Professional Documents
Culture Documents
Ron Bliss
Communications Software Product manager
June 27, 2018
OPC UA CONNECTOR
Highest capacity and Provides connectivity to third- Delivers data from Communications service for
performance party OPC UA Servers for FactoryTalk® Linx to third- asset management of
Logix data server FactoryTalk® Software party software via EtherNet/IP process devices
(delivered with FactoryTalk® (delivered with FactoryTalk® OPC DA and UA
Service Platform) Service Platform) (Formerly FactoryTalk® Gateway)
(Formerly RSLinx® Enterprise)
KEPServer Enterprise
CLASSIC
Provides OPC DA access for Enables FactoryTalk® software
third-party software, with to access data from third-party
best support for legacy control equipment
control equipment
Enhanced
Enhanced
OTHER THIRD-PARTY
SOFTWARE
E N A B L I N G T H E C O N N E C T E D E N T E R P R I S E
D A T A S O U R C E S F O R T H E C O N N E C T E D E N T E R P R I S E
Classic
OPC DA OPC UA Connector
High Performance Data Server Client
NEW
HMI TAG SERVER
Third-party Software & Hardware
Control Hardware
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 3
FactoryTalk® Service Platform
• Common • Common address • System-wide • System wide
Software License lookup of access to real- notification of real-
Management for resources that are time data time alarms and
all FactoryTalk shared among • Global events that
products FactoryTalk namespace require action
enabled products browsing services
Alarms and
Activation Directory Live Data
Events
EXTENDED
CLASSIC
New
New
KEPServer Enterprise
Overview
• FactoryTalk® Linx V6.00 added network browsing
component and communications services for
Studio 5000® Logix Designer V31
• Choose which Linx edition for on-line interactions
• Driver configuration integrated in network browser
• Enhanced usability, topology search and auto EDS
Upload
• Large 4,000 byte connection for download operations
Benefits
• Reduces steps and time required to configure
network drivers
• Streamlines network setup and system navigation
• Shorter download time over Wi-Fi and VPN remote
connections gives faster startup and system recovery
E xp a n d i n g t h e r e a c h o f t h e C o n n e c t e d E n t e r p r i s e
TCP /
HTTPS
TSN
OPC Unified Architecture
• OPC UA provides open communications for industrial
automation
• Improved security, capacity, performance and
Read / Write Methods Alarm s Historical Pub/Sub stability over OPC DA / Classic
/ Subscribe
companion specifications
Motion Safety
All Software on External OPC Isolated Linx Isolated Software Distribute and redundant Solution for
a Single PC Client Data Server on Different PCs larger configurations
OPC Client OPC Client OPC Client OPC Client OPC Client OPC Client OPC Client
Software Software Software Software Software Software Software
FactoryTalk ® Services
Basic or Standard
Distributed or Professional
Scalable solution for multiple system configurations
Overview
OPC Client Software • Install FactoryTalk® Linx Gateway on the OPC Client workstation
to utilize FactoryTalk® Linx redundant servers
FactoryTalk® • The FactoryTalk® Linx Gateway will make simultaneous requests
Linx Gateway to both FactoryTalk® Linx servers
Distributed or Professional • Each data server establishes a connection to the controller(s)
• When the acting primary fails, the secondary starts delivering
data
• Option to switch back to primary when available
• Perform PC and operating system updates one server at a time
FactoryTalk® FactoryTalk® while maintaining the other
Linx Linx
• Similar to OPC UA Part 4 – 6.6.2.3 Transparent Redundancy
Benefits
• Deliver data for critical systems that cannot shut down
• Redundancy is transparent to the OPC Client
• Eliminates the data server as a single point of failure
Software Overview
• Two paths configured to a Logix 5000™ controller
• Simultaneous connections via both paths
▼ShortcutName • Communicate via one path a time
├Path1 • Queries controller ~2sec to detect path failure and
└Path2
switches automatically
• Shares single set of optimized tag lists
• Holds last state to minimize HMI blind time
Redundant • @Define tags to monitor and switch paths
Controller
192.168.0.12
192.168.0.10
Paths
Benefits
• Prevents network hardware or cable failure from
impacting system operation
• Increased system availability with minimal impact to
network traffic
• Fast recovery maximizes system output
Not available on PanelView™ Plus
Overview
Software
• FactoryTalk® Linx provides multiple types of shortcuts to
talk with control Devices
Linx • Unsolicited – Logix messages (others planned)
Linx OPC UA Connector • Processor – Rockwell Automation® Controllers
• Symbolic – Power Monitors, Micro800
• EDS Parameter – Many devices (Ex Stratix® …)
• CIP Object / CIP Energy (Ex. PowerFlex®, E300…)
• FactoryTalk® Linx OPC UA Connector can interface
directly with devices using OPC UA
3rd Party
Software
Benefits
• Reduces dependence on Logix to store and forward
Non-RA Control • Increased performance
Hardware
• Permits reading data when no controller is present
Overview
999 999 945 719 059 • FactoryTalk® Linx v5.80 enabled connectivity to CIP
0 0 0 , 0 0 0 , 0 5 6 , 8 2 0. 1 6 0 Energy information directly from select control and power
1 6 7 KWH
1 1 1 1 1ENERGY
1CONSUMED 1 27
9 3ODOMETER
monitor devices for FactoryTalk® software
• Create Faceplates and Dashboards to monitor status
New
and usage
• FactoryTalk® Linx Gateway v6.00 permits access for
third-party software
Classic
▪ Single executable (application or service mode) ▪ Separate service and configuration component
(change without restart)
▪ DTL API (no longer sold)
▪ Classic OPC DA and New OPC UA Interface
▪ DDE / FastDDE (infrequently used)
▪ Logix Unsolicited (adding PLC-2)
▪ Classic OPC DA interface ▪ Highly optimized for Logix, also supports PLC-5,
▪ PLC-2, PLC-5, Logix Unsolicited SLC-500 and Micro800 controllers
▪ Comprehensive legacy and Logix controller ▪ Enhanced system diagnostics and counters
support ▪ CIP Energy and Power monitor data
▪ EtherNet/IP to DH+ Tunneling ▪ Access to OPC DA and UA server data
▪ Remote Pass-through (Gateway) ▪ Scalable from single workstation to distributed
and redundant data servers
▪ Updated annually to keep pace with Logix
releases and new functionality
EtherNet/IP OPC UA
CIP Security Security Benefit
• Data Encryption to maintain integrity of critical information
Third-party
OPC UA Sever • Limits changes to authorized users
Overview
• FactoryTalk® Linx v6.10 CIP Security extensions
NEW
Policy Manager • Local and remote browsing services for the
FactoryTalk® Policy Manager
• Delivers security configuration into secured devices
• Enhanced discovery services to detect secured
devices (CIP TCP ports are disabled when secured)
• Can use CIP Security to established secure /
encrypted connection
• Utilizes ODVA CIP Security standard
EHNANCED
EtherNet/IP
CIP Security Benefit
• Enhances system integrity by securing and encrypting
communications to Logix5000™ controllers
• Enables centralized management of control system
security configuration
https://www.odva.org/Technology-Standards/Common-Industrial-P rotocol-CIP/CIP-Security
* Initially FactoryTalk® Linx and secured controllers must be on the same physical sub-network.
Active Directory
Stores IPSec Policy
Overview
• Internet Protocol Security (IPSec) “secures IP packets
through the use of packet filtering, cryptographic security
services, and the enforcement of trusted
communications”
IPSec workstation 1 IPSec workstation 2
• Performing testing with FactoryTalk® communications
polls for policy polls for policy with Windows IPSec tunneling enabled
updates updates
• Plan to provide a whitepaper describing how to utilize in a
IPSec policy IPSec policy production system
downloaded to downloaded to • Many online resources and videos available
workstation 1 workstation 2
Benefit
IPSec-Protected Communications
Services Workstation 2 • Secure/encrypt distributed FactoryTalk® communications
Workstation 1
• Utilizes Microsoft Windows standard services that most IT
groups are generally familiar with
Overview
• FactoryTalk® Linx v6.10 includes OPC UA Security
• Certificate based security
THIRD-PARTY OPC
UA CLIENT • None, 128basic, 256basic and 256sha256 policies
• Sign only, Sign and Encryption, or both
UA TCP
• Client Application authentication
• Anonymous logon (option for read-only)
• Option to utilize FactoryTalk® Security logon for
external client authentication
• FactoryTalk® Security & Audit control and tack
configuration changes and data writes
CIP
Benefits
NEW • Limits access to authorized OPC UA Clients
• Enhanced data integrity for information exchanged with
OPC UA clients
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 27
FactoryTalk® Linx
PLC-2® Unsolicited Messaging
FTL ≥ v6.10
Third-party OPC UA
Client Software Overview
• FactoryTalk® Linx versions v5.70 added ability to accept
data sent from for Logix by “unsolicited” messages
ViewSE & Linx™ Gateway • Controller logic initiates a “MSG” instruction to send
Info Software
data to an external source
• Individual scalar value or array
• Typically sent from controller to controller
• FactoryTalk® Linx can also function as a recipient
• FactoryTalk® Linx v6.10 adds ability to receive messages
using the PLC-2® format
• Logix 5000™, PLC-5® and SLC™ 500 controllers can all
send PLC-2® formatted messages
Benefit
• Unsolicited messages reduce controller processing and
network traffic by send data only when needed (events)
• Minimize impact of migrating older systems when
migrating from RSLinx® Classic to FactoryTalk® Linx
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 28
FactoryTalk® Linx Dual Service Option
Doubling the Data Server Capacity
FTLGW ≥ v6.10
Overview
• FactoryTalk® Linx v6.10 provides an option to run two
parallel data servers in the same workstation / VM
• Takes advantage of modern multi-core CPUs to
significantly expand capacity
• Configured using a single common user interface
• Remote administration in a distributed system
Benefits
• Add capacity without having to add additional server
hardware
• Reduce the number of operating system licenses
• More efficient use of available resources
NEW
Off-line tag names pulled directly Closely developed, Dual Instance for increased data
from Logix project .ACD file maintained, tested and capacity and performance
supported with Logix
Automatically synchronizes Logix CIP Security encrypted
on-line tag definition changes communications to Logix
Access to CIP Energy and more…
power usage data Polled and Unsolicited Logix data Tag poll groups persisted in Logix
memory between requests
The best data server for the Logix 5000™ family of controllers
PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 32
Connectivity Market Drivers & Priorities
• Industrial Big Data and Internet of Things • Add capacity, performance and capabilities
(IIoT) applications for historical tracking and for demanding application
post-mortem analysis • Expanding device connectivity
• Increased data rates for real-time analytics • Enable access to Logix extended information
• Reduce system setup time and complexity to streamline system development
• Continuous / non-stop operation in high • Unify Rockwell Automation® software with a
availability systems single communications package (migrate
• Connectivity between third-party software remaining RSLinx® Classic features)
and hardware via industry standard methods • Extend redundancy and runtime changes
• OPC UA extensions
• Improved security capabilities
Questions?