/s data rates and bidirectional communication over single-mode fiber. It is
operating at a wavelength of 1310 nm and it provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in ADVA
Optical Networking’s devices with XFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with XFP types approved by
ADVA Optical Networking only.
XFP/11G/1550L/SM/LC
The XFP/11G/1550L/SM/LC is an MSA-compliant pluggable transceiver for 10 Gbit/s
data rates and bidirectional communication over single-mode fiber. It is operating at a
wavelength of 1550 nm and it provides monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in ADVA Optical
Networking’s devices with XFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with XFP types approved by
ADVA Optical Networking only.
SFP+CDR/11GU/#19xxxV/SM/LC
The SFP+CDR/11GU/#19xxxV/SM/LC is an MSA-compliant pluggable transceiver for
data rates up to 11.3176 Gbit/s and bidirectional communication over single-mode fiber. It
supports clock and data recovery.
This transceiver is operating at 100GHz DWDM wavelengths according to ITU-T G.694.1
and it provides monitoring of operating parameters such as optical input and output power
or temperature.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
Protocols • 8G FC
• STM-64/OC-192
• 10 GbE WAN PHY
• 10G IB
• 10 GbE LAN PHY
• 10G FC
• OTU2
• OTU2V
• OTU1e
• OTU2e
• OTU2f
Dispersion load range with 1 dB -200 ps/nm ... +100 ps/nm and
OSNR penalty +800 ps/nm ... +1100 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -200 ps/nm and
OSNR penalty +1100 ps/nm ... +1400 ps/nm
Maximum DGD 30 ps
SFP+CDR/11GU/CxxxxS/SM/LC
The SFP+CDR/11GU/CxxxxS/SM/LC is an MSA-compliant pluggable transceiver for up
to 11 Gbit/s data rates and bidirectional communication over single-mode fiber. This
transceiver supports clock and data recovery.
The SFP+CDR/11GU/CxxxxS/SM/LC operates at four CWDM wavelengths with
standard reach according to ITU-T G.694.2. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. This SFP+ transceiver
is intended to be used to connect to 40GBASE-LR4 using J/SM/4CS-#C1270-
#C1330/LC breakout cable.
The SFP+CDR/11GU/CxxxxS/SM/LC is intended for use in FSP 3000R7 modules with
SFP+ interface cages. Proper functionality and valid certification of transponder modules
can be guaranteed with SFP+ types approved by ADVA Optical Networking only.
Protocols • STM-64/OC-192
• 10 GbE WAN PHY
• 10G IB
• 10 GbE LAN PHY
• 10G FC
• OTU2
• OTU2V
• OTU1e
• OTU2e
• OTU2f
SFP+CDR/11GU/CxxxxL/SM/LC
The SFP+CDR/11GU/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for up
tp 11 Gbit/s data rates and bidirectional communication over single-mode fiber. This
transceiver supports clock and data recovery.
The SFP+CDR/11GU/CxxxxL/SM/LC is operating at eight CWDM wavelengths with
long reach according to ITU-T G.694.2. It provides monitoring of operating parameters
such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP+
types approved by ADVA Optical Networking only.
Protocols • 8G FC
• STM-64/OC-192
• 10 GbE WAN PHY
• 10G IB
• 10G FC
• OTU2
• OTU1e
• OTU2e
• OTU2f
SFP+CDR/10GU/1550L/SM/LC
The SFP+CDR/10GU/1550L/SM/LC is an MSA-compliant pluggable transceiver for up to
10 Gbit/s data rates. It is used for bidirectional communication over single-mode fiber.
This transceiver supports clock and data recovery.
The SFP+CDR/10GU/1550L/SM/LC is operating at a wavelength of 1550 nm and
provides monitoring of operating parameters such as optical input power, temperature or
laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP+
types approved by ADVA Optical Networking only.
SFP+CDR/11GU/1310S/SM/LC
The SFP+CDR/11GU/1310S/SM/LC is an MSA-compliant pluggable transceiver for up
to 11 Gbit/s data rates. It is used for bidirectional communication over single-mode fiber.
This transceiver supports clock and data recovery.
The SFP+CDR/11GU/1310S/SM/LC is operating at a wavelength of 1310 nm and
provides monitoring of operating parameters such as optical input power, temperature or
laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP+
types approved by ADVA Optical Networking only.
SFP+CDR/11GU/B1270S/SM/LC
The SFP+CDR/11GU/B1270S/SM/LC is an MSA-compliant pluggable short-reach
transceiver for data rates of up to 11.3176 Gbit/s and bidirectional communication over a
single strand of optical fiber. It integrates CDR functionality within TX and RX path. This
transceiver transmits signals with a wavelength of 1270 nm and receives signals with a
wavelength of 1330 nm. Therefore, the device can only be used in pairs with a
complementary bidirectional (BiDi) SFP transceiver.
The SFP+CDR/11GU/B1270S/SM/LC must be matched with
SFP+CDR/11GU/B1330S/SM/LC transceiver for correct operation over a single optical
fiber.
The SFP+CDR/11GU/B1270S/SM/LC provides monitoring of operating parameters such
as optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
SFP+CDR/11GU/B1330S/SM/LC
The SFP+CDR/11GU/B1330S/SM/LC is an MSA-compliant pluggable short-reach
transceiver for data rates of up to 11.3176 Gbit/s and bidirectional communication over a
single strand of optical fiber. It integrates CDR functionality within TX and RX path. This
transceiver transmits signals with a wavelength of 1330 nm and receives signals with a
wavelength of 1270 nm. Therefore, the device can only be used in pairs with a
complementary bidirectional (BiDi) SFP transceiver.
The SFP+CDR/11GU/B1330S/SM/LC must be matched with
SFP+CDR/11GU/B1270S/SM/LC transceiver for correct operation over a single optical
fiber.
The SFP+CDR/11GU/B1330S/SM/LC provides monitoring of operating parameters such
as optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
SFP+CDR/11GU/B1270L/SM/LC
The SFP+CDR/11GU/B1270L/SM/LC is an MSA-compliant pluggable long-reach
transceiver for data rates of up to 11.3176 Gbit/s and bidirectional communication over a
single strand of optical fiber. It integrates CDR functionality within TX and RX path. This
transceiver transmits signals with a wavelength of 1270 nm and receives signals with a
wavelength of 1330 nm. Therefore, the device can only be used in pairs with a
complementary bidirectional (BiDi) SFP transceiver.
The SFP+CDR/11GU/B1270L/SM/LC must be matched with
SFP+CDR/11GU/B1330L/SM/LC transceiver for correct operation over a single optical
fiber.
The SFP+CDR/11GU/B1270L/SM/LC provides monitoring of operating parameters such
as optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
SFP+CDR/11GU/B1330L/SM/LC
The SFP+CDR/11GU/B1330L/SM/LC is an MSA-compliant pluggable long-reach
transceiver for data rates of up to 11.3176 Gbit/s and bidirectional communication over a
single strand of optical fiber. It integrates CDR functionality within TX and RX path. This
transceiver transmits signals with a wavelength of 1330 nm and receives signals with a
wavelength of 1270 nm. Therefore, the device can only be used in pairs with a
complementary bidirectional (BiDi) SFP transceiver.
The SFP+CDR/11GU/B1330L/SM/LC must be matched with
SFP+CDR/11GU/B1270L/SM/LC transceiver for correct operation over a single optical
fiber.
The SFP+CDR/11GU/B1330L/SM/LC provides monitoring of operating parameters such
as optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
SFP+/11GU/DCTV/SM/LC
The SFP+/11GU/DCTV/SM/LC is an MSA-compliant Multi-Protocol Optical SFP+
transceiver that provides a high speed serial link at data rates from 5 Gbit/s to 11.31
Gbit/s. It is used for bidirectional communication over single-mode fiber. The transmitter
is fully tunable to any of the C-band channels. Each channel can be tuned in the system
management by using the NE management tools.
It is intended for use in ADVA Optical Networking’s devices with SFP+ interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP+ types approved by ADVA Optical Networking only.
Receiver dynamic range for OSNR > 30 dB -22 dBm ... -7 dBm
(0.1 nm)
Receiver dynamic range for OSNR < 30 dB -20 dBm ... -8 dBm
(0.1 nm)
Dispersion load range with 1 dB OSNR -400 ps/nm ... -200 ps/nm and
penalty +300 ps/nm ... +800 ps/nm
Dispersion load range with 2 dB OSNR -500 ps/nm ... -400 ps/nm and
penalty +800 ps/nm ... +1400 ps/nm
OSNR penalty at 10 ps PMD for BER > 10-5 1 dB (outage probability 4x10-5)
SFP+/11GU/DCTLN/SM/LC
The SFP+/11GU/DCTLN/SM/LC is an MSA-compliant, Multi-Protocol Optical SFP+
transceiver for up to 11 Gbit/s data rates and bidirectional communication over single-
mode fiber.
This transceiver supports DWDM wavelengths with long reach in the C-band both at 50
GHz and 100 GHz spacing according to ITU-T G.694.1. The transmitter is fully tunable to
any of the C-band channels. Each channel can be tuned in the system management by
using the NE management tools.
The SFP+/11GU/DCTLN/SM/LC offers a high extinction ratio and thus it is suitable for
links with a high amount of amplifiers and low OSNR. It provides monitoring of operating
parameters such as optical input and output power or temperature.
The transceiver is intended for use in ADVA Optical Networking’s devices with SFP+
interface cages.Proper functionality and valid certification of transponder modules can be
guaranteed with SFP+ types approved by ADVA Optical Networking only.
Dispersion load range with 1 dB OSNR -500 ps/nm ... -300 ps/nm and
penalty +300 ps/nm ... +500 ps/nm
Dispersion load range with 2 dB OSNR -700 ps/nm ... -500 ps/nm and
penalty +500 ps/nm ... +700 ps/nm
OSNR penalty at 10 ps PMD for BER > 10-5 1 dB (outage probability 4x10-5)
OSNR penalty at 7 ps PMD for BER > 10-12 1 dB (outage probability 4x10-5)
SFP+/11GU/#19xxxL50/SM/LC
The SFP+/11GU/#19xxxL50/SM/LC is an MSA-compliant pluggable transceiver for up to
11 Gbit/s data rates and bidirectional communication over single-mode fiber. It operates
at 50GHz DWDM wavelengths according to ITU-T G.694.1 and it provides monitoring of
operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
Protocols • 8G FC
• STM-64/OC-192
• 10 GbE WAN PHY
• 10G IB
• 10 GbE LAN PHY
• 10G FC
• OTU2
• 10G IB
• OTU2V
• OTU1e
• OTU2e
• OTU2f
Dispersion load range with 1 dB -500 ps/nm ... -300 ps/nm and
OSNR penalty +300 ps/nm ...+500 ps/nm
Dispersion load range with 2 dB -700 ps/nm ... -500 ps/nm and
OSNR penalty +500 ps/nm ... +700 ps/nm
SFP+/11GU/CxxxxL/SM/LC
The SFP+/11GU/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for up to 11
Gbit/s data rates and bidirectional communication over single-mode fiber. It is operating
at CWDM wavelengths according to ITU-T G.694.2 and it provides monitoring of
operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP+
types approved by ADVA Optical Networking only.
SFP+/11GU/CxxxxV/SM/LC
The SFP+/11GU/CxxxxV/SM/LC is an MSA-compliant pluggable transceiver for up to 11
Gbit/s data rates and bidirectional communication over single-mode fiber. It is operating
at CWDM wavelengths according to ITU-T G.694.2 and it provides monitoring of
operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP+ interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP+
types approved by ADVA Optical Networking only.
Receiver wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm according
to ITU-T G.694.2
SFP+/11GU/1310S/SM/LC
The SFP+/11GU/1310S/SM/LC is an MSA-compliant pluggable transceiver supporting
up to 11 Gbit/s data rates and bidirectional communication over single-mode fiber. It is
operating at a wavelength of 1310 nm and it provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
1
Requires hardware revision 3.01 or higher
2
Requires hardware revision 2.01 or higher
SFP+/10G/1310S/SM/LC
The SFP+/10G/1310S/SM/LC is an MSA-compliant pluggable transceiver supporting up
to 10 Gbit/s data rates and bidirectional communication over single-mode fiber. It is
operating at a wavelength of 1310 nm and it provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in ADVA
Optical Networking’s devices with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types approved by
ADVA Optical Networking only.
SFP+/11GU/850I/MM/LC
The SFP+/11GU/850I/MM/LC is an MSA-compliant pluggable transceiver supporting up
to 11 Gbit/s data rates and bidirectional communication over multimode fiber. It is
operating at a wavelength of 850 nm and it provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
SFP+/10G/850I/MM/LC
The SFP+/10G/850I/MM/LC is an MSA-compliant pluggable transceiver supporting up to
10 Gbit/s data rates and bidirectional communication over multimode fiber. It is operating
at a wavelength of 850 nm and it provides monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in ADVA Optical
Networking’s devices with SFP+ interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP+ types approved by
ADVA Optical Networking only.
1
HW Rev. 2.01 and newer only, which is supported as of Release 11.2.2.
XFP/8G/#xxxxxL/SM/LC#Dxx
The XFP/8G/#xxxxxL/SM/LC#Dxx is an MSA-compliant pluggable transceiver for 4.25
Gbit/s and 8.5 Gbit/s data rates and bidirectional communication over single-mode fiber.
It is operating at DWDM wavelengths according to ITU-T G.694.1 and provides
monitoring of operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with XFP
types approved by ADVA Optical Networking only.
Protocols • 4G FC
• 8G FC
XFP/8G/CxxxxL/SM/LC
The XFP/8G/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for 4.25 Gbit/s
and 8.5 Gbit/s data rates and bidirectional communication over single-mode fiber. It is
operating at CWDM wavelengths according to ITU-T G.694.2 and it provides monitoring
of operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with XFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with XFP
types approved by ADVA Optical Networking only.
Protocols 4G FC, 8G FC
XFP/8G/1310S/SM/LC
The XFP/8G/1310S/SM/LC is an MSA-compliant pluggable transceiver for data rates of
4.25 Gbit/s and 8.5 Gbit/s and bidirectional communication over single-mode fiber. It is
operating at a wavelength of 1310 nm and it provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with XFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
Protocols • 4G FC
• 8G FC
XFP/8G/850I/MM/LC
The XFP/8G/850I/MM/LC is an MSA-compliant pluggable transceiver for data rates of
4.25 Gbit/s and 8.5 Gbit/s and bidirectional communication over multimode fiber. It is
operating at a wavelength of 850 nm and it provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in FSP
3000R7 modules with XFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
Protocols • 4G FC
• 8G FC
SFP+/8GU/1310S/SM/LC
The SFP+/8GU/1310S/SM/LC is an MSA-compliant pluggable transceiver for data rates
up to 8.5 Gbit/s and bidirectional communication over single-mode fiber. It is operating at
a wavelength of 1310 nm and it provides monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP+ interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP+ types approved by ADVA Optical
Networking only.
Transmitter output power range -8.5 dBm ... 0.5 dBm at 8.5 Gbit/s
-8.5 dBm ... -3 dBm at 2.25 Gbit/s and 4.25 Gbit/s
SFP+/8GU/850I/MM/LC
The SFP+/8GU/850I/MM/LC is an MSA-compliant pluggable transceiver for data rates up
to 8.5 Gbit/s and bidirectional communication over multimode fiber. It is operating at a
wavelength of 850 nm and it provides monitoring of operating parameters such as optical
input power, temperature or laser bias. It is intended for use in FSP 3000R7 modules with
SFP+ interface cages. Proper functionality and valid certification of transponder modules
can be guaranteed with SFP+ types approved by ADVA Optical Networking only.
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx
The SFP/4GU/Dxxxx.xxV/SM/LC#Dxx is an MSA-compliant pluggable transceiver for
up to 4.25 Gbit/s data rates and bidirectional communication over single-mode fiber. It is
operating at DWDM wavelengths according to ITU-T G.694.1. It provides monitoring of
operating parameters such as optical input power, temperature or laser bias. It is intended
for use in FSP 3000R7 modules with SFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
Weight 20 g
• 1291 nm
• 1311 nm
• 1331 nm
• 1351 nm
• 1371 nm
• 1431 nm
• 1451 nm according to ITU-T G.694.2
SFP/4GU/CxxxxV/SM/LC (1471 nm to 1611
nm, HW Rev. 3.01)
The SFP/4GU/CxxxxV/SM/LC (1471 nm to 1611 nm, HW Rev. 3.01) is an MSA-
compliant pluggable transceiver for up to 4.25 Gbit/s data rates and bidirectional
communication over single-mode fiber. It is operating at a CWDM wavelength range from
1471 nm to 1611 nm according to ITU-T G.694.2. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. It is intended for use in
FSP 3000R7 modules with SFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
Weight 20 g
SFP/4GU/CxxxxL/SM/LC
The SFP/4GU/CxxxxL/SM/LC is an MSA-compliant pluggable transceiver for up to 4.25
Gbit/s data rates and bidirectional communication over single-mode fiber. It is operating
at CWDM wavelengths according to ITU-T G.694.2. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. It is intended for use in
FSP 3000R7 modules with SFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
Receiver dynamic range -16 dBm ... -6 dBm (1271 ... 1451 nm)
-16 dBm ... 0 dBm (1471 ... 1611 nm)
OPR measurement range -16 dBm ... -3 dBm (1271 ... 1451 nm)
-16 dBm ... 3 dBm (1471 ... 1611 nm)
SFP/4GU/1310S/SM/LC
The SFP/4GU/1310S/SM/LC is an MSA-compliant pluggable 1310 nm transceiver for
bidirectional communication over single-mode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. It is intended for use in
ADVA Optical Networking’s devices with SFP interface cages. Proper functionality and
valid certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
Receiver dynamic range -18 dBm ... -1 dBm (from 1.0625 Gbit/s upto
3.072 Gbit/s)
-15 dBm ... -1 dBm at 4.25 Gbit/s
SFP/4GU/850I/MM/LC
The SFP/4GU/850I/MM/LC is an MSA-compliant pluggable 850 nm transceiver for up to
4.25 Gbit/s data rates and bidirectional communication over multimode fiber. It provides
monitoring of operating parameters such as optical input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
Receiver dynamic range -19 dBm ... 0 dBm (up to 1.0625 Gbit/s),
-17 dBm ... 0 dBm (from 1.0625 Gbit/s to
2.125 Gbit/s),
-14 dBm ... 0 dBm (from 2.4576 Gbit/s to
4.250 Gbit/s
SFP/3GU/BCxxxxL/SM/LC/TIN (1471 nm to
1611 nm)
The SFP/3GU/BCxxxxL/SM/LC/TIN is an MSA-compliant pluggable CWDM transceiver
for up to 3.072 Gbit/s data rates and bidirectional communication over one single-mode
fiber.
This transceiver is transmitting one wavelength and receiving a different wavelength.
Therefore the SFP/3GU/BCxxxxL/SM/LC/TIN is only working as pairs having the same
nominal wavelength. Variants which has to be used in pairs are listed in Table 97, e.g. the
SFP/3GU/BC1465L/SM/LC/TIN is transmitting a signal with a wavelength of 1465 nm at
side A and is capable of receiving a signal with a wavelength of 1475 nm from side B.
Thus, an SFP/3GU/BC1465L/SM/LC/TIN has to be paired with an
SFP/3GU/BC1475L/SM/LC/TIN.
This pluggable transceiver supports an operating temperature within the industrial
temperature range.
The SFP/3GU/BCxxxxL/SM/LC/TIN provides monitoring of operating parameters such
as optical input power, optical output power, temperature, laser bias or supply voltage.
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
SFP/3GU/BCxxxxL/SM/LC/TIN (1271 nm to
1451 nm)
The SFP/3GU/BCxxxxL/SM/LC/TIN (1271 nm to 1451 nm) is an MSA-compliant
pluggable CWDM transceiver for up to 3.072 Gbit/s data rates and bidirectional
communication over one single-mode fiber.
This transceiver is transmitting one wavelength and receiving a different wavelength.
Therefore the SFP/3GU/BCxxxxL/SM/LC/TIN (1271 nm to 1451 nm) is only working as
pairs having the same nominal wavelength. Variants which has to be used in pairs are
listed in Table 99, e.g. the SFP/3GU/BC1265L/SM/LC/TIN is transmitting a signal with a
wavelength of 1265 nm at side A and is capable of receiving a signal with a wavelength of
1275 nm from side B. Thus, an SFP/3GU/BC1265L/SM/LC/TIN has to be paired with an
SFP/3GU/BC1275L/SM/LC/TIN.
This pluggable transceiver supports an operating temperature within the industrial
temperature range.
The SFP/3GU/BCxxxxL/SM/LC/TIN (1271 nm to 1451 nm) provides monitoring of
operating parameters such as optical input power, optical output power, temperature,
laser bias or supply voltage.
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
Protocols • 2 x CPRI
• GbE
• 2G FC
• 4 x CPRI (CPRI line bit rate option 3)
• STM-16/OC-48
• 5 x CPRI (CPRI line bit rate option 4)
• 4 x OBSAI
1at 1350 nm
SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx
The SFP/2G5U/Dxxxx.xxU/SM/LC#Dxx is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at DWDM
wavelengths according to ITU-T G.694.1. It provides monitoring of operating parameters
such as optical input power, temperature or laser bias. It is intended for use in ADVA
Optical Networking’s devices with SFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
Dispersion load range with 1 dB -500 ps/nm ... +100 ps/nm and
OSNR penalty +800 ps/nm ... +1400 ps/nm
Dispersion load range with 2 dB -1100 ps/nm ... -500 ps/nm and
OSNR penalty +1400 ps/nm ... +2000 ps/nm
Dispersion load range with 3 dB -1500 ps/nm ... -1100 ps/nm and
OSNR penalty +2000 ps/nm ... +2400 ps/nm
Receiver wavelength range 1271 nm, 1291 nm, 1311 nm, 1331 nm,
1351 nm, 1371 nm, 1431 nm, 1451 nm
according to ITU-T G.694.2
Receiver wavelength range 1471 nm, 1491 nm, 1511 nm, 1531 nm,
1551 nm, 1571 nm, 1591 nm, 1611 nm
according to ITU-T G.694.2
SFP/2G5U/1310L/SM/LC
The SFP/2G5U/1310L/SM/LC is an MSA-compliant pluggable 1310 nm transceiver for
bidirectional communication over single-mode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. It is intended for use in
ADVA Optical Networking’s devices with SFP interface cages. Proper functionality and
valid certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
SFP/HS/1310S/SM/LC
The SFP/HS/1310S/SM/LC is an MSA-compliant pluggable 1310 nm transceiver for
bidirectional communication over single-mode or multimode fiber. It provides monitoring
of operating parameters such as optical input power, temperature or laser bias.
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
SFP/2G1/850I/MM/LC
The SFP/2G1/850I/MM/LC is an MSA-compliant pluggable 850 nm transceiver for
bidirectional communication over multimode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias.
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
SFP-RXTX/MADI/1310I/MM/LC
The SFP-RXTX/MADI/1310I/MM/LC is an MSA-compliant optical SFP transceiver for
bidirectional communication over multimode fiber.
The SFP-RXTX/MADI/1310I/MM/LC provides monitoring of operating parameters such
as optical input power, temperature or laser bias. It is intended for use in ADVA Optical
Networking’s devices with SFP interface cages. Proper functionality and valid
certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
SFP/GBE/1310S/SM/LC/TIN
The SFP/GBE/1310S/SM/LC/TIN is an MSA-compliant pluggable 1310 nm transceiver
for bidirectional communication over single-mode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. This pluggable
transceiver supports an operating temperature within the industrial temperature range
(see Table 109).
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
1
125 Mbit/s not useable in FSP 3000R7.
SFP/GBE/1310L/SM/LC/TIN
The SFP/GBE/1310L/SM/LC/TIN is an MSA-compliant pluggable 1310 nm transceiver
for bidirectional communication over single-mode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. This pluggable
transceiver supports an operating temperature within the industrial temperature range
(see Table 110).
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
1
125 Mbit/s not useable in FSP 3000R7.
SFP/GBE/1550V/SM/LC/TIN
The SFP/GBE/1550V/SM/LC/TIN is an MSA-compliant pluggable 1550 nm transceiver
for bidirectional communication over single-mode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. This pluggable
transceiver supports an operating temperature within the industrial temperature range
(see Table 111).
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
1
125 Mbit/s not useable in FSP 3000R7.
SFP/GBE/850I/MM/LC/TIN
The SFP/GBE/850I/MM/LC/TIN is an MSA-compliant pluggable 850 nm transceiver for
bidirectional communication over multimode fiber. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. This pluggable
transceiver supports an operating temperature within the industrial temperature range
(see Table 112).
It is intended for use in ADVA Optical Networking’s devices with SFP interface cages.
Proper functionality and valid certification of transponder modules can be guaranteed with
SFP types approved by ADVA Optical Networking only.
1
125 Mbit/s not useable in FSP 3000R7.
SFP/GBE/Electrical/RJ45
The SFP/GBE/Electrical/RJ45 is a pluggable transceiver that provides an electrical Gbit
Ethernet port. It is intended for use in FSP 3000R7 modules with SFP interface cages on
client ports. Proper functionality and valid certification of transponder modules can be
guaranteed with SFP types approved by ADVA Optical Networking only.
This pluggable transceiver does not support error propagation code (EPC) as error
forwarding mode on FSP 3000R7.
Protocols 10/100/1000BASE-T1
1
10/100BASE-T not useable in FSP 3000R7
SFP/GBE/B1310L/SM/LC
The SFP/GBE/B1310L/SM/LC is an MSA-compliant pluggable 1310 nm transceiver for
bidirectional communication over one single-mode fiber. It is used in pair with a
complementary bidirectional SFP which has a different wavelength, e.g. the
SFP/GBE/B1490L/SM/LC.
The SFP/GBE/B1310L/SM/LC provides monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.
SFP/GBE/B1490L/SM/LC
The SFP/GBE/B1490L/SM/LC is an MSA-compliant pluggable 1490 nm transceiver for
bidirectional communication over one single-mode fiber. It is used in pair with a
complementary bidirectional SFP which has a different wavelength, e.g. the
SFP/GBE/B1310L/SM/LC.
The SFP/GBE/B1490L/SM/LC provides monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.
SFP/GBE/B1310S/SM/LC
The SFP/GBE/B1310S/SM/LC is an MSA-compliant pluggable 1310 nm transceiver for
bidirectional communication over one single-mode fiber. It is used in pair with a
complementary bidirectional SFP which has a different wavelength, e.g. the
SFP/GBE/B1490S/SM/LC.
The SFP/GBE/B1310S/SM/LC provides monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.
SFP/GBE/B1490S/SM/LC
The SFP/GBE/B1490S/SM/LC is an MSA-compliant pluggable 1490 nm transceiver for
bidirectional communication over one single-mode fiber. It is used in pair with a
complementary bidirectional SFP which has a different wavelength, e.g. the
SFP/GBE/B1310S/SM/LC.
The SFP/GBE/B1490S/SM/LC provides monitoring of operating parameters such as
optical input power, temperature or laser bias. It is intended for use in FSP 3000R7
modules with SFP interface cages. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.
SFP/FE/C1490U/SM/LC
The SFP/FE/C1490U/SM/LC is an MSA-compliant pluggable transceiver for bidirectional
communication over single-mode fiber. It is operating at 1490 nm. It provides monitoring
of operating parameters such as optical input power, temperature or laser bias. It is
intended for use in ADVA Optical Networking’s devices with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
Receiver dynamic range -42 dBm ... -9 dBm (BER < 10-7)
SFP/FE/C1510U/SM/LC
The SFP/FE/C1510U/SM/LC is an MSA-compliant pluggable transceiver for bidirectional
communication over single-mode fiber. It is operating at 1510 nm. It provides monitoring
of operating parameters such as optical input power, temperature or laser bias. It is
intended for use in ADVA Optical Networking’s devices with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
Receiver dynamic range -42 dBm ... -9 dBm (BER < 10-7)
SFP/FE/D1528.77E/SM/LC
The SFP/FE/D1528.77E/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at 1528.77 nm. It
provides monitoring of operating parameters such as optical input power, temperature or
laser bias. It is intended for use in FSP 3000R7 OSCM-PN modules. The
SFP/FE/D1528.77E/SM/LC does not support the intrusion detection functionality of the
OSCM-PN.
Receiver dynamic range -42 dBm ... -10 dBm (BER < 10-7)
SFP/FE/Dxxxxx.xxV/SM/LC
The SFP/FE/Dxxxxx.xxV/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is available as SFP/FE/D1531.12
V/SM/LC and SFP/FE/D1531.90V/SM/LC. It provides monitoring of operating
parameters such as optical input power, temperature or laser bias. It is intended for use in
FSP 3000R7 OSCM-PN modules.
Receiver dynamic range -32 dBm ... -15 dBm (BER < 10-7) at 12 dB OSNR
SFP/FE/C1490V/SM/LC
The SFP/FE/C1490V/SM/LC is an MSA-compliant pluggable transceiver for bidirectional
communication over single-mode fiber. It is operating at 1490 nm. It provides monitoring
of operating parameters such as optical input power, temperature or laser bias. It is
intended for use in FSP 3000R7 modules with SFP interface cages. Proper functionality
and valid certification of transponder modules can be guaranteed with SFP types
approved by ADVA Optical Networking only.
Receiver dynamic range -30 dBm ... 0 dBm (BER < 10-7)
SFP/FE/C1510V/SM/LC
The SFP/FE/C1510V/SM/LC is an MSA-compliant pluggable transceiver for bidirectional
communication over single-mode fiber. It is operating at 1510 nm. It provides monitoring
of operating parameters such as optical input power, temperature or laser bias. It is
intended for use in FSP 3000R7 modules with SFP interface cages. Proper functionality
and valid certification of transponder modules can be guaranteed with SFP types
approved by ADVA Optical Networking only.
Receiver dynamic range -30 dBm ... 0 dBm (BER < 10-7)
SFP/3GSDI/#xxxxxV/SM/LC
The SFP/3GSDI/#xxxxxV/SM/LC is an MSA-compliant pluggable transceiver for
bidirectional communication over single-mode fiber. It is operating at DWDM
wavelengths according to ITU-T G.694.1. The SFP/3GSDI/#xxxxxV/SM/LC supports
data rates for the transmission of SD-SDI, HD-SDI and 3G-SDI video signals on the
network ports.
This pluggable transceiver provides monitoring of operating parameters such as optical
input power, temperature or laser bias.
It is intended for use in FSP 3000R7 modules with SFP interface cages. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
Receiver dynamic range -30 ... -9 dBm at 270 Mbit/s and 360 Mbit/s
(OSNR >30 dB) -29 ... -9 dBm at 1.485 Gbit/s
-28 ... -9 dBm at 2.97 Gbit/s
Receiver dynamic range -28 ... -9 dBm at 270 Mbit/s and 360 Mbit/s
(OSNR >20 dB) -27 ... -9 dBm at 1.485 Gbit/s
SFP-2TX/3GSDI/1310S/SM/LC
The SFP-2TX/3GSDI/1310S/SM/LC is an optical SFP dual transmitter module for
unidirectional communication over two single-mode fibers. It is specifically designed to
transmit two SDI signals up to 2.97Gbit/s at a wavelength of 1310 nm. The dual optical
transmitter automatically converts electrical serial signals to optical serial digital signals.
The SFP-2TX/3GSDI/1310S/SM/LC supports MADI and DVB-ASI video signals as well
as SD-SDI, HD-SDI, and 3G-SDI. This module provides monitoring of operating
parameters such as output optical power, temperature, or laser bias.
It is intended for use only in FSP 3000R7 modules designed to support these special
plugs. Proper functionality and valid certification of transponder modules can only be
guaranteed with SFP types approved by ADVA Optical Networking.
The SFP-2TX/3GSDI/1310S/SM/LC is MSA compliant for pluggability and format, but
the electrical pinning is not compatible with the MSA standard.
1
Only in combination with the SFP-2RX/3GSDI/1310S/SM/LC.
SFP-2RX/3GSDI/1310S/SM/LC
The SFP-2RX/3GSDI/1310S/SM/LC is an optical SFP dual receiver module for
unidirectional communication over two single-mode fibers. It is specifically designed to
receive two SDI signals up to 2.97Gbit/s at a wavelength of 1310 nm. The dual optical
receiver automatically converts optical serial digital signals to electrical serial digital
signals.
The SFP-2RX/3GSDI/1310S/SM/LC supports MADI and DVB-ASI video signals as well
as SD-SDI, HD-SDI, and 3G-SDI. This module provides monitoring of operating
parameters such as input signal detection, supply voltage, and temperature.
It is intended for use only in FSP 3000R7 modules designed to support these special
plugs. Proper functionality and valid certification of transponder modules can only be
guaranteed with SFP types approved by ADVA Optical Networking.
The SFP-2RX/3GSDI/1310S/SM/LC is MSA compliant for pluggability and format, but
the electrical pinning is not compatible with the MSA standard.
1
Not compliant to MADI (AES10-2003).
2
Only in combination with the SFP-2TX/3GSDI/1310S/SM/LC.
SFP-2TX/3GSDI/ELECTRICAL/HBNC
The SFP-2TX/3GSDI/ELECTRICAL/HBNC is an electrical SFP dual transmitter module
for unidirectional communication over two 75-Ohm coaxial cables. It is specifically
designed to transmit two SDI signals up to 2.97Gbit/s.
The SFP-2TX/3GSDI/ELECTRICAL/HBNC contains a dual electrical transmitter and
provides two electrical high-density BNC (HD-BNC) interfaces. It supports DVB-ASI,
SD-SDI, HD-SDI, and 3G-SDI video signals. MADI signals may be supported as well,
provided that the client equipment uses an interface capable of handling the differing
electrical properties. This module provides monitoring of operating parameters such as
output signal detection, supply voltage, and temperature.
It is intended for use only in FSP 3000R7 modules designed to support these special
plugs. Proper functionality and valid certification of transponder modules can only be
guaranteed with SFP types approved by ADVA Optical Networking.
The SFP-2TX/3GSDI/ELECTRICAL/HBNC is MSA compliant for pluggability and
format, but the electrical pinning is not compatible with the MSA standard.
Data rates 125 Mbit/s,1 143 Mbit/s, 177 Mbit/s, 270 Mbit/s,
360 Mbit/s, 540 Mbit/s,
1.4835 (1.485 / 1.001) Gbit/s,
1.485 Gbit/s, 2.967 (2.97 / 1.001) Gbit/s,
2.970 Gbit/s
1125 Mbit/s may be used for MADI transport. Please be aware that this pluggable
transceiver complies with electrical interface requirements for transport of SDI
services and not those for transport of MADI services.
2Only in combination with the SFP-2RX/3GSDI/ELECTRICAL/HBNC.
SFP-2RX/3GSDI/ELECTRICAL/HBNC
The SFP-2RX/3GSDI/ELECTRICAL/HBNC is an electrical SFP dual receiver module for
unidirectional communication over two 75-Ohm coaxial cables. It is specifically designed
to receive two SDI signals up to 2.97Gbit/s.
The SFP-2RX/3GSDI/ELECTRICAL/HBNC contains a dual electrical receiver and
provides two electrical high-density BNC (HD-BNC) interfaces. It supports DVB-ASI,
SD-SDI, HD-SDI, and 3G-SDI video signals. MADI signals may be supported as well,
provided that the client equipment uses an interface capable of handling the differing
electrical properties. This module provides monitoring of operating parameters such as
input signal detection, supply voltage, and temperature.
It is intended for use only in FSP 3000R7 modules designed to support these special
plugs. Proper functionality and valid certification of transponder modules can only be
guaranteed with SFP types approved by ADVA Optical Networking.
The SFP-2RX/3GSDI/ELECTRICAL/HBNC is MSA compliant for pluggability and
format, but the electrical pinning is not compatible with the MSA standard.
1125 Mbit/s may be used for MADI transport. Please be aware that this pluggable
transceiver complies with electrical interface requirements for transport of SDI
services and not those for transport of MADI services.
2Only in combination with the SFP-2TX/3GSDI/ELECTRICAL/HBNC.
SFP/3GSDI/ELECTRICAL/DIN
The SFP/3GSDI/ELECTRICAL/DIN is an MSA SFF-8074 compliant pluggable
transceiver that provides an electrical DIN1.0/2.3 interface for the support of SD-SDI,
HD-SDI and 3G-SDI video signals. It is intended for use in FSP 3000R7 modules with
SFP interface cages on the client ports. Proper functionality and valid certification of
transponder modules can be guaranteed with SFP types approved by ADVA Optical
Networking only.
Data rates 270 Mbit/s, 360 Mbit/s, 1.485 Gbit/s, 2.97 Gbit/s
SFP/3GSDI/ELECTRICAL/HBNC
The SFP/3GSDI/ELECTRICAL/HBNC is an MSA SFF-8074 compliant pluggable
transceiver that provides an electrical high-density BNC (HD-BNC) interface for the
support of SD-SDI, HD-SDI and 3G-SDI video signals. It is intended for use in FSP
3000R7 modules with SFP interface cages on the client ports. Proper functionality and
valid certification of transponder modules can be guaranteed with SFP types approved by
ADVA Optical Networking only.
Data rates 270 Mbit/s, 360 Mbit/s, 1.485 Gbit/s, 2.97 Gbit/s
1061701841-01 XFP/11G/1310S/SM/LC/TIN
1061701842-01 XFP/11G/1550L/SM/LC/TIN
1061701843-01 XFP/11G/1550V/SM/LC/TIN
1061701845-01 XFP/10G/850I/MM/LC/TIN
1061701891-01 XFP/10G/B1270S/SM/LC/TIN
1061701892-01 XFP/10G/B1330S/SM/LC/TIN
1061701893-01 XFP/10G/B1270L/SM/LC/TIN
1061701894-01 XFP/10G/B1330L/SM/LC/TIN
1061005858-01 SFP/SOAM/GBE/1310S/SM/LC/TIN
1061004048-01 SFP/TSOP155/GBE/1310S/SM/LC/TIN
1061004049-01 SFP/TSOP622/GBE/1310S/SM/LC/TIN
XFP/11G/1310S/SM/LC/TIN
The XFP/11G/1310S/SM/LC/TIN is an MSA-compliant pluggable transceiver for 10
Gbit/s and 11 Gbit/s data rates and bidirectional communication over single-mode fiber. It
is operating at a wavelength of 1310 nm and it provides monitoring of operating
parameters such as optical input power, temperature or laser bias. Functionality and valid
certification of transponder modules can be guaranteed with XFP types approved by
ADVA Optical Networking only.
XFP/11G/1550L/SM/LC/TIN
The XFP/11G/1550L/SM/LC/TIN is an MSA-compliant pluggable transceiver for 10
Gbit/s data rates and bidirectional communication over single-mode fiber. It is operating
at a wavelength of 1550 nm and it provides monitoring of operating parameters such as
optical input power, temperature or laser bias. Functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
XFP/11G/1550V/SM/LC/TIN
The XFP/11G/1550V/SM/LC/TIN is an MSA-compliant pluggable transceiver for 10
Gbit/s data rates and bidirectional communication over single-mode fiber. It is operating
at a wavelength of 1550 nm and it provides monitoring of operating parameters such as
optical input power, temperature or laser bias. Functionality and valid certification of
transponder modules can be guaranteed with XFP types approved by ADVA Optical
Networking only.
XFP/10G/850I/MM/LC/TIN
The XFP/10G/850I/MM/LC/TIN is an MSA-compliant pluggable transceiver for 10 Gbit/s
data rates and bidirectional communication over multimode fiber. It is operating at a
wavelength of 850 nm and it provides monitoring of operating parameters such as optical
input power, temperature or laser bias.
Functionality and valid certification of transponder modules can be guaranteed with XFP
types approved by ADVA Optical Networking only.
XFP/10G/B1270S/SM/LC/TIN
The XFP/10G/B1270S/SM/LC/TIN is an MSA-compliant pluggable transceiver for
bidirectional communication over one single-mode fiber. It is used in pair with a
complementary bidirectional XFP which has a different wavelength, e.g. the
XFP/10G/B1330S/SM/LC/TIN. The XFP/10G/B1270S/SM/LC/TIN provides monitoring
of operating parameters such as optical input power, temperature or laser bias. Proper
functionality and valid certification of transponder modules can be guaranteed with XFP
types approved by ADVA Optical Networking only.
Protocols 10GBASE-LR/LW
XFP/10G/B1330S/SM/LC/TIN
The XFP/10G/B1330S/SM/LC/TIN is an MSA-compliant pluggable transceiver for
bidirectional communication over one single-mode fiber. It is used in pair with a
complementary bidirectional XFP which has a different wavelength, e.g. the
XFP/10G/B1270S/SM/LC/TIN. The XFP/10G/B1330S/SM/LC/TIN provides monitoring
of operating parameters such as optical input power, temperature or laser bias. Proper
functionality and valid certification of transponder modules can be guaranteed with XFP
types approved by ADVA Optical Networking only.
Protocols 10GBASE-LR/LW
XFP/10G/B1270L/SM/LC/TIN
The XFP/10G/B1270L/SM/LC/TIN is an MSA-compliant pluggable transceiver for
bidirectional communication over one single-mode fiber. It is used in pair with a
complementary bidirectional XFP which has a different wavelength, e.g. the
XFP/10G/B1330L/SM/LC/TIN. The XFP/10G/B1270L/SM/LC/TIN provides monitoring of
operating parameters such as optical input power, temperature or laser bias. Proper
functionality and valid certification of transponder modules can be guaranteed with XFP
types approved by ADVA Optical Networking only.
Protocols 10GBASE-LR/LW
XFP/10G/B1330L/SM/LC/TIN
The XFP/10G/B1330L/SM/LC/TIN is an MSA-compliant pluggable transceiver for
bidirectional communication over one single-mode fiber. It is used in pair with a
complementary bidirectional XFP which has a different wavelength, e.g. the
XFP/10G/B1270L/SM/LC/TIN. The XFP/10G/B1330L/SM/LC/TIN provides monitoring of
operating parameters such as optical input power, temperature or laser bias. Proper
functionality and valid certification of transponder modules can be guaranteed with SFP
types approved by ADVA Optical Networking only.
Protocols 10GBASE-LR/LW
SFP/SOAM/GBE/1310S/SM/LC/TIN
The SFP/SOAM/GBE/1310S/SM/LC/TIN is a state-of-the-art 1310 nm, 1000Base-LX,
Gigabit Ethernet small form factor pluggable (SFP) transceiver that enables testing and
troubleshooting processes by supporting port and VLAN loopbacks via proprietary in-
band control mechanism. This enables commissioning, verification and troubleshooting
tests such as RFC-2544 and Y.1564 to be executed on an access circuit without
deploying a stand-alone network interface demarcation device. The
SFP/SOAM/GBE/1310S/SM/LC/TIN module can be controlled from ADVA Optical
Networking equipment, or remote test set. Future software upgrades will allow the SFP to
source test traffic for RFC-2544 and Y.1564 tests, as well as to peer with Y.1731 OAM
infrastructures for in-service monitoring of key performance indicators like network delay,
jitter, and packet loss to guarantee service level agreements (SLAs) are met.
The SFP supports bidirectional communication over singlemode fibers, operating at a
wavelength of 1310 nm. It provides monitoring of operating parameters such as optical
input power, temperature and laser bias. This pluggable transceiver supports an operating
temperature within the industrial temperature range. Proper functionality and valid
certification of transceivers can be guaranteed with SFP types approved by ADVA
Optical Networking only.
SFP/TSOP155/GBE/1310S/SM/LC/TIN
The SFP/TSOP155/GBE/1310S/SM/LC/TIN is a pluggable transceiver providing
SONET/SDH OC-3/STM-1 at the optical fiber interface and Gigabit Ethernet at the 20-pin
electrical interface. The internal protocol processing engine supports Transparent
SONET/SDH over Packet (TSoP), a method for encapsulating SONET/SDH bit-streams
as pseu-do wires over a packet switching network. The SFP supports bidirectional
communication over singlemode fibers, operating at a wavelength of 1310 nm. It provides
monitoring of operating parameters such as optical input power, temperature and laser
bias. This pluggable transceiver supports an operating temperature within the industrial
temperature range. Proper functionality and valid certification of transceivers can be
guaranteed with SFP types approved by ADVA Optical Networking only.
SFP/TSOP622/GBE/1310S/SM/LC/TIN
The SFP/TSOP622/GBE/1310S/SM/LC/TIN is a pluggable transceiver providing
SONET/SDH OC-12/STM-4 at the optical fiber interface and Gigabit Ethernet at the 20-
pin electrical interface. The internal protocol processing engine sup-ports Transparent
SONET/SDH over Packet (TSoP), a method for encapsulating SONET/SDH bit-streams
as pseu-do wires over a packet switching network. The SFP supports bidirectional
communication over singlemode fibers, operating at a wavelength of 1310 nm. It provides
monitoring of operating parameters such as optical input power, temperature and laser
bias. This pluggable transceiver supports an operating temperature within the industrial
temperature range. Proper functionality and valid certification of transceivers can be
guaranteed with SFP types approved by ADVA Optical Networking only.
Table 143: MTBF Hours for FSP 3000R7 Pluggable Transceiver Modules
Chapter 2
• added footnote to SFP+/10G/850I/MM/LC and
SFP+/10G/850I/MM/LC
• moved SFP/GBE/Electrical/RJ45 from Chapter “FSP
3000R7 Pluggable Transceivers” to Chapter “Universal
Pluggable Transceivers”
• revised protocols of SFP/GBE/Electrical/RJ45
Chapter 3
• revised specification of
SFP/4GU/Dxxxx.xxV/SM/LC#Dxx
• revised OSNR penalty specification of
XFP/16GFC/#19xxxL50/SM/LC and
XFP/16GFC/#xxxxxL/SM/LC#Dxx
• revised MTBF value and dispersion load range of
XFP/11G/#19xxxL50/SM/LC
• added SFP+CDR/11GU/#19xxxV/SM/LC
• revised “Min. extinction ratio” of
SFP+/11GU/1310S/SM/LC
• added following pluggables for demo purposes only in
13.1
o SFP-2TX/3GSDI/1310S/SM/LC
o SFP-2RX/3GSDI/1310S/SM/LC
o SFP-2TX/3GSDI/ELECTRICAL/HBNC
o SFP-2RX/3GSDI/ELECTRICAL/HBNC
Chapter 3
• revised MTBF values of SFP+/11GU/DCTV/SM/LC ,
SFP+/16GFC/#19xxxL50/SM/LC and
CFP/112G/SR10/MM/MPO
Chapter 3
• added max. link distance for following pluggable
transceivers:
SFP+CDR/10GU/1550L/SM/LC,
SFP+CDR/11GU/1310S/SM/LC
• revised “Receiver dynamic range” of
SFP/FE/C1490V/SM/LC and SFP/FE/C1510V/SM/LC
• revised specification of CFP/112G/#DCTC/SM/LC
• added CFP/112G/SR10/MM/MPO as released
• revised “MTBF at 25°C ambient temperature” of
XFP/11G/#19xxxL50/SM/LC and
SFP+CDR/11GU/CxxxxS/SM/LC
• revised “Transmitter output power range” of
SFP+/11GU/1310S/SM/LC and
SFP+/10G/1310S/SM/LC
Chapter 3
• added CFP/112G/#DCTC/SM/LC as released
• CFP/4x28G/#DCTL/SM/LC and CFP/4x28G/#19xxx-
#19xxxL/SM/LC: corrected typo of “Receiver dynamic
range” value
• added CFP/4x28G/#19xxx-#19xxxLR,
SFP+/11GU/CxxxxV/SM/LC,
SFP/4GU/CxxxxV/SM/LC (1271 nm to 1451 nm, HW
Rev. 3.01), SFP/3GU/BCxxxxL/SM/LC/TIN and
SFP+CDR/10GU/850I/MM/LC (HW Rev. 2.01)
• added “Max. link distance with SMF-28 fiber (This max.
link distance is calculated with the tolerable dispersion
load. The real link distance may be budget limited.) to
the following transceivers:
o SFP/FE/C1490V/SM/LC
o SFP/FE/C1510V/SM/LC
o SFP+CDR/11GU/CxxxxS/SM/LC
o SFP+CDR/11GU/CxxxxL/SM/LC
o SFP+CDR/10GU/1550L/SM/LC
o SFP+/11GU/CxxxxL/SM/LC
o XFP/8G/CxxxxL/SM/LC
o SFP/4GU/CxxxxV/SM/LC (HW Rev. 2.01)
o SFP/4GU/CxxxxV/SM/LC (HW Rev. 3.01)
o SFP/4GU/CxxxxL/SM/LC
Chapter 3
• revised IEEE standard of following CFPs:
o CFP/112G/LR4/SM/LC
o CFP/112G/SR10/MM/MPO
o CFP/103G/SR10/MM/MPO
• added support of GbE to the
SFP/3GU/BCxxxxL/SM/LC/TIN
• revised “Transmitter output power range” of
SFP+/11GU/CxxxxL/SM/LC
Chapter 4
• revised data rates of following pluggable transceivers:
o XFP/10G/B1270S/SM/LC/TIN
o XFP/10G/B1330S/SM/LC/TIN
o XFP/10G/B1270L/SM/LC/TIN
o XFP/10G/B1330L/SM/LC/TIN
Chapter 3
• changed sales item numbers of the following pluggable
transceivers:
o SFP/GBE/1310S/SM/LC/TIN
o SFP/GBE/1310L/SM/LC/TIN
o SFP/GBE/1550V/SM/LC/TIN
o SFP/GBE/850I/MM/LC/TIN
• revised data rates and protocols of following pluggable
transceivers:
o SFP/4GU/850I/MM/LC
o SFP/4GU/1310S/SM/LC
o SFP/3GU/BCxxxxL/SM/LC/TIN
o SFP+/11GU/CxxxxV/SM/LC
o SFP+/11GU/1310S/SM/LC
o SFP+/11GU/850I/MM/LC
o SFP+/11GU/DCTV/SM/LC
• added CFP/112G/ER4/SM/LC
• removed SFP/2G5U/CxxxxL/SM/LC due to
manufacturer's discontinuation
Chapter 3
• added SFP+CDR/16FC/850I/MM/LC
• added SFP+CDR/16FC/1310S/SM/LC
• added SFP+CDR/11GU/B1270S/SM/LC
• added SFP+CDR/11GU/B1330S/SM/LC
• added SFP+CDR/11GU/B1270L/SM/LC
• added SFP+CDR/11GU/B1330L/SM/LC
• added XFP/11G/B1270L/SM/LC/TIN
• added XFP/11G/B1330L/SM/LC/TIN
• added XFP/11G/B1270S/SM/LC/TIN
• added XFP/11G/B1330S/SM/LC/TIN
• XFP/11G/DCTVX/SM/LC
corrected receiver dynamic range for OSNR 30 dB and
OPR measurement range
• removed XFP/OTN11G/#19xxxV/SM/LC due to
product discontinuation
Chapter 3:
• removed the following pluggable transceivers due to
product discontinuation:
o CFP/112G/LR10R/SM/LC (HW Rev. 1.01)
o XFP/16GFC/#19xxxL50/SM/LC (HW Rev. 1.01)
o XFP/16GFC/#xxxxxL/SM/LC#Dxx (HW Rev.
1.01)
o XFP/11G/DCTLNR/SM/LC (HW Rev. 1.01)
o XFP/11G/Dxxxx.xxV/SM/LC#Dxx (HW Rev.
4.01)
o XFP/10G/850I/MM/LC (HW Rev. 1.01)
o SFP/4GU/CxxxxV/SM/LC (HW Rev. 2.01)
o SFP/CL/1310I/SM/LC (HW Rev. 1.01)
Appendix A:
• removed pluggable transceivers specified under
chapter 2 above from table "MTBF Hours for Universal
Pluggable Transceiver Modules"
• removed the following pluggable transceivers listed
under chapter 3 above from table "MTBF Hours for
FSP3000R7 Pluggable Transceiver Modules"