General

Applicable to: ALL


With passengers on board, it is not recommended to exceed 20 min without air conditioning supply. The lack of fresh air supply
will significantly reduce the cabin’s air quality.

APU Bleed Use with HP Air Start Unit


Applicable to: ALL
The flight crew must not use bleed air from the APU BLEED and from the HP Air Start Unit at the same time, to prevent any
adverse effect on the Bleed Air System.

Avionics Ventilation
ED
Applicable to: ALL
OLL
TR
C ON
During ground operations and depending on the Outside Air Temperature (OAT), the flight crew must limit the time that the aircraft
UNsystem configuration, as follows:
electric power supply is used, in normal avionics ventilation

OAT ≤ 49 °C No limitation
49 °C < OAT ≤ 55 °C 2h
55 °C < OAT ≤ 60 °C 1h
60 °C < OAT ≤ 64 °C 0.5 h

Cabin Pressure
Applicable to: MSN 0429
Maximum positive differential pressure 9.0 PSI
Maximum negative differential pressure -1.0 PSI
Safety relief valve setting 8.6 PSI

Note: Maximum differential pressure (Δp) and safety valve setting tolerance = ± 7 hPa (0.1 PSI).
Cabin Pressure
Applicable to: ALL except MSN 0429
Maximum positive differential pressure 9.0 PSI
Maximum negative differential pressure -1.0 PSI
Safety relief valve setting 8.6 PSI