General: Applicable To: ALL
General: Applicable To: ALL
Avionics Ventilation
ED
Applicable to: ALL
OLL
TR
C ON
During ground operations and depending on the Outside Air Temperature (OAT), the flight crew must limit the time that the aircraft
UNsystem configuration, as follows:
electric power supply is used, in normal avionics ventilation
OAT ≤ 49 °C No limitation
49 °C < OAT ≤ 55 °C 2h
55 °C < OAT ≤ 60 °C 1h
60 °C < OAT ≤ 64 °C 0.5 h
Cabin Pressure
Applicable to: MSN 0429
Maximum positive differential pressure 9.0 PSI
Maximum negative differential pressure -1.0 PSI
Safety relief valve setting 8.6 PSI
Note: Maximum differential pressure (Δp) and safety valve setting tolerance = ± 7 hPa (0.1 PSI).
Cabin Pressure
Applicable to: ALL except MSN 0429
Maximum positive differential pressure 9.0 PSI
Maximum negative differential pressure -1.0 PSI
Safety relief valve setting 8.6 PSI
ED
OLL
TR
ON ED
N C OLL
U TR
C ON
UN
Note: Maximum differential pressure (Δp) and safety valve setting tolerance = ± 7 hPa (0.1 PSI).